Ulf Dammer
University of Erlangen-Nuremberg
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ulf Dammer.
PLOS ONE | 2013
Matthias Ruebner; Pamela L. Strissel; Arif B. Ekici; Elisabeth Stiegler; Ulf Dammer; Tamme W. Goecke; Florian Faschingbauer; Fabian B. Fahlbusch; Matthias W. Beckmann; Reiner Strick
Terminal differentiation of villous cytotrophoblasts (CT) ends in formation of the multinucleated syncytiotrophoblast representing the fetal-maternal interface. Aberrations during this cell-fusion process are associated with Intrauterine Growth Restriction (IUGR), Preeclampsia (PE) and High Elevated Liver and Low Platelets (HELLP) Syndrome. Syncytin-1, the envelope gene of the human Endogenous Retrovirus ERVW-1, is one of the most important genes involved in cell-fusion and showed decreased gene expression during these pathological pregnancies. The aim of this study was to determine the methylation pattern of the entire promoter of ERVW-1 and to correlate these findings with the expression profile of Syncytin-1 in the placental syndromes. 14 isolated villous cytotrophoblasts from control (n = 3), IUGR (n = 3), PE (n = 3), PE/IUGR (n = 3) and HELLP/IUGR (n = 2) placentae were used to determine the mean methylation level (ML) for the ERVW-1 promoter region. ML rose significantly from 29% in control CTs to 49% in IUGR, 53% in PE, 47% in PE/IUGR and 64% in HELLP/IUGR indicating an epigenetic down-regulation of Syncytin-1 by promoter hypermethylation. DNA demethylation of the trophoblast like cell lines BeWo, JEG-3 and JAR with 5-AZA-2′desoxycytidine (AZA) showed an increased Syncytin-1 expression and fusion ability in all cell lines. Promoter activity of the 5′LTR could be inhibited by hypermethylation 42-fold using a luciferase based reporter-gene assay. Finally overexpression of the methyltransferases DNMT3a and LSH could be responsible for a decreased Syncytin-1 expression by promoter hypermethylation of ERVW-1. Our study linked decreased Syncytin-1 expression to an epigenetic hypermethylation of the entire promoter of ERVW-1. Based on our findings we are predicting a broad aberrant epigenetic DNA-methylation pattern in pathological placentae affecting placentogenesis, but also the development of the fetus and the mother during pregnancy.
Ultrasound in Obstetrics & Gynecology | 2016
Sven Kehl; Anika Schelkle; A. Thomas; Alexander Puhl; Katja Meqdad; Benjamin Tuschy; Sebastian Berlit; Christel Weiss; Christian M. Bayer; Jutta Heimrich; Ulf Dammer; Eva Raabe; M. Winkler; Florian Faschingbauer; Matthias W. Beckmann; Marc Sütterlin
To determine whether the amniotic fluid index (AFI) or the single deepest vertical pocket (SDP) technique for estimating amniotic fluid volume is superior for predicting adverse pregnancy outcome.
BioMed Research International | 2014
Michael Schneider; Anne Engel; Peter A. Fasching; Lothar Häberle; Elisabeth B. Binder; Franziska Voigt; Jennifer Grimm; Florian Faschingbauer; Anna Eichler; Ulf Dammer; Dirk Rebhan; Manuela Amann; Eva Raabe; Tamme W. Goecke; Carina Quast; Matthias W. Beckmann; Johannes Kornhuber; Anna Seifert; Stefanie Burghaus
Purpose. The aim of this study was to investigate whether single nucleotide polymorphisms (SNPs) in genes of the stress hormone signaling pathway, specifically FKBP5, NR3C1, and CRHR1, are associated with depressive symptoms during and after pregnancy. Methods. The Franconian Maternal Health Evaluation Study (FRAMES) recruited healthy pregnant women prospectively for the assessment of maternal and fetal health including the assessment of depressiveness. The German version of the 10-item Edinburgh Postnatal Depression Scale (EPDS) was completed at three time points in this prospective cohort study. Visit 1 was at study entry in the third trimester of the pregnancy, visit 2 was shortly after birth, and visit 3 was 6–8 months after birth. Germline DNA was collected from 361 pregnant women. Nine SNPs in the above mentioned genes were genotyped. After construction of haplotypes for each gene, a multifactorial linear mixed model was performed to analyse the depression values over time. Results. EPDS values were within expected ranges and comparable to previously published studies. Neither did the depression scores differ for comparisons among haplotypes at fixed time points nor did the change over time differ among haplotypes for the examined genes. No haplotype showed significant associations with depressive symptoms severity during pregnancy or the postpartum period. Conclusion. The analysed candidate haplotypes in FKBP5, NR3C1, and CRHR1 did not show an association with depression scores as assessed by EPDS in this cohort of healthy unselected pregnant women.
Ultraschall in Der Medizin | 2014
Ulf Dammer; Eva Raabe; Sven Kehl; Matthias Schmid; Andreas Mayr; R. L. Schild; Matthias W. Beckmann; Florian Faschingbauer
PURPOSE To determine the accuracy of sonographic weight estimation (WE) for small-for-gestational-age (SGA) fetuses, and to further differentiate the evaluation between symmetric and asymmetric SGA fetuses. MATERIALS AND METHODS The accuracy of WE in SGA fetuses (n = 898) was evaluated using 14 sonographic models and was further differentiated between symmetric (n = 750) and asymmetric (n = 148) SGA fetuses. SGA fetuses were considered to be asymmetric with a head circumference to abdominal circumference ratio above the 95th percentile. The accuracy of the different formulas was compared using means of percentage errors (MPE), medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS RESULTS for the subgroup of asymmetric SGA fetuses differed significantly from the subgroup of symmetric SGA fetuses. MPE values were closer to zero with most of the formulas in the asymmetric SGA group. Apart from the Siemer, Shepard, Merz and Warsof equations, all formulas showed an underestimation of fetal weight in asymmetric SGA fetuses. In contrast, in the symmetric SGA group, all of the formulas commonly used for fetuses in a normal weight range showed a systematic overestimation of fetal weight. Overall the best accuracy was achieved by using the Sabbagha equation (MPE 1.7 %; SD 9.0 %; MAPE: 6.0). CONCLUSION An accurate WE in SGA fetuses is feasible using the Sabbagha formula. However, one has to be aware of the significant differences in WE between symmetric and asymmetric SGA fetuses.
European Journal of Cancer Prevention | 2014
Christian M. Bayer; Mayada R. Bani; Michael Schneider; Ulf Dammer; Eva Raabe; Lothar Haeberle; Florian Faschingbauer; Sabine Schneeberger; Stefan P. Renner; Dorothea Fischer; R. Schulz-Wendtland; Peter A. Fasching; Matthias W. Beckmann; Sebastian M. Jud
Pregnancies and breastfeeding are two important protective factors concerning breast cancer risk. Breast volume and breast volume changes might be a breast phenotype that could be monitored during pregnancy and breastfeeding without ionizing radiation or expensive equipment. The aim of the present study was to document changes in breast volume during pregnancy prospectively. In the prospective Clinical Gravidity Association Trial and Evaluation programme, pregnant women were followed up prospectively from gestational week 12 to birth. Three-dimensional breast surface imaging and subsequent volume assessments were performed. Factors influencing breast volume at the end of the pregnancy were assessed using linear regression models. Breast volumes averaged 420 ml at the start of pregnancy and 516 ml at the end of pregnancy. The first, second and third quartiles of the volume increase were 41, 95 and 135 ml, respectively. Breast size increased on average by 96 ml, regardless of the initial breast volume. Breast volume increases during pregnancy, but not all womens’ breasts respond to pregnancy in the same way. Breast volume changes during pregnancy are an interesting phenotype that can be easily assessed in further studies to examine breast cancer risk.
Journal of Obstetrics and Gynaecology Research | 2018
Ulf Dammer; Roswitha Bogner; Christel Weiss; Florian Faschingbauer; Jutta Pretscher; Matthias W. Beckmann; Marc Sütterlin; Sven Kehl
We aimed to determine the influence of body mass index (BMI) on induction of labor.
Journal of Obstetrics and Gynaecology Research | 2016
Sven Kehl; Lena Böhm; Christel Weiss; Jutta Heimrich; Ulf Dammer; Friederike Baier; Marc Sütterlin; Matthias W. Beckmann; Florian Faschingbauer
The best time to commence cervical ripening with a balloon catheter is unknown. The aim of this study was to evaluate whether application of a balloon catheter in the morning or in the evening is better when sequential prostaglandin application is planned.
Journal of Ultrasound in Medicine | 2016
Florian Faschingbauer; Ulf Dammer; Eva Raabe; Sven Kehl; Matthias Schmid; R. L. Schild; Matthias W. Beckmann; Andreas Mayr
The purpose of this study was to develop a new specific weight estimation formula for small‐for‐gestational‐age (SGA) fetuses that differentiated between symmetric and asymmetric growth patterns.
European Journal of Obstetrics & Gynecology and Reproductive Biology | 2016
Sven Kehl; Christel Weiss; Ulf Dammer; Jutta Heimrich; Matthias W. Beckmann; Florian Faschingbauer; Marc Sütterlin
OBJECTIVE To evaluate the efficacy of induction of labour using a double-balloon catheter and, if necessary, sequential oral misoprostol without delay after removal of the catheter, in comparison with oral misoprostol alone. STUDY DESIGN This retrospective cohort study included women undergoing induction of labour with oral misoprostol or double-balloon catheter with sequential oral misoprostol in singleton pregnancies at term. The catheter was placed in the evening and removed when there was no onset of labour within 12h. Then oral misoprostol was started within 3h. Primary outcome measure was the caesarean section rate. RESULTS There were 13,082 deliveries during the study period with 3466 labour inductions out of which 1032 were eligible and analysed. The caesarean section rate was significantly lower in the double-balloon catheter group (26.1% vs. 17.3, p=0.021). Furthermore, in the combination group, the induction-to-delivery interval was shorter (median values 1144 vs. 1365min, p=0.001) and there were more deliveries within 24h (51.9 vs. 64.7%, p=0.003) and 48h (87.4 vs. 95.8%, p=0.002). When stratifying for parity, there were less caesarean sections in the combination group (37.2% vs. 24.2%, p=0.015) in nulliparous women, too. In both, nulliparous and parous women, the induction-to-delivery interval was shorter (1742 vs. 1400min, 0.005; 1020 vs. 912min, p=0.018). Especially in parous women, the rates of delivery within 24h (62.6% vs. 79.0%, p=0.007) and 48h (88.6% vs. 99.0%, p=0.007) were higher in the combination group. CONCLUSION Double-balloon catheter and sequential oral misoprostol without long delay in absent onset of labour after removal of the catheter resulted in less caesarean section and shorter induction-to-delivery interval in comparison with oral misoprostol alone.
Ultraschall in Der Medizin | 2012
Florian Faschingbauer; A. Geipel; U. Gembruch; Franziska Voigt; Ulf Dammer; Matthias W. Beckmann; R. L. Schild; Sven Kehl; Matthias Schmid; Andreas Mayr; J. Siemer
PURPOSE To determine the accuracy of sonographic weight estimation (WE) for fetuses with congenital diaphragmatic hernia (CDH), and to assess whether certain sonographic models perform better than others in cases of CDH. MATERIAL AND METHODS In a retrospective, multicenter cohort study, the accuracy of WE in fetuses with CDH (n = 172) was evaluated using eight sonographic models and was compared with a control group of fetuses without malformations (n = 172). Each fetus underwent ultrasound examination with complete biometric parameters within 7 days of delivery. The accuracy of the different formulas was compared using means of percentage errors (MPE), medians of absolute percentage errors (MAPE), and proportions of estimates within 10 % of actual birth weight. RESULTS Fetuses with CDH had a significantly lower abdominal circumference (AC) in comparison with the control group (293.6 vs. 312.0 mm, p < 0.001). All of the formulas tested in fetuses with CDH, except for the Siemer equation (the only model that does not incorporate any abdominal measurements), showed significantly lower (more negative) MPEs, larger MAPEs, and smaller proportions of estimates within 10 % of actual birth weight in comparison with the control group. CONCLUSION The accuracy of sonographic WE in fetuses with CDH is significantly poorer than in fetuses without malformations, principally because of a larger systematic error due to artificially small AC measurements. The development of new, specific models derived from fetuses with CDH could improve the accuracy of WE for infants with this condition.