Yoh Katoh
Tokyo Metropolitan University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Yoh Katoh.
Journal of Applied Clinical Medical Physics | 2015
Michiharu Sekimoto; Yoh Katoh; Tsuguhisa Katoh
A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X‐ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X‐ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X‐ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber‐type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required. PACS number: 87.59.E‐A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X-ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X-ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber-type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required. PACS number: 87.59.E.
Nihon Hōshasen Gijutsu Gakkai zasshi | 2007
Yoh Katoh; Masahiro Fukushi; Shinji Abe; Yoshiyuki Nyui; Tomokazu Numano; Junichi Kimura; Shogo Mita
New Journal of Glass and Ceramics | 2015
Michiharu Sekimoto; Yoh Katoh
Radiological Physics and Technology | 2011
Yoh Katoh; Sogo Mita; Masahiro Fukushi; Yoshiyuki Nyui; Shinji Abe; Junichi Kimura
Nihon Hōshasen Gijutsu Gakkai zasshi | 2010
Yoh Katoh; Masaru Tsukada; Sogo Mita; Masahiro Fukushi; Yoshiyuki Nyui; Shinji Abe; Junichi Kimura
Japanese Journal of Radiological Technology | 1992
Yoh Katoh; Shinji Abe; Izumi Ogura; Kohji Ishiguchi; Yohko Matsui; Hisakazu Moriki; Takao Suzuki
Radioisotopes | 1990
Kenji Saegusa; Masahiro Fukushi; Yoh Katoh; Hidetoshi Saitoh; Toraji Irifune
International Journal of Approximate Reasoning | 2018
Kohei Nishi; Michiharu Sekimoto; Toru Negishi; Yoh Katoh; Akihiro Nakashima; Ijar
Japanese Journal of Radiological Technology | 2017
Takahiro Minamoto; Shuji Koyama; Yoh Katoh
Physics in Medicine and Biology | 2016
Michiharu Sekimoto; Yoh Katoh