Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Vanessa Alves Marques is active.

Publication


Featured researches published by Vanessa Alves Marques.


Journal of Clinical Virology | 2013

Simultaneous detection of hepatitis c virus antigen and antibodies in dried blood spots

C.U. Brandão; B.L.C. Marques; Vanessa Alves Marques; Cristiane Alves Villela-Nogueira; M.T. de Paula; Lia Laura Lewis-Ximenez; Elisabeth Lampe; J.A. Sá Ferreira; Livia Melo Villar

BACKGROUND Enzyme immunoassays (EIA) designed to detect hepatitis C virus (HCV) core antigen and anti-HCV antibodies (HCV AgAb) simultaneously can improve the early detection of HCV infection when molecular diagnostic methods are not widely available. OBJECTIVES To evaluate the suitability of dried blood spot (DBS) samples for detecting HCV AgAb using commercial EIAs. STUDY DESIGN Paired serum and DBS samples were assayed using two commercial EIAs for HCV AgAb (Monolisa™ HCV AgAb ULTRA and Murex HCV AgAb). Manufacturers recommendations were followed for sera while sample volume, incubation time and cut-off (CO) determination were evaluated for the DBS samples. The values of sensitivity, specificity, inter-rater agreement, detection limit, assay precision and stability of DBS samples at different conditions (22-26°C, 2-8°C and -20°C) were determined. RESULTS It was necessary to increase the DBS sample volume fourfold compared to the sera samples to approximate the DBS Optical Density (OD) values to the sera OD values. Using ROC curve to recalculate CO values for the DBS samples, sensitivity was 97.5% for both EIAs, while the specificity was 99.71% for Monolisa™ HCV AgAb ULTRA and 95.95% for Murex HCV AgAb. Accurate testing results were obtained with DBS samples for 60 days at all conditions evaluated; storage at -20°C resulted in low OD variation. Both EIAs demonstrated the same limit of detection among DBS samples [estimated viral load of 3.1 International Units per millilitre (IU/mL)] and low OD value variability in repetitivity and reproducibility studies. CONCLUSION DBS samples can be used for the detection of HCV AgAb by EIA as they present comparable performance characteristics and excellent stability among various storage conditions.


Journal of Clinical Virology | 2014

Performance of rapid hepatitis C virus antibody assays among high- and low-risk populations

Leticia de Paula Scalioni; Helena Medina Cruz; Vanessa Salete de Paula; Juliana Custódio Miguel; Vanessa Alves Marques; Cristiane Alves Villela-Nogueira; Flavio Augusto Pádua Milagres; Marcelo Santos Cruz; Francisco I. Bastos; Tarcísio Matos de Andrade; Ana Rita Coimbra Motta-Castro; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

BACKGROUND Rapid tests for the detection of antibodies to hepatitis C virus (anti-HCV) can facilitate access to diagnosis. OBJECTIVES This study aimed to evaluate the performance of rapid tests for anti-HCV detection in the sera, whole blood, and oral fluid samples from individuals with different endemicity profiles and risk behaviors. STUDY DESIGN Three groups donated biological samples that were tested using three anti-HCV rapid tests (WAMA, Bioeasy and OraSure): (I) suspected cases of hepatitis C, (II) individuals who were living in remote areas in Brazil and (III) crack users and beauty professionals. Reproducibility, repeatability and cross-reactivity to other infectious agents (dengue, HIV, malaria, and syphilis) were also evaluated. RESULTS In group I, specificities varied from 93.75% to 100% and sensitivities varied from 76.03% to 93.84% according to the EIA results. When anti-HCV/HCV RNA-reactive sera samples were considered true-positive HCV cases, the sensitivities and specificities varied from 86.3% to 99.09% and 93.75% to 100%, respectively. In group II, the OraSure rapid test presented the best performance. In group III, the Bioeasy assay performed best using saliva and whole blood and the OraSure assay performed best using oral fluid samples. The reproducibility and repeatability of the WAMA and Bioeasy tests were excellent. The level of concordance between the HCV EIAs and the rapid tests using samples that were reactive for other infectious agents varied from 82.35% to 100% for the WAMA assay and 94.11% to 100% for the Bioeasy assay. CONCLUSION All of the rapid tests could be used to identify active HCV infection among individuals with different endemicity profiles and risk behaviors.


