Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Wing Yuk Ip is active.

Publication


Featured researches published by Wing Yuk Ip.


Journal of Hand Surgery (European Volume) | 1997

Results of dynamic splintage following extensor tendon repair

Wing Yuk Ip; S. P. Chow

We report a prospective study of dynamic splintage following extensor tendon repair. Eighty-four patients with 101 extensor tendon injuries were studied. Using Dargan’s evaluation system, there were 97% excellent results for the thumb and 93% excellent and good results for the fingers. The average total active motions were 107° for thumbs and 245° for fingers. Over 80% of patients regained good power grip. Patients with associated digital fractures or with ragged lacerations had poorer results. Overall, we found that dynamic splintage was a satisfactory method after extensor repair.


Scandinavian Journal of Infectious Diseases | 2001

A case of disseminated Mycobacterium marinum infection following systemic steroid therapy.

Pak-Leung Ho; Pei Ho; Boris Fung; Wing Yuk Ip; Samson Sai-Yin Wong

We describe the dissemination of Mycobacterium marinum infection from the right middle finger to the whole extremity and two legs, with the involvement of tendons and joints, in a patient who was treated with a steroid when Mycobacterium marinum infection was not suspected. The patient was successfully treated with a combined surgical and medical approach.We describe the dissemination of Mycobacterium marinum infection from the right middle finger to the whole extremity and two legs, with the involvement of tendons and joints, in a patient who was treated with a steroid when Mycobacterium marinum infection was not suspected. The patient was successfully treated with a combined surgical and medical approach.


Journal of orthopaedic surgery | 2012

Mycobacterium marinum infection of the hand and wrist

Jason Pui Yin Cheung; Boris Fung; Wing Yuk Ip; Shew Ping Chow

Purpose. To review records of 166 patients who underwent treatment for Mycobacterium marinum tenosynovitis of the hand and wrist to identify factors associated with functional outcome. Methods. Records of 97 men and 69 women aged 13 to 85 (mean, 50) years who underwent treatment for suspected M marinum tenosynovitis of the hand and wrist were retrospectively reviewed. All underwent open biopsy; synovectomy was performed when florid synovitis was present. Rifampicin and ethambutol were usually prescribed. Clarithromycin, minocycline and/or levofloxacin were used as adjuvants if there was drug intolerance, allergy, or relapse. The duration of antibiotic treatment depended on the clinical recovery. Patients were followed up for one year after completion of drug treatment. Functional outcome was considered excellent for those with >195° total active motion (TAM) and >75% return of motion, good for those with 130° to 195° TAM and 50 to 75% return of motion, fair for those with 65° to 129° TAM and 25 to 49% return of motion, and poor for those with <65° TAM and <25% return of motion. Results. The mean delay in presentation was 4.9 (0.3–120) months. 93 of the patients presented with disabilities (fexion deformity or reduced range of motion), 64 of whom presented one month after injury. 37 (22%) of the patients had received intralesional steroids prior to admission, 30 of whom presented one month after injury. 32 (19%) patients were treated with antibiotics alone, whereas 134 (81%) patients underwent debridement in addition to antibiotic treatment. The mean duration of antibiotic treatment was 7.2 (range, 0–29) months. Of the 156 patients who completed the follow-up, functional outcome was satisfactory in 128 (82%) and unsatisfactory in 28 (17%). Steroid injections and late presentation led to worse functional outcome. Patients with unsatisfactory outcome were more likely to have received intralesional steroid injections (43% [16/37] vs. 10% [12/118], p<0.001, Pearson Chi squared test), have presented >2 months after injury (27% [21/79] vs. 9% [7/77], p=0.004, Pearson Chi squared test), and have undergone synovectomy (23% [28/124]) vs. 0% [0/32], p=0.001, Fishers exact test). Worse functional outcome correlated with late presentation (r=0.218) and the greater number of debridement procedures (r=0.453). Conclusion. Delayed antibiotic treatment of M marinum infections and steroid injections were associated with unsatisfactory outcome. Clinicians must have a high index of suspicion for this condition and avoid inappropriate management such as intralesional steroid injections. Public awareness to this condition should be raised.


Journal of Hand Surgery (European Volume) | 1996

Fixation for Comminuted Phalangeal Fractures A biomechanical study of five methods

William W. Lu; K. Furumachi; Wing Yuk Ip; S. P. Chow

The rigidities of five fixation methods have been studied with a comminuted phalangeal fracture model. Mechanical testing of compression, bending and torsion were performed for each fixation. Lateral plating with six screws seems to provide the most rigid fixation. If such lateral plating is not practicable, the four-Kirschner wire method would be a satisfactory alternative.


Journal of orthopaedic surgery | 2010

Review Article: Mycobacterium Marinum Infection of the Hand and Wrist

Jason Pui Yin Cheung; Boris Fung; Samson Sai-Yin Wong; Wing Yuk Ip

Misdiagnosis and delayed treatment of Mycobacterium marinum infection is common because of its diverse manifestations. This leads to inappropriate use of antimicrobials, extension of the infection from the skin to the tenosynovium, and a poor prognosis (loss of tendons and prolonged immobilisation, secondary to multiple debridements and joint contractures). Clinicians should be aware of this type of infection, especially in subjects at risk (fishermen and aquarium enthusiasts), and those with a history of trauma coupled with exposure to water or marine life. A proactive approach to obtain a biopsy for histopathological and microbiological diagnosis is advised. Anti-mycobacterial treatment should be started promptly. The combined use of rifampicin, ethambutol, and clarithromycin appears to be effective, and debridement is indicated in patients with deep-seated infections.


Journal of Orthopaedic Trauma | 2001

Open reduction and plate fixation of displaced AO type C3 fractures of the Distal radius: Restoration of Articular congruity in Eighteen cases

Alberto Giuseppe Schneeberger; Wing Yuk Ip; Tak Lun Poon; Shew Ping Chow

Objective To determine the ability of open reduction and plate fixation to restore articular congruity in the treatment of fractures of the distal radius with intraarticular comminution and displacement. Design Prospectively followed series. Methods Eighteen consecutive fractures of the distal radius with intraarticular comminution and displacement were treated with open reduction and combined volar and dorsal plate fixation in thirteen, dorsal plate fixation in four, and volar plate fixation in one case. Kirschner wires were added in thirteen fractures and cancellous bone graft was used in four fractures. Articular congruity after a mean follow-up of twenty-three months was assessed using anteroposterior and lateral radiographs. Results Articular congruity without a two millimeter or more intraarticular stepoff was found at follow-up in fifteen of eighteen cases, without a two millimeter or more gap in nine cases and without a two millimeter or more stepoff or gap in only eight cases. One reason for not having obtained articular congruity in some of the fractures was insufficient intraoperative visualization of the joint surface. Three reduced fractures redisplaced. The reason for loss of intraarticular reduction was considered insufficient stabilization of the distal fragments. In two of the three cases, it was thought that insertion of bone graft would have prevented the loss of reduction. Conclusions Articular incongruity after open reduction and plate fixation of comminuted fractures of the distal radius may occur more often than expected. The reduced fracture should be evaluated by intraoperative radiographs. If the reduced joint surface is not entirely visible on the radiographs because of implants or other reasons, oblique radiographs or fluoroscopy should be additionally used. Plate fixation alone does not always provide sufficient stability and cancellous bone graft should be added in cases of metaphyseal bone loss or for stabilization of multiple small articular fragments that cannot be fixed by screws or Kirschner wires.


Hand Surgery | 2012

REVIEW ON MALLET FINGER TREATMENT

Jason Pui Yin Cheung; Boris Fung; Wing Yuk Ip

Mallet finger is a common injury involving either an extensor tendon rupture at its insertion or an avulsion fracture involving the insertion of the terminal extensor tendon. It is usually caused by a forceful blow to the tip of the finger causing sudden flexion or a hyperextension injury. Fracture at the dorsal aspect of the base of the distal phalanx is commonly associated with palmar subluxation of the distal phalanx. Most mallet finger injuries are recommended to be treated with immobilisation of the distal interphalangeal joint in extension by splints. There is no consensus on the type of splint and the duration of use. Most studies have shown comparable results with different splints. Surgical fixation is still indicated in certain conditions such as open injuries, avulsion fracture involving at least one third of the articular surface with or without palmar subluxation of the distal phalanx and also failed splinting treatment.


Journal of Biomedical Materials Research Part A | 2014

Fabrication and characterization of biomimetic multichanneled crosslinked‐urethane‐doped polyester tissue engineered nerve guides

Richard T. Tran; Wai Man Choy; Hung Cao; Ibrahim S. Qattan; Jung-Chih Chiao; Wing Yuk Ip; Kelvin W.K. Yeung; Jian Yang

Biomimetic scaffolds that replicate the native architecture and mechanical properties of target tissues have been recently shown to be a very promising strategy to guide cellular growth and facilitate tissue regeneration. In this study, porous, soft, and elastic crosslinked urethane-doped polyester (CUPE) tissue engineered nerve guides were fabricated with multiple longitudinally oriented channels and an external non-porous sheath to mimic the native endoneurial microtubular and epineurium structure, respectively. The fabrication technique described herein is highly adaptable and allows for fine control over the resulting nerve guide architecture in terms of channel number, channel diameter, porosity, and mechanical properties. Biomimetic multichanneled CUPE guides were fabricated with various channel numbers and displayed an ultimate peak stress of 1.38 ± 0.22 MPa with a corresponding elongation at break of 122.76 ± 42.17%, which were comparable to that of native nerve tissue. The CUPE nerve guides were also evaluated in vivo for the repair of a 1 cm rat sciatic nerve defect. Although histological evaluations revealed collapse of the inner structure from CUPE TENGs, the CUPE nerve guides displayed fiber populations and densities comparable with nerve autograft controls after 8 weeks of implantation. These studies are the first report of a CUPE-based biomimetic multichanneled nerve guide and warrant future studies towards optimization of the channel geometry for use in neural tissue engineering.


Journal of Orthopaedic Surgery and Research | 2008

The versatile reverse flow sural artery neurocutaneous flap: A case series and review of literature

Syed Kamran Ahmed; Boris Fung; Wing Yuk Ip; Margaret Woon Man Fok; Shew Ping Chow

BackgroundReverse flow sural neurocutaneous flap has been utilized more frequently during the past decade to cover vital structures around the foot and ankle area. The potential advantages are the relatively constant blood supply, ease of elevation and preservation of major vascular trunks in the leg. The potential disadvantages remain venous congestion, donor site morbidity and lack of sensation.MethodsThis descriptive case series was conducted at Queen Mary Hospital, Hong Kong, from 1997 to 2003. Ten patients having undergone reverse flow sural neurocutaneous flap were identified through medical records. There were six females (60%) and four males (40%), with an average age of 59.8 years. The defects occurred as a result of trauma in five patients (50%), diabetic ulcers in four (40%) and decubitus ulcer in one (10%) paraplegic patient. The defect site included non weight bearing heel in four (40%), tendo Achilles in two (20%), distal tibia in two (20%), lateral malleolus in one (10%) and medial aspect of the midfoot in one patient (10%). The maximum flap size harvested was 14 × 6 cm. Preoperative doppler evaluation was performed in all patients to identify perforators and modified plaster of paris boot was used in the post operative period. A detailed questionnaire was developed addressing variables of interest.ResultsThere was no flap failure. Venous congestion was encountered in one case. The donor site was relatively unsightly but acceptable to all patients. The loss of sensation in the sural nerve distribution was transient in all patients.ConclusionReverse sural artery flap remains to be the workhorse flap to resurface the soft tissue defects of the foot and ankle. Anastomosis of the sural nerve to the digital plantar nerve can potentially solve the issue of lack of sensation in the flap especially when used for weight bearing heel.


Journal of orthopaedic surgery | 2007

Dynamic treatment for proximal phalangeal fracture of the hand

Rajesh G; Wing Yuk Ip; S. P. Chow; Boris Kk Fung

Purpose. To assess a protected mobilisation programme (dynamic treatment) for proximal phalangeal fracture of the hand, irrespective of the geometry. Methods. Clinical and radiological results of 32 consecutive patients with proximal phalangeal fracture of the hand treated from January 2001 to February 2007 were evaluated. Our supervised rehabilitation programme was strictly followed to gain full range of movement of the proximal interphalangeal joint and to prevent the development of an extension lag contracture. Patients were followed up for a mean period of 15 (range, 13–16) months. Results were evaluated using the Belsky classification. Results. The results were excellent in 72% of the patients, good in 22%, and poor in 6%. Some patients defaulted follow-up, which made long-term assessment difficult. The poor results may have been related to patient non-compliance or default from rehabilitation. Many good results upgraded to excellent following further rehabilitation. Conclusion. Skeletal stability, not rigidity, is necessary for functional movements of the hand. Proximal phalangeal fractures can be effectively treated by closed methods, using the stabilising effect of soft tissues (zancolli complex–metacarpophalangeal retention apparatus) and external devices (metacarpophalangeal block splint), thus enabling bone healing and movement recovery at the same time.

Collaboration


Dive into the Wing Yuk Ip's collaboration.

Top Co-Authors

Avatar

Boris Fung

University of Hong Kong

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S. P. Chow

University of Hong Kong

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rajesh Garg

University of Hong Kong

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Siew Ping Chow

Hong Kong Polytechnic University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge