Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yi-jian Li is active.

Publication


Featured researches published by Yi-jian Li.


Journal of the American Heart Association | 2015

Causes of Death Following Transcatheter Aortic Valve Replacement: A Systematic Review and Meta‐Analysis

Tian-Yuan Xiong; Yan-Biao Liao; Zhen-Gang Zhao; Yuan-Ning Xu; Xin Wei; Zhi-Liang Zuo; Yi-jian Li; Jia-yu Cao; Hong Tang; Hasan Jilaihawi; Yuan Feng; Mao Chen

Background Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement in patients at high surgical risk. However, there is little published literature on the exact causes of death. Methods and Results The PubMed database was systematically searched for studies reporting causes of death within and after 30 days following TAVR. Twenty-eight studies out of 3934 results retrieved were identified. In the overall analysis, 46.4% and 51.6% of deaths were related to noncardiovascular causes within and after the first 30 days, respectively. Within 30 days of TAVR, infection/sepsis (18.5%), heart failure (14.7%), and multiorgan failure (13.2%) were the top 3 causes of death. Beyond 30 days, infection/sepsis (14.3%), heart failure (14.1%), and sudden death (10.8%) were the most common causes. All possible subgroup analyses were made. No significant differences were seen for proportions of cardiovascular deaths except the comparison between moderate (mean STS score 4 to 8) and high (mean STS score >8) -risk patients after 30 days post-TAVR (56.0% versus 33.5%, P=0.005). Conclusions Cardiovascular and noncardiovascular causes of death are evenly balanced both in the perioperative period and at long-term follow-up after TAVR. Infection/sepsis and heart failure were the most frequent noncardiovascular and cardiovascular causes of death. This study highlights important areas of clinical focus that could further improve outcomes after TAVR.


Eurointervention | 2017

Predictors and outcome of acute kidney injury after transcatheter aortic valve implantation-- a systematic review and meta-analysis.

Yan-biao Liao; Xue-xue Deng; Yang Meng; Zhen-Gang Zhao; Tian-Yuan Xiong; Xiang-jun Meng; Zhi-Liang Zuo; Yi-jian Li; Jia-yu Cao; Yuan-Ning Xu; Mao Chen; Yuan Feng

AIMS The aim of this systematic review and meta-analysis was to investigate the predictors and outcome of acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS There were 35 articles recruiting 13,256 patients included in our study. Hypertension (odds ratio [OR] 1.92, 95% CI: 1.44 to 2.56), diabetes mellitus (OR 1.33, 95% CI: 1.20 to 1.47), peripheral artery disease (OR 1.28, 95% CI: 1.14 to 1.45) and a left ventricular ejection fraction <40% (OR 1.50, 95% CI: 1.19 to 1.88) were identified as significant independent predictors of AKI. In addition to the aforementioned comorbidities, procedure-related/post-TAVI factors such as transapical access (OR 1.68, 95% CI: 1.44 to 1.97), major bleeding (OR 1.82, 95% CI: 1.37 to 2.40) and transfusion (OR 1.30, 95% CI: 1.12 to 1.51) were also associated with a higher risk of AKI. Importantly, the risk of short-term all-cause death increased progressively with the aggravating severity of AKI (OR, 30 days: stage 1: 3.41; stage 2: 4.0; stage 3: 11.02; one year: stage 1: 1.95; stage 2: 2.82; stage 3: 7.34), as determined by a univariate analysis. After eliminating confounders, AKI remained linked to a higher risk for both short-term (30 days: HR 2.12, 95% CI: 1.59 to 2.83) and long-term (≥3 years: HR 1.37, 95% CI: 1.27 to 1.48) all-cause mortality. CONCLUSIONS The reason for the occurrence of AKI was multifactorial, including baseline characteristics, procedure-related and post-TAVI factors. It appeared that even stage 1 AKI exerted detrimental effects on survival within one year, and AKI was also independently linked to mortality beyond three years.


Catheterization and Cardiovascular Interventions | 2016

The relationship between chronic obstructive pulmonary disease and transcatheter aortic valve implantation--A systematic review and meta-analysis.

Yan-biao Liao; Ze‐Xia He; Zhen-Gang Zhao; Xin Wei; Zhi-Liang Zuo; Yi-jian Li; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen

The present study was performed to investigate the relationship between chronic obstructive pulmonary disease (COPD) and transcatheter aortic valve implantation (TAVI). Background: Controversies regarding the relationship between COPD and TAVI have intensified. Methods: A literature review of the PubMed online database was performed, and articles published between January 1, 2002 and March 20, 2015 were analyzed. Random‐effect and fixed‐effect models were used, depending on the between‐study heterogeneity. Results: A total of 28 studies, involving 51,530 patients, were identified in our review. The burden of COPD ranged from 12.5% to 43.4%, and COPD negatively impacted both short‐term and long‐term all‐cause survival (30 days: odds ratio [OR], 1.43, 95% CI, 1.14–1.79; >2 years: hazard ratio [HR], 1.34, 95% CI, 1.12–1.61). COPD was also associated with increased short‐term and mid‐term cardiac‐cause mortality (30 days: OR, 1.29, 95% CI, 1.02–1.64; 1 year: HR: 1.09, 1.02–1.17). Moreover, COPD (OR, 1.97, 95% CI, 1.29–3.0) predicted post‐TAVI acute kidney disease. Importantly, chronic kidney disease (CKD) (HR, 1.2, 95% CI, 1.1–1.32) and the distance of the 6 minute walk test (6MWT) (HR, 1.16, 1.06–1.27) predicted TAVI futility in patients with COPD. Conclusion: COPD is common among patients undergoing TAVI, and COPD impacts both short‐ and long‐term survival. COPD patients, who had a lower BMI, shorter distance of 6MWT and CKD, were at higher risk for TAVI futility.


Catheterization and Cardiovascular Interventions | 2017

Transcatheter aortic valve implantation with the self‐expandable venus A‐Valve and CoreValve devices: Preliminary Experiences in China

Yan-biao Liao; Zhen-Gang Zhao; Xin Wei; Yuan-Ning Xu; Zhi-Liang Zuo; Yi-jian Li; Ming-Xia Zheng; Yuan Feng; Mao Chen

Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A‐Valve and the CoreValve; however, there is no data on their comparative performance.


Cardiology Journal | 2017

Hemodynamic changes after transcatheter aortic valve implantation during sequential follow-ups in patients with bicuspid aortic valve compared with tricuspid aortic valve

Tian-Yuan Xiong; Ming-Xia Zheng; Xin Wei; Yi-jian Li; Yan-biao Liao; Zhen-Gang Zhao; Yuan-Ning Xu; Hong Tang; Yuan Feng; Mao Chen

BACKGROUND To investigate the individual sequential hemodynamic changes after transcatheter aortic valve implantation (TAVI), especially for patients with bicuspid aortic valve (BAV), in comparison with tricuspid aortic valve (TAV). METHODS The study population comprised 85 patients with severe aortic stenosis who underwent TAVI for BAV (n = 49) or TAV (n = 36) with at least two serial echocardiographic follow-ups. Doppler echocardiography was scheduled to be performed at discharge and 1, 3, 6 months and 1 year after the procedure. D peak transvalvular velocities and D mean transvalvular gradients were calculated as the difference at follow-up time points and discharge. Paravalvular leak (PVL) was assessed as another indicator for prosthesis performance. RESULTS Comparisons between patients with BAV and TAV revealed similar gradient performances (1.00 [-2.00, 2.00] vs. 1.00 [-0.25, 5.00] mm Hg, p = 0.57 at 1 month; -0.71 ± 7.52 vs. 1.55 ± 3.97 mm Hg, p = 0.21 at 3 months; 0.96 ± 7.81 vs. 1.53 ± 5.85 mm Hg, p = 0.79 at 6 months; 1.00 [-0.50, 2.25] vs. 3.00 [-0.50, 7.50] mm Hg, p = 0.07 at 1 year). Moreover, the incidence of ≥ mild PVL was not significantly different in patients with BAV and TAV during follow-up (34.88% vs. 19.35%, p = 0.14 at 1 month; 45.83% vs. 27.27%, p = 0.19 at 3 months; 30.00% vs. 23.53%, p = 0.89 at 6 months; 30.00% vs. 17.65%, p = 0.56 at 1 year). CONCLUSIONS TAVI is effective and applicable in BAV anatomy with sustained and acceptable mid- -term prosthesis hemodynamic performance. (Cardiol J 2017; 24, 4: 350-357).


Journal of Thrombosis and Thrombolysis | 2018

Gene polymorphisms in dual antiplatelet therapy and the presence of hypo-attenuated leaflet thickening after transcatheter aortic valve replacement

Tian-Yuan Xiong; Yan-biao Liao; Yuan Feng; Ming-Yue Zhao; Zhen-Gang Zhao; Yi-jian Li; Xiao-jing Liu; Mao Chen

The imaging finding of hypo-attenuated leaflet thickening (HALT) on bioprosthesis after transcatheter aortic valve replacement (TAVR) has been reported. The underlying mechanism is not clear, but leaflet thrombosis is speculated to be the cause. Heterogeneous antiplatelet responses may play a role in the process. This is a prospective, single-center pilot study in patients who received successful TAVR from June 2012 to November 2016. HALT on post-procedural multi-detector computed tomography. We thoroughly genotyped 34 SNPs and 8 SNPs that have been reported for clopidogrel and aspirin resistance. A total of 148 patients were enrolled. There were 15 patients demonstrating signs of HALT. Patients with HALT had a higher rate of atrial fibrillation (AF) pre-TAVR (33.3 vs. 7.5%, P = 0.01). We found that rs4244285 G>A polymorphism of the CYP2C19 gene was associated with the risk of HALT in the overdominant model (OR 4.00 [1.15–13.97], P = 0.02 for GA vs. GG+AA) adjusted by sex and the presence of pre-TAVR AF. Antiplatelet drug resistance is a reasonable possibility involved in HALT. Potential directions were suggested in polymorphisms of the CYP2C19 gene.


Scientific Reports | 2017

Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis

Yan-biao Liao; Yi-jian Li; Li Jun-li; Zhen-Gang Zhao; Xin Wei; Jiay-yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen

The aim of this study was to investigate the incidence, predictors and outcome of prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR). A total of 30 articles incorporating 4,691 patients were identified. The pooled incidences of overall, moderate and severe PPM following TAVR were 33.0%, 25.0% and 11.0% respectively. Medtronic CoreValve (MCV) had lower incidence of overall (32% vs: 40%, P < 0.0001) and moderate (23% vs 32%, P < 0.0001) than Edwards Sapien (ESV). PPM was associated with a younger age, smaller annulus diameter and lower left ventricular ejection fraction in comparison with those patients without PPM. Post-dilation (OR, 0.51, 95% CI, 0.38 to 0.68, p < 0.001) during TAVR would decrease the incidence of PPM. Although PPM was common after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30 day: OR: 1.1, 95% CI, 0.70 to 1.73 and 2 year: OR: 1.01, 95% CI, 0.74 to 1.38) between patients with PPM and those without PPM. In conclusion, despite being common after TAVR, the incidence of PPM was lower than that of surgical aortic valve replacement (SAVR) and decreased with the experience accumulating, and PPM was not seen to impact on short- and mid-term survival, regardless of its magnitude.


International Journal of Cardiology | 2017

Comparison of procedural, clinical and valve performance results of transcatheter aortic valve replacement in patients with bicuspid versus tricuspid aortic stenosis

Yan-biao Liao; Yi-jian Li; Tian-Yuan Xiong; Yuanweixiang Ou; Wenyu Lv; Jialing He; Yi-ming Li; Zhen-Gang Zhao; Xin Wei; Yuan-Ning Xu; Yuan Feng; Mao Chen

BACKGROUND Limited date describing the procedural, clinical and valve performance results of transcatheter aortic valve replacement (TAVR) in patients with bicuspid versus tricuspid aortic stenosis (TAV). METHODS Procedural and clinical results were defined and reported according to VARC-2 criteria. RESULTS Consecutive 87 patients with BAV and 70 patients with TAV were included. Compared to patients with TAV, patients with BAV had similar incidence of second valve implantation (14.9% vs 12.9%, p=0.708), more than mild paravalvular leakage (PVL, 40.2% vs 31.9%, p=0.288), permanent pacemaker implantation (PPM, 24.1% vs 28.6%, p=0.53). Furthermore, the procedural and clinical results of TAVR also did not differ between patients with type 0 and type 1 (second valve implantation: 18.4% vs 11.8%, p=0.71, PVL: 38.8% vs 41.2%, p=0.83, PPM: 18.4% vs 31.6%, p=0.16). The hemodynamic outcomes were similar in patients with BAV and TAV at 1-year (maximum velocity, 2.3 vs 2.2m/s, p=0.307) and 2-year (2.3 vs 2.1m/s, p=0.184) follow-up respectively. Adjusted binary logistic regression analysis found oversizing ratio at 14.45-20.57% is at lower risk for more than mild PVL (OR, 0.069, 95% CI, 0.011-0.428, p=0.004). Moreover, the Kaplan-Meier survival analysis revealed that TAVR in type 0 BAV, type 1 BAV and TAV have comparable risk for midterm mortality (Log rank, p=0.772). CONCLUSION TAVR in whatever type of BAV appeared to be safe and efficacy, and TAVR in BAV was associated with comparable bioprosthetic function during follow up compared to patients with TAV.


Journal of Interventional Cardiology | 2018

Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients

Tian-Yuan Xiong; Yan-biao Liao; Yi-jian Li; Zhen-Gang Zhao; Xin Wei; Jiay-yu Tsauo; Yuan-Ning Xu; Yuan Feng; Mao Chen

BACKGROUND Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Jacc-cardiovascular Interventions | 2018

Supra-Annular Sizing for Transcatheter Aortic Valve Replacement Candidates With Bicuspid Aortic Valve

Tian-Yuan Xiong; Yuan Feng; Yi-jian Li; Zhen-Gang Zhao; Yan-Biao Liao; Yuanweixiang Ou; Xin Wei; Mao Chen

Patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve replacement (TAVR) may experience suboptimal clinical outcomes [(1)][1]. This can be the result of inappropriate prosthesis size selection, anatomic difficulties, or technical factors. Altered anatomies in BAV, such as

Collaboration


Dive into the Yi-jian Li's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge