Biomaterials | 2009

A unified mathematical model for the prediction of controlled release from surface and bulk eroding polymer matrices.

Sam N. Rothstein; William J. Federspiel; Steven R. Little

A unified model has been developed to predict release not only from bulk eroding and surface eroding systems but also from matrices that transition from surface eroding to bulk eroding behavior during the course of degradation. This broad applicability is afforded by fundamental diffusion/reaction equations that can describe a wide variety of scenarios including hydration of and mass loss from a hydrolysable polymer matrix. Together, these equations naturally account for spatial distributions of polymer degradation rate. In this model paradigm, the theoretical minimal size required for a matrix to exhibit degradation under surface eroding conditions was calculated for various polymer types and then verified by empirical data from the literature. An additional set of equations accounts for dissolution- and/or degradation-based release, which are dependent upon hydration of the matrix and erosion of the polymer. To test the models accuracy, predictions for agent egress were compared to experimental data from polyanhydride and polyorthoester implants that were postulated to undergo either dissolution-limited or degradation-controlled release. Because these predictions are calculated solely from readily attainable design parameters, it seems likely that this model could be used to guide the design controlled release formulations that produce a broad array of custom release profiles.


Critical Care Medicine | 2011

Respiratory dialysis: reduction in dependence on mechanical ventilation by venovenous extracorporeal CO2 removal.

Bryan S. Jordan; Dara Regn; Corina Necsoiu; William J. Federspiel; Michael J. Morris; Leopoldo C. Cancio

Objectives: Mechanical ventilation is injurious to the lung. Use of lung-protective strategies may complicate patient management, motivating a search for better lung-replacement approaches. We investigated the ability of a novel extracorporeal venovenous CO2 removal device to reduce minute ventilation while maintaining normocarbia. Design: Prospective animal study. Setting: Government laboratory animal intensive care unit. Subjects: Seven sedated swine. Interventions: Tracheostomy, volume-controlled mechanical ventilation, and 72 hrs of round-the-clock intensive care unit care. A 15-F dual-lumen catheter was inserted in the external jugular vein and connected to the Hemolung, an extracorporeal pump-driven venovenous CO2 removal device. Minute ventilation was reduced, and normocarbia (Paco2 35–45 mm Hg) maintained. Heparinization was maintained at an activated clotting time of 150–180 secs. Measurements and Main Results: Minute ventilation (L/min), CO2 removal by Hemolung (mL/min), Hemolung blood flow, O2 consumption (mL/min), CO2 production by the lung (mL/min), Paco2, and plasma-free hemoglobin (g/dL) were measured at baseline (where applicable), 2 hrs after device insertion, and every 6 hrs thereafter. Minute ventilation was reduced from 5.6 L/min at baseline to 2.6 L/min 2 hrs after device insertion and was maintained at 3 L/min until the end of the study. CO2 removal by Hemolung remained steady over 72 hrs, averaging 72 ± 1.2 mL/min at blood flows of 447 ± 5 mL/min. After insertion, O2 consumption did not change; CO2 production by the lung decreased by 50% and stayed at that level (p < .001). As the arterial PCO2 rose or fell, so did CO2 removal by Hemolung. Plasma-free hemoglobin did not change. Conclusions: Venovenous CO2 removal enabled a 50% reduction in minute ventilation while maintaining normocarbia and may be an effective lung-protective adjunct to mechanical ventilation.


Kidney International | 2012

Acute removal of common sepsis mediators does not explain the effects of extracorporeal blood purification in experimental sepsis

Zhi-Yong Peng; Hong-Zhi Wang; Melinda Carter; Morgan V. DiLeo; Jeffery V. Bishop; Feihu Zhou; Thomas Rimmelé; William J. Federspiel; Gilles Clermont; John A. Kellum

The effect of extracorporeal blood purification on clinical outcomes in sepsis is assumed to be related to modulation of plasma cytokine concentrations. To test this hypothesis directly, we treated rats that had a cecal ligation followed by puncture (a standard model of sepsis) with a modest dose of extracorporeal blood purification that did not result in acute changes in a panel of common cytokines associated with inflammation (TNF-α, IL-1β, IL-6, and IL-10). Pre- and immediate post-treatment levels of these cytokines were unchanged compared to the sham therapy of extracorporeal circulation without blood purifying sorbent. The overall survival to 7 days, however, was significantly better in animals that received extracorporeal blood purification compared to those with a sham procedure. This panel of common plasma cytokines along with alanine aminotransferase and creatinine was significantly lower 72 h following extracorporeal blood purification compared to sham-treated rats. Thus, the effects of this procedure on organ function and survival do not appear to be due solely to immediate changes in the usual measured circulating cytokines. These results may have important implications for the design and conduct of future trials in sepsis including defining alternative targets for extracorporeal blood purification and other therapies.


Critical Care | 2012

Bench to bedside review: Extracorporeal carbon dioxide removal, past present and future

Matthew E. Cove; Graeme MacLaren; William J. Federspiel; John A. Kellum

Acute respiratory distress syndrome (ARDS) has a substantial mortality rate and annually affects more than 140,000 people in the USA alone. Standard management includes lung protective ventilation but this impairs carbon dioxide clearance and may lead to right heart dysfunction or increased intracranial pressure. Extracorporeal carbon dioxide removal has the potential to optimize lung protective ventilation by uncoupling oxygenation and carbon dioxide clearance. The aim of this article is to review the carbon dioxide removal strategies that are likely to be widely available in the near future. Relevant published literature was identified using PubMed and Medline searches. Queries were performed by using the search terms ECCOR, AVCO2R, VVCO2R, respiratory dialysis, and by combining carbon dioxide removal and ARDS. The only search limitation imposed was English language. Additional articles were identified from reference lists in the studies that were reviewed. Several novel strategies to achieve carbon dioxide removal were identified, some of which are already commercially available whereas others are in advanced stages of development.


Journal of Biomechanical Engineering-transactions of The Asme | 1998

Effect of intraluminal thrombus thickness and bulge diameter on the oxygen diffusion in abdominal aortic aneurysm.

David A. Vorp; David H.J. Wang; Marshall W. Webster; William J. Federspiel

The intraluminal thrombus (ILT) commonly found within abdominal aortic aneurysm (AAA) may serve as a barrier to oxygen diffusion from the lumen to the inner layers of the aortic wall. The purpose of this work was to address this hypothesis and to assess the effects of AAA bulge diameter (dAAA) and ILT thickness (delta) on the oxygen flow. A hypothetical, three-dimensional, axisymmetric model of AAA containing ILT was created for computational analysis. Commercial software was utilized to estimate the volume flow of O2 per cell, which resulted in zero oxygen tension at the AAA wall. Solutions were generated by holding one of the two parameters fixed while varying the other. The supply of O2 to the AAA wall increases slightly and linearly with dAAA for a fixed delta. This slight increase is due to the enlarged area through which diffusion of O2 may take place. The supply of O2 was found to decrease quickly with increasing delta for a fixed dAAA due to the increased resistance to O2 transport by the ILT layer. The presence of even a thin, 3 mm ILT layer causes a diminished O2 supply (less than 4 x 10(-10) mumol/min/cell). Normally functioning smooth muscle cells require a supply of 21 x 10(-10) mumol/min/cell. Thus, our analysis serves to support our hypothesis that the presence of ILT alters the normal pattern of O2 supply to the AAA wall. This may lead to hypoxic cell dysfunction in the AAA wall, which may further lead to wall weakening and increased potential for rupture.


Asaio Journal | 2004

Evaluation of plasma resistant hollow fiber membranes for artificial lungs.

Heide J. Eash; Heather M. Jones; Brack G. Hattler; William J. Federspiel

Hollow fiber membranes (HFMs) used in artificial lungs (oxygenators) undergo plasma leakage (or wetting) in which blood plasma slowly fills the pores of the fiber wall, plasma leaks into gas pathways, and overall gas exchange decreases. To overcome this problem plasma resistant fibers are being developed that are skinned asymmetric or composite symmetric versions of microporous oxygenator fibers. This report evaluates several candidate plasma resistant HFMs in terms of their gas permeance and plasma resistance as measured in a surfactant wet out test. Five candidate fibers were compared with each other and with a control fiber. CO2 and O2 gas permeance (in ml/s/cm2/cm Hg) in the plasma resistant fibers ranged from 3.15E-04 to 1.71E-03 and 3.40E-04 to 1.08E-03, respectively, compared with 1.62E-02 and 1.77E-02 for the control fiber. Maximum dye bleed through for the plasma resistant fibers in the forced wet out test were significantly less than for the control fiber. CO2 gas permeance of a plasma resistant fiber imposes the greatest constraint upon artificial lung design for sufficient gas exchange. However, our results suggest sufficient plasma resistance can be achieved using special skinned and composite HFMs while maintaining an acceptable CO2 gas permeance for a broad range of artificial lung applications.


Annals of Biomedical Engineering | 1998

A Mathematical Model of Gas Exchange in an Intravenous Membrane Oxygenator

Todd J. Hewitt; Brack G. Hattler; William J. Federspiel

AbstractAcute respiratory distress syndrome (ARDS) is a pulmonary edemic condition which reduces respiratory exchange in 150,000 people per year in the United States. The currently available therapies of mechanical ventilation and extracorporeal membrane oxygenation are associated with high mortality rates, so intravenous oxygenation represents an attractive, alternative support modality. We are developing an intravenous membrane oxygenator (IMO) device intended to provide 50% of basal oxygen and carbon dioxide exchange requirements for ARDS patients. A unique aspect of the IMO is its use of an integral balloon to provide active mixing. This paper describes a mathematical model which was developed to quantify and optimize the gas exchange performance of the IMO. The model focuses on balloon activated mixing, uses a lumped compartment approach, and approximates the blood-side mass transfer coefficients with cross-flow correlations. IMO gas exchange was simulated in water and blood, for a variety of device geometries and balloon pulsation rates. The modeling predicts the following: (1) gas exchange efficiency is reduced by a buildup of oxygen in the fluid near the fibers; (2) the IMO gas exchange rate in blood is normally about twice that in water under comparable conditions; (3) a balloon diameter of about 1.5 cm leads to optimal gas exchange performance; and (4) in vivo positioning can affect gas exchange rates. The numerically predicted gas transfer rates correlate closely with those experimentally measured in vitro for current IMO prototypes.


Journal of Materials Chemistry | 2008

A simple model framework for the prediction of controlled release from bulk eroding polymer matrices

Sam N. Rothstein; William J. Federspiel; Steven R. Little

A broadly applicable model for predicting controlled release could eliminate the need for exploratory, in vitro experiments during the design of new biodegradable matrix-based therapeutics. We have developed a simple mathematical model that can predict the release of many different types of agents from bulk eroding polymer matrices without regression. New methods for deterministically calculating the magnitude of the initial burst and the duration of the lag phase (time before Fickian release) were developed to enable the models broad applicability. To complete the models development, such that predictions can be made from easily measured or commonly known parameters, two correlations were developed by fitting the fundamental equations to published controlled release data. To test the model, predictions were made for several different biodegradable matrix systems. In addition, varying the readily attainable parameters over rational bounds shows that the model predicts a wide range of therapeutically relevant release behaviors.


Molecular Medicine | 2012

Hemoadsorption reprograms inflammation in experimental gram-negative septic peritonitis: insights from in vivo and in silico studies.

Rami A. Namas; Rajaie Namas; Claudio Lagoa; Derek Barclay; Qi Mi; Ruben Zamora; Zhi-Yong Peng; Morgan V. Fedorchak; Isabella E. Valenti; William J. Federspiel; John A. Kellum; Yoram Vodovotz

Improper compartmentalization of the inflammatory response leads to systemic inflammation in sepsis. Hemoadsorption (HA) is an emerging approach to modulate sepsis-induced inflammation. We sought to define the effects of HA on inflammatory compartmentalization in Escherichia coli-induced fibrin peritonitis in rats. Hypothesis: HA both reprograms and recompartmentalizes inflammation in sepsis. Sprague Dawley male rats were subjected to E. coli peritonitis and, after 24 h, were randomized to HA or sham treatment (sepsis alone). Venous blood samples collected at 0, 1, 3 and 6 h (that is, 24–30 h of total experimental sepsis), and peritoneal samples collected at 0 and 6 h, were assayed for 14 cytokines along with NO2−/NO3−. Bacterial counts were assessed in the peritoneal fluid at 0 and 6 h. Plasma tumor necrosis factor (TNF)-α, interleukin (IL)-6, CXCL-1, and CCL2 were significantly reduced in HA versus sham. Principal component analysis (PCA) suggested that inflammation in sham was driven by IL-6 and TNF-α, whereas HA-associated inflammation was driven primarily by TNF-α, CXCL-1, IL-10 and CCL2. Whereas peritoneal bacterial counts, plasma aspartate transaminase levels and peritoneal IL-5, IL-6, IL-18, interferon (IFN)-γ and NO2−/NO3− were significantly lower, both CXCL-1 and CCL2 as well as the peritoneal-to-plasma ratios of TNF-α, CXCL-1 and CCL2 were significantly higher in HA versus sham, suggesting that HA-induced inflammatory recompartmentalization leads to the different inflammatory drivers discerned in part by PCA. In conclusion, this study demonstrates the utility of combined in vivo/in silico methods and suggests that HA exerts differential effects on mediator gradients between local and systemic compartments that ultimately benefit the host.


Asaio Journal | 1999

Ex vivo testing of the intravenous membrane oxygenator.

William J. Federspiel; Joseph F. Golob; Thomas L. Merrill; Laura W. Lund; Jason A. Bultman; Brian J. Frankowski; Mary J. Watach; Kenneth N. Litwak; Brack G. Hattler

Intravenous oxygenation represents a potential respiratory support modality for patients with acute respiratory failure or with acute exacerbations of chronic respiratory conditions. Our group has been developing an intravenous oxygenator, the IMO, which uses a constrained fiber bundle and a rapidly pulsating balloon within the fiber bundle. Balloon pulsation drives blood flow past the fibers at greater relative velocities than would otherwise exist within the host vessel, and gas exchange rates are enhanced. The purpose of this study was twofold: (1) to characterize the gas exchange performance of the current IMO in an extracorporeal mock vena cava vessel under conditions of known fixed vessel geometry and controlled blood flow rates; and (2) to compare the IMO gas exchange performance to that reported for the clinically tested IVOX device within a comparable ex vivo set-up. The ex vivo flow loop consisted of a 1 inch ID tube as a mock vena cava that was perfused directly from an anesthetized calf at blood flow rates ranging from 1 to 4 1/2 L/min. O2 and CO2 exchange rates were measured for balloon pulsation rates, which ranged from 0 to 180 bpm. Balloon pulsation significantly increased gas exchange, by 200-300% at the lowest blood flow rate and 50-100% at the highest blood flow rate. Balloon pulsation eliminated much if not all of the dependence of the gas exchange rate on blood flow rate as seen in passive oxygenators. This suggests that in clinical application the IMO may exhibit less gas transfer variability due to differences in cardiac output Over the entire flow rate range studied, the CO2 and O2 gas exchange rates of the IMO at maximal balloon pulsation varied from approximately 250 to 350 ml/min/m2. At maximum balloon pulsation the IMO exchanged CO2 and O2 at rates from 50-500% greater, depending upon the blood flow rate, than the exchange rates reported for the IVOX device in ex vivo tests.

Collaboration


Dive into the William J. Federspiel's collaboration.

Top Co-Authors

Avatar

Brack G. Hattler

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John A. Kellum

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Laura W. Lund

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Heide J. Eash

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

Mariah S. Hout

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge