Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Xue-Hui Chu is active.

Publication


Featured researches published by Xue-Hui Chu.


Biomaterials | 2009

The effect of nanofibrous galactosylated chitosan scaffolds on the formation of rat primary hepatocyte aggregates and the maintenance of liver function.

Zhang-Qi Feng; Xue-Hui Chu; Ningping Huang; Tao Wang; Yi-Chun Wang; Xiaolei Shi; Yitao Ding; Zhongze Gu

Liver tissue engineering requires a perfect extracellular matrix (ECM) for primary hepatocytes culture to maintain high level of liver-specific functions and desirable mechanical stability. The aim of this study was to develop a novel natural nanofibrous scaffold with surface-galactose ligands to enhance the bioactivity and mechanical stability of primary hepatocytes in culture. The nanofibrous scaffold was fabricated by electrospinning a natural material, galactosylated chitosan (GC), into nanofibers with an average diameter of approximately 160 nm. The GC nanofibrous scaffolds displayed slow degradation and suitable mechanical properties as an ECM for hepatocytes according to the evaluation of disintegration and Youngs modulus testing. The results of morphology characterization, double-staining fluorescence assay and function detection showed that hepatocytes cultured on GC nanofibrous scaffold formed stably immobilized 3D flat aggregates and exhibited superior cell bioactivity with higher levels of liver-specific function maintenance in terms of albumin secretion, urea synthesis and cytochrome P-450 enzyme than 3D spheroid aggregates formed on GC films. These spheroid aggregates could be detached easily during culture period from the flat GC films. We suggest such GC-based nanofibrous scaffolds could be useful for various applications such as bioartificial liver-assist devices and tissue engineering for liver regeneration as primary hepatocytes culture substrates.


Biotechnology Letters | 2009

Chitosan nanofiber scaffold enhances hepatocyte adhesion and function.

Xue-Hui Chu; Xiaolei Shi; Zhang-Qi Feng; Zhongze Gu; Yitao Ding

To enhance cell attachment and promote liver functions of hepatocytes cultured in bioreactors, a chitosan nanofiber scaffold was designed and prepared via electrospinning. Effects of the scaffold on hepatocyte adhesion, viability and function were then investigated. Data showed that hepatocytes on chitosan nanofiber scaffold exhibited better viability and tighter cell-substrate contact than cells on regular chitosan film. In addition, urea synthesis, albumin secretion and cytochrome P450 activity of hepatocytes on chitosan nanofiber scaffold were all 1.5 to 2 folds higher than the controls. Glycogen synthesis was also increased as compared with the controls. These results suggested the potential application of this chitosan nanofiber scaffold as a suitable substratum for hepatocyte culturing in bioreactors.


Biomaterials | 2010

Rat hepatocyte aggregate formation on discrete aligned nanofibers of type-I collagen-coated poly(L-lactic acid)

Zhang-Qi Feng; Xue-Hui Chu; Ningping Huang; Michelle K. Leach; Gan Wang; Yi-Chun Wang; Yitao Ding; Zhongze Gu

Primary hepatocytes cultured in three dimensional tissue constructs composed of multicellular aggregates maintain normal differentiated cellular function in vitro while cultured monolayers do not. Here, we report a technique to induce hepatocyte aggregate formation using type-I collagen-coated poly(L-lactic acid) (PLLA) discrete aligned nanofibers (disAFs) by providing limited cell-substrate adhesion strength and restricting cell migration to uniaxial movement. Kinetics of aggregate formation, morphology and biochemical activities of rat hepatocyte aggregates were tested over a 15 day culture period. Evidence was provided that physical cues from disAFs quickly induced the formation of aggregates. After 3 days in culture, 88.3% of free hepatocytes on disAFs were incorporated into aggregates with an average diameter of 61 +/- 18 microm. Hepatocyte aggregates formed on disAFs displayed excellent cell retention, cell activity and stable functional expression in terms of albumin secretion, urea synthesis and phase I and II (CYP1A and UGT) metabolic enzyme activity compared to monolayer culture of hepatocytes on tissue culture plastic (TCP) with type-I collagen as well as on meshes of type-I collagen-coated PLLA random nanofibers (meshRFs). These results suggest that disAFs may be a suitable method to maintain large-scale hepatic cultures with high activity for tissue engineering research and potential therapeutic applications, such as bioartificial liver devices.


Biomaterials | 2009

In vitro evaluation of a multi-layer radial-flow bioreactor based on galactosylated chitosan nanofiber scaffolds

Xue-Hui Chu; Xiaolei Shi; Zhang-Qi Feng; Jinyang Gu; Hai-Yun Xu; Yue Zhang; Zhongze Gu; Yitao Ding

Clinical use of bioartificial livers (BAL) strongly relies on the development of bioreactors. In this study, we developed a multi-layer radial-flow bioreactor based on galactosylated chitosan nanofiber scaffolds and evaluated its efficacy in vitro. The bioreactor contains 65 layers of stacked flat plates, on which the nanofiber scaffolds were electrospinned for hepatocyte immobilization and aggregation. Culture medium containing pig red blood cells (RBCs) was perfused from the center to periphery, so that exchange materials are sufficient to afford enough oxygen. We determined the parameters for hepatocyte-specific function and general metabolism and also measured the oxygen consumption rate (OCR). Microscope and scanned electron microscopy observation showed a tight adhesion between cells and scaffolds. Compared with the control (bioreactors without nanofiber scaffolds), the number of adhered cells in our bioreactor was 1.59-fold; the protein-synthesis capacity of hepatocytes was 1.73-fold and urea was 2.86-fold. Moreover, the OCR of bioreactors with RBCs was about 1.91-fold that of bioreactors without RBCs. The galactosylated chitosan nanofiber scaffolds introduced into our new bioreactor greatly enhanced cell adhesion and function, and the RBCs added into the culture medium were able to afford enough oxygen for hepatocytes. Importantly, our new bioreactor showed an exciting efficiency, and it may afford the short-term support of patients with hepatic failure.


Hepatology Research | 2009

Establishment of a three-dimensional co-culture system by porcine hepatocytes and bone marrow mesenchymal stem cells in vitro

Jinyang Gu; Xiaolei Shi; Yue Zhang; Xue-Hui Chu; Hualian Hang; Yitao Ding

Aim:  The application of porcine hepatocytes in liver support systems has been hampered by the short‐term survival. Co‐cultivation of hepatocytes with non‐parenchymal cells may be beneficial for optimizing cell functions via heterotypic interactions. In this study, we present a new cultivation system of porcine hepatocytes and mesenchymal stem cells (MSCs) in a randomly distributed co‐culture manner.


World Journal of Gastroenterology | 2012

Evaluation of a novel hybrid bioartificial liver based on a multi-layer flat-plate bioreactor.

Xiaolei Shi; Yue Zhang; Xue-Hui Chu; Bing Han; Jinyang Gu; Jiang-Qiang Xiao; Jia-jun Tan; Zhongze Gu; Haozhen Ren; Xianwen Yuan; Yitao Ding

AIM To evaluate the efficacy and safety of a hybrid bioartificial liver (HBAL) system in the treatment of acute liver failure. METHODS Canine models with acute liver failure were introduced with intravenous administration of D-galactosamine. The animals were divided into: the HBAL treatment group (n = 8), in which the canines received a 3-h treatment of HBAL; the bioartificial liver (BAL) treatment group (n = 8), in which the canines received a 3-h treatment of BAL; the non-bioartificial liver (NBAL) treatment group (n = 8), in which the canines received a 3-h treatment of NBAL; the control group (n = 8), in which the canines received no additional treatment. Biochemical parameters and survival time were determined. Levels of xenoantibodies, RNA of porcine endogenous retrovirus (PERV) and reverse transcriptase (RT) activity in the plasma were detected. RESULTS Biochemical parameters were significantly decreased in all treatment groups. The TBIL level in the HBAL group was lower than that in other groups (2.19 ± 0.55 μmol/L vs 24.2 ± 6.45 μmol/L, 12.47 ± 3.62 μmol/L, 3.77 ± 1.83 μmol/L, P < 0.05). The prothrombin time (PT) in the BAL and HBAL groups was significantly shorter than the NBAL and control groups (18.47 ± 4.41 s, 15.5 ± 1.56 s vs 28.67 ± 5.71 s, 21.71 ± 3.4 s, P < 0.05), and the PT in the HBAL group was shortest of all the groups. The albumin in the BAL and HBAL groups significantly increased and a significantly higher level was observed in the HBAL group compared with the BAL group (27.7 ± 1.7 g/L vs 25.24 ± 1.93 g/L). In the HBAL group, the ammonia levels significantly decreased from 54.37 ± 6.86 to 37.75 ± 6.09 after treatment (P < 0.05); there were significant difference in ammonia levels between other the groups (P < 0.05). The levels of antibodies were similar before and after treatment. The PERV RNA and the RT activity in the canine plasma were all negative. CONCLUSION The HBAL showed great efficiency and safety in the treatment of acute liver failure.


European Journal of Medical Research | 2012

Microbiological safety of a novel bio-artificial liver support system based on porcine hepatocytes: a experimental study

Bing Han; Xiaolei Shi; Yue Zhang; Xue-Hui Chu; Jinyang Gu; Jiang-Qiang Xiao; Haozhen Ren; Jia-jun Tan; Zhongze Gu; Yitao Ding

BackgroundOur institute has developed a novel bio-artificial liver (BAL) support system, based on a multi-layer radial-flow bioreactor carrying porcine hepatocytes and mesenchymal stem cells. It has been shown that porcine hepatocytes are capable of carrying infectious porcine endogenous retroviruses (PERVs) into human cells, thus the microbiological safety of any such system must be confirmed before clinical trials can be performed. In this study, we focused on assessing the status of PERV infection in beagles treated with the novel BAL.MethodsFive normal beagles were treated with the novel BAL for 6 hours. The study was conducted for 6 months, during which plasma was collected from the BAL and whole blood from the beagles at regular intervals. DNA and RNA in both the collected peripheral blood mononuclear cells (PBMCs) and plasma samples were extracted for conventional PCR and reverse transcriptase (RT)-PCR with PERV-specific primers and the porcine-specific primer Sus scrofa cytochrome B. Meanwhile, the RT activity and the in vitro infectivity of the plasma were measured.ResultsPositive PERV RNA and RT activity were detected only in the plasma samples taken from the third circuit of the BAL system. All other samples including PBMCs and other plasma samples were negative for PERV RNA, PERV DNA, and RT activity. In the in vitro infection experiment, no infection was found in HEK293 cells treated with plasma.ConclusionsNo infective PERV was detected in the experimental animals, thus the novel BAL had a reliable microbiological safety profile.


Artificial Organs | 2011

Effects of Membrane Molecular Weight Cutoff on Performance of a Novel Bioartificial Liver

Xiaolei Shi; Yue Zhang; Bing Han; Jinyang Gu; Xue-Hui Chu; Jiang-Qiang Xiao; Haozhen Ren; Jiao-jun Tan; Yitao Ding

Immunoisolation using semipermeable membranes has been incorporated into bioartificial liver (BAL) devices to separate cellular components of the recipients immune system from the cells within the BAL device. This study was designed to explore the influence of membrane molecular weight cutoff on performance of the multilayer radial-flow BAL using porcine hepatocytes cocultured with mesenchymal stem cells. In this study, healthy beagles underwent 6-h treatment with a BAL containing membrane with 200 kDa retention rating or 1200 kDa retention rating. Functional markers of BAL performance were monitored before and after treatment, as well as cytotoxic immune response to BAL therapy. The results showed that hepatocyte performance levels such as albumin secretion, urea synthesis, and viability were all significantly higher in 200 kDa retention rating group compared with the 1200 kDa retention rating group after treatment (P <  0.05). Significant levels of canine proteins were detected in BAL medium from the 1200 kDa retention rating group. Fluorescence microscopy further verified that heavy deposition of canine IgG, IgM, and complement (C3) on coculture cells was obtained after BAL treatment in the 1200 kDa retention rating group. However, only trace deposits of canine immunoproteins were observed on coculture cells obtained from BAL in the 200 kDa retention rating group. Small membrane molecular weight cutoff of the BAL could reduce the transfer of xenoreactive antibodies into the BAL medium and improve the performance of the BAL.


Materials Research Express | 2014

In vitro biocompatibility of polypyrrole/PLGA conductive nanofiber scaffold with cultured rat hepatocytes

Xue-Hui Chu; Qian Xu; Zhang-Qi Feng; Jiang-Qiang Xiao; Qiang Li; Xitai Sun; Yang Cao; Yitao Ding

To intruduce conductive biomaterial into liver tissue engineering, a conductive nanofiber scaffold, polypyrrole/poly(lactic-co-glycolic)acid(PLGA), was designed and prepared via electro-spinning and oxidative polymerization. Effects of the scaffold on hepatocyte adhesion, viability and function were then investigated. SEM revealed pseudopodium formation and abundant extracellular matrix on the surface of PLGA membrane and polypyrrole/PLGA membrane. The adhesion rate, cellular activity, urea synthesis and albumin secretion of the hepatocytes cultured on polypyrrole/PLGA group were similar to those on the PLGA group, but were significantly higher than those on the control group. There were no significant differences in concentrations of LDH and TNF-α among three groups. These results suggested the potential application of this conductive nanofiber scaffold as a suitable substratum for hepatocyte culturing in liver tissue engineering.


Artificial Organs | 2012

The Influence of Membrane Molecular Weight Cutoff on a Novel Bioartificial Liver

Yue Zhang; Xiaolei Shi; Bing Han; Jinyang Gu; Xue-Hui Chu; Jiang-Qiang Xiao; Haozhen Ren; Jiao-jun Tan; Yitao Ding

Given the xenogeneic immune reaction relevant to the molecular weight cutoff of the membrane of a bioartificial liver (BAL) system, we investigated the influence of membrane molecular weight cutoff in our BAL system in this study. Acute liver failure in beagles was induced by d-galactosamine administration. Eight beagles were divided into two groups by the membrane molecular weight cutoff of the plasma component separator. Group 1 beagles were treated with BAL containing 200 kDa retention rating membrane. Group 2 beagles were treated with BAL containing 1200 kDa retention rating membrane. Each group underwent two 6-h BAL treatments that were performed on day 1 and day 21. The hemodynamic and hematologic response, humoral immune responses, and cytotoxic immune response to BAL therapy were studied before and after treatments. All beagles remained hemodynamically and hematologically stable during BAL treatments. BAL treatment was associated with a significant decline in levels of complement; however, a longer time of level maintenance was observed in Group 2. Group 2 beagles experienced a significant increase in levels of IgG and IgM after two BAL treatments. Significant levels of canine proteins were detected in BAL medium from Group 2; only trace levels of canine proteins were detected in BAL medium from Group 1. The posttreatment viability of co-culture cells in Group 2 was lower compared with Group 1, and the viability of co-culture cells after treatments was associated with deposition of canine proteins on the cells. Xenogeneic immune response was influenced by membrane molecular weight cutoff in the BAL.

Collaboration


Dive into the Xue-Hui Chu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge