Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yasuo Omi is active.

Publication


Featured researches published by Yasuo Omi.


Investigative Radiology | 2006

Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter : Evaluation with a computer-simulated liver including tumors

Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Taiga Goto; Yasuo Omi; Toshiaki Shimonobo; Duo Liu; Yasuyuki Yamashita; Shinichi Hori

Purpose:The purpose of this study was to investigate how much radiation dose can be reduced without loss of low-contrast detectability with a newly developed adaptive noise reduction filter in hepatic multidetector computed tomography (MDCT) scans by using a computer-simulated liver phantom. Materials and Methods:Simulated CT images, including liver and intrahepatic tumors, were mathematically constructed using a computer workstation to evaluate low-contrast detectability by the observer performance test. Milliampere second for construction of simulated images were 60, 80, 100, and 120 mAs (low dose) and 160 mAs (standard dose) at 120 kVp. Images with 60, 80, 100, and 120 mAs were postprocessed with the adaptive noise reduction filter. A total of 432 images were prepared and receiver operating characteristic (ROC) analysis was performed by 5 radiologists. The detectability of simulated tumor by radiologists was estimated with the area under the ROC curves (Az values). In addition, we visually evaluated CT images of 15 patients with chronic liver damage for graininess of the liver parenchyma, sharpness of the liver contour, conspicuity and marginal sharpness of the liver tumors, and overall image quality. Results:The mean Az value at 0.777 (60 mAs), 0.828 (80 mAs), and 0.844 (100 mAs) without filter was significantly lower than that of 160 mAs without filter (P < 0.001, 60 mAs; P = 0.010, 80 mAs; P = 0.040, 100 mAs). There was no statistical difference between the mean Az value at 80 mAs with and 160 mAs without the adaptive noise reduction filter (P = 0.220) and 100 mAs with and 160 mAs without the adaptive noise reduction filter (P = 0.979). In the visual evaluation of patient livers, there was no statistical difference in the graininess and sharpness of the liver, the conspicuity and marginal sharpness of the tumor, and the overall image quality between standard-dose and filtered low-dose images (Wilcoxon signed rank test, P > 0.05). Conclusion:The radiation dose can be reduced by 50% without loss of nodule detectability by applying the adaptive noise reduction filter to simulated and patient liver images obtained at MDCT.


Archive | 2006

RADIOGRAPHING APPARATUS AND IMAGE PROCESSING PROGRAM

Taiga Goto; Osamu Miyazaki; Koichi Hirokawa; Yasuo Omi


Archive | 2004

Function image display method and device

Yasuo Omi; Osamu Miyazaki; Susumu Yasuda


Archive | 2006

Radiograph and image processing program

Taiga Goto; Osamu Miyazaki; Koichi Hirokawa; Yasuo Omi


Archive | 2005

MULTI-ENERGY X-RAY CT

Koichi Hirokawa; Yasushi Miyazaki; Yasuo Omi; 宮崎 靖; 康夫 尾見; 浩一 廣川


Archive | 2006

Image analyzing device and method

Yasuo Omi; Ryo Takagi; Osamu Miyazaki; Yoshiaki Sugaya


Archive | 2005

Image processing device and method thereof

Yasuo Omi; Osamu Miyazaki; Tsuyoshi Mitake


Archive | 2006

Image analyzing system and method

Yasuo Omi; Ryo Takagi; Osamu Miyazaki; Yoshiaki Sugaya


Archive | 2003

Blood flow dynamic analyzer and its method, and image diagnostic apparatus

Yasuo Omi; Osamu Miyazaki; Masahiko Aoyagi


Archive | 2009

Radiation photography device

Taiga Goto; Osamu Miyazaki; Koichi Hirokawa; Yasuo Omi

Collaboration


Dive into the Yasuo Omi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge