Yang-Fang Li
Max Planck Society
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Yang-Fang Li.
Applied Physics Letters | 2000
Yang-Fang Li; Guozhe Meng; Lide Zhang; F. Phillipp
Ordered semiconductor ZnO nanowire arrays embedded in anodic alumina membranes (AAM) were fabricated by generating alumina templates with nanochannels, electrodepositing Zn in them, and then oxidizing the Zn nanowire arrays. The polycrystalline ZnO nanowires with the diameters ranging from 15 to 90 nm were uniformly assembled into the hexagonally ordered nanochannels of the AAM. Photoluminescence (PL) measurements show a blue PL band in the wavelength range of 450–650 nm caused by the singly ionized oxygen vacancy in ZnO nanowires.
British Journal of Dermatology | 2012
Georg Isbary; Julia Heinlin; Tetsuji Shimizu; Julia L. Zimmermann; G. E. Morfill; Hans-Ulrich Schmidt; Roberto Monetti; Bernd Steffes; Wolfram Bunk; Yang-Fang Li; T. Klaempfl; Sigrid Karrer; Michael Landthaler; Wilhelm Stolz
Background The development of antibiotic resistance by microorganisms is an increasing problem in medicine. In chronic wounds, bacterial colonization is associated with impaired healing. Cold atmospheric plasma is an innovative promising tool to deal with these problems.
Journal of Physics D | 2013
Christian Welz; Sven Becker; Yang-Fang Li; Tetsuji Shimizu; Jin Jeon; Sabina Schwenk-Zieger; H. M. Thomas; Georg Isbary; Gregor E. Morfill; Ulrich Harréus; Julia L. Zimmermann
Thermal plasmas have been commonly used in medical applications such as plasma ablation and blood coagulation. Newer developments show that plasmas can be generated with ion temperatures close to room temperature: these non-thermal or so-called cold atmospheric plasmas (CAPs) therefore open up a wide range of further biomedical applications. Based on the understanding of the bactericidal, virucidal and fungicidal properties of CAPs, information about the effects of CAP on mucosal cells and tissue is still lacking. Therefore this study focuses on the interaction of CAP with healthy head and neck mucosal cells on a molecular level. To analyse this interaction in detail, fresh tissue samples from healthy nasal and pharyngeal mucosa were harvested during surgery, assembled to a three-dimensional tissue culture model (mini organ cultures) and treated with CAP for different treatment times. Effects on the viability, necrosis induction and mutagenic activity were evaluated with the trypan blue exclusion test, Annexin-V/PI staining and alkaline microgel electrophoresis (comet assay). Trypan blue exclusion test revealed that the CAP treatment significantly decreases the cell viability for all tested treatment times (5, 10, 30, 60 and 120s; p< 0.05), but only a treatment time of 120s showed a cytotoxic effect as the viability dropped below 90%. Annexin-V/PI staining revealed a significant increase in necrosis in CAP treated pharyngeal tissue cultures for treatment times of 60 and 120s ( p< 0.05). For nasal tissue this effect was already detected for a 30s treatment ( p< 0.05). Comet assay analysis showed no mutagenic effects after exposure to CAP. (Some figures may appear in colour only in the online journal)
Applied and Environmental Microbiology | 2012
Tobias G. Klämpfl; Georg Isbary; Tetsuji Shimizu; Yang-Fang Li; Julia L. Zimmermann; Wilhelm Stolz; Jürgen Schlegel; Gregor E. Morfill; Hans-Ulrich Schmidt
ABSTRACT Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 log10 CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D 23 ° C values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma.
PLOS ONE | 2013
Stephanie Arndt; Petra Unger; Eva Wacker; Tetsuji Shimizu; Julia Heinlin; Yang-Fang Li; H. M. Thomas; Gregor E. Morfill; Julia L. Zimmermann; Anja-Katrin Bosserhoff; Sigrid Karrer
Cold atmospheric plasma (CAP) has the potential to interact with tissue or cells leading to fast, painless and efficient disinfection and furthermore has positive effects on wound healing and tissue regeneration. For clinical implementation it is necessary to examine how CAP improves wound healing and which molecular changes occur after the CAP treatment. In the present study we used the second generation MicroPlaSter ß® in analogy to the current clinical standard (2 min treatment time) in order to determine molecular changes induced by CAP using in vitro cell culture studies with human fibroblasts and an in vivo mouse skin wound healing model. Our in vitro analysis revealed that the CAP treatment induces the expression of important key genes crucial for the wound healing response like IL-6, IL-8, MCP-1, TGF-ß1, TGF-ß2, and promotes the production of collagen type I and alpha-SMA. Scratch wound healing assays showed improved cell migration, whereas cell proliferation analyzed by XTT method, and the apoptotic machinery analyzed by protein array technology, was not altered by CAP in dermal fibroblasts. An in vivo wound healing model confirmed that the CAP treatment affects above mentioned genes involved in wound healing, tissue injury and repair. Additionally, we observed that the CAP treatment improves wound healing in mice, no relevant side effects were detected. We suggest that improved wound healing might be due to the activation of a specified panel of cytokines and growth factors by CAP. In summary, our in vitro human and in vivo animal data suggest that the 2 min treatment with the MicroPlaSter ß® is an effective technique for activating wound healing relevant molecules in dermal fibroblasts leading to improved wound healing, whereas the mechanisms which contribute to these observed effects have to be further investigated.
PLOS ONE | 2012
Tim Maisch; Tetsuji Shimizu; Yang-Fang Li; Julia Heinlin; Sigrid Karrer; Gregor E. Morfill; Julia L. Zimmermann
In the last twenty years new antibacterial agents approved by the U.S. FDA decreased whereas in parallel the resistance situation of multi-resistant bacteria increased. Thus, community and nosocomial acquired infections of resistant bacteria led to a decrease in the efficacy of standard therapy, prolonging treatment time and increasing healthcare costs. Therefore, the aim of this work was to demonstrate the applicability of cold atmospheric plasma for decolonisation of Gram-positive (Methicillin-resistant Staphylococcus aureus (MRSA), Methicillin-sensitive Staphylococcus aureus) and Gram-negative bacteria (E. coli) using an ex vivo pig skin model. Freshly excised skin samples were taken from six month old female pigs (breed: Pietrain). After application of pure bacteria on the surface of the explants these were treated with cold atmospheric plasma for up to 15 min. Two different plasma devices were evaluated. A decolonisation efficacy of 3 log10 steps was achieved already after 6 min of plasma treatment. Longer plasma treatment times achieved a killing rate of 5 log10 steps independently from the applied bacteria strains. Histological evaluations of untreated and treated skin areas upon cold atmospheric plasma treatment within 24 h showed no morphological changes as well as no significant degree of necrosis or apoptosis determined by the TUNEL-assay indicating that the porcine skin is still vital. This study demonstrates for the first time that cold atmospheric plasma is able to very efficiently kill bacteria applied to an intact skin surface using an ex vivo porcine skin model. The results emphasize the potential of cold atmospheric plasma as a new possible treatment option for decolonisation of human skin from bacteria in patients in the future without harming the surrounding tissue.
PLOS ONE | 2013
Julia Köritzer; Veronika Boxhammer; Andrea Schäfer; Tetsuji Shimizu; Tobias G. Klämpfl; Yang-Fang Li; Christian Welz; Sabina Schwenk-Zieger; G. E. Morfill; Julia L. Zimmermann; Jürgen Schlegel
Glioblastoma (GBM) is the most common and aggressive brain tumor in adults. Despite multimodal treatments including surgery, chemotherapy and radiotherapy the prognosis remains poor and relapse occurs regularly. The alkylating agent temozolomide (TMZ) has been shown to improve the overall survival in patients with malignant gliomas, especially in tumors with methylated promoter of the O6-methylguanine-DNA-methyltransferase (MGMT) gene. However, intrinsic and acquired resistance towards TMZ makes it crucial to find new therapeutic strategies aimed at improving the prognosis of patients suffering from malignant gliomas. Cold atmospheric plasma is a new auspicious candidate in cancer treatment. In the present study we demonstrate the anti-cancer properties of different dosages of cold atmospheric plasma (CAP) both in TMZ-sensitive and TMZ-resistant cells by proliferation assay, immunoblotting, cell cycle analysis, and clonogenicity assay. Importantly, CAP treatment restored the responsiveness of resistant glioma cells towards TMZ therapy. Concomitant treatment with CAP and TMZ led to inhibition of cell growth and cell cycle arrest, thus CAP might be a promising candidate for combination therapy especially for patients suffering from GBMs showing an unfavorable MGMT status and TMZ resistance.
Experimental Dermatology | 2013
Stephanie Arndt; Eva Wacker; Yang-Fang Li; Tetsuji Shimizu; H. M. Thomas; Gregor E. Morfill; Sigrid Karrer; Julia L. Zimmermann; Anja-Katrin Bosserhoff
Over the past few years, the application of cold atmospheric plasma (CAP) in medicine has developed into an innovative field of research of rapidly growing importance. One promising new medical application of CAP is cancer treatment. Different studies revealed that CAP may potentially affect the cell cycle and cause cell apoptosis or necrosis in tumor cells dependent on the CAP device and doses. In this study, we used a novel hand‐held and battery‐operated CAP device utilizing the Surface Micro Discharge (SMD) technology for plasma production in air and consequently analysed dose‐dependent CAP treatment effects on melanoma cells. After 2 min of CAP treatment, we observed irreversible cell inactivation. Phospho‐H2AX immunofluorescence staining and Flow cytometric analysis demonstrated that 2 min of CAP treatment induces DNA damage, promotes induction of Sub‐G1 phase and strongly increases apoptosis. Further, protein array technology revealed induction of pro‐apoptotic events like p53 and Rad17 phosphorylation of Cytochrome c release and activation of Caspase‐3. Interestingly, using lower CAP doses with 1 min of treatment, almost no apoptosis was observed but long‐term inhibition of proliferation. H3K9 immunofluorescence, SA‐ß‐Gal staining and p21 expression revealed that especially these low CAP doses induce senescence in melanoma cells. In summary, we observed differences in induction of apoptosis or senescence of tumor cells in respond to different CAP doses using a new CAP device. The mechanism of senescence with regard to plasma therapy was so far not described previously and is of great importance for therapeutic application of CAP.
Mbio | 2015
Birte Ahlfeld; Yang-Fang Li; Annika Boulaaba; Alfred Binder; Ulrich Schotte; Julia L. Zimmermann; Gregor E. Morfill; Günter Klein
ABSTRACT Human norovirus (NoV) is the most frequent cause of epidemic nonbacterial acute gastroenteritis worldwide. We investigated the impact of nonthermal or cold atmospheric pressure plasma (CAPP) on the inactivation of a clinical human outbreak NoV, GII.4. Three different dilutions of a NoV-positive stool sample were prepared and subsequently treated with CAPP for various lengths of time, up to 15 min. NoV viral loads were quantified by quantitative real-time reverse transcription PCR (RT-qPCR). Increased CAPP treatment time led to increased NoV reduction; samples treated for the longest time had the lowest viral load. From the initial starting quantity of 2.36 × 104 genomic equivalents/ml, sample exposure to CAPP reduced this value by 1.23 log10 and 1.69 log10 genomic equivalents/ml after 10 and 15 min, respectively (P < 0.01). CAPP treatment of surfaces carrying a lower viral load reduced NoV by at least 1 log10 after CAPP exposure for 2 min (P < 0.05) and 1 min (P < 0.05), respectively. Our results suggest that NoV can be inactivated by CAPP treatment. The lack of cell culture assays prevents our ability to estimate infectivity. It is possible that some detectable, intact virus particles were rendered noninfectious. We conclude that CAPP treatment of surfaces may be a useful strategy to reduce the risk of NoV transmission in crowded environments. IMPORTANCE Human gastroenteritis is most frequently caused by noroviruses, which are spread person to person and via surfaces, often in facilities with crowds of people. Disinfection of surfaces that come into contact with infected humans is critical for the prevention of cross-contamination and further transmission of the virus. However, effective disinfection cannot be done easily in mass catering environments or health care facilities. We evaluated the efficacy of cold atmospheric pressure plasma, an innovative airborne disinfection method, on surfaces inoculated with norovirus. We used a clinically relevant strain of norovirus from an outbreak in Germany. Cold plasma was able to inactivate the virus on the tested surfaces, suggesting that this method could be used for continuous disinfection of contaminated surfaces. The use of a clinical strain of norovirus strengthens the reliability of our results as it is a strain relevant to outbreaks in humans. Human gastroenteritis is most frequently caused by noroviruses, which are spread person to person and via surfaces, often in facilities with crowds of people. Disinfection of surfaces that come into contact with infected humans is critical for the prevention of cross-contamination and further transmission of the virus. However, effective disinfection cannot be done easily in mass catering environments or health care facilities. We evaluated the efficacy of cold atmospheric pressure plasma, an innovative airborne disinfection method, on surfaces inoculated with norovirus. We used a clinically relevant strain of norovirus from an outbreak in Germany. Cold plasma was able to inactivate the virus on the tested surfaces, suggesting that this method could be used for continuous disinfection of contaminated surfaces. The use of a clinical strain of norovirus strengthens the reliability of our results as it is a strain relevant to outbreaks in humans.
Applied and Environmental Microbiology | 2012
Tim Maisch; Tetsuji Shimizu; Georg Isbary; Julia Heinlin; Sigrid Karrer; Tobias G. Klämpfl; Yang-Fang Li; Gregor E. Morfill; Julia L. Zimmermann
ABSTRACT Candida albicans is one of the main species able to form a biofilm on almost any surface, causing both skin and superficial mucosal infections. The worldwide increase in antifungal resistance has led to a decrease in the efficacy of standard therapies, prolonging treatment time and increasing health care costs. Therefore, the aim of this work was to demonstrate the applicability of atmospheric plasma at room temperature for inactivating C. albicans growing in biofilms without thermally damaging heat-sensitive materials. This so-called cold atmospheric plasma is produced by applying high voltage to accelerate electrons, which ionize the surrounding air, leading to the production of charged particles, reactive species, and photons. A newly developed plasma device was used, which exhibits a large plasma-generating surface area of 9 by 13 cm (117 cm2). Different time points were selected to achieve an optimum inactivation efficacy range of ≥3 log10 to 5 log10 reduction in CFU per milliliter, and the results were compared with those of 70% ethanol. The results obtained show that contact-free antifungal inactivation of Candida biofilms by cold atmospheric plasma is a promising tool for disinfection of surfaces (and items) in both health care settings and the food industry, where ethanol disinfection should be avoided.