Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Vincent Varlet is active.

Publication


Featured researches published by Vincent Varlet.


Journal of Chromatography B | 2012

Accuracy profile validation of a new method for carbon monoxide measurement in the human blood using headspace-gas chromatography–mass spectrometry (HS-GC–MS)

Vincent Varlet; E. Lagroy De Croutte; Marc Augsburger; Patrice Mangin

The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.


Analytica Chimica Acta | 2013

Innovative method for carbon dioxide determination in human postmortem cardiac gas samples using headspace-gas chromatography–mass spectrometry and stable labeled isotope as internal standard

Vincent Varlet; F. Smith; S. de Froidmont; A. Dominguez; A. Rinaldi; M. Augsburger; Patrice Mangin; Silke Grabherr

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.


Forensic Science International | 2015

When gas analysis assists with postmortem imaging to diagnose causes of death

Vincent Varlet; F. Smith; N. Giuliani; C. Egger; A. Rinaldi; A. Dominguez; C. Chevallier; C. Bruguier; Marc Augsburger; Patrice Mangin; Silke Grabherr

Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.


Journal of Analytical Toxicology | 2015

Hydrogen sulfide measurement by headspace-gas chromatography-mass spectrometry (HS-GC-MS): application to gaseous samples and gas dissolved in muscle.

Vincent Varlet; N. Giuliani; Cristian Palmiere; Géraldine Maujean; Marc Augsburger

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.


Journal of Chromatography B | 2013

Accuracy profile validation of a new analytical method for butane measurement using headspace-gas chromatography-mass spectrometry.

Vincent Varlet; F. Smith; Marc Augsburger

The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.


Journal of Forensic Sciences | 2013

A new approach for the carbon monoxide (CO) exposure diagnosis: measurement of total CO in human blood versus carboxyhemoglobin (HbCO)

Vincent Varlet; Emma Lagroy De Croutte; Marc Augsburger; Patrice Mangin

The aim of the study is to present the application of a headspace–gas chromatography–mass spectrometry (HS‐GC‐MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS‐GC‐MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.


International Journal of Legal Medicine | 2016

Quantification of fatal helium exposure following self-administration

S. Malbranque; D. Mauillon; A. Turcant; C. Rougé-Maillart; Patrice Mangin; Vincent Varlet

Helium is nontoxic at standard conditions, plays no biological role, and is found in trace amounts in human blood. Helium can be dangerous if inhaled to excess, since it is a simple tissue hypoxia and so displaces the oxygen needed for normal respiration. This report presents a fatal case of a middle-aged male victim who died from self-administered helium exposure. For the first time, the quantification of the helium levels in gastric and lung air and in blood samples was achieved using gas chromatography—mass spectrometry after airtight sampling. The results of the toxicological investigation showed that death was caused directly by helium exposure. However, based on the pathomorphological changes detected during the forensic autopsy, we suppose that the fatal outcome was the result of the lack of oxygen after inhalation.


Journal of Analytical Toxicology | 2014

Accuracy Profile Validation of a New Analytical Method for Propane Measurement Using Headspace-Gas Chromatography–Mass Spectrometry

F. Smith; Marc Augsburger; Vincent Varlet

Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C₃DH₇) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D₂O) with Grignard reagent propylmagnesium chloride (C₃H₇MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.


Journal of Chromatography B | 2015

Validation of an analytical method for nitrous oxide (N2O) laughing gas by headspace gas chromatography coupled to mass spectrometry (HS-GC-MS): forensic application to a lethal intoxication.

N. Giuliani; J. Beyer; Marc Augsburger; Vincent Varlet

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.


Journal of Separation Science | 2013

Validation of methane measurement using headspace‐GC–MS and quantification by a stable isotope‐labeled internal standard generated in situ

Vincent Varlet; F. Smith; Marc Augsburger

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Collaboration


Dive into the Vincent Varlet's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Bruguier

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Chevallier

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar

J. Beyer

Kantonsspital St. Gallen

View shared research outputs
Researchain Logo
Decentralizing Knowledge