Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Wen-Wen Yue is active.

Publication


Featured researches published by Wen-Wen Yue.


British Journal of Radiology | 2016

Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

Xiao-Long Li; Hui-Xiong Xu; Feng Lu; Wen-Wen Yue; Li-Ping Sun; Xiao-Wan Bo; Le-Hang Guo; Jun-Mei Xu; Bo-Ji Liu; Dan-Dan Li; Shen Qu

OBJECTIVE To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. METHODS The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150-T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. RESULTS In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47-16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510-17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. CONCLUSION Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. ADVANCES IN KNOWLEDGE Based on the comparable efficacy and clinical symptoms between the BRFA and untreated groups, the technique of BRFA can be used as an effective and safe method for the treatment of benign thyroid nodules.


Clinical Hemorheology and Microcirculation | 2016

Parametric imaging with contrast-enhanced ultrasound for differentiating hepatocellular carcinoma from metastatic liver cancer

Wen-Wen Yue; Shuo Wang; Hui-Xiong Xu; Li-Ping Sun; Le-Hang Guo; Xiao-Wan Bo; Xiao-Long Li; Chong-Ke Zhao; Dan Wang; Bo-Ji Liu

AIM To evaluate the diagnostic performance of parametric imaging with contrast-enhanced ultrasound(CEUS) for differentiating hepatocellular carcinoma(HCC) from metastatic liver cancer(MLC). METHODS 30 HCCs (mean diameter, 3.6±1.3 cm; range, 2.1-5.0 cm) and 30 MLCs (mean diameter, 2.8±1.5 cm; range, 1.2-5.0 cm) pathologically diagnosed or confirmed by clinical criteria that underwent CEUS were randomly included. CEUS was carried out using a multifrequency transducer (2-4 MHz) and a bolus injection of 2.4 mL SonoVue. The CEUS clips of the targeted lesion were recorded continuously for 6 minutes. By analyzing CEUS clips, parametric image could be obtained using the SonoLiver® software automatically. Quantitative parameters were compared between HCC and MLC groups. Receiver operating characteristic (ROC) curve analysis was further performed on parameters with significant difference between two groups. RESULTS On parametric imaging, the maximum intensity, rise time, time to peak, mean transit time and washout time for HCC and MLC were 185.6±148.0 vs. 95.2±58.6 (P = 0.003), 25.7±6.3 s vs. 23.8±8.8 s (P = 0.341), 30.7±7.9 s vs. 27.8±10.5 s (P = 0.246), 90.2±45.7 s vs. 89.3±40.3 s (P = 0.805), 63.4±29.5 s vs. 37.2±33.8 s (P = 0.005), respectively. ROC analysis was further performed for washout time and it showed a cut-off point of 43.765 s for the differentiation between HCC and MLC, with the AUC value of 0.780 (95% CI: 0.646-0.914). The corresponding diagnostic specificity, sensitivity and accuracy were 72.0%, 84.6% and 78.4% respectively. CONCLUSIONS Parametric imaging of CEUS can display perfusion effects of HCC and MLC objectively and visually and washout time may serve as a useful parameter on the differential diagnosis between HCC and MLC.


Endocrine | 2017

Radiofrequency ablation vs. microwave ablation for patients with benign thyroid nodules: a propensity score matching study

Wen-Wen Yue; Shu-Rong Wang; Feng Lu; Li-Ping Sun; Le-Hang Guo; Yong-Lin Zhang; Xiao-Long Li; Hui-Xiong Xu

PurposeTo compare the efficacy and the safety of radiofrequency ablation and microwave ablation for treatment of benign thyroid nodules using a propensity score matching study design.MethodsTwo hundred and sixty patients with benign thyroid nodules were studied retrospectively, including 102 patients treated with radiofrequency ablation and 158 treated with microwave ablation. To reduce confounding bias due to retrospective assignment, propensity score matching was performed to balance the preablation data of the two groups. After matching, a total of 102 patient pairs (1:1) were created. The volume reduction ratio, therapeutic success rate, symptom and cosmetic score, and major complication were compared between the two groups at 1, 3, 6, and 12 months after treatment.ResultsBetween the well-matched groups, no significant differences were found in all nodule volume-related end points at 6 months (volume reduction ratio: 79.4 vs. 77.2 %, P = 0.108; symptom score: 2.1 vs. 1.9, P = 0.456; cosmetic score: 2.1 vs. 2.3, P = 0.119; therapeutic success rate: 99 vs. 97 %, P = 0.621) and 12 months (volume reduction ratio: 83.6 vs. 81.6 %, P = 0.144; symptom score: 1.5 vs. 1.5, P = 0.869; cosmetic score: 1.6 vs. 1.7, P = 0.409; therapeutic success rate: 100 vs. 100 %, P > 0.99) after treatment. No major complications occurred in either group (P > 0.99).ConclusionsWith well-matched groups and consistent procedure design, our results demonstrated that the volume reduction ratio, therapeutic success rate, symptom and cosmetic score, and complications related to treatment for the two techniques are equivalent. Radiofrequency ablation and microwave ablation are both effective and safe methods in treating benign thyroid nodules.


Scientific Reports | 2016

Quality of Life and Cost-Effectiveness of Radiofrequency Ablation versus Open Surgery for Benign Thyroid Nodules: a retrospective cohort study

Wen-Wen Yue; Shu-Rong Wang; Feng Lu; Xiao-Long Li; Hui-Xiong Xu; Li-Ping Sun; Le-Hang Guo; Ya-Ping He; Dan Wang; Zhi-Qiang Yin

This study is to compare the health-related quality of life (HRQoL) and cost-effectiveness of radiofrequency ablation (RFA) and open thyroidectomy (OT) for benign thyroid nodules (BTNs) treatment. HRQoL and utility were assessed for 404 BTN patients immediately before treatments (RFA:OT = 137:267) and at 6-month visit. A cost-effectiveness analysis was performed from societal perspective in the China context. Resource use (hospitalization, sick leaves) was collected. We used the net monetary benefit approach and computed cost-effectiveness acceptability curves for RFA and OT. Sensitivity analyses of costs of RFA were performed. At 6-month visit, patients treated with RFA had significantly better HRQoL than patients treated with OT on general health (68.5 versus 66.7, P = 0.029), vitality (71.3 versus 67.5, P < 0.001) and mental health (80.9 versus 79.3, P = 0.038). RFA was more effective than OT in terms of quality-adjusted life-years (QALYs; 0.01QALY/patient) but more expensive (US


Clinical Hemorheology and Microcirculation | 2017

Two-dimensional shear wave elastography of breast lesions: Comparison of two different systems

Wei-Wei Ren; Xiao-Long Li; Ya-Ping He; Dan-Dan Li; Dan Wang; Chong-Ke Zhao; Xiao-Wan Bo; Bo-Ji Liu; Wen-Wen Yue; Hui-Xiong Xu

823/patient). The probability that RFA would be cost effective at a US


Clinical Hemorheology and Microcirculation | 2017

First experience of comparisons between two different shear wave speed imaging systems in differentiating malignant from benign thyroid nodules

Ya-Ping He; Hui-Xiong Xu; Dan Wang; Xiao-Long Li; Wei-Wei Ren; Chong-Ke Zhao; Xiao-Wan Bo; Bo-Ji Liu; Wen-Wen Yue

50,000/QALY threshold was 15.5% in China, and it would be increased to 88.4% when price of the RFA device was lowered by 30%. RFA exhibited a significant improvement of HRQoL relative to OT, but is unlikely to be cost effective at its current price in short time.


Clinical Hemorheology and Microcirculation | 2017

Factors associated with initial incomplete ablation for benign thyroid nodules after radiofrequency ablation: First results of CEUS evaluation

Chong-Ke Zhao; Hui-Xiong Xu; Feng Lu; Li-Ping Sun; Ya-Ping He; Le-Hang Guo; Xiao-Long Li; Xiao-Wan Bo; Wen-Wen Yue

OBJECTIVE To evaluate the diagnostic performance of two different shear wave elastography (SWE) techniques in distinguishing malignant breast lesions from benign ones. MATERIALS AND METHODS From March 2016 to May 2016, a total of 153 breast lesions (mean diameter, 16.8 mm±10.5; range 4.1-90.0 mm) in 153 patients (mean age, 46.4 years±15.1; age range 20-86 years) were separately performed by two different SWE techniques (i.e. T-SWE, Aplio500, Toshiba Medical System, Tochigi, Japan; and S-SWE, the Aixplorer US system, SuperSonic Imagine, Provence, France). The maximum (Emax), mean (Emean) and standard deviation (ESD) of elasticity modulus values in T-SWE and S-SWE were analyzed. All the lesions were confirmed by ultrasound (US)-guided core needle biopsy (n = 26), surgery (n = 122), or both (n = 5), with pathological results as the gold standard. The areas under the receiver operating characteristic curves (AUROCs) were calculated. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) were calculated to assess the diagnostic performance between T-SWE and S-SWE. Operator consistency was also evaluated. RESULTS Among the 153 lesions, 41 (26.8%) were malignant and 112 (73.2%) were benign. Emax (T-SWE: 40.10±37.14 kPa vs. 118.78±34.41 kPa; S-SWE: 41.22±22.54 kPa vs. 134.77±60.51 kPa), Emean (T-SWE: 19.75±16.31 kPa vs. 52.93±25.75 kPa; S-SWE: 20.95±10.98 kPa vs. 55.95±22.42 kPa) and ESD (T-SWE: 9.00±8.55 kPa vs. 38.44±12.30 kPa; S-SWE: 8.17±6.14 kPa vs. 29.34±13.88 kPa) showed statistical differences in distinguishing malignant lesions from benign ones both in T-SWE and S-SWE (all p < 0.05). In T-SWE, the diagnostic performance of ESD was the highest (AUROC = 0.958), followed by Emax (AUROC = 0.909; p = 0.001 in comparison with ESD) and Emean (AUROC = 0.892; p < 0.001 in comparison with ESD), while in S-SWE, the diagnostic performance of Emax was the highest (AUROC = 0.967), followed by ESD (AUROC = 0.962, p > 0.05 in comparison with Emax) and Emean (AUROC = 0.930, p = 0.034 in comparison with Emax). AUROC-max (T-SWE: 0.909 vs. S-SWE 0.967), AUROC-mean (T-SWE: 0.892 vs. S-SWE 0.930) and AUROC-SD (T-SWE: 0.958 vs. S-SWE 0.962) showed no significant difference between T-SWE and S-SWE (all p > 0.05). The intra-class correlation coefficients (ICC) of the intra-operator consistency and inter-operator consistency respectively were 0.961 and 0.898 in T-SWE, while 0.954 and 0.897 in S-SWE. CONCLUSION T-SWE and S-SWE are equivalent for distinguishing the breast lesions. In T-SWE, ESD had the best diagnostic performance, while in S-SWE, Emax had the best diagnostic performance.


Scientific Reports | 2016

A Modified Thyroid Imaging Reporting and Data System (mTI-RADS) For Thyroid Nodules in Coexisting Hashimoto’s Thyroiditis

Hang Zhou; Wen-Wen Yue; Lin-Yao Du; Jun-Mei Xu; Bo-Ji Liu; Xiao-Long Li; Dan Wang; Xian-Li Zhou; Hui-Xiong Xu

OBJECTIVE The purpose of this study was to comparatively evaluate the two different shear wave speed (SWS) imaging systems of Toshiba shear wave elastography (T-SWE) and SuperSonic SWE (S-SWE) in distinguishing malignant from benign thyroid nodules (TNs). MATERIALS AND METHODS 140 patients with 140 focal TNs were enrolled and underwent T-SWE and S-SWE before fine-needle aspiration (FNA) biopsy or surgery. SWE indices of mean, standard deviation and maximum values (E-mean, E-SD and E-max) of elastic modulus in TNs were measured on a color-coded mapping. The receiver operating characteristic (ROC) curve was performed to assess the diagnostic performance. RESULTS Of the 140 nodules, 47 were thyroid carcinomas and 93 were benign. Areas under the receiver operating characteristic curve (AUC) were the highest with E-max among the three SWE parameters both for T-SWE and S-SWE (0.816 and 0.799). The most accurate cut-off values, sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were 26.6 kPa versus 42.9 kPa, 83.0% versus 63.8%, 68.8% versus 88.2%, 72.9% versus 80.0%, 56.5% versus 73.2% and 88.7% versus 82.8% with E-max for T-SWE and S-SWE, respectively. Among these comparisons, the sensitivity in T-SWE was statistically higher than S-SWE (83.0% versus 63.8%, p = 0.022), whereas specificity was statistically lower than S-SWE (68.8% versus 88.2%, p < 0.001). CONCLUSION T-SWE is equal to S-SWE with comparable and promising results for diagnosis of TNs. In clinical using, the selection of E-max should be recommended both for T-SWE and S-SWE.


Scientific Reports | 2017

A Risk Model based on Ultrasound, Ultrasound Elastography, and Histologic Parameters for Predicting Axillary Lymph Node Metastasis in Breast Invasive Ductal Carcinoma

Xiao-Long Li; Hui-Xiong Xu; Dan-Dan Li; Ya-Ping He; Wen-Wen Yue; Jun-Mei Xu; Bo-Ji Liu; Li-Ping Sun; Lin Fang

OBJECTIVE To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). MATERIALS AND METHODS 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). RESULTS The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P < 0.05). The mean VRRs of all BTNs were 23.4%, 54.4% and 81.9% at the 1-, 3- and 6-month follow-up, respectively. All BTNs achieved therapeutic success in this series in that all had VRRs of >50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P < 0.05). CONCLUSION The factors associated with initial ICA after RFA for BTNs were predominantly solid nodules, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with those with ICA.


Scientific Reports | 2017

Association between BRAF V600E Mutation and Ultrasound Features in Papillary Thyroid Carcinoma Patients with and without Hashimoto’s Thyroiditis

Qin Zhang; Bo-Ji Liu; Wei-Wei Ren; Ya-Ping He; Xiao-Long Li; Chong-Ke Zhao; Yi-Feng Zhang; Wen-Wen Yue; Jia-Yi Zheng; Hui-Xiong Xu

To develop a conventional ultrasound (US) modified Thyroid Imaging Reporting and Data System (mTI-RADS) to stratify the malignancy risk of thyroid nodule in coexisting Hashimoto’s thyroiditis (HT). The study included 138 malignant and 292 benign thyroid nodules confirmed by cytological or histopathological results. The risk score (RS) for each significant US feature was estimated by multiplying corresponding regression coefficient and the total score for each nodule was defined as the sum of these individual scores. The mTI-RADS was established according to the total RS and divided into category 3, 4a, 4b, 4c and 5. Marked hypoechogenicity, taller-than-wide shape, poorly-defined margin, microcalcification or macrocalcification and halo sign absence were statistically significant US features in prediction of thyroid malignancy (all p < 0.05). The total RS for each nodule was defined as following: RS = 2.1× (if marked hypoechogenicity) + 1.2× (if taller-than-wide shape) + 1.7× (if no halo sign) + 0.6× (if poorly-defined margin) + 1.2× (if microcalcification or macrocalcification). The malignancy rates in mTI-RADS category 3, 4a, 4b, 4c and 5 nodules were 3.7%, 19.3%, 38.1%, 62.7% and 94.1%, respectively, with significant differences among different categories (P < 0.001). The mTI-RADS category may facilitate subsequent treatment management in HT patients.

Collaboration


Dive into the Wen-Wen Yue's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge