Wang Heyi
China Academy of Engineering Physics
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Wang Heyi.
Applied Radiation and Isotopes | 2010
Chen Zhilin; Xing Shixiong; Wang Heyi; Chang Ruimin; Wu Guanyin; Zhou Yinhang
The effect of sample vial type and cocktail quantity on tritium measurement in liquid scintillation counting is studied in this paper. With both high and low level tritium samples, glass vials allow higher counting rates than plastic vials do. We also present detailed analysis of the way to obtain the optimal counting condition by dispensing different quantity of cocktail into sample vials. Results indicate that the optimal counting condition has little relationship with tritium concentration in the sample. The main factor which influences the counting is the quantity of cocktail added into samples. Figure of merit is employed to access the results, which increases as the quantity of cocktail increasing. But when the ratio of cocktail and sample reaches 2.0, increase of ratio makes little contribution to the counts, and the disintegrations per minute comes nearly to be a constant.
Chinese Physics C | 2010
Chen Zhilin; Song Guoyang; Mu Long; Wang Heyi; Xing Shixiong; Guo Hongbo; Liao Zhenxing; Chen Ping; Hua Sheng
The optimum condition of three commonly used functions in the Genie 2000 γ spectra analysis software have been studied in the 121–1408 keV energy range. The three functions are applied for fitting the full-energy peak efficiency of the HPGe gamma-ray detector. A detailed procedure to obtain the optimum condition is described. The HPGe detector is calibrated at 11 cm by three radioactive sources of point form (152Eu, 137Cs, 60Co) providing 11 energy peaks. After data processing, results shows that the three functions used in the Genie 2000 gamma spectra analysis software fit best at orders 3–5. Lastly the standard radioactive source 133Ba is chosen to validate the results. Differences between the standard activity of 133Ba and the result obtained from the fitting functions are below 1.5%. Therefore the optimum orders of the three functions used in the Genie 2000 γ spectra analysis software are 3–5 with the 11 energy peaks.
Fusion Engineering and Design | 2008
Sun Ying; Wang Heyi; Sang Ge; Luo Yang-ming; Cao Wei; Liu Yingnu; Xiong Yifu
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2014
Chen Zhilin; Peng Shuming; Meng Dan; He Yuehong; Wang Heyi
Archive | 2015
Zhou Yinxing; Guo Hongbo; Ding Lanlan; Mu Long; Xu Quanmin; Hui Yongqing; Li Qunling; Lin Tao; Deng Yi; Wang Heyi
Archive | 2013
Zhou Yinxing; Yu Weiguo; Xu Quanmin; Lin Qingchuan; Zhang Yuchuan; Ding Lanlan; Guo Hongbo; Zhong Zhijing; Wang Heyi; Zhou Caijie
Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 2008
Wang Heyi
Archive | 2013
Chen Zhilin; Peng Shuming; Meng Dan; Chang Ruimin; Wu Guanyin; Mu Long; He Yuehong; Wang Heyi
Archive | 2013
Chen Zhilin; Peng Shuming; Meng Dan; Chang Ruimin; Wu Guanyin; Mu Long; He Yuehong; Wang Heyi
Archive | 2013
Zhou Yinxing; Yu Weiguo; Xu Quanmin; Lin Qingchuan; Zhang Yuchuan; Ding Lanlan; Guo Hongbo; Zhong Zhijing; Wang Heyi; Zhou Caijie