Journal of Medical Virology | 2012

Dried blood spot samples: optimization of commercial EIAs for hepatitis C antibody detection and stability under different storage conditions

B.L.C. Marques; C.U. Brandão; Éverton Fagonde da Silva; Vanessa Alves Marques; Cristiane Alves Villela-Nogueira; M.T. de Paula; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

This study was undertaken to optimize and compare the efficiency of two commercial EIAs for anti‐HCV detection (HCV Ab Radim, Pomezzia, Italy and ETI‐AB‐HCVK‐4 DiaSorin, Vercelli, Italy), in dried blood spot (DBS) samples. The long‐term stability of anti‐HCV on DBS samples stored at three environmental conditions was also evaluated at: 2–8°C, 20–25°C, and −20°C. Paired DBS and serum samples were obtained from individuals with or without anti‐HCV. The type of elution buffer, sample and conjugate volume, sample incubation time and cut‐off values were evaluated. For both EIAs, a larger sample volume was used, and the cut‐off value determined by the manufacturer was employed for Radim EIA; however, ROC curve analysis was used for the DiaSorin EIA. The sensitivity and specificity of Radim EIA on DBS were 97.5% and 99.5%, respectively, and of DiaSorin EIA were 88.9% and 98.9%, respectively. Accurate results were obtained for a period of 117 days using DBS samples stored at all storage conditions, but storage at −20°C resulted in the lowest variation among the absorbance values. Both EIAs demonstrated the same limit of detection (until dilution of 1:104 with estimated viral load of 3.1 × 10−1 UI/ml), but the Radim EIA was associated with the best performance because a low coefficient of variation was observed in the repetition and reproducibility studies. In conclusion, commercial EIAs can be optimized for anti‐HCV detection in DBS samples that are extremely stable at different conditions for more than 100 days. J. Med. Virol. 84:1600–1607, 2012.


Journal of Oral Pathology & Medicine | 2012

An evaluation of different saliva collection methods for detection of antibodies against hepatitis C virus (anti-HCV)

Helena Medina Cruz; Vanessa Alves Marques; Cristiane Alves Villela-Nogueira; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

BACKGROUND Saliva samples can be used as an alternative fluid for against hepatitis C virus (anti-HCV) detection owing to the ease of collection and excellent acceptability. This study was conducted to optimize a commercial enzyme immunoassay (EIA) to detect anti-HCV in saliva samples. METHODS Ninety-six individuals donated paired serum and saliva samples that were obtained, using a commercial device (Salivette) and spitting into a sterile container. Initially, elution buffer for the Salivette samples, sample volume, incubation time and temperature, and two different anti-HCV EIAs were evaluated. Using the optimized assay, three methods for cut-off calculation were also evaluated. RESULTS A 20-fold increase in the sample volume for both collection methods was needed. Moreover, the Radim assay was the most appropriate assay for anti-HCV detection in saliva samples, and the quality parameters were increased when a ROC curve was used to determine the cut-off value. Using this optimized assay, the sensitivities, specificities, accuracies, positive and negative predictive values were above 90% for saliva obtained using both the Salivette and spitting methods. Using this assay, discordant false-negative results were obtained for only two Salivette samples and five spitting samples. The concordance kappa was 93% for the Salivette method and 86.1% for the spitting method, demonstrating excellent performance. CONCLUSIONS Saliva samples obtained for both methods can be employed for anti-HCV detection among HCV-infected or HCV-suspected cases, but several modifications must be performed on commercial EIAs to obtain good results. Moreover, samples obtained with commercial devices are more appropriate for anti-HCV detection in saliva samples.


International Journal of Environmental Research and Public Health | 2016

A Cross Section Study to Determine the Prevalence of Antibodies against HIV Infection among Hepatitis B and C Infected Individuals

Geane Lopes Flores; Adilson José de Almeida; Juliana Custódio Miguel; Helena Medina Cruz; Moyra Machado Portilho; Leticia de Paula Scalioni; Vanessa Alves Marques; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

(1) Background: There are limited data regarding human immunodeficiency virus (HIV) prevalence among hepatitis B virus (HBV) or hepatitis C virus (HCV) infected individuals. The aim of this cross-sectional study is to determine the prevalence of HBV and HCV infection among HIV individuals; (2) Methods: A total of 409 patients (126 HBV+ and 283 HCV+) referred to the Brazilian Reference Laboratory for Viral Hepatitis from 2010 to 2013 donated serum samples. Anti-HIV, HBsAg, anti-HBc, anti-HBs, anti-HBcIgM, anti-HBe, HBeAg, and anti-HCV antibodies were measured, and anti-HCV positive samples were tested for viral RNA and genotype; (3) Results: The anti-HIV antibody prevalence was 10.31% and 4.59% among HBV+ and HCV+ patients, respectively. The HCV mean (SD) viral load was log 5.14 ± 1.64 IU/mL, and genotype I was most prevalent (163/283). Anti-HBs and anti-HBc were detected in 40% and 26% of HCV+ individuals, respectively. Among the HBV+ population, the presence of anti-HIV antibodies was associated with male gender, marital status (married), tattoo, sexual orientation, sexual practices (oral sex and anal sex), history of sexually transmitted diseases (STDs), history of viral hepatitis treatment, and a sexual partner with hepatitis or HIV. For the HCV+ group, the presence of anti-HIV antibodies was associated with female gender, marital status (married), anal intercourse, previous history of STDs, and number of sexual partners; (4) Conclusion: A high prevalence of anti-HIV antibodies was found among individuals with HBV and HCV, showing the importance of education programmes towards HIV infection among HBV- and HCV-infected individuals.


Journal of Virological Methods | 2017

Performance of rapid diagnostic tests for detection of Hepatitis B and C markers in HIV infected patients

Jakeline Ribeiro Barbosa; Jeová Keny Baima Colares; Geane Lopes Flores; Vanessa Faria Cortes; Juliana Custódio Miguel; Moyra Machado Portilho; Vanessa Alves Marques; Denise Vigo Potsch; Carlos Eduardo Brandão-Mello; Marcia M. Amendola-Pires; José Henrique Pilotto; Danielle Malta Lima; Elisabeth Lampe; Livia Melo Villar

There is little information describing the influence of HIV infection upon the performance of rapid diagnostic tests (RDTs) for hepatitis B and C virus diagnosis. This study aims to evaluate the performance of RDTs for HBsAg and anti-HCV detection among HIV-infected individuals. A total of 362 HIV infected individuals were recruited from clinics between January 2013 to November 2014 in the southeast and northeast of Brazil. HBsAg and anti-HCV were detected using commercial EIAs and four RDTs: HBV (Vikia HBsAg® and Wama Imuno-Rapido HBV®) and HCV (Bioeasy Teste Rápido HCV® and Wama Imuno-Rapido HCV®). Reactive HBsAg and anti-HCV serum samples were tested for HBV DNA and HCV RNA. Sensitivity, specificity and kappa statistic were determined. Using EIA, HBsAg and anti-HCV were detected in 14 (3.9%) and 37 (10.2%) serum samples respectively. Using serum only, HBsAg RDTs demonstrated sensitivities and specificities above 92.0% and Kappa values above 89.0%. Anti-HCV RDTs demonstrated sensitivity and specificities above 82.0% and Kappa higher than 89.0%. Using whole blood samples, Vikia HBsAg® and Wama Imuno-Rapido HCV® showed sensitivity and specificity above 99.0% with Kappa of 66.4% and 100%, respectively. HIV viral load was higher among discordant results for anti-HCV RDT. RDTs demonstrated good performance in HIV infected individuals showing the usefulness of assays in this population.


Oral Diseases | 2017

Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus

Moyra Machado Portilho; Ana Carolina da Fonseca Mendonça; Vanessa Alves Marques; Leticia Cancella Nabuco; Cristiane Alves Villela-Nogueira; Claudia Ivantes; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

BACKGROUND This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. MATERIALS AND METHODS Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. RESULTS HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. CONCLUSION It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples.


Journal of Medical Virology | 2017

Performance of ANTI-HCV testing in dried blood spots and saliva according to HIV status

Geane Lopes Flores; Helena Medina Cruz; Vanessa Alves Marques; Cristiane Alves Villela-Nogueira; Denise Vigo Potsch; Silvia Beatriz May; Carlos Eduardo Brandão-Mello; Marcia Maria Amendola Pires; José Henrique Pilotto; Priscila Pollo-Flores; Eliane Bordalo Cathalá Esberard; Claudia Ivantes; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

The use of saliva and dried blood spots (DBS) could increase access to HCV diagnosis for high‐risk populations, such as HIV‐infected individuals, but the performance of these assays has not been well established in this group. This study aims to evaluate HIV status, particularly TCD4+ cell count and viral load, in the performance of anti‐HCV testing using DBS and saliva. A total of 961 individuals classified as HCV+, HIV+, or HIV/HCV+, as well as negative controls, donated serum, DBS, and saliva samples for anti‐HCV testing using a commercial enzyme immunoassay. Sample volume was modified for DBS and saliva, and an ROC curve was used for cut‐off determination in saliva. Anti‐HCV sensitivities were greater than 93% using DBS and saliva in the HCV+ group, while they were 83.3% and 95.6% for HCV/HIV+ individuals for DBS and saliva assays, respectively. Specificity varied from 91.7% to 100% using saliva and DBS in HIV monoinfected and control subjects. When only anti‐HCV/HCV RNA+ serum samples, that is, true positives, were considered, the sensitivities were 98.3% and 100% for DBS and saliva, respectively, in the HCV+ group and 91.6% and 94.8% for DBS and saliva, respectively, in the HIV/HCV+ group. High absorbance values were observed among those presenting with HCV RNA in serum and low HIV viral load (less than 50 copies/mL). In conclusion, DBS and saliva samples could be used for anti‐HCV detection, particularly to identify active HCV cases, but low sensitivity was observed for anti‐HCV testing using DBS in the HIV/HCV+ group.


International Journal of Molecular Sciences | 2017

Lack of Association between Hepatitis C Virus core Gene Variation 70/91aa and Insulin Resistance

Leticia de Paula Scalioni; Allan da Silva; Juliana Custódio Miguel; Márcia Paschoal do Espírito Santo; Vanessa Alves Marques; Carlos Eduardo Brandão-Mello; Cristiane Alves Villela-Nogueira; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

The role of hepatitis C virus (HCV) in insulin resistance (IR) is not fully understood. The aim of this study was to determine the impact of amino acid (aa) substitutions in the core region of HCV according to IR and to identify clinical and laboratory associations. Ninety-two treatment-naive HCV patients were recruited to determine laboratory data and blood cell count. IR was determined using Homeostasis Model Assessment (HOMA) index where IR was defined as HOMA ≥2. HCV RNA load and genotype were determined by Abbott Real time HCV. HCV core region was determined by direct nucleotide sequencing. Bivariate analysis was conducted using HOMA IR ≥2 as a dependent factor. IR prevalence was 43.5% (n = 40), vitamin D sufficiency was found in 76.1% (n = 70) and 72.8% (n = 67) had advanced liver fibrosis. In the bivariate analyses, elevated values of γGT (p = 0.024) and fibrosis staging (p = 0.004) were associated with IR, but IR was not related to core mutations. The presence of glutamine in position 70 was associated with low vitamin D concentration (p = 0.005). In the multivariate analysis, no variable was independently associated with HOMA-IR. In conclusion, lack of association between IR and HCV core mutations in positions 70 and 91 suggests that genetic variability of this region has little impact on IR.


Journal of Immunoassay & Immunochemistry | 2018

Comparison of the performance of enzyme immunoassays for hepatitis B and C detection in dried blood spot

Helena Medina Cruz; Juliana Custódio Miguel Cruz; Elisangela Ferreira da Silva; Moyra Machado Portilho; Vanessa Alves Marques; Lia Laura Lewis-Ximenez; Elisabeth Lampe; Livia Melo Villar

ABSTRACT Dried blood spots (DBSs) could be an alternative to serum for hepatitis B virus (HBV) and hepatitis C virus (HCV) diagnosis. This study aims to evaluate two enzyme immunoassays (EIAs) for HBsAg and anti-HCV detection using DBS. Serum was tested using commercial EIA. DBS was tested using optimized EIA developed for serum and commercial EIA developed for DBS (Imunoscreen). Concordances between DBS and serum samples for both markers and EIAs were higher than 97%. Both EIAs demonstrated good performance for HBsAg and anti-HCV detection using DBS, and these methods could be used unchangeably increasing the access for HBV and HCV diagnosis.

Collaboration


Dive into the Vanessa Alves Marques's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Cristiane Alves Villela-Nogueira

Federal University of Rio de Janeiro

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carlos Eduardo Brandão-Mello

Universidade Federal do Estado do Rio de Janeiro

View shared research outputs
Researchain Logo
Decentralizing Knowledge