Ygal Twig
Technion – Israel Institute of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ygal Twig.
Review of Scientific Instruments | 2011
Lazar Shtirberg; Ygal Twig; Ekaterina Dikarov; Revital Halevy; Michael Levit; Aharon Blank
A pulsed electron spin resonance (ESR) microimaging system operating at the Q-band frequency range is presented. The system includes a pulsed ESR spectrometer, gradient drivers, and a unique high-sensitivity imaging probe. The pulsed gradient drivers are capable of producing peak currents ranging from ∼9 A for short 150 ns pulses up to more than 94 A for long 1400 ns gradient pulses. Under optimal conditions, the imaging probe provides spin sensitivity of ∼1.6 × 10(8) spins∕√Hz or ∼2.7 × 10(6) spins for 1 h of acquisition. This combination of high gradients and high spin sensitivity enables the acquisition of ESR images with a resolution down to ∼440 nm for a high spin concentration solid sample (∼10(8) spins∕μm(3)) and ∼6.7 μm for a low spin concentration liquid sample (∼6 × 10(5) spins/μm(3)). Potential applications of this system range from the imaging of point defects in crystals and semiconductors to measurements of oxygen concentration in biological samples.
Molecular Physics | 2013
Ygal Twig; Ekaterina Dikarov; Aharon Blank
This paper describes a recently developed new family of miniature surface resonators, used for electron spin resonance spectroscopy and imaging. The first part of the paper provides a detailed description of the operational principles of the surface resonators. It also includes sensitivity analysis for a variety of configurations with inner dimensions ranging from 150 μm down to 2 μm, operating at the Ku, Q, and W frequency bands. Most of the data presented here is based on theoretical predictions; however, some of it is accompanied by experiential results for verification. The second part of the paper describes a new type of double-surface microresonator and its production method. This new configuration enables an efficient coupling of the microwave energy from millimetre-sized microstrip lines to micron structures even at relatively low frequencies. The resonator is analysed both theoretically and experimentally – exhibiting ultra-high spin sensitivity. The conclusion of the two parts of the paper is that micron-scale surface microresonators may achieve spin sensitivity of a few thousands of spins in one second of acquisition time for special samples, such as phosphorous-doped 28Si, at cryogenic temperatures. However, further miniaturization below 1–2 microns does not seem to be beneficial, sensitivity-wise. In addition to their high spin sensitivity, these resonators have a huge conversion factor, reaching in some cases to more than 500–1000 G of microwave magnetic field with input power of 1 W. Some possible applications of these unique capabilities are also described herein.
Applied Physics Letters | 2015
Yaron Artzi; Ygal Twig; Aharon Blank
Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive ex...
Journal of Magnetic Resonance | 2012
Ygal Twig; Ekaterina Dikarov; Aharon Blank
A new probe for acquiring ESR images with microscopic resolution and high spin sensitivity, at a temperature range of ~4.2-300 K, is presented. Details of the probe design, as well as its principle of operation, are provided. The probe incorporates a unique surface loop-gap microresonator. Experimental results demonstrate the systems capability to acquire two - as well as three-dimensional images with a flat test sample of phosphorus-doped silicon. The imaging results also allow verifying the resonators resonance mode - they show its B(1) distribution, which also makes it possible to estimate the number of spins measured in the sample.
Physics Letters A | 2013
Aharon Blank; Ekaterina Dikarov; Roman Shklyar; Ygal Twig
Abstract The detection and imaging with high spatial resolution of a small number of electron spins is an important problem in science and technology. Here we show that, by making use of the smallest electron spin resonance resonator constructed to date ( ∼ 5 μm ) together with a unique cryogenic amplification scheme and submicron imaging capabilities, a sensitivity of less than 1000 electron spins is obtained with spatial resolution of ∼ 500 nm . This is the most sensitive induction-detection experiment carried out to date and it opens the door to many potential applications, one of which is the demonstration of a scalable quantum computation capability.
Review of Scientific Instruments | 2017
Ygal Twig; Anton Sorkin; David Cristea; Akiva Feintuch; Aharon Blank
Electron spin resonance (ESR) is a spectroscopic method used to detect paramagnetic materials, reveal their structure, and also image their position in a sample. ESR makes use of a large static magnetic field to split the energy levels of the electron magnetic moment of the paramagnetic species. A strong microwave magnetic field is applied to excite the spins, and subsequently the ESR system detects their faint microwave signal response. The sensitivity of an ESR system is greatly influenced by the magnitude of the static field and the properties of the microwave resonator used to detect the spin signal. In general terms, the higher the static field (microwave frequency) and the smaller the resonator, the more sensitive the system will be. Previous work aimed at high-sensitivity ESR was focused on the development and testing of very small resonators operating at moderate magnetic fields in the range of ∼0.1-1.2 T (maximum frequency of ∼35 GHz). Here, we describe the design, construction, and testing of recently developed miniature surface loop-gap resonators used in ESR and operating at a much higher frequency of ∼95 GHz (W-band, corresponding to a field of ∼3.4 T). Such resonators can greatly enhance the sensitivity of ESR and also improve the resulting spectral resolution due to the higher static field employed. A detailed description of the resonators design and coupling mechanism, as well as the supporting probe head, is provided. We also discuss the production method of the resonators and probe head and, in the end, provide preliminary experimental results that show the setups high spin sensitivity and compare it to theoretical predictions.
Health Physics | 2015
Helen Woflson; Rizwan Ahmad; Ygal Twig; Benjamin B. Williams; Aharon Blank
AbstractA miniature electron spin resonance (ESR) probehead that includes a static field source and a microwave resonator for in vivo measurement of paramagnetic defects in tooth enamel was developed. These defects are known to be a good marker for quantifying the ionizing radiation dose absorbed in teeth. The probehead has a typical length of just 30 mm and total weight of 220 g. The patient “bites” into the probehead while the measurement procedure is being carried out. The probehead operates in pulsed mode at a frequency of ∼11.2 GHz and supplies a static magnetic field of ∼400 mT. A detailed design of the probehead is provided together with its specifications in terms of measurement volume and signal-to-noise ratio for a typical sample. A specially developed simulation program was used to predict the spatial distribution of the acquired signal under conditions of grossly inhomogeneous static and RF fields. Experimental results with irradiated incisor teeth validated the probehead’s sensitivity, being able to detect signals in tooth irradiated by only 2 Gy. Subject to additional improvements and tests, this type of probehead can potentially have significant clinical applications ranging from mass triage following major nuclear events to routine occupational evaluation of ionizing radiation absorbed over long periods of time.
Analytical Chemistry | 2018
Oleg Zgadzai; Ygal Twig; Helen Wolfson; Rizwan Ahmad; Periannan Kuppusamy; Aharon Blank
Electron spin resonance (ESR) is a powerful analytical technique used for the detection, quantification, and characterization of paramagnetic species ranging from stable organic free radicals and defects in crystals to gaseous oxygen. Traditionally, ESR requires the use of complex instrumentation, including a large magnet and a microwave resonator in which the sample is placed. Here, we present an alternative to the existing approach by inverting the typical measurement topology, namely placing the ESR magnet and resonator inside the sample rather than the other way around. This new development relies on a novel self-contained ESR sensor with a diameter of just 2 mm and length of 3.6 mm, which includes both a small permanent magnet assembly and a tiny (∼1 mm in size) resonator for spin excitation and detection at a frequency of ∼2.6 GHz. The spin sensitivity of the sensor has been measured to be ∼1011 spins/√Hz, and its concentration sensitivity is ∼0.1 mM, using reference samples with a measured volume of just ∼10 nL. Our new approach can be applied for monitoring the partial pressure of oxygen in vitro and in vivo through its paramagnetic interaction with another stable radical, as well as for simple online quantitative inspection of free radicals generated in reaction vessels and electrochemical cells via chemical processes.
Proceedings of SPIE | 2015
Helen Wolfson; Rizwan Ahmad; Ygal Twig; Aharon Blank; Periannan Kuppusamy
Cutaneous (skin) oxygenation is an important prognostic factor for the treatment of chronic wounds, skin cancer, diabetes side effects, and limb amputation. Currently, there are no reliable methods for measuring this parameter. Oximetry, using electron paramagnetic resonance (EPR) spectroscopy, is emerging as a potential tool for clinical oximetry, including cutaneous applications. The problem with EPR oximetry, however, is that the conventional EPR design requires the use of a large magnet that can generate homogeneous field across the sample, making it unattractive for clinical practice. We present a novel approach that makes use of a miniature permanent magnet, combined with a small microwave resonator, to enable the acquisition of EPR signals from paramagnetic species placed on the skin. The instrumentation consists of a hand-held, modular, cylindrical probehead with overall dimensions of 36-mm diameter and 24-mm height, with 150-g weight. The probehead includes a Halbach array of 16 pieces (4×4×8 mm3) of Sm-Co permanent magnet and a loop-gap resonator (2.24 GHz). Preliminary measurements using a Hahn-echo pulse sequence (800 echos in 20 ms) showed a signalto- noise ratio of ~70 compared to ~435 in a homogenous magnet under identical settings. Further work is in progress to improve the performance of the probehead and to optimize the hand-held system for clinical use
Review of Scientific Instruments | 2010
Ygal Twig; Ekaterina Suhovoy; Aharon Blank