Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Virve Hagren is active.

Publication


Featured researches published by Virve Hagren.


International Journal of Food Microbiology | 2008

An 8-hour system for Salmonella detection with immunomagnetic separation and homogeneous time-resolved fluorescence PCR

Virve Hagren; Piia von Lode; Anniina Syrjälä; Teemu Korpimäki; Mika Tuomola; Otto Kauko; Jussi Nurmi

We describe a system consisting of rapid sample enrichment and homogeneous end-point PCR analysis that enables the detection of Salmonella in various food matrices in 8 h. Sample preparation starts with 6 h enrichment step in supplemented broth, after which Salmonella cells are collected with immunomagnetic particles. The particles are washed and dispensed to ready-to-use PCR reaction vessels, which contain dried assay-specific reagents and an internal amplification control. PCR is performed with a novel instrument platform utilising the sensitive label technology of time-resolved fluorometry. Qualitative assay results are automatically interpreted and available in 45 min after sample addition. The overall accuracy, sensitivity and specificity of the Magda CA Salmonella system were 99.1%, 98.4% and 100.0%, respectively, based on the evaluation of 107 samples (beef, pork, poultry and ready-to-eat meals) artificially contaminated with sub-lethally injured Salmonella cells.


Analytical Biochemistry | 2008

An automated PCR platform with homogeneous time-resolved fluorescence detection and dry chemistry assay kits

Virve Hagren; Piia von Lode; Anniina Syrjälä; Tero Soukka; Timo Lövgren; Hannu Kojola; Jussi Nurmi

We have developed a novel instrument platform, GenomEra, for small-scale analysis of nucleic acids. The platform combines a rapid thermal cycler, an integrated time-resolved fluorescence measurement unit, and user-friendly software for the analysis of results. Disposable low-cost plastic reaction vessels are designed specifically for the instrument and contain all of the assay-specific reagents in dry form. The appropriate assay protocol is specified on barcodes printed under the vessels and is automatically initiated by the software. Detection is based on the use of sequence-specific probes labeled with intrinsically fluorescent europium or terbium chelates and complementary quencher probes, which enable sensitive, homogeneous closed-tube assays without the risk of carryover contamination. The detection limit of the instrument (background + 3 SD) is approximately 20 pmol/L for both chelates with a dynamic range of nearly four orders of magnitude. The functionality of the platform is demonstrated with a dual-label homogeneous polymerase chain reaction (PCR) assay for the detection of Salmonella using a Magda CA Salmonella assay kit. An internal amplification control is included in each reaction to eliminate false negative results caused by PCR inhibition. Qualitative assay results are automatically interpreted by the software and are available 45 min after sample addition.


Clinical Biochemistry | 2003

One-step quantitative thyrotropin assay for the detection of hypothyroidism in point-of-care conditions.

Piia von Lode; Virve Hagren; Tom Palenius; Timo Lövgren

OBJECTIVES Different screening strategies for early diagnosis of hypothyroidism have been discussed increasingly. We demonstrate the applicability of a miniaturized microparticle assay format for rapid and quantitative determination of increased thyrotropin (TSH) concentrations in serum. DESIGN AND METHODS Porous microparticles were used as solid phase for a noncompetitive, one-step, kinetic immunoassay with varying incubation times and time-resolved fluorescence detection. RESULTS The analytical (mean of zero + 3 SD) and functional (CV <15%) detection limits were 1.5 and 6.0 mIU/L for 2-min, 0.5 and 1.5 mIU/L for 7-min, and 0.2 and 0.5 mIU/L for 15-min assays, respectively. A good correlation was found with the Chiron Diagnostics ACS:180 assay (slopes 0.885-1.051, y-intercepts < +/- 0.20 mIU/L, S(y logical or, bar below x) <or= 0.10 mIU/L, r > 0.98, n = 20). CONCLUSION The kinetic TSH assay provides reproducible and quantitative information on thyroid status within minutes and is applicable for the detection of hypothyroidism in point-of-care (POC) conditions.


Analytical Chemistry | 2004

Generic lanthanide fluoroimmunoassay for the simultaneous screening of 18 sulfonamides using an engineered antibody.

Teemu Korpimäki; Virve Hagren; † and Eeva-Christine Brockmann; Mika Tuomola


Journal of Agricultural and Food Chemistry | 2004

Rapid Time-Resolved Fluoroimmunoassay for the Screening of Narasin and Salinomycin Residues in Poultry and Eggs

Pekka Peippo; Virve Hagren; Timo Lövgren; Mika Tuomola


Analytica Chimica Acta | 2006

Rapid time-resolved fluoroimmunoassay for the screening of monensin residues in eggs

Virve Hagren; Pekka Peippo; Mika Tuomola; Timo Lövgren


Journal of Agricultural and Food Chemistry | 2004

An all-in-one dry chemistry immunoassay for the screening of coccidiostat nicarbazin in poultry eggs and liver

Virve Hagren; Steven R. H. Crooks; Christopher T. Elliott; Timo Lövgren; Mika Tuomola


Analytica Chimica Acta | 2005

Rapid screening method for halofuginone residues in poultry eggs and liver using time-resolved fluorometry combined with the all-in-one dry chemistry assay concept

Virve Hagren; Lisa Connolly; Christopher T. Elliott; Timo Lövgren; Mika Tuomola


Clinical Chemistry | 2007

Fully Automated, Homogeneous Nucleic Acid Detection Technology Based on Dry-Reagent Assay Chemistry and Time-Resolved Fluorometry

Piia von Lode; Anniina Syrjälä; Virve Hagren; Hannu Kojola; Tero Soukka; Timo Lövgren; Jussi Nurmi


Archive | 2008

Method for detection of presence of target polynucleotide in samples

Jussi Nurmi; Anniina Syrjälä; Piia von Lode; Virve Hagren

Collaboration


Dive into the Virve Hagren's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lisa Connolly

Queen's University Belfast

View shared research outputs
Researchain Logo
Decentralizing Knowledge