Vinay Kansal
University of Ottawa
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Vinay Kansal.
Journal of the American Heart Association | 2016
Trevor Simard; Benjamin Hibbert; Madhu K. Natarajan; Mathew Mercuri; Simon Hetherington; Robert A. Wright; Ronak Delewi; Jan J. Piek; Ralf Lehmann; Zoltán Ruzsa; Helmut W. Lange; Håkan Geijer; Michael Sandborg; Vinay Kansal; Jordan Bernick; Pietro Di Santo; Ali Pourdjabbar; F. Daniel Ramirez; Benjamin J.W. Chow; Aun-Yeong Chong; Marino Labinaz; Michel R. Le May; Edward R. O'Brien; George A. Wells; Derek So
Background The adoption of the transradial (TR) approach over the traditional transfemoral (TF) approach has been hampered by concerns of increased radiation exposure—a subject of considerable debate within the field. We performed a patient‐level, multi‐center analysis to definitively address the impact of TR access on radiation exposure. Methods and Results Overall, 10 centers were included from 6 countries—Canada (2 centers), United Kingdom (2), Germany (2), Sweden (2), Hungary (1), and The Netherlands (1). We compared the radiation exposure of TR versus TF access using measured dose‐area product (DAP). To account for local variations in equipment and exposure, standardized TR:TF DAP ratios were constructed per center with procedures separated by coronary angiography (CA) and percutaneous coronary intervention (PCI). Among 57 326 procedures, we demonstrated increased radiation exposure with the TR versus TF approach, particularly in the CA cohort across all centers (weighted‐average ratios: CA, 1.15; PCI, 1.05). However, this was mitigated by increasing TR experience in the PCI cohort across all centers (r=−0.8; P=0.005). Over time, as a center transitioned to increasing TR experience (r=0.9; P=0.001), a concomitant decrease in radiation exposure occurred (r=−0.8; P=0.006). Ultimately, when a centers balance of TR to TF procedures approaches 50%, the resultant radiation exposure was equivalent. Conclusions The TR approach is associated with a modest increase in patient radiation exposure. However, this increase is eliminated when the TR and TF approaches are used with equal frequency—a guiding principle for centers adopting the TR approach.
SAGE open medical case reports | 2016
Vinay Kansal; Sudhir Nagpal
Objectives: To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. Methods: A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. Results: Seven years after the initial repair, imaging surveillance revealed significant endoleak and brisk aneurysm sac expansion due to Type IIIb endoleak secondary to endograft limb fabric tear. Conclusions: This case illustrates the imperative role of imaging surveillance in detection of long-term endovascular aneurysm repair complications. Furthermore, we discuss exclusion of the graft tear with aortouniiliac stent grafting as the treatment for this complication.
Vascular | 2017
Vinay Kansal; Prasad Jetty; Dalibor Kubelik; George Hajjar; Andrew Hill; Tim Brandys; Sudhir Nagpal
Endovascular aneurysm repairs lacking suitable common iliac artery landing zones occasionally require graft limb extension into the external iliac artery, covering the internal iliac artery origin. The purpose of this study was to assess incidence of type II endoleak following simple coverage of internal iliac artery without embolization during endovascular aneurysm repair. Three hundred eighty-nine endovascular aneurysm repairs performed by a single surgeon (2004–2015) were reviewed. Twenty-seven patients underwent simple internal iliac artery coverage. Type II endoleak was assessed from operative reports and follow-up computed tomography imaging. No patient suffered type II endoleak from a covered internal iliac artery in post-operative computed tomography scans. Follow-up ranged from 0.5 to 9 years. No severe pelvic ischemic complications were observed. In conclusion, for selected cases internal iliac artery coverage without embolization is a safe alternative to embolization in endovascular aneurysm repairs, where the graft must be extended into the external iliac artery.
Respiratory medicine case reports | 2015
Vinay Kansal; Sudhir Nagpal
We report a case of a 46-year old man who presented with spontaneous bright red blood per mouth for several months. The patient had history of aortic coarctation repair at age 17. Endoscopy and nasopharyngeoscopy revealed no source of bleeding. Computed tomography scan revealed the presence of thoracic aortic pseudoaneurysm with the formation of an aortobronchial fistula (ABF). This case illustrates the high index of suspicion for ABF in the case of hemoptysis or hematemesis with prior history of coarctation repair. Furthermore, we discuss the role of thoracic endovascular aneurysm repair (TEVAR) as the standard of repair over open surgery.
Vascular | 2017
Vinay Kansal; Sudhir Nagpal; Prasad Jetty
Objective Endovascular aneurysm repair for ruptured abdominal aortic aneurysm is being increasingly applied as the intervention of choice. The purpose of this study was to determine whether survival and reintervention rates after ruptured abdominal aortic aneurysm vary between endograft devices. Methods This cohort study identified all ruptured abdominal aortic aneurysms performed at The Ottawa Hospital from January 1999 to May 2015. Data collected included patient demographics, stability index at presentation, adherence to device instructions for use, endoleaks, reinterventions, and mortality. Kruskal–Wallis test was used to compare outcomes between groups. Mortality outcomes were assessed using Kaplan–Meier survival analysis, and multivariate Cox regression modeling. Results One thousand sixty endovascular aneurysm repairs were performed using nine unique devices. Ninety-six ruptured abdominal aortic aneurysms were performed using three devices: Cook Zenith (n = 46), Medtronic Endurant (n = 33), and Medtronic Talent (n = 17). The percent of patients presented in unstable or extremis condition was 30.2, which did not differ between devices. Overall 30-day mortality was 18.8%, and was not statistically different between devices (p = 0.16), although Medtronic Talent had markedly higher mortality (35.3%) than Cook Zenith (15.2%) and Medtronic Endurant (15.2%). AUI configuration was associated with increased 30-day mortality (33.3% vs. 12.1%, p = 0.02). Long-term mortality and graft-related reintervention rates at 30 days and 5 years were similar between devices. Instructions for use adherence was similar across devices, but differed between the ruptured abdominal aortic aneurysm and elective endovascular aneurysm repair cohorts (47.7% vs. 79.0%, p < 0.01). Notably, two patients who received Medtronic Talent grafts underwent open conversion >30 days post-endovascular aneurysm repair (p = 0.01). Type 1 endoleak rates differed significantly across devices (Cook Zenith 0.0%, Medtronic Endurant 18.2%, Medtronic Talent 17.6%, p = 0.01). Conclusion Although we identified device-related differences in endoleak rates, there were no significant differences in reintervention rates or mortality outcomes. Favorable outcomes of Cook Zenith and Medtronic Endurant over Medtronic Talent reflect advances in endograft technology and improvements in operator experience over time. Results support selection of endograft by operator preference for ruptured abdominal aortic aneurysm.
Journal of Vascular Surgery | 2017
Prasad Jetty; Don Husereau; Vinay Kansal; Tinghua Zhang; Sudhir Nagpal
Fig 2. Sac regression in patients who had no evidence of any type I endoleak at any point during their follow-up. Statistically significant differences using analysis of variance and Tukey adjustment for multiple comparisons were detected for sac regression by endograft device in the setting of no type I endoleak (Zenith vs Talent endografts at 12 months, P < .012; at 18 months, P 1⁄4 .004; 2 years, P < .0001, P 1⁄4 .0007; 5 years, P 1⁄4 .0004). A further difference was detected between Zenith and Endurant endografts at 5 years, P 1⁄4 .0007. The dashed lines represent endografts placed in <10 patients and thus not included in statistical comparisons. Prasad Jetty, Don Husereau, Vinay Kansal, Tinghua Zhang, Sudhir Nagpal. University of Ottawa, Ottawa, ON, Canada; Ottawa Hospital Research Institute, Methods Centre, Ottawa, ON, Canada
Canadian Medical Association Journal | 2017
Vinay Kansal; Michael Dollin
A 27-year-old woman presented to her family doctor with bilateral ocular pain that waxed and waned, redness and photophobia. The symptoms had progressed over several months and were followed by hoarseness and dyspnea, all of which interfered with her activities of daily living. The patient’s
Journal of Nuclear Cardiology | 2016
Timothy L. Miao; Vinay Kansal; R. Glenn Wells; Iftikhar Ali; Terrence D. Ruddy; Benjamin J.W. Chow
Journal of Cardiovascular Computed Tomography | 2017
Abdulrahman Alqahtani; Kevin E. Boczar; Vinay Kansal; Kwan Chan; Girish Dwivedi; Benjamin J.W. Chow
European Journal of Vascular and Endovascular Surgery | 2018
Vinay Kansal; Sudhir Nagpal; Prasad Jetty