Thermochimica Acta | 1994
Stefan M. Sarge; E. Gmelin; G.W.H. Höhne; Heiko K. Cammenga; Wolfgang F. Hemminger; Walter Eysel
Abstract The present recommendation of the GEFTA working group “Calibration of Scanning Calorimeters” allows a precise heat and heat flow rate calibration of scanning calorimeters, largely independent of instrumental, sample-related and experimental parameters. Electric energy, electric power, heats of transition and heat capacities of suitable calibration substances are used for calibration. The measuring method, measuring and evaluation procedure, calibration materials, significant influencing factors, sources of error and detailed examples are presented for these calibration methods. Besides specific problems of heat measurement (interpolation of the baseline for the peak area determination) and heat capacity measurement (interpolation between initial and final isotherms, determination of the true heating rate of the sample, thermal lag of the sample), general aspects (thermodynamic fundamentals, difference between heat and heat flow rate calibration factor, weighing procedure) are also discussed.
Thermochimica Acta | 1993
Heiko K. Cammenga; Walter Eysel; E. Gmelin; Wolfgang F. Hemminger; G.W.H. Höhne; Stefan M. Sarge
The recommendation for temperature calibration consists of two parts. Part 1 (see section 2.3) presented a correct method for the calibration of scanning calorimeters (DSC) and of instruments for differential thermal analysis (DTA), irrespective of the instrument type. The present paper recommends calibration substances for the range 120-1350 K. Sections 2 and 3 indicate the documents to be taken into account and define the most important terms used. Section 4 consists of general requirements to be met by the calibration substances, a list of the substances and explanations with respect to their use. Basically, such materials have been selected as calibration substances which define fixed points of the International Temperature Scale of 1990 (ITS-go). Added to these are fixed point materials from the previously valid International Practical Temperature Scale of 1968 (IPTS-68, see References in Table 1). Moreover, two substances are recommended for temperature ranges for which no suitable fixed point material exists, and the respective uncertainty of measurement is stated.
Archive | 2003
G.W.H. Höhne; Wolfgang F. Hemminger; H.-J. Flammersheim
Thermochimica Acta | 1990
G.W.H. Höhne; Heiko K. Cammenga; W. Eysel; E. Gmelin; Wolfgang F. Hemminger
Archive | 1996
G.W.H. Höhne; Wolfgang F. Hemminger; H.-J Flammersheim
Archive | 1989
Wolfgang F. Hemminger; Heiko K. Cammenga
Archive | 1979
Wolfgang F. Hemminger; G.W.H. Höhne
Archive | 2014
Stefan M. Sarge; G.W.H. Höhne; Wolfgang F. Hemminger
Archive | 1989
Wolfgang F. Hemminger; Heiko K. Cammenga
Archive | 1989
Wolfgang F. Hemminger; Heiko K. Cammenga