Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ute von Jan is active.

Publication


Featured researches published by Ute von Jan.


Journal of Medical Internet Research | 2014

Google Glass for documentation of medical findings: evaluation in forensic medicine.

Urs-Vito Albrecht; Ute von Jan; Joachim F. Kuebler; Christoph Zoeller; Martin Lacher; Oliver J. Muensterer; Max Ettinger; Michael Klintschar; Lars Hagemeier

Background Google Glass is a promising premarket device that includes an optical head-mounted display. Several proof of concept reports exist, but there is little scientific evidence regarding its use in a medical setting. Objective The objective of this study was to empirically determine the feasibility of deploying Glass in a forensics setting. Methods Glass was used in combination with a self-developed app that allowed for hands-free operation during autopsy and postmortem examinations of 4 decedents performed by 2 physicians. A digital single-lens reflex (DSLR) camera was used for image comparison. In addition, 6 forensic examiners (3 male, 3 female; age range 23-48 years, age mean 32.8 years, SD 9.6; mean work experience 6.2 years, SD 8.5) were asked to evaluate 159 images for image quality on a 5-point Likert scale, specifically color discrimination, brightness, sharpness, and their satisfaction with the acquired region of interest. Statistical evaluations were performed to determine how Glass compares with conventionally acquired digital images. Results All images received good (median 4) and very good ratings (median 5) for all 4 categories. Autopsy images taken by Glass (n=32) received significantly lower ratings than those acquired by DSLR camera (n=17) (region of interest: z=–5.154, P<.001; sharpness: z=–7.898, P<.001; color: z=–4.407, P<.001, brightness: z=–3.187, P=.001). For 110 images of postmortem examinations (Glass: n=54, DSLR camera: n=56), ratings for region of interest (z=–8.390, P<.001) and brightness (z=–540, P=.007) were significantly lower. For interrater reliability, intraclass correlation (ICC) values were good for autopsy (ICC=.723, 95% CI .667-.771, P<.001) and postmortem examination (ICC=.758, 95% CI .727-.787, P<.001). Postmortem examinations performed using Glass took 42.6 seconds longer than those done with the DSLR camera (z=–2.100, P=.04 using Wilcoxon signed rank test). The battery charge of Glass quickly decreased; an average 5.5% (SD 1.85) of its battery capacity was spent per postmortem examination (0.81% per minute or 0.79% per picture). Conclusions Glass was efficient for acquiring images for documentation in forensic medicine, but the image quality was inferior compared to a DSLR camera. Images taken with Glass received significantly lower ratings for all 4 categories in an autopsy setting and for region of interest and brightness in postmortem examination. The effort necessary for achieving the objectives was higher when using the device compared to the DSLR camera thus extending the postmortem examination duration. Its relative high power consumption and low battery capacity is also a disadvantage. At the current stage of development, Glass may be an adequate tool for education. For deployment in clinical care, issues such as hygiene, data protection, and privacy need to be addressed and are currently limiting chances for professional use.


Journal of Medical Internet Research | 2013

Effects of Mobile Augmented Reality Learning Compared to Textbook Learning on Medical Students: Randomized Controlled Pilot Study

Urs-Vito Albrecht; Kristian Folta-Schoofs; Marianne Behrends; Ute von Jan

Background By adding new levels of experience, mobile Augmented Reality (mAR) can significantly increase the attractiveness of mobile learning applications in medical education. Objective To compare the impact of the heightened realism of a self-developed mAR blended learning environment (mARble) on learners to textbook material, especially for ethically sensitive subjects such as forensic medicine, while taking into account basic psychological aspects (usability and higher level of emotional involvement) as well as learning outcomes (increased learning efficiency). Methods A prestudy was conducted based on a convenience sample of 10 third-year medical students. The initial emotional status was captured using the “Profile of Mood States” questionnaire (POMS, German variation); previous knowledge about forensic medicine was determined using a 10-item single-choice (SC) test. During the 30-minute learning period, the students were randomized into two groups: the first group consisted of pairs of students, each equipped with one iPhone with a preinstalled copy of mARble, while the second group was provided with textbook material. Subsequently, both groups were asked to once again complete the POMS questionnaire and SC test to measure changes in emotional state and knowledge gain. Usability as well as pragmatic and hedonic qualities of the learning material was captured using AttrakDiff2 questionnaires. Data evaluation was conducted anonymously. Descriptive statistics for the score in total and the subgroups were calculated before and after the intervention. The scores of both groups were tested against each other using paired and unpaired signed-rank tests. An item analysis was performed for the SC test to objectify difficulty and selectivity. Results Statistically significant, the mARble group (6/10) showed greater knowledge gain than the control group (4/10) (Wilcoxon z=2.232, P=.03). The item analysis of the SC test showed a difficulty of P=0.768 (s=0.09) and a selectivity of RPB=0.2. For mARble, fatigue (z=2.214, P=.03) and numbness (z=2.07, P=.04) decreased with statistical significance when comparing pre- and post-tests. Vigor rose slightly, while irritability did not increase significantly. Changes in the control group were insignificant. Regarding hedonic quality (identification, stimulation, attractiveness), there were significant differences between mARble (mean 1.179, CI −0.440 to 0.440) and the book chapter (mean −0.982, CI −0.959 to 0.959); the pragmatic quality mean only differed slightly. Conclusions The mARble group performed considerably better regarding learning efficiency; there are hints for activating components of the mAR concept that may serve to fascinate the participants and possibly boost interest in the topic for the remainder of the class. While the small sample size reduces our study’s conclusiveness, its design seems appropriate for determining the effects of interactive eLearning material with respect to emotions, learning efficiency, and hedonic and pragmatic qualities using a larger group. Trial Registration German Clinical Trial Register (DRKS), DRKS-ID: DRKS00004685; https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00004685.


Jmir mhealth and uhealth | 2014

Mobile Technologies: Expectancy, Usage, and Acceptance of Clinical Staff and Patients at a University Medical Center

Kristin Illiger; Markus Hupka; Ute von Jan; Daniel Wichelhaus; Urs-Vito Albrecht

Background Despite their increasing popularity, little is known about how users perceive mobile devices such as smartphones and tablet PCs in medical contexts. Available studies are often restricted to evaluating the success of specific interventions and do not adequately cover the users’ basic attitudes, for example, their expectations or concerns toward using mobile devices in medical settings. Objective The objective of the study was to obtain a comprehensive picture, both from the perspective of the patients, as well as the doctors, regarding the use and acceptance of mobile devices within medical contexts in general well as the perceived challenges when introducing the technology. Methods Doctors working at Hannover Medical School (206/1151, response 17.90%), as well as patients being admitted to this facility (213/279, utilization 76.3%) were surveyed about their acceptance and use of mobile devices in medical settings. Regarding demographics, both samples were representative of the respective study population. GNU R (version 3.1.1) was used for statistical testing. Fisher’s exact test, two-sided, alpha=.05 with Monte Carlo approximation, 2000 replicates, was applied to determine dependencies between two variables. Results The majority of participants already own mobile devices (doctors, 168/206, 81.6%; patients, 110/213, 51.6%). For doctors, use in a professional context does not depend on age (P=.66), professional experience (P=.80), or function (P=.34); gender was a factor (P=.009), and use was more common among male (61/135, 45.2%) than female doctors (17/67, 25%). A correlation between use of mobile devices and age (P=.001) as well as education (P=.002) was seen for patients. Minor differences regarding how mobile devices are perceived in sensitive medical contexts mostly relate to data security, patients are more critical of the devices being used for storing and processing patient data; every fifth patient opposed this, but nevertheless, 4.8% of doctors (10/206) use their devices for this purpose. Both groups voiced only minor concerns about the credibility of the provided content or the technical reliability of the devices. While 8.3% of the doctors (17/206) avoided use during patient contact because they thought patients might be unfamiliar with the devices, (25/213) 11.7% of patients expressed concerns about the technology being too complicated to be used in a health context. Conclusions Differences in how patients and doctors perceive the use of mobile devices can be attributed to age and level of education; these factors are often mentioned as contributors of the problems with (mobile) technologies. To fully realize the potential of mobile technologies in a health care context, the needs of both the elderly as well as those who are educationally disadvantaged need to be carefully addressed in all strategies relating to mobile technology in a health context.


Journal of Medical Internet Research | 2013

Standardized, App-Based Disinfection of iPads in a Clinical and Nonclinical Setting: Comparative Analysis

Urs-Vito Albrecht; Ute von Jan; Ludwig Sedlacek; Stephanie Groos; Sebastian Suerbaum; Ralf-Peter Vonberg

Background With the use of highly mobile tools like tablet PCs in clinical settings, an effective disinfection method is a necessity. Since manufacturers do not allow cleaning methods that make use of anything but a dry fleece, other approaches have to be established to ensure patient safety and to minimize risks posed by microbiological contamination. Objective The ability of isopropanol wipes to decontaminate iPads was evaluated prospectively in a observer blinded, comparative analysis of devices used in a clinical and a nonclinical setting. Methods 10 new iPads were randomly deployed to members of the nursing staff of 10 clinical wards, to be used in a clinical setting over a period of 4 weeks. A pre-installed interactive disinfection application (deBac-app, PLRI MedAppLab, Germany) was used on a daily basis. Thereafter, the number and species of remaining microorganisms on the surface of the devices (13 locations; front and back) was evaluated using contact agar plates. Following this, the 10 iPads were disinfected and randomly deployed to medical informatics professionals who also used the devices for 4 weeks but were forbidden to use disinfecting agents. The quality of a single, standardized disinfection process was then determined by a final surface disinfection process of all devices in the infection control laboratory. No personal data were logged with the devices. The evaluation was performed observer blinded with respect to the clinical setting they were deployed in and personnel that used the devices. Results We discovered a 2.7-fold (Mann-Whitney U test, z=-3.402, P=.000670) lower bacterial load on the devices used in the clinical environment that underwent a standardized daily disinfection routine with isopropanol wipes following the instructions provided by “deBac-app”. Under controlled conditions, an average reduction of the mainly Gram-positive normal skin microbiological load of 99.4% (Mann-Whitney U test, z=-3.1798, P=.001474) for the nonclinical group and 98.1% (Mann-Whitney U test, z=3.1808, P=.001469) for the clinical group was achieved using one complete disinfecting cycle. Conclusions Normal use of tablet PCs leads to a remarkable amount of microbial surface contamination. Standardized surface disinfection with isopropanol wipes as guided by the application significantly reduces this microbial load. When performed regularly, the disinfection process helps with maintaining a low germ count during use. This should reduce the risk of subsequent nosocomial pathogen transmission. Unfortunately, applying a disinfection procedure such as the one we propose may lead to losing the manufacturer’s warranty for the devices; this remains an unsolved issue.


mHealth | 2017

Safe, sound and desirable: development of mHealth apps under the stress of rapid life cycles

Urs-Vito Albrecht; Ute von Jan

Smartphones, tablet PCs and other seemingly “smart” devices are ubiquitous and they are on their way to becoming an integral part of everyday life. Mobile technology seems to fulfill Marc Weiser’s statement from 1991, which was almost prophetic considering today’s use of these devices, where he declared that “The most profound technologies are those that disappear. They weave themselves into the fabric of everyday life until they are indistinguishable from it” (1).


Biomedizinische Technik | 2013

Mobile Smarttracking - Finding Objective Parameters for Determining Fitness to Drive.

Urs-Vito Albrecht; Khatereh Khosravianarab; Kristian Folta-Schoofs; Jörg Teske; Jürgen Kanngießer; Ute von Jan

The misuse of alcohol and drugs has a big influence on traffic safety. For assessing whether a driver is impaired by alcohol or drugs, police conduct roadside tests, e.g. by breathalyzer or similar devices and also use other test batteries such as standardized field sobriety tests (SFT) that evaluate various psychophysical parameters. However, the way these tests are usually conducted often leads to subjective and investigator dependent results. For more objective results that allow to quantify the influence of illicit substances or alcohol using non-invasive test methods, specialized (laboratory) equipment has to be used. In order to allow for a more objective way of testing with devices already available in roadside situations, in our preliminary study, we chose horizontal gaze nystagmus (part of SFT) and implemented it for Android based devices.


Studies in health technology and informatics | 2013

Standard reporting for medical apps.

Urs-Vito Albrecht; Ute von Jan; Oliver Pramann


Studies in health technology and informatics | 2013

Explore and experience: mobile augmented reality for medical training.

Urs-Vito Albrecht; Christoph Noll; Ute von Jan


European Journal of Biomedical Informatics | 2015

Medical Apps -The Road To Trust

Urs-Vito Albrecht; Oliver Pramann; Ute von Jan


Studies in health technology and informatics | 2014

App-synopsis: self-assessment on trust or distrust of health-apps.

Urs-Vito Albrecht; Christoph Noll; Ute von Jan

Collaboration


Dive into the Ute von Jan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge