Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Venita Chandra is active.

Publication


Featured researches published by Venita Chandra.


Surgery | 2010

A comparison of laparoscopic and robotic assisted suturing performance by experts and novices.

Venita Chandra; Deepika Nehra; Richard Parent; Russell Woo; Rosette Reyes; Tina Hernandez-Boussard; Sanjeev Dutta

BACKGROUND Surgical robotics has been promoted as an enabling technology. This study tests the hypothesis that use of the robotic surgical system can significantly improve technical ability by comparing the performance of both experts and novices on a complex laparoscopic task and a robotically assisted task. METHODS Laparoscopic experts (LE) with substantial laparoscopic and robotic experience (n = 9) and laparoscopic novices (LN) (n = 20) without any robotic experience performed sequentially 10 trials of a suturing task using either robotic or standard laparoscopic instrumentation fitted to the ProMIS surgical simulator. Objective performance metrics provided by ProMIS (total task time, instrument pathlength, and smoothness) and an assessment of learning curves were analyzed. RESULTS Compared with LNs, the LEs demonstrated significantly better performance on all assessment measures. Within the LE group, there was no difference in smoothness (328 +/- 159 vs 355 +/- 174; P = .09) between robot-assisted and standard laparoscopic tasks. An improvement was noted in total task time (113 +/- 41 vs 132 +/- 55 sec; P < .05) and instrument pathlengths (371 +/- 163 vs 645 +/- 269 cm; P < .05) when using the robot. This advantage in terms of total task time, however, was lost among the LEs by the last 3 trials (114 +/- 40 vs 118 +/- 49 s; P = .84), while instrument pathlength remained better consistently throughout all the trials. For the LNs, performance was significantly better in the robotic trials on all 3 measures throughout all the trials. CONCLUSION The ProMIS surgical simulator was able to distinguish between skill levels (expert versus novice) on robotic suturing tasks, suggesting that the ProMIS is a valid tool for measuring skill in robot-assisted surgery. For all the ProMIS metrics, novices demonstrated consistently better performance on a suturing task using robotics as compared to a standard laparoscopic setup. This effect was less evident for experts who demonstrated improvements only in their economy of movement (pathlength), but not in the speed or smoothness of performance. Robotics eliminated the early learning curve for novices, which was present when they used standard laparoscopic tools. Overall, this study suggests that, when performing complex tasks such as knot tying, surgical robotics is most useful for inexperienced laparoscopists who experience an early and persistent enabling effect. For experts, robotics is most useful for improving economy of motion, which may have implications for the highly complex procedures in limited workspaces (eg, prostatectomy).


Archive | 2008

Robotics in General Surgery

James Wall; Venita Chandra; Thomas M. Krummel

Find the secret to improve the quality of life by reading this robotics in general surgery. This is a kind of book that you need now. Besides, it can be your favorite book to read after having this book. Do you ask why? Well, this is a book that has different characteristic with others. You may not need to know who the author is, how well-known the work is. As wise word, never judge the words from who speaks, but make the words as your good value to your life.


Journal of Vascular Surgery | 2010

Long-Term Impact of a Preclinical Endovascular Skills Course on Medical Student Career Choices

Jason T. Lee; Ji H. Son; Venita Chandra; Emily Lilo; Ronald L. Dalman

OBJECTIVE Surging interest in the 0 + 5 integrated vascular surgery (VS) residency and successful recruitment of the top students in medical school requires early exposure to the field. We sought to determine the impact of a high-fidelity simulation-based preclinical endovascular skills course on medical student performance and ultimate career specialty choices. METHODS Fifty-two preclinical medical students enrolled in an 8-week VS elective course from 2007 to 2009. Students completed a baseline and postcourse survey and performed a renal angioplasty/stent procedure on an endovascular simulator (pretest). A curriculum consisting of didactic teaching covering peripheral vascular disease and weekly mentored simulator sessions concluded with a final graded procedure (posttest). Long-term follow-up surveys 1 to 3 years after course completion were administered to determine ultimate career paths of participants as well as motivating factors for career choice. RESULTS Objective and subjective performance measured on the simulator and through structured global assessment scales improved in all students from pre- to posttest, particularly with regard to technical skill and overall procedural competency (P < .001). Prior to enrolling in the course, 9% of the students expressed high interest in VS, and after completing the course, this response nearly tripled in terms of seriously considering VS as a career option (P = .03). Overall interest postcourse in VS and procedural-based surgical specialties was nearly 90%. In long-term follow-up, 25% were still strongly considering integrated VS residencies, with other top career choices including surgical subspecialties (64%), radiology (10%), and cardiology (6%). Most respondents indicated major reasons for continued interest in VS were the ability to practice endovascular procedures on the simulator (92%) and mentorship from VS faculty (70%). CONCLUSIONS Basic endovascular skills can be efficiently introduced through a simulation-based curriculum and lead to improved novice performance. Early exposure of preclinical medical students provides an effective teaching and recruitment tool for procedural-based fields, particularly surgical subspecialties. Mentored exposure to endovascular procedures on the simulator positively impacts long-term medical student attitudes toward vascular surgery and ultimate career choices.


Journal of Vascular Surgery | 2011

Early results of a highly selective algorithm for surgery on patients with neurogenic thoracic outlet syndrome

Venita Chandra; Cornelius Olcott; Jason T. Lee

OBJECTIVE Neurogenic thoracic outlet syndrome (nTOS) encompasses a wide spectrum of disabling symptoms that are often vague and difficult to diagnose and treat. We developed and prospectively analyzed a treatment algorithm for nTOS utilizing objective disability criteria, thoracic outlet syndrome (TOS)-specific physical therapy, radiographic evaluation of the thoracic outlet, and selective surgical decompression. METHODS Patients treated for nTOS from 2000-2009 were reviewed (n = 93). In period 1, most patients were offered surgery with documentation of appropriate symptoms. A prospective observational study began in 2007 (period 2) and was aimed at determining which patients benefited most from surgical intervention. Evaluation began with a validated mini-QuickDASH (QD) quality-of-life scale (0-100, 100 = worse) and duplex imaging of the thoracic outlet. Patients then participated in TOS-specific physical therapy (PT) for 2 to 4 months and were offered surgery based on response to PT and improvement in symptoms. RESULTS Thirty-four patients underwent first rib resection in period 1 (68% female, mean age 39, 18% athletes, 15% workers comp). In operated patients undergoing duplex imaging, 47% showed compression of their thoracic outlet arterial flow on provocative positioning. Based on subjective improvement of symptoms, 56% of patients at 1 year had a positive outcome. In period 2 during the prospective cohort, 59 consecutive patients were evaluated for nTOS (64% female, mean age 36, 32% athletes, 12% workers comp) with a mean pre-PT QD disability score of 55.1. All patients were prescribed PT, and 24 (41%) were eventually offered surgical decompression based on compliance with PT, interval improvement on QD score, and duplex compression of the thoracic outlet. Twenty-one patients underwent surgery (SURG group) consisting of first rib resection, middle and anterior scalenectomy, and brachial plexus neurolysis. There were significant differences between the SURG and non-SURG cohorts with respect to age, participation in competitive athletics, history of trauma, and symptom improvement with PT. At 1-year follow-up, 90% of patients expressed symptomatic improvement with the mean post-op QD disability score decreasing to 24.9 (P = .005) and 1-year QD scores improving down to 20.5 (P = .014). CONCLUSIONS This highly-selective algorithm for nTOS surgery leads to improvement in overall success rates documented subjectively and objectively. Compliance with TOS-specific PT, improvement in QD scores after PT, young age, and competitive athletics are associated with improved surgical outcomes. Long-term follow-up will be necessary to document sustained symptom relief and to determine who the optimal surgical candidates are.


Journal of Endovascular Therapy | 2015

Impact of Renal Artery Angulation on Procedure Efficiency During Fenestrated and Snorkel/Chimney Endovascular Aneurysm Repair.

Brant W. Ullery; Venita Chandra; Ronald L. Dalman; Jason T. Lee

Purpose: To determine the impact of renal artery angulation on time to successful renal artery cannulation and procedure efficiency during fenestrated and snorkel/chimney endovascular aneurysm repair (EVAR). Methods: The imaging and procedure logs of 77 patients (mean age 74.2 years; 63 men) who underwent complex EVAR (24 fenestrated, 53 snorkel/chimney) from 2009 to 2013 were reviewed. Renal artery angulation was measured on preoperative computed tomographic angiography scans. Time to renal artery cannulation was retrieved from the EVAR procedure logs and compared to preoperative renal artery angulation and other metrics of procedure efficiency (eg, procedure time, fluoroscopy time, blood loss, etc). In all, 111 renal arteries were available for renal artery angulation measurement (39 fenestrated, 72 snorkel/chimney); 22 renal cannulations were inappropriate for the comparative analyses due to concomitant visceral artery stenting (n=15), combined procedures (n=6), or unsuccessful cannulation (n=1). Results: For patients undergoing fenestrated EVAR, mean renal artery angulation was -28°±21° (range +37° to -60°), not significantly different (p=0.66) from patients receiving snorkel/chimney grafts (mean -30°±19°, range +22° to -65°). Comparative analysis using median renal artery angulation (−30° for both groups) demonstrated that renal artery cannulation during fenestrated EVAR was performed significantly faster in arteries with less downward (≥ −30°) angulation (16.0 vs 32.8 minutes, p=0.04), whereas cannulation in snorkel/chimneys was faster in arteries with greater downward (< −30°) angulation (10.9 vs 17.3 minutes, p=0.05). Fenestrated EVAR cases involving less downward (≥ −30°) renal artery angulation were also associated with shorter overall procedure time (187.7 vs 246.2 minutes, p=0.01) and decreased fluoroscopy time (70.3 vs 98.2 minutes, p=0.04). Immediate renal function decline, procedural complications, and postoperative issues were not associated with renal artery angulation. Conclusion: Procedural efficiency may be optimized by considering renal artery angulation as one of several objective variables used in the selection of an appropriate endovascular strategy. The fenestrated approach is more efficient with less downward angulation to the renal arteries, while the snorkel/chimney strategy is facilitated by more downward renal artery angulation.


Journal of Vascular Surgery | 2012

Monitoring of fetal radiation exposure during pregnancy.

Venita Chandra; Chelsea Dorsey; Amy B. Reed; Palma Shaw; Dawn Banghart; Wei Zhou

BACKGROUND One unique concern of vascular surgeons and trainees is radiation exposure associated with increased endovascular practice. The safety of childbearing is a particular worry for current and future women in vascular surgery. Little is known regarding actual fetal radiation exposure. This multi-institutional study aimed to evaluate the radiation dosages recorded on fetal dosimeter badges and compare them to external badges worn by the same cohort of women. METHODS All women who declared pregnancy with potential radiation exposure were required to wear two radiation monitors at each institution, one outside and the other inside the lead apron. Maternal (external) and fetal monitor dosimeter readings were analyzed. Maternal radiation exposures prior to, during, and postpregnancy were also assessed to determine any associated behavior modification. RESULTS Eighty-one women declared pregnancy from 2008 to 2011 and 32 had regular radiation exposure during pregnancy. Maternal whole-body exposures ranged from 21-731 mrem. The average fetal dosimeter recordings for the cohort rounded to zero. Only two women had positive fetal dosimeter recordings; one had a single recording of 3 mrem and the other had a single recording of 7 mrem. There was no significant difference between maternal exposures prior to, during, and postpregnancy. CONCLUSIONS Lack of knowledge of fetal radiation exposure has concerned many vascular surgeons, prompting them to wear double lead aprons during pregnancy, and perhaps prevented numerous other women from entering the field. Our study showed negligible radiation exposure on fetal monitoring suggesting that with the appropriate safety precautions, these concerns may be unwarranted.


Journal of Surgical Oncology | 2012

Preoperative embolization of replaced right hepatic artery prior to pancreaticoduodenectomy

Jordan M. Cloyd; Venita Chandra; John D. Louie; Sekhar Rao; Brendan C. Visser

Aberrancy of the hepatic arterial anatomy is common. Because of its course directly adjacent to the head of the pancreas, a replaced right hepatic artery (RHA) is vulnerable to invasion by peri‐pancreatic malignancies. Division of the RHA at the time of pancreaticoduodenectomy, however, may result in hepatic infarction and/or bilioenteric anastomotic complications. We report two cases of patients undergoing preoperative embolization of tumor encased replaced RHAs to allow for sufficient collateralization prior to pancreaticoduodenectomy. J. Surg. Oncol. 2012; 106:509–512.


Journal of Vascular Surgery | 2016

Unplanned reoperations after vascular surgery

Hadiza S. Kazaure; Venita Chandra; Matthew W. Mell

OBJECTIVE Existing literature on unplanned reoperation (UR) after vascular surgery is limited. The frequency of 30-day UR and its association with other adverse outcomes was analyzed. METHODS Patients who underwent vascular procedures in the American College of Surgeons National Surgical Quality Improvement Program (2012) were abstracted. UR, captured by a distinct variable now available in the data set, and its association with complications, readmissions, mortality, and failure to rescue (FTR) were analyzed using bivariate and multivariate methods. RESULTS Among 35,106 patients, 3545 URs were performed on 2874 patients. The overall UR rate was 10.1%. Among patients who underwent URs, approximately 80.4%, 15.8%, and 3.8% had one, two, and three or more reoperations, respectively; 39.4% of URs occurred after initial discharge. Median time to UR was 7 days but varied by procedure. Procedures with the highest UR rates were embolectomy (18.2%), abdominal bypass (14.4%), and open procedures for peripheral vascular disease (13.8%). Common indications for UR were hemorrhage, graft failure or infection, thromboembolic events, and wound complications. Patients with URs had higher rates of subsequent complications (49.9% vs 19.9%; P < .001), readmission (41.8% vs 7.0%; P < .001), and mortality (8.0% vs 2.5%; P < .001) than those not undergoing URs. FTR was more likely among patients who had a UR (13.6% vs 9.3%; P < .001); this varied within procedure groups. After multivariate adjustment, UR was independently associated with mortality in an incremental fashion (for one UR: adjusted odds ratio, 2.0; 95% confidence interval, 1.7-2.5; for two or more URs: adjusted odds ratio, 3.1; 95% confidence interval, 2.2-4.2). CONCLUSIONS URs within 30 days are frequent among patients undergoing vascular surgery and are associated with worse outcomes, including mortality and FTR.


