Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yiyao Ye-Lin is active.

Publication


Featured researches published by Yiyao Ye-Lin.


Medical Engineering & Physics | 2011

Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals

Gema Prats-Boluda; Javier Garcia-Casado; J.L. Martinez-de-Juan; Yiyao Ye-Lin

Although the surface electroenterogram (EEnG) is a weak signal contaminated by strong physiological interference, such as ECG and respiration, abdominal surface recordings of the EEnG could provide a non-invasive method of studying intestinal activity. The goal of this work was to develop a modular, active, low-cost and easy-to-use sensor to obtain a direct estimation of the Laplacian of the EEnG on the abdominal surface in order to enhance the quality of bipolar surface monitoring of intestinal activity. The sensor is made up of a set of 3 concentric dry Ag/AgCl ring electrodes and a battery-powered signal-conditioning circuit. Each section is etched on a different printed circuit board (PCB) and the sections are joined to each other by surface mount technology connectors. This means the sensing electrodes can be treated independently for purposes of maintenance and replacement and the signal conditioning circuit can be re-used. A total of ten recording sessions were carried out on humans. The results show that the surface recordings of the EEnG obtained by the active sensor present significantly less ECG and respiration interference than those obtained by bipolar recordings. In addition, bioelectrical sources whose frequency fitted with the slow wave component of the EEnG (SW) were identified by parametric spectral analysis in the surface signals picked up by the active sensors.


Measurement Science and Technology | 2012

Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings

Gema Prats-Boluda; Yiyao Ye-Lin; Eduardo Garcia-Breijo; Javier Ibáñez; Javier Garcia-Casado

Bioelectrical surface recordings are usually performed by unipolar or bipolar disc electrodes even though they entail the serious disadvantage of having poor spatial resolution. Concentric ring electrodes give improved spatial resolution, although this type of electrode has so far only been implemented in rigid substrates and as they are not adapted to the curvature of the recording surface may provide discomfort to the patient. Moreover, the signals recorded by these electrodes are usually lower in amplitude than conventional disc electrodes. The aim of this work was thus to develop and test a new modular active sensor made up of concentric ring electrodes printed on a flexible substrate by thick-film technology together with a reusable battery-powered signal-conditioning circuit. Simultaneous ECG recording with both flexible and rigid concentric ring electrodes was carried out on ten healthy volunteers at rest and in motion. The results show that flexible concentric ring electrodes not only present lower skin–electrode contact impedance and lower baseline wander than rigid electrodes but are also less sensitive to interference and motion artefacts. We believe these electrodes, which allow bioelectric signals to be acquired non-invasively with better spatial resolution than conventional disc electrodes, to be a step forward in the development of new monitoring systems based on Laplacian potential recordings.


Medical Engineering & Physics | 2013

Comparison of non-invasive electrohysterographic recording techniques for monitoring uterine dynamics

José Alberola-Rubio; Gema Prats-Boluda; Yiyao Ye-Lin; Valero J; Alfredo Perales; Javier Garcia-Casado

Non-invasive recording of uterine myoelectric activity (electrohysterogram, EHG) could provide an alternative to monitoring uterine dynamics by systems based on tocodynamometers (TOCO). Laplacian recording of bioelectric signals has been shown to give better spatial resolution and less interference than mono- and bipolar surface recordings. The aim of this work was to study the signal quality obtained from monopolar, bipolar and Laplacian techniques in EHG recordings, as well as to assess their ability to detect uterine contractions. Twenty-two recording sessions were carried out on singleton pregnant women during the active phase of labour. In each session the following simultaneous recordings were obtained: internal uterine pressure (IUP), external tension of abdominal wall (TOCO) and EHG signals (5 monopolar and 4 bipolar recordings, 1 discrete approximation to the Laplacian of the potential and 2 estimates of the Laplacian from two active annular electrodes). The results obtained show that EHG is able to detect a higher number of uterine contractions than TOCO. Laplacian recordings give improved signal quality over monopolar and bipolar techniques, reduce maternal cardiac interference and improve the signal-to-noise ratio. The optimal position for recording EHG was found to be the uterine median axis and the lower centre-right umbilical zone.


Computational and Mathematical Methods in Medicine | 2014

Automatic Identification of Motion Artifacts in EHG Recording for Robust Analysis of Uterine Contractions

Yiyao Ye-Lin; Javier Garcia-Casado; Gema Prats-Boluda; José Alberola-Rubio; Alfredo Perales

Electrohysterography (EHG) is a noninvasive technique for monitoring uterine electrical activity. However, the presence of artifacts in the EHG signal may give rise to erroneous interpretations and make it difficult to extract useful information from these recordings. The aim of this work was to develop an automatic system of segmenting EHG recordings that distinguishes between uterine contractions and artifacts. Firstly, the segmentation is performed using an algorithm that generates the TOCO-like signal derived from the EHG and detects windows with significant changes in amplitude. After that, these segments are classified in two groups: artifacted and nonartifacted signals. To develop a classifier, a total of eleven spectral, temporal, and nonlinear features were calculated from EHG signal windows from 12 women in the first stage of labor that had previously been classified by experts. The combination of characteristics that led to the highest degree of accuracy in detecting artifacts was then determined. The results showed that it is possible to obtain automatic detection of motion artifacts in segmented EHG recordings with a precision of 92.2% using only seven features. The proposed algorithm and classifier together compose a useful tool for analyzing EHG signals and would help to promote clinical applications of this technique.


Spinal Cord | 2015

Identifying physical activity type in manual wheelchair users with spinal cord injury by means of accelerometers.

X García-Massó; P Serra-Añó; L M Gonzalez; Yiyao Ye-Lin; Gema Prats-Boluda; Javier Garcia-Casado

Study design:This was a cross-sectional study.Objectives:The main objective of this study was to develop and test classification algorithms based on machine learning using accelerometers to identify the activity type performed by manual wheelchair users with spinal cord injury (SCI).Setting:The study was conducted in the Physical Therapy department and the Physical Education and Sports department of the University of Valencia.Methods:A total of 20 volunteers were asked to perform 10 physical activities, lying down, body transfers, moving items, mopping, working on a computer, watching TV, arm-ergometer exercises, passive propulsion, slow propulsion and fast propulsion, while fitted with four accelerometers placed on both wrists, chest and waist. The activities were grouped into five categories: sedentary, locomotion, housework, body transfers and moderate physical activity. Different machine learning algorithms were used to develop individual and group activity classifiers from the acceleration data for different combinations of number and position of the accelerometers.Results:We found that although the accuracy of the classifiers for individual activities was moderate (55–72%), with higher values for a greater number of accelerometers, grouped activities were correctly classified in a high percentage of cases (83.2–93.6%).Conclusions:With only two accelerometers and the quadratic discriminant analysis algorithm we achieved a reasonably accurate group activity recognition system (>90%). Such a system with the minimum of intervention would be a valuable tool for studying physical activity in individuals with SCI.


Physiological Measurement | 2009

Enhancement of the non-invasive electroenterogram to identify intestinal pacemaker activity

Yiyao Ye-Lin; Javier Garcia-Casado; Gema Prats-Boluda; J.L. Ponce; J.L. Martinez-de-Juan

Surface recording of electroenterogram (EEnG) is a non-invasive method for monitoring intestinal myoelectrical activity. However, surface EEnG is seriously affected by a variety of interferences: cardiac activity, respiration, very low frequency components and movement artefacts. The aim of this study is to eliminate respiratory interference and very low frequency components from external EEnG recording by means of empirical mode decomposition (EMD), so as to obtain more robust indicators of intestinal pacemaker activity from the external EEnG signal. For this purpose, 11 recording sessions were performed in an animal model under fasting conditions and in each individual session the myoelectrical signal was recorded simultaneously in the intestinal serosa and the external abdominal surface in physiological states. Various parameters have been proposed for evaluating the efficacy of the method in reducing interferences: the signal-to-interference ratio (S/I ratio), attenuation of the target and interference signals, the normal slow wave percentage and the stability of the dominant frequency (DF) of the signal. The results show that the S/I ratio of the processed signals is significantly greater than the original values (9.66 +/- 4.44 dB versus 1.23 +/- 5.13 dB), while the target signal was barely attenuated (-0.63 +/- 1.02 dB). The application of the EMD method also increased the percentage of the normal slow wave to 100% in each individual session and enabled the stability of the DF of the external signal to be increased considerably. Furthermore, the variation coefficient of the DF derived from the external processed signals is comparable to the coefficient obtained using internal recordings. Therefore, the EMD method could be a very useful tool to improve the quality of external EEnG recording in the low frequency range and therefore to obtain more robust indicators of the intestinal pacemaker activity from non-invasive EEnG recordings.


Measurement Science and Technology | 2016

Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position

Gema Prats-Boluda; Yiyao Ye-Lin; Jm Bueno-Barrachina; R Rodriguez de Sanabria; Javier Garcia-Casado

To overcome the limited spatial resolution of standard 12-lead ECG recordings, concentric ring electrodes (CRE) have been proposed to provide valuable data for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. Although theoretical studies indicate that the dimensions of the CRE regulate the depth of the electric dipoles sensed by these electrodes, this has not been experimentally confirmed. The aim of this work was to analyze the influence of CRE dimensions and position of a wireless multi-CRE sensor node on the cardiac signal recorded. For this, four wireless multichannel ECG recording nodes based on flexible multi-ring electrodes were placed at positions CMV1 (position comparable to V1), CMV2, CMV4R and CMV5; each node providing three bipolar concentric ECG signals (BC-ECG). Standard 12-lead ECG and 12 BC-ECG signals were recorded in 29 volunteers. The results revealed that a ring with an outer diameter of 33.5 mm achieves a balance between the ease-of-use and spatial resolution of smaller electrodes and improved detectability and higher amplitudes of signals from larger ring electrodes. Although a standard 12-lead ECG outperforms BC-ECC recordings in detectability of cardiac waves, if the relative amplitude of the wave is also considered, BC-ECG at CMV1 proved superior at picking up atrial activity. In fact, in most of the BC-ECG signals picked up at CMV1, P1 and P2 atrial activity waves were more clearly identified than in simultaneous 12-Lead ECG signals. Likewise, BC-ECG signals revealed higher spatial resolution in detecting anomalous electrical activity in local regions, such as impaired intraventricular driving, or atrioventricular blocks. Finally, the wireless multi-CRE sensor node provides enhanced comfort and handling to both patient and clinician over wired systems.


Measurement Science and Technology | 2015

Development of a portable wireless system for bipolar concentric ECG recording

Gema Prats-Boluda; Yiyao Ye-Lin; J M Bueno Barrachina; E. Senent; R Rodriguez de Sanabria; Javier Garcia-Casado

Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization).


Microelectronics International | 2015

A comparative analysis of printing techniques by using an active concentric ring electrode for bioelectrical recording

Eduardo Garcia-Breijo; Gema Prats-Boluda; José Vicente Lidón-Roger; Yiyao Ye-Lin; Javier Garcia-Casado

Purpose – This paper aims to present a comparison between three types of manufacturing techniques, namely, screen-printed, inkjet and gravure, using different types of inks, for the implementation of concentric ring electrodes which permit estimation of Laplacian potential on the body surface. Design/methodology/approach – Flexible concentric ring electrodes not only present lower skin–electrode contact impedance and lower baseline wander than rigid electrodes but are also less sensitive to interference and motion artefacts. The above three techniques allow printing of conductive inks on flexible substrates, and with this work, the authors aim to study which is the best technique and ink to obtain the best electrode response. Findings – From the results obtained regarding ink thickness, resistivity, electrode resistance and other performance parameters derived from electrocardiographic signal recording tests, it can be said that concentric electrodes using the screen-printing and inkjet techniques are sui...


international conference of the ieee engineering in medicine and biology society | 2013

Prediction of labor using non-invasive laplacian EHG recordings

Yiyao Ye-Lin; Gema Prats-Boluda; José Alberola-Rubio; Jose-M. Bueno Barrachina; Alfredo Perales; Javier Garcia-Casado

Non-invasive electrohysterogram (EHG) recordings could be used as an alternative technique for monitoring uterine dynamics. Bipolar recordings of EHG have proven to provide valuable information to predict labor. Recently it has been stated that uterine EHG bursts could also be identified in Laplacian recordings on abdominal surface. Taking into account that Laplacian potential technique permits to acquire more localized electrical activity than conventional recordings; these recordings could also be helpful for deducing uterine contraction efficiency. The aim of this paper is to examine the feasibility of Laplacian potential EHG recording for labor prediction and to compare it with monopolar recordings. To this purpose, a total of 42 EHG recordings were acquired from women of similar gestational age: 29 antepartum patients, and 13 patients in labor. Then linear and non-linear classifiers have been implemented using EHG burst parameters as input features. Experimental results show significant differences in temporal and spectral parameters in both monopolar and Laplacian potential recordings between the two groups. In addition, support vector machine based classifier achieved an accuracy of 93% for labor prediction for monopolar recordings, 92% for bipolar recordings and 91% for Laplacian potential.

Collaboration


Dive into the Yiyao Ye-Lin's collaboration.

Top Co-Authors

Avatar

Gema Prats-Boluda

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Javier Garcia-Casado

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

José Alberola-Rubio

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Alfredo Perales

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

Eduardo Garcia-Breijo

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Javier Mas-Cabo

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Carlos Benalcazar-Parra

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

J.L. Martinez-de-Juan

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Victor Zena-Giménez

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar

Alfredo Perales

Instituto Politécnico Nacional

View shared research outputs
Researchain Logo
Decentralizing Knowledge