Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Vicente Martín-Montañez is active.

Publication


Featured researches published by Vicente Martín-Montañez.


American Journal of Ophthalmology | 2014

Dry eye exacerbation in patients exposed to desiccating stress under controlled environmental conditions.

Alberto López-Miguel; Marisa Tesón; Vicente Martín-Montañez; Amalia Enríquez-de-Salamanca; Michael E. Stern; Margarita Calonge; María J. González-García

PURPOSE To determine if controlled environmental conditions can induce acute exacerbations of signs and symptoms in dry eye and asymptomatic subjects. DESIGN Prospective cross-sectional study. METHODS Nineteen patients with dry eye and 20 asymptomatic controls were exposed to controlled low humidity (5% relative humidity, desiccating environment) for 2 hours in our Controlled Environmental Research Laboratory at the University of Valladolid. The patients completed the Single-Item Score Dry Eye Questionnaire and the following diagnostic tests were performed before and after exposure: tear osmolarity, phenol red thread test, conjunctival hyperemia, fluorescein tear film break-up time, Schirmer test, and ocular surface vital staining. Sixteen molecules in the tears samples were analyzed by multiplex bead analysis. RESULTS After exposure, the patients and controls had a significant (P ≤ .003) increase in corneal staining (from 0.68 ± 0.15 to 1.16 ± 0.14 and from 0.50 ± 0.15 to 1.30 ± 0.19, respectively), significantly decreased (P ≤ .01) fluorescein tear film break-up time values (from 2.78 ± 0.56 seconds to 1.94 ± 0.24 seconds and from 2.81 ± 0.24 seconds to 2.13 ± 0.19 seconds, respectively), and significantly increased (P ≤ .03) matrix metalproteinase 9 tear levels (from 10 054.4 ± 7326.6 pg/mL to 25 744.5 ± 13 212.4 pg/mL and from 10 620.5 ± 4494.3 pg/mL to 16 398.7 ± 5538.3 pg/mL, respectively). In the control group, the epidermal growth factor tear levels decreased significantly (P = .007; from 1872.1 ± 340.7 pg/mL to 1107.1 ± 173.6 pg/mL), and interleukin 6 levels increased significantly (P < .001; from 29.6 ± 5.8 pg/mL to 54.3 ± 8.3 pg/mL) after exposure. CONCLUSIONS Adult patients with mild-to-moderate dry eye and asymptomatic subjects of similar ages can experience acute exacerbation in an environmental chamber that resembles the sudden worsening that patients with dry eye experience daily.


Investigative Ophthalmology & Visual Science | 2013

Influence of a Controlled Environment Simulating an In-Flight Airplane Cabin on Dry Eye Disease

Marisa Tesón; María J. González-García; Alberto López-Miguel; Amalia Enríquez-de-Salamanca; Vicente Martín-Montañez; María Jesús Benito; María Eugenia Mateo; Michael E. Stern; Margarita Calonge

PURPOSE To evaluate symptoms, signs, and the levels of 16 tears inflammatory mediators of dry eye (DE) patients exposed to an environment simulating an in-flight air cabin in an environmental chamber. METHODS Twenty DE patients were exposed to controlled environment simulating an in-flight airplane cabin (simulated in-flight condition [SIC]) of 23°C, 5% relative humidity, localized air flow, and 750 millibars (mb) of barometric pressure. As controls, 15 DE patients were subjected to a simulated standard condition (SSC) of 23°C, 45% relative humidity, and 930 mb. A DE symptoms questionnaire, diagnostic tests, and determination of 16 tear molecules by multiplex bead array were performed before and 2 hours after exposure. RESULTS After SIC exposure, DE patients became more symptomatic, suffered a significant (P ≤ 0.05) decrease in tear stability (tear break up time) (from 2.18 ± 0.28 to 1.53 ± 0.20), and tear volume (phenol red thread test), and a significant (P ≤ 0.05) increase in corneal staining, both globally (0.50 ± 0.14 before and 1.25 ± 0.19 after) and in each area (Baylor scale). After SSC, DE patients only showed a mild, but significant (P ≤ 0.05), increase in central and inferior corneal staining. Consistently, tear levels of IL-6 and matrix metalloproteinase (MMP)-9 significantly increased and tear epidermal growth factor (EGF) significantly decreased (P ≤ 0.05) only after SIC. CONCLUSIONS The controlled adverse environment conditions in this environmental chamber can simulate the conditions in which DE patients might be exposed during flight. As this clearly impaired their lacrimal functional unit, it would be advisable that DE patients use therapeutic strategies capable of ameliorating these adverse episodes.


American Journal of Ophthalmology | 2016

Clinical and Molecular Inflammatory Response in Sjögren Syndrome-Associated Dry Eye Patients Under Desiccating Stress.

Alberto López-Miguel; Marisa Tesón; Vicente Martín-Montañez; Amalia Enríquez-de-Salamanca; Michael E. Stern; María J. González-García; Margarita Calonge

PURPOSE To evaluate the response of the lacrimal function unit in Sjögren syndrome (SS)-associated dry eye patients exposed to 2 simulated daily life environmental conditions. DESIGN Prospective crossover pilot study. METHODS Fourteen female SS dry eye patients were exposed for 2 hours to a controlled normal condition (23 C, 45% relative humidity, and air flow 0.10 m/s) and a controlled adverse condition that simulates desiccating stress (23 C, 5% relative humidity, and air flow 0.10 m/s). The following dry eye tests were performed before and after the exposure: tear osmolarity, phenol red thread test, conjunctival hyperemia, fluorescein tear break-up time, corneal fluorescein staining, conjunctival lissamine green staining, and Schirmer test. Levels of 16 molecules were analyzed in tears by multiplex immunobead analysis. RESULTS Clinical evaluation showed lacrimal functional unit impairment after the desiccating stress: significantly increased tear osmolarity (315.7 ± 3.0 vs 327.7 ± 5.1 mOsm/L, P = .03), conjunctival hyperemia (1.3 ± 0.1 vs 1.6 ± 0.1, P = .05), and corneal staining in temporal (3.5 ± 0.5 vs 4.7 ± 0.4, P = .01) and nasal (3.6 ± 0.5 vs 4.5 ± 0.5, P = .04) areas. Tear concentrations increased for interleukin-1 receptor antagonist (16 557.1 ± 4047.8 vs 31 895.3 ± 5916.5 pg/mL, P = .01), interleukin-6 (63.8 ± 20.2 vs 111.5 ± 29.6 pg/mL, P = .02), interleukin-8 (2196.1 ± 737.9 vs 3753.2 ± 1106.0 pg/mL, P = .03), and matrix metalloproteinase-9 (101 515.6 ± 37 088.4 vs 145 867.1 ± 41 651.5 pg/mL, P = .03). After the simulated normal condition, only a significant increase in nasal corneal staining (2.9 ± 0.5 vs 3.6 ± 0.5, P = .03) was observed. CONCLUSIONS Even a short exposure to a desiccating environment can produce a significant deterioration of the lacrimal function unit in female SS dry eye patients. The often unnoticed exposure to these conditions during daily life may increase inflammatory activity rapidly, triggering an ocular surface deterioration.


Journal of Biomedical Materials Research Part B | 2014

Influence of environmental factors in the in vitro dehydration of hydrogel and silicone hydrogel contact lenses

Vicente Martín-Montañez; Alberto López-Miguel; Cristina Arroyo; María Eugenia Mateo; José Manuel González-Méijome; Margarita Calonge; María J. González-García

PURPOSE To analyze in vitro the influence of different environmental conditions on the dehydration pattern of seven currently marketed hydrogel (Hy) and silicone hydrogel (Si-Hy) contact lenses (CL). METHODS Three Hy and four Si-Hy CLs were evaluated. CLs were exposed to four different relative humidity (RH) conditions (5%, 30%, 50%, and 70%) and two air flow (AF) rates (0 and 2.75 m/seg) within an environmental chamber. Dehydration was assessed using the gravimetric method. Data were taken at baseline, 5, 10, 15, 20, 30, 45, 60, 90, and 120 minutes of exposure. Dehydration rate (DR), valid dehydration (VD) and stabilization time were calculated. RESULTS The interaction between RH, AF and the type of the CL material had a significant effect (p ≤ 0.03) on DR up to 60 minutes. The maximum differences in VD values among CL occurred around 15 minutes exposure varying from 25.16% to 42.75%. Stabilization time was quicker under the 5%RH with AF condition than under 70% RH without AF one for most CLs. CONCLUSIONS Lower RH seems to increase CL dehydration being further accelerated with the AF presence. The dehydration pattern is material dependent, thus current marketed CLs behave differently under several controlled environmental conditions. Future in vivo studies should confirm these outcomes.


Cornea | 2016

Effect of environmental conditions on the concentration of tear inflammatory mediators during contact lens wear

Vicente Martín-Montañez; Amalia Enríquez-de-Salamanca; Alberto López-de la Rosa; Alberto López-Miguel; Itziar Fernández; Margarita Calonge; José Manuel González-Méijome; María J. González-García

Purpose: To analyze the influence of environmental conditions on the concentrations of tear inflammatory mediators during contact lens (CL) wear. Methods: Fifty-four CL wearers completed 4 visits combining the bilateral use of omafilcon A or comfilcon A CL and a 90-minute exposure to 2 environmental conditions: standard [50% relative humidity (RH), 23°C, 930 mb] or adverse (5% RH, localized air flow, 23°C, 750 mb). Four microliters of tears was collected by capillarity from each subject. Changes in concentration of epidermal growth factor (EGF); interleukin (IL)-1 receptor antagonist, IL-1&bgr;, IL-2, IL-4, IL-6, and IL-8; tumor necrosis factor (TNF) &agr;; monocyte chemoattractant protein-1; and matrix metalloproteinase (MMP)-9 were analyzed. The effects of the environment, CL type, and symptoms were evaluated using a 3-way mixed analysis of variance with repeated measures. Results: Under the standard condition, EGF significantly increased [0.36; 95% confidence interval (CI), 0.08 to 0.64], and IL-1&bgr; (−0.48; 95% CI, −0.84 to −0.12) and IL-2 (−0.48; 95% CI, −0.87 to −0.09) significantly decreased. Under the adverse condition, IL-6 significantly increased (0.35; 95% CI, 0.09 to 0.62). Comparing conditions, EGF change was significantly lower (P = 0.02) and IL-1&bgr;, IL-2, IL-6, and TNF-&agr; changes were significantly higher (P ⩽ 0.04) under the adverse condition. Additionally, IL-1&bgr; significantly decreased with comfilcon A (−0.51; 95% CI, −0.88 to −0.15), being significantly lower (P = 0.01) than the change with omafilcon A (0.06; 95% CI, −0.23 to 0.35). Conclusions: The secretion of several tear inflammatory mediators during CL wear differs depending on the environmental conditions and the CL type used. These outcomes might help to understand the effect of the environment and CL materials on the ocular surface of CL wearers.


Contact Lens and Anterior Eye | 2015

End-of-day dryness, corneal sensitivity and blink rate in contact lens wearers

Vicente Martín-Montañez; Alberto López-de la Rosa; Alberto López-Miguel; José Pinto-Fraga; José Manuel González-Méijome; María J. González-García

PURPOSE To study the relationship among the variables intensity of the end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. METHODS Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1±7.2 years) were enrolled. EOD dryness was assessed using a scale of 0-5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmontes gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. RESULTS A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: -0.39; p=0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p<0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. CONCLUSIONS CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms.


Contact Lens and Anterior Eye | 2016

Effect of the osmolarity change in multipurpose solutions induced by an improper contact lens case cleaning procedure

José Pinto-Fraga; Antonio Abengózar-Vela; Alberto López-Miguel; Vicente Martín-Montañez; Alberto López-de la Rosa; María J. González-García

PURPOSE To determine whether variations in multipurpose disinfecting solution (MPDS) storage osmolarity from inappropriate contact lens (CL) case cleaning affect ocular surface integrity and wearer comfort. METHODS There were twenty contact lens cases (study CLCs) in the study group. Ten were filled with ReNu Multiplus(®) and 10 with SoloCare Aqua™ (MPDS-1 and -2, respectively) and kept closed for 8h; the cases were then emptied and kept open for air-drying for 16h. This procedure was carried out every day for two months. Storage solution osmolarity was measured on days 0, 15, 30, 45 and 60. Ten subjects were then fitted with both month-old lenses stored in the study CLCs and with new lenses stored in new cases with fresh solution for 24h (control CLCs). Symptoms, tear osmolarity and percentage of subjects whose conjunctival hyperaemia and ocular surface staining scores changed were determined after 1h of wear. RESULTS Study CLC osmolarity increased in both solutions after two months (p<0.05). For MPDS-1 there were differences in stinging between study CLCs and control CLCs after 10min of CL wear (p=0.04), and in comfort after 10 (p=0.035) and 60min wear (p=0.042). Significant (p<0.05) differences between study CLC and control CLC groups were also found for MPDS-2 in limbal hyperaemia (study: 50% change; control: 0% change) and bulbar and corneal staining (study: 80% change; control: 20% change). CONCLUSION The stored-MPDS osmolarity increase caused by air-drying the CLCs could affect the ocular surface. This increase might reduce lens wear comfort.


Ophthalmic and Physiological Optics | 2017

Ocular response to environmental variations in contact lens wearers

Alberto López-de la Rosa; Vicente Martín-Montañez; Alberto López-Miguel; Itziar Fernández; Margarita Calonge; José Manuel González-Méijome; María J. González-García

To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers.


Contact Lens and Anterior Eye | 2018

Tear film stability and ex vivo dehydration of two novel daily disposable contact lenses

Vicente Martín-Montañez; Rute Ferreira Macedo de Araújo; Laura Rico-del-Viejo; María J. González-García; José Manuel González-Méijome


Contact Lens and Anterior Eye | 2018

Effect of the environmental conditions on tear inflammatory mediators concentration in contact lens wearers

María J. González-García; Vicente Martín-Montañez; Alberto López-Miguel; Itziar Fernández; Alberto López-de-la-Rosa; Francisco J. Pinto-Fraga; Amalia Enríquez-de-Salamanca; Carmen García-Vázquez

Collaboration


Dive into the Vicente Martín-Montañez's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marisa Tesón

University of Valladolid

View shared research outputs
Top Co-Authors

Avatar

Michael E. Stern

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge