Optics Express | 2011
Mang Ou-Yang; Wei-De Jeng
In this study, a radial imaging capsule endoscope (RICE) system is designed, which differs from a conventional front imaging capsule endoscope (FICE) system. To observe the wrinkled intima of the intestine, which spreads without folding around the circumference of the capsule when a capsule endoscope with a diameter that slightly exceeds that of the intestine passes through it, the RICE uses a cone mirror, a radial window shell, and a focus optical module that comprise the radial imaging system. This concept was demonstrated in a packaged optical simulator. The RICE optical model also has been established and verified by many simulations and experiments. In minimizing the sagittal and tangential aberrations, the optical module of the RICE has achieved an F-number of 4.2, a viewing angle of 65.08°, and an RMS radius of the 4th to 6th fields of less than 17 um. A comparison of these characteristics with those of the focus optical module that is used in FICE lenses reveals that the spot size is 50% larger for each field, and the modulation transfer function (MTF) is remarkably improved from 7% to 36% at 100 lp/mm on the 5th field of the sagittal plane.
Optical Engineering | 2012
Mang Ou-Yang; Wei-De Jeng; Yin-Yi Wu; Lan-Rong Dung; Hsien-Ming Wu; Ping-Kuo Weng; Ker-Jer Huang; Luan-Jiau Chiu
This study investigates image processing using the radial imaging capsule endoscope (RICE) system. First, an experimental environment is established in which a simulated object has a shape that is similar to a cylinder, such that a triaxial platform can be used to push the RICE into the sample and capture radial images. Then four algorithms (mean absolute error, mean square error, Pearson correlation coefficient, and deformation processing) are used to stitch the images together. The Pearson correlation coefficient method is the most effective algorithm because it yields the highest peak signal-to-noise ratio, higher than 80.69 compared to the original image. Furthermore, a living animal experiment is carried out. Finally, the Pearson correlation coefficient method and vector deformation processing are used to stitch the images that were captured in the living animal experiment. This method is very attractive because unlike the other methods, in which two lenses are required to reconstruct the geometrical image, RICE uses only one lens and one mirror.
Applied Optics | 2015
Yu-Hsiang Tsai; Mao-Hsiu Huang; Wei-De Jeng; Ting-Wei Huang; Kuo-Lung Lo; Mang Ou-Yang
Transparent display is one of the main technologies in next-generation displays, especially for augmented reality applications. An aperture structure is attached on each display pixel to partition them into transparent and black regions. However, diffraction blurs caused by the aperture structure typically degrade the transparent image when the light from a background object passes through finite aperture window. In this paper, the diffraction effect of an active-matrix organic light-emitting diode display (AMOLED) is studied. Several aperture structures have been proposed and implemented. Based on theoretical analysis and simulation, the appropriate aperture structure will effectively reduce the blur. The analysis data are also consistent with the experimental results. Compared with the various transparent aperture structure on AMOLED, diffraction width (zero energy position of diffraction pattern) of the optimize aperture structure can be reduced 63% and 31% in the x and y directions in CASE 3. Associated with a lenticular lens on the aperture structure, the improvement could reach to 77% and 54% of diffraction width in the x and y directions. Modulation transfer function and practical images are provided to evaluate the improvement of image blurs.
Applied Optics | 2014
Wei-De Jeng; Yuan Ouyang; Ting-Wei Huang; Jeng-Ren Duann; Jin-Chern Chiou; Yu-Shun Tang; Mang Ou-Yang
Different levels of visual fatigue in the human eye depend on different color-formation methods and image quality. This paper uses the high-frequency component of the spectral power of accommodative microfluctuations as a major objective indicator for analyzing the effects of visual fatigue based on various displays, such as color-formation displays and 3D displays. Also, a questionnaire is used as a subjective indicator. The results are that 3D videos cause greater visual fatigue than 2D videos (p<0.001), the shutter-type 3D display causes visual fatigue more than the polarized type (p=0.012), the display of the time-sharing method causes greater visual fatigue than the spatial-formation method (p=0.008), and there is no significance between various light source modules of displays (p=0.162). In general, people with normal color discrimination have more visual fatigue than those with good color discrimination (p<0.001). Therefore, this paper uses the high-frequency component of accommodative microfluctuations to evaluate the physiological stress or strain by overexerting the visual system, and can compare the level of visual fatigue between various displays.
Proceedings of SPIE | 2011
Wei-De Jeng; Ou-Yang Mang; Yu-Ta Chen; Ying-Yi Wu
This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.
Optical Engineering | 2013
Mang Ou-Yang; Wei-De Jeng
Abstract. This study concerns the illumination system in a radial imaging capsule endoscope (RICE). Uniformly illuminating the object is difficult because the intensity of the light from the light emitting diodes (LEDs) varies with angular displacement. When light is emitted from the surface of the LED, it first encounters the cone mirror, from which it is reflected, before directly passing through the lenses and complementary metal oxide semiconductor (CMOS) sensor. The light that is strongly reflected from the transparent view window (TVW) propagates again to the cone mirror, to be reflected and to pass through the lenses and CMOS sensor. The above two phenomena cause overblooming on the image plane. Overblooming causes nonuniform illumination on the image plane and consequently reduced image quality. In this work, optical design software was utilized to construct a photometric model for the optimal design of the LED illumination system. Based on the original RICE model, this paper proposes an optimal design to improve the uniformity of the illumination. The illumination uniformity in the RICE is increased from its original value of 0.128 to 0.69, greatly improving light uniformity.
Proceedings of SPIE | 2014
Ting-Wei Huang; Wei-De Jeng; Yuan Ouyang; Y.-H. Tsai; K.-C. Lee; Mang Ou-Yang
The technology of electrowetting display (EWD) is the most important method for the traditional displays that can work more efficiently. When the voltage drives, the aperture ratio of the ink will reach 75% and the transmittance can reach 60%. Furthermore, the EWD technology has the advantages such as high transmittance, high switching speed, color performance, low power consumption, and etc. They make the advances of technology development for the transparent displays. However, due to the diffraction phenomenon resulted from periodic pixel structures, when the users observe the background object through the transparent display, the transmitted image will be blurred. In this paper, we recognized the problems by the simulation and constructed the optical model first. In order to avoid the diffraction, we use micro lens array to prevent the rays interfere on the micro structure, so that it will not produce the destructive and constructive interference, so the diffraction effect can be reduced. The micro lens array avoid the light touches the outer frame of EWD pixels. The simulations are simulate at different distance, and the distance of diffraction width is condensed to 91% with respect to the origin. In the future, this concept can apply in other transmitted images of transparent displays.
Journal of Biomedical Optics | 2016
Mang Ou-Yang; Wei-De Jeng; Chien-Cheng Lai; Hsien-Ming Wu; Jyh-Hung Lin
Abstract. The type of illumination systems and color filters used typically generate varying levels of color difference in capsule endoscopes, which influence medical diagnoses. In order to calibrate the color difference caused by the optical system, this study applied a radial imaging capsule endoscope (RICE) to photograph standard color charts, which were then employed to calculate the color gamut of RICE. Color gamut was also measured using a spectrometer in order to get a high-precision color information, and the results obtained using both methods were compared. Subsequently, color-correction methods, namely polynomial transform and conformal mapping, were used to improve the color difference. Before color calibration, the color difference value caused by the influences of optical systems in RICE was 21.45±1.09. Through the proposed polynomial transformation, the color difference could be reduced effectively to 1.53±0.07. Compared to another proposed conformal mapping, the color difference value was substantially reduced to 1.32±0.11, and the color difference is imperceptible for human eye because it is <1.5. Then, real-time color correction was achieved using this algorithm combined with a field-programmable gate array, and the results of the color correction can be viewed from real-time images.
Proceedings of SPIE | 2013
Mei-Lan Ko; Ting-Wei Huang; Yu-Chen Chen; B.-S. Sone; Ying-Jung Huang; Wei-De Jeng; Yu-Ta Chen; Yao-Fang Hsieh; K.-H. Tao; S.-T. Li; Mang Ou-Yang; Jin-Chern Chiou
Glaucoma was diagnosed or tracked by the intraocular pressure (IOP) generally because it is one of the physiology parameters that are associated with glaucoma. But measurement of IOP is not easy and consistence under different measure conditions. An infrared videopupillography is apparatus to monitor the pupil size in an attempt to bypass the direct IOP measurement. This paper propose an infrared videopupillography to monitoring the pupil size of different light stimulus in dark room. The portable infrared videopupillography contains a camera, a beam splitter, the visible-light LEDs for stimulating the eyes, and the infrared LEDs for lighting the eyes. It is lighter and smaller than the present product. It can modulate for different locations of different eyes, and can be mounted on any eyeglass frame. An analysis program of pupil size can evaluate the pupil diameter by image correlation. In our experiments, the eye diameter curves were not smooth and jagged. It caused by the light spots, lone eyelashes, and blink. In the future, we will improve the analysis program of pupil size and seek the approach to solve the LED light spots. And we hope this infrared videopupillography proposed in this paper can be a measuring platform to explore the relations between the different diseases and pupil response.
ieee sensors | 2012
Yu-Shun Tang; Wei-De Jeng; Ting-Wei Huang; Mang Ou-Yang; Jin-Chern Chiou; Jeng-Ren Duann; Ching-Hsing Luo; Hong-Yi Huang; Yi-Wu Tsai
This article mainly discusses the theoretical derivation and the estimate of the intraocular pressure (IOP) sensor by using inductance. The inductance changes associate with the variation of anterior corneal curvature radius due to the differences of IOP. The value of inductance is transformed by the LC oscillator, and the signal is transmitted by antenna, and finally read by the exterior readout circuit to achieve IOP measuring. The result show that the estimative values of inductance is close to the measured values, and the percentage of inductance variation is about 0.08% per 1 mmHg. Because of the low percentage, it makes much harder to realize readout circuit. In the future, the alteration of structure and material are considered to increase the percentage of varying inductance.