Annals of Vascular Surgery | 2015

Aortoiliac Elongation after Endovascular Aortic Aneurysm Repair

Venita Chandra; Martin Rouer; Trit Garg; Dominik Fleischmann; Matthew W. Mell

BACKGROUND Aortoiliac elongation after endovascular aortic aneurysm repair (EVAR) is not well studied. We sought to assess the long-term morphologic changes after EVAR and identify potentially modifiable factors associated with such a change. METHODS An institutional review board-approved retrospective review was conducted for 88 consecutive patients who underwent EVAR at a single academic center from 2003 to 2007 and who also had at least 2 follow-up computed tomography angiograms (CTAs) available for review up to 5 years after surgery. Standardized centerline aortic lengths and diameters were obtained on Aquarius iNtuition 3D workstation (TeraRecon Inc., San Mateo, CA) on postoperative and all-available follow-up CTAs. Relationships to aortic elongation were determined using Wilcoxon rank-sum test or linear regression (Stata version 12.1, College Station, TX). Changes in length over time were determined by mixed-effects analysis (SAS version 9.3, Cary, NC). RESULTS The study cohort was composed of mostly men (88%), with a mean age of (76 ± 8) and a mean follow-up of 3.2 years (range, 0.4-7.5 years). Fifty-seven percent of patients (n = 50) had devices with suprarenal fixation and 43% (n = 38) had no suprarenal fixation. Significant lengthening was observed over the study period in the aortoiliac segments, but not in the iliofemoral segments. Aortoiliac elongation over time was not associated with sex (P = 0.3), hypertension (P = 0.7), coronary artery disease (P = 0.3), diabetes (P = 0.3), or tobacco use (P = 0.4), but was associated with the use of statins (P = 0.03) and the presence of chronic obstructive pulmonary disease (P = 0.02). Significant aortic lengthening was associated with increased type I endoleaks (P = 0.03) and reinterventions (P = 0.03). Over the study period, 4 different devices were used; Zenith (Cook Medical Inc., Bloomington, IN), Talent (Medtronic, Minneapolis, MN), Aneuryx (Medtronic), and Excluder (W. L. Gore and Associates Inc., Flagstaff, AZ). After adjusting for differences in proximal landing zone, significant differences in aortic lengthening over time were observed by device type (P = 0.02). CONCLUSIONS Significant aortoiliac elongation was observed after EVAR. Such morphologic changes may impact long-term durability of EVAR, warranting further investigation into factors associated with these morphologic changes.


Annals of Vascular Surgery | 2012

Cost Impact of Extension Cuff Utilization During Endovascular Aneurysm Repair

Venita Chandra; Joshua I. Greenberg; Weesam K. Al-Khatib; E. John Harris; Ronald L. Dalman; Jason T. Lee

BACKGROUND Modular stent-graft systems for endovascular aneurysm repair (EVAR) most often require two to three components, depending on the device. Differences in path lengths and availability of main body systems often require additional extensions for appropriate aneurysm exclusion. These additional devices usually result in added expenses and can affect the financial viability of an EVAR program within a hospital. The purpose of this study was to analyze the use of extensions during EVAR, focusing on incidence, clinical impact, and financial impact, as well as determining the associated cost differences between two- and three-component EVAR device systems. METHODS We reviewed available clinical data, images, and follow-up of 218 patients (203 males and 15 females, mean age: 74 ± 9 years) who underwent elective EVAR at a single academic center from 2004 to 2007. Patients were divided into two groups: patients undergoing EVAR using the standard number of pieces, that is, no extensions used (group A, n = 98), and those needing proximal or distal extensions during the index procedure (group B, n = 120). RESULTS Both groups were similar in terms of demographics; preoperative characteristics, including aneurysm morphology; as well as intraoperative, postoperative, and midterm outcomes. Overall, 30-day operative mortality was 1.4%, with a mean follow-up of 24 months. Group A patients underwent repair with two-piece modular devices 41% of the time and three-piece systems 59% of the time, whereas group B patients underwent repair with two-piece modular systems 82% of the time and three-piece modular systems 18% of the time. The number of additional extensions per patient ranged from one to four (median: one piece). There was a 30% cost increase in overall mean device-related cost when using extensions versus the standard number of pieces (group A:

Collaboration


Dive into the Venita Chandra's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge