Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Walter H. Grant is active.

Publication


Featured researches published by Walter H. Grant.


International Journal of Radiation Oncology Biology Physics | 2002

INTENSITY-MODULATED RADIATION THERAPY FOR PEDIATRIC MEDULLOBLASTOMA: EARLY REPORT ON THE REDUCTION OF OTOTOXICITY

Eugene Huang; Bin S. Teh; Douglas Strother; Quillin G. Davis; J. Kam Chiu; Hsin H. Lu; L. Steven Carpenter; Wei Yuan Mai; Murali Chintagumpala; Michael South; Walter H. Grant; E. Brian Butler; Shiao Y. Woo

PURPOSE The combination of cisplatin chemotherapy and radiation therapy for the treatment of medulloblastoma has been shown to cause significant ototoxicity, impairing a childs cognitive function and quality of life. Our purpose is to determine whether the new conformal technique of intensity-modulated radiation therapy (IMRT) can achieve lower rates of hearing loss by decreasing the radiation dose delivered to the cochlea and eighth cranial nerve (auditory apparatus). PATIENTS AND METHODS Twenty-six pediatric patients treated for medulloblastoma were retrospectively divided into two groups that received either conventional radiotherapy (Conventional-RT Group) or IMRT (IMRT Group). One hundred thirteen pure-tone audiograms were evaluated retrospectively, and hearing function was graded on a scale of 0 to 4 according to the Pediatric Oncology Groups toxicity criteria. Statistical analysis comparing the rates of ototoxicity was performed using Fishers exact test with two-tailed analysis. RESULTS When compared to conventional radiotherapy, IMRT delivered 68% of the radiation dose to the auditory apparatus (mean dose: 36.7 vs. 54.2 Gy). Audiometric evaluation showed that mean decibel hearing thresholds of the IMRT Group were lower at every frequency compared to those of the Conventional-RT Group, despite having higher cumulative doses of cisplatin. The overall incidence of ototoxicity was lower in the IMRT Group. Thirteen percent of the IMRT Group had Grade 3 or 4 hearing loss, compared to 64% of the Conventional-RT Group (p < 0.014). CONCLUSION The conformal technique of IMRT delivered much lower doses of radiation to the auditory apparatus, while still delivering full doses to the desired target volume. Our findings suggest that, despite higher doses of cisplatin, and despite radiotherapy before cisplatin therapy, treatment with IMRT can achieve a lower rate of hearing loss.


International Journal of Radiation Oncology Biology Physics | 2001

Intensity-modulated radiation therapy (IMRT) for prostate cancer with the use of a rectal balloon for prostate immobilization: acute toxicity and dose–volume analysis

Bin S. Teh; Wei Yuan Mai; Barry M. Uhl; Mark E. Augspurger; Walter H. Grant; Hsin H. Lu; Shiao Y. Woo; L. Steven Carpenter; J. Kam Chiu; E. Brian Butler

PURPOSE To report acute toxicity and to evaluate the relationship between dose-volume effects and acute toxicity in patients with localized prostate cancer, treated with intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS Acute toxicity (both lower gastrointestinal [GI] and genito-urinary [GU]) in 100 patients treated with IMRT definitively to a prescribed dose of 70 Gy were assessed using RTOG scoring criteria. A rectal balloon was used for prostate immobilization. Mean doses to seminal vesicles, prostate, bladder, and rectum were recorded. Average irradiated bladder and rectal volumes above 65, 70, and 75 Gy were assessed. A relationship between dose volume and clinical toxicity was evaluated. All patients completed the full duration of acute toxicity assessment. RESULTS Mean doses to the prostate and seminal vesicles were 75.8 and 73.9 Gy. This represents a moderate dose escalation. Acute GI toxicity profile was very favorable. Eleven percent and 6% of the patients had grade 1 and 2 GI toxicity, respectively, while 83% had no GI complaint. For GU complaints, 38% and 35% had grade 1 and 2 toxicity, respectively, while 27% had no complaints. There was no grade 3 or higher acute GI or GU toxicity. Mean doses to the bladder were 22.8, 23.4, and 26.1 Gy for grade 0, 1, and 2 GU toxicity, respectively (p = 0.132). There is no statistically significant relationship between acute GU toxicity and the bladder volume receiving > 65 Gy, > 70 Gy, or > 75 Gy. In evaluating acute GI toxicity, there are very few grade 1 and 2 events. No relationship was found between acute rectal toxicity and mean rectal dose or irradiated rectal volumes receiving more than 65, 70, and 75 Gy. CONCLUSION The findings are important with regard to the safety of IMRT, especially in reducing acute GI toxicity. Dose escalation with IMRT using a prostate immobilization technique is feasible. The findings are also important because they contribute to the clinical and dosimetric correlation aspect in the use of IMRT to treat prostate cancer. A larger cohort may be needed to determine if there is a relationship between acute GU toxicity and (a) mean bladder dose and (b) irradiated bladder volume receiving > 65 Gy, > 70 Gy, or > 75 Gy. A larger cohort of patients treated to a higher dose may be needed to show a relationship between dose volume and acute GI toxicity.


International Journal of Radiation Oncology Biology Physics | 2004

Initial experience using intensity-modulated radiotherapy for recurrent nasopharyngeal carcinoma

Tai Xiang Lu; Wei Yuan Mai; Bin S. Teh; Chong Zhao; Fei Han; Yin Huang; Xiao Wu Deng; Li Xia Lu; Shao Min Huang; Zhi Fan Zeng; Cheng Guang Lin; Hsin H. Lu; J. Kam Chiu; L. Steven Carpenter; Walter H. Grant; Shiao Y. Woo; Nan Ji Cui; E. Brian Butler

PURPOSE To report our initial experience on the feasibility, toxicity, and tumor control using intensity-modulated radiotherapy (IMRT) for retreatment of recurrent nasopharyngeal carcinoma (NPC). METHODS AND MATERIALS A total of 49 patients with locoregional recurrent carcinoma in the nasopharynx were treated with IMRT between January 2001 and February 2002 at the Sun Yat-Sen University Cancer Center, Guangzhou, China. The average time to the nasopharyngeal recurrence was 30.2 months after initial conventional RT. The median isocenter dose to the nasopharynx was 70 Gy (range 60.9-78.0) for the initial conventional RT. All patients were restaged at the time of recurrence according to the 1992 Fuzhou, China staging system on NPC. The number of patients with Stage I, II, III and IV disease was 4, 9, 10, and 26, respectively. T1, T2, T3, and T4 disease was found in 4, 9, 11, and 25 patients, respectively. N0, N1, N2, and N3 disease was found in 46, 2, 0, and 1 patient, respectively. Invasion of the nasal cavity, maxillary sinus, ethmoid sinus, sphenoid sinus, and cavernous sinus and erosion of the base of the skull was found in 8, 1, 3, 8, 15, and 20 patients, respectively. The gross tumor volume (GTV) was contoured according to the International Commission on Radiation Units and Measurements (ICRU) Report 62 guidelines. The critical structures were contoured, and the doses to critical structures were constrained according to ICRU 50 guidelines. The GTV in the nasopharynx and positive lymph nodes in the neck received a prescription dose of 68-70 Gy and 60 Gy, respectively. All patients received full-course IMRT. Three patients who had positive lymph nodes were treated with five to six courses of chemotherapy (cisplatin + 5-fluorouracil) after IMRT. RESULTS The treatment plans showed that the percentage of GTV receiving 95% of the prescribed dose (V(95-GTV)) was 98.5%, and the dose encompassing 95% of GTV (D(95-GTV)) was 68.1 Gy in the nasopharynx. The mean dose to the GTV was 71.4 Gy. The average doses of the surrounding critical structures were much lower than the tolerable thresholds. At a median follow-up of 9 months (range 3-13), the locoregional control rate was 100%. Three cases (6.1%) of locoregional residual disease were seen at the completion of IMRT, but had achieved a complete response at follow-up. Three patients developed metastases at a distant site: two in the bone and one in the liver and lung at 13 months follow-up. Acute toxicity (skin, mucosa, and xerostomia) was acceptable according to the Radiation Therapy Oncology Group criteria. Tumor necrosis was seen toward the end of IMRT in 14 patients (28.6%). CONCLUSION The improvement in tumor target coverage and significant sparing of adjacent critical structures allow the feasibility of IMRT as a retreatment option for recurrent NPC after initial conventional RT. This is the first large series using IMRT to reirradiate local recurrent NPC after initial RT failed. The treatment-related toxicity profile was acceptable. The initial tumor response/local control was also very encouraging. In contrast to primary NPC, recurrent NPC reirradiated with high-dose IMRT led to the shedding of tumor necrotic tissue toward the end of RT. More patients and longer term follow-up are warranted to evaluate late toxicity and treatment outcome.


International Journal of Radiation Oncology Biology Physics | 1995

Modulated beam conformal therapy for head and neck tumors

Arthur L. Boyer; Paul Geis; Walter H. Grant; Mark Carol

PURPOSE The goal of modulated-beam conformal therapy is to reduce the dose to healthy tissue and sensitive structures around a uniformly irradiated target volume. Multiple intensity-modulated fields offer improved tissue-sparing dose distributions. New computer-based systems for planning and delivering such treatments may soon be available from different commercial sources that will make the formulation of an intensity-modulated treatment plan and its execution widely available at any treatment facility that has the resources to acquire the necessary equipment. This work reports on a study of the integration of two such systems. METHODS AND MATERIALS Treatment planning was done using a commercially available inverse planning algorithm based on simulated annealing. The plans arbitrarily assumed nine coplanar x-ray beams at nonopposed gantry angles. Intensity modulation was computed for each beam. The modulated field at each gantry angle was broken down into a series of uniform (nonmodulated) subfields, which could be delivered as a sequence to produce the desired dose distribution. Because a large number of subfields was delivered, a multileaf collimator (MLC) was used for field shaping. This allowed rapid and accurate field shaping for treatments made up of several hundred subfields. Computer control of the MLC and linear accelerator allowed delivery of doses less than .01 Gy per subfield. Treatment was delivered on a prototype, computer-controlled accelerator and MLC system. Resulting dose distributions were analyzed using film and an anatomically specific, homogeneous phantom. RESULTS The treatment plans were evaluated using dose-volume histogram analysis. The plans provided acceptably uniform irradiation of the target volume without exceeding dose tolerances for nearby critical structures. The plans were successfully delivered by a prototype dynamic MLC. The time needed to deliver a sequence of subfields at one gantry angle ranged from 0.7 to 2.0 min. Isodoses from film agreed reasonably well with planned isodose distributions. CONCLUSIONS It is feasible to plan and deliver fixed gantry, modulated-beam conformal therapy for head and neck tumors with systems being developed commercially. The planned dose distributions exhibit significant potential for sparing closely spaced normal tissue structures in the head and neck.


International Journal of Radiation Oncology Biology Physics | 2004

Hypofractionated intensity-modulated radiotherapy for primary glioblastoma multiforme

Nathan S. Floyd; Shiao Y. Woo; Bin S. Teh; Charlotte Prado; Wei Yuan Mai; Todd Trask; Philip L. Gildenberg; Paul Y Holoye; Mark E. Augspurger; L. Steven Carpenter; Hsin H. Lu; J. Kam Chiu; Walter H. Grant; E. Brian Butler

PURPOSE A pilot study was designed to evaluate the safety and efficacy of a novel regimen of hypofractionated intensity-modulated radiotherapy (RT) in the adjuvant treatment of primary glioblastoma multiforme (GBM). The rationale of the study was to combine the potential radiobiologic advantage of hypofractionation to GBM with a highly conformal radiotherapeutic technique. The study was designed to measure the acute and chronic morbidity of patients treated with this regimen, response of GBM to the treatment, overall survival, and time to disease progression after therapy completion. METHODS AND MATERIALS Twenty eligible patients were accrued between February 1999 and May 2000 for the study. All patients had Karnofsky performance scores of >/=70. All patients were treated with intensity-modulated RT using the NOMOS Peacock system. A dose of 50 Gy was delivered in 5-Gy daily fractions within 2 weeks to enhancing primary disease, residual tumor, or surgical cavity. Simultaneously, 30 Gy was prescribed in 3-Gy daily fractions to surrounding edema. The time to progression was measured with serial neurologic examinations and MRI or CT scans after RT completion. Acute and late toxicity was graded using Radiation Therapy Oncology Group neurotoxicity scores. RESULTS Of the 20 patients, 18 were evaluated for outcome. The median time to disease progression was 6 months after RT completion. The median overall survival was 7 months after treatment completion. All recurrences were within 2 cm of the operative bed. Neurotoxicity during therapy was minimal, with all patients experiencing Grade 0 or 1 toxicity. Late toxicity included 10 patients with Grade 0, 2 patients with Grade 2, and 3 patients with Grade 4 toxicity, manifesting as brain necrosis requiring surgical reexcision. The survival of the 3 patients with brain necrosis was 23, 20, and 9 months. Mortality in all cases was the result of tumor recurrence, with no mortality resulting from brain necrosis. CONCLUSION This regimen of hypofractionated intensity-modulated RT did not improve the time to disease progression or overall survival compared with historical experience using conventional fractionation. However, the treatment duration was reduced from 6 weeks to 2 weeks, which may be of palliative benefit in certain subsets of patients. This treatment regimen demonstrated a greater incidence of brain necrosis requiring surgical intervention; however, the 3 patients experiencing this toxicity had longer survival times. Future investigation may be useful to determine which fraction size may be optimal for GBM when highly conformal RT is used in the adjuvant setting.


International Journal of Radiation Oncology Biology Physics | 2002

INTENSITY-MODULATED RADIATION THERAPY (IMRT) FOR MENINGIOMA

Nathan W. Uy; Shiao Y. Woo; Bin S. Teh; Wei Yuan Mai; L. Steven Carpenter; Joseph K. Chiu; Hsin H. Lu; Phillip Gildenberg; Todd Trask; Walter H. Grant; E. Brian Butler

PURPOSE To assess the safety and efficacy of intensity-modulated radiation therapy (IMRT) in the treatment of intracranial meningioma. METHODS AND MATERIALS Forty patients with intracranial meningioma (excluding optic nerve sheath meningiomas) were treated using IMRT with the NOMOS Peacock system between 1994 and 1999. Twenty-five patients received IMRT after surgery either as adjuvant therapy for incomplete resection or for recurrence, and 15 patients received definitive IMRT after presumptive diagnosis based on imaging. Thirty-two patients had skull base lesions, and 8 had nonskull base lesions. The prescribed dose ranged from 40 to 56 Gy (median 50.4 Gy) at 1.71 to 2 Gy per fraction, and the volume of the primary target ranged from 1.55 to 324.57 cc (median 20.22 cc). The mean dose to the target ranged from 44 to 60 Gy (median 53 Gy). Follow-up ranged from 6 to 71 months (median 30 months). Acute and chronic toxicity were assessed using Radiation Therapy Oncology Group (RTOG) morbidity criteria and tumor response was assessed by patient report, examination, and imaging. Overall survival, progression-free survival, and local control were calculated using the Kaplan-Meier method. RESULTS Cumulative 5-year local control, progression-free survival, and overall survival were 93%, 88%, and 89%, respectively. Two patients progressed after IMRT, one locally and one distantly. Each was treated with IMRT after multiple recurrences of benign meningioma over many years. Both were found to have malignant meningioma at the time of relapse after IMRT, and it is likely their tumors had already undergone malignant change by the time IMRT was given. Defined normal structures generally received a significantly lower dose than the target. The most common acute central nervous system (CNS) toxicity was mild headache, usually relieved with steroids. One patient experienced RTOG Grade 3 acute CNS toxicity, and 2 experienced Grade 3 or higher late CNS toxicity, with one possible treatment-related death. No toxicity was observed with mean doses to the optic nerve/chiasm up to 47 Gy and maximum doses up to 55 Gy. CONCLUSION IMRT is a promising new technology that is safe and efficacious in the primary and adjuvant treatment of intracranial meningiomas. A history of local aggression may indicate malignant degeneration and predict a poorer outcome. Toxicity data are encouraging, but the potential for serious side effects exists, as demonstrated by one possible treatment-related death. Larger cohort and longer follow-up are needed to better define efficacy and late toxicity of IMRT.


International Journal of Radiation Oncology Biology Physics | 2001

Intensity modulated radiation therapy (IMRT) following prostatectomy: more favorable acute genitourinary toxicity profile compared to primary IMRT for prostate cancer

Bin S. Teh; Wei Yuan Mai; Mark E. Augspurger; Barry M. Uhl; John E. McGary; Lei Dong; Walter H. Grant; E. Brian Butler; Hsin H. Lu; Shiao Y. Woo; L. Steven Carpenter; J. Kam Chiu

PURPOSE To report our initial experience on postprostatectomy IMRT (PPI), addressing acute genitourinary (GU) toxicity in comparison to primary IMRT (PI) for prostate cancer. METHODS AND MATERIALS From April 1998 to December 1999, 40 postprostatectomy patients were treated with intensity modulated radiation therapy (IMRT) to a median prescribed dose of 64 Gy (mean dose of 69 Gy). The Radiation Therapy Oncology Group (RTOG) scoring system was used to assess acute GU toxicity. Target volume and maximum and mean doses were evaluated. The mean doses to the bladder and irradiated bladder volume receiving >65 Gy were assessed. These were compared to those of 125 patients treated with PI to a prescribed dose of 70 Gy (mean dose of 76 Gy). RESULTS The acute GU toxicity profile is more favorable in the PPI group with 82.5% of Grade 0-1 and 17.5% of Grade 2 toxicity compared to 59.2% and 40.8%, respectively, in the PI group (p < 0.001). There was no Grade 3 or higher toxicity in either group. The target volume was larger in the PPI group, while the maximum and mean doses to the target were higher in the PI group. The mean dose delivered to the bladder was higher in the PPI group. The irradiated bladder volume receiving >65 Gy was significantly larger in the PI group (p < 0.001). CONCLUSIONS PPI can be delivered with acceptable ute GU toxicity. The larger PPI target volume may be related to the difficulty in delineating prostatic fossa. Despite a larger target volume and a higher mean dose to the bladder, PPI produced a more favorable acute GU toxicity profile. This may be related to a combination of lower mean and maximum doses and smaller bladder volumes receiving >65 Gy in the PPI group, as well as urethral rather than bladder irradiation. The findings have implications in the evaluation of IMRT treatment plan for prostate cancer, whereby the irradiated bladder volumes above 65 Gy may be more meaningful than the mean dose to the bladder. Longer term toxicity results are awaited.


International Journal of Radiation Oncology Biology Physics | 1996

A comparison of intensity modulated conformal therapy with a conventional external beam stereotactic radiosurgery system for the treatment of single and multiple intracranial lesions.

Shiao Y. Woo; Walter H. Grant; David Bellezza; Robert G. Grossman; Philip L. Gildenberg; L. Steven Carpenter; Mark P. Carol; E. Brian Butler

PURPOSE To compare the stereotactic radiosurgery treatment plans generated by a conventional radiosurgery treatment system with the plan generated by a system using intensity modulated beams. METHODS AND MATERIALS Optimized conformal radiation treatment plans were generated for both single and multiple intracranial lesions using a conventional radiosurgery treatment-planning system computer and the Peacock treatment-planning computer. The Peacock system is a conformal therapy system that uses intensity modulated beams, back projection, and the simulated annealing optimization technique. The dose delivered to critical structures and the target volume were compared by means of dose volume histograms between plans generated by the two different systems. The Radiation Therapy Oncology Group (RTOG) stereotactic radiosurgery criteria were also used to evaluate each plan. RESULTS (a) For a single small target, radiosurgery plans generated by the conventional radiosurgery system and the Peacock system were comparable. (b) For two separate small targets, where nonoverlapping arcs could be used, plans generated by the two systems were also comparable. (c) For a single large (>4 cm) irregular-shaped target, the Peacock system appeared to be able to generate a treatment plan superior to that of the conventional radiosurgery system. CONCLUSIONS A treatment plan generated using intensity modulated beams appears to be superior to a multiple isocenter plan using a conventional radiosurgery system, for the treatment of a large irregular shaped intracranial target.


International Journal of Radiation Oncology Biology Physics | 1996

The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation

Mark Carol; Walter H. Grant; Alan R. Bleier; Alex Kania; Harris Targovnik; E. Brian Butler; Shiao W. Woo

PURPOSE Intensity modulated beam systems have been developed as a means of creating a high-dose region that closely conforms to the prescribed target volume while also providing specific sparing of organs at risk within complex treatment geometries. The slice-by-slice treatment paradigm used by one such system for delivering intensity modulated fields introduces regions of dose nonuniformity where each pair of treatment slices abut. A study was designed to evaluate whether or not the magnitude of the nonuniformity that results from this segmental delivery paradigm is significant relative to the overall dose nonuniformity present in the intensity modulation technique itself. An assessment was also made as to the increase in nonuniformity that would result if errors were made in indexing during treatment delivery. METHODS AND MATERIALS Treatment plans were generated to simulate correctly indexed and incorrectly indexed treatments of 4, 10, and 18 cm diameter targets. Indexing errors of from 0.1 to 2.0 mm were studied. Treatment plans were also generated for targets of the same diameter but of lengths that did not require indexing of the treatment couch. RESULTS The nonuniformity that results from the intensity modulation delivery paradigm is 11-16% for targets where indexing is not required. Correct indexing of the couch adds an additional 1-2% in nonuniformity. However, a couch indexing error of as little as 1 mm can increase the total nonuniformity to as much as 25%. All increases in nonuniformity from indexing are essentially independent of target diameter. CONCLUSIONS The dose nonuniformity introduced by the segmental strip delivery paradigm is small relative to the nonuniformity present in the intensity modulation paradigm itself. A positioning accuracy of better than 0.5 mm appears to be required when implementing segmental intensity modulated treatment plans.


Cancer Journal | 2002

The Use of Rectal Balloon During the Delivery of Intensity Modulated Radiotherapy (imrt) for Prostate Cancer: More Than Just a Prostate Gland Immobilization Device?

Bin S. Teh; John E. McGary; Lei Dong; Wei Yuan Mai; L. Steve Carpenter; Hsin H. Lu; J. Kam Chiu; Shiao Y. Woo; Walter H. Grant; E. Brian Butler

PURPOSEThe purpose of this study was to investigate the role of a rectal balloon for prostate immobilization and rectal toxicity reduction in patients receiving dose-escalated intensity-modulated radiotherapy for prostate cancer. PATIENTS AND METHODSPatients with localized prostate cancer who were undergoing intensity-modulated radiotherapy were treated in a prone position, immobilized with a customized Vac-Lok bag (MED-TEC, Orange City, IA). A rectal balloon with 100 cc of air was used to immobilize the prostate. The prostate displacements were measured using computed tomography (CT)-CT fusion on 10 patients who received radioactive seed implant before intensity-modulated radiotherapy. They were scanned twice weekly during 5 weeks of intensity-modulated radiotherapy, and breathing studies were also performed. Rectal toxicity was evaluated by use of Radiation Therapy Oncology Group scoring in 100 patients. They were treated to a mean dose of 76 Gy over 35 fractions (2.17-Gy fraction size). Dose-volume histogram of the rectum was assessed. A film phantom was constructed to simulate the 4-cm diameter air cavity that was created by the rectal balloon. Kodak XV2 films (Rochester NY) were used to measure and compare dose distribution with and without the air cavity. A fraction of 1.25 Gy was delivered to the phantom at isocenter with 15-MV photons by use of the NOMOS Peacock system and the MIMiC treatment delivery system (Sewickley, PA). RESULTSThe anterior-posterior and lateral prostate displacements were minimal, on the order of measurement uncertainty (∼1 mm). The standard deviation of superior-inferior displacement was 1.78 mm. Breathing studies showed no organ displacement during normal breathing when the rectal balloon was in place. The rectal toxicity profile was very favorable: 83% (83/100) patients had no rectal complaint, and 11% and 6% had grade 1 and 2 toxicity, respectively. Dose-volume histogram analysis revealed that in all of the patients, no more than 25% of the rectum received 70 Gy or greater. As visualized by film dosimetry, the dose at air-tissue interface was approximately 15% lower than that without an air cavity. The dose built up rapidly so that at 1 and 2 mm, the differential was approximately 8% and 5%, respectively. The dosimetric coverage at the depth of the posterior prostate wall was essentially equal, with or without the air cavity. DISCUSSIONThe use of a rectal balloon during intensity-modulated radiotherapy significantly reduces prostate motion. Prostate immobilization thus allows a safer and smaller planning target volume margin. It has also helped spare the anterior rectal wall (by its dosimetric effects) and reduced the rectal volume that received high-dose radiation (by rectal wall distension). All these factors may have further contributed to the decreased rectal toxicity achieved by intensity-modulated radiotherapy, despite dose escalation and higher-than-conventional fraction size.

Collaboration


Dive into the Walter H. Grant's collaboration.

Top Co-Authors

Avatar

E. Brian Butler

Houston Methodist Hospital

View shared research outputs
Top Co-Authors

Avatar

Bin S. Teh

Houston Methodist Hospital

View shared research outputs
Top Co-Authors

Avatar

Shiao Y. Woo

University of Louisville

View shared research outputs
Top Co-Authors

Avatar

John E. McGary

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar

E.B. Butler

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar

Hsin H. Lu

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar

Wei Yuan Mai

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar

J. Kam Chiu

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Arnold C. Paulino

University of Texas MD Anderson Cancer Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge