international power modulator symposium | 1998
van Ejm Bert Heesch; Peter Zacharias; van Svb Sander Paasen; Kj Krzysztof Ptasinski; van der Pct Piet Laan
A new technology area for pulsed corona is hot biogas cleaning, important in view of the growing interest in biomass gasification. Our work concentrates on the development and optimization of pulsed electrical methods for treatment of thermally generated biogas. Corona energized by narrow voltage pulses (100 kV) makes a well ordered and concentrated deposition possible of electrical energy from a circuit into a hot polluted gas. The created plasmas can break down various contaminants. Successful introduction of pulsed corona for industrial processes very much depends on the reliability of high-voltage and pulsed power technology and on the efficiency of energy transfer. In addition, we must achieve adequate electromagnetic compatibility (EMC).
Gaseous dielectrics VI : proceedings of the sixth international symposium on gaseous dielectrics, Knoxville, Tennessee, USA, September 23-27, 1990 | 1991
Jm Jos Wetzer; van Ma Rinus Houten; van der Pct Piet Laan
Voltage transients generated in GIS by the operation of circuit breakers or disconnect switches induce high voltages across interruptions of the enclosure. In this paper we discuss such interruptions and their necessity. We present fast measurements of voltage and current at the GIS/cable-interface of a 150 kV substation, where the enclosure is interrupted to permit current measurement. Circuit breaker operation causes a single voltage transient across the interruption with an amplitude up to 40 kV, a duration of 200–300 ns, and a risetime of about 5 ns. Disconnect switch operation causes multiple transients, each having a smaller amplitude and a longer risetime. The voltage across enclosure interruptions is adequately suppressed, and breakdown is completely eliminated, when the interruption is bridged with resistors. The resistors do not affect the current measurement.
Archive | 1989
van Ejm Bert Heesch; Ajm Guus Pemen; van der Pct Piet Laan
conference; Abstract for the CPS Symposium, Lunteren, Netherlands, 11 March 1997 | 1997
H.W.M. Smulders; van Fm Gompel; van Svb Sander Paasen; van Ejm Bert Heesch; van der Pct Piet Laan
Archive | 1991
van Ejm Bert Heesch; R Caspers; Pfm Gulickx; Gap Gerard Jacobs; Wfj Kersten; van der Pct Piet Laan
European Transactions on Electrical Power | 2007
Ajm Guus Pemen; van der Pct Piet Laan
Archive | 1993
van Ejm Bert Heesch; P.P.M. Blom; van der Pct Piet Laan
10th International Symposium on High Voltage Engineering (ISH 1997), 25-29 August 1997, Montreal, Quebec, Canada | 1997
Ajm Guus Pemen; de W Wout Leeuw; van der Pct Piet Laan
Proceedings of the 7th International Symposium on High Voltage Engineering, 28-30 August 1991, Dresden, Germany | 1991
van Ejm Bert Heesch; van der Pct Piet Laan
European Transactions on Electrical Power | 2007
Al Keet; van der Pct Piet Laan