Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yoko Hirohara is active.

Publication


Featured researches published by Yoko Hirohara.


Ophthalmology | 2002

Wavefront aberrations measured with Hartmann-Shack sensor in patients with keratoconus.

Naoyuki Maeda; Takashi Fujikado; Teruhito Kuroda; Toshifumi Mihashi; Yoko Hirohara; Kohji Nishida; Hitoshi Watanabe; Yasuo Tano

OBJECTIVE To compare the ocular wavefront aberrations of normal and keratoconic eyes and to describe the characteristics of the higher-order aberrations in eyes with keratoconus. DESIGN Prospective case control and observational study. PARTICIPANTS Thirty-five keratoconic eyes and thirty-eight normal controls. METHODS Higher-order aberrations in refraction were measured with a wavefront sensor, and those aberrations resulting from the cornea were evaluated by videokeratographic data. MAIN OUTCOME MEASURES Coma-like (S(3 + 5)), spherical-like (S(4 + 6)), and total (S(3 + 4 + 5 + 6)) higher-order aberrations in both refraction and the cornea. RESULTS The mean +/- standard deviation of S(3 + 5) (1.88 +/- 1.16), S(4 + 6) (0.70 +/- 0.55), and S(3 + 4 + 5 + 6) (2.03 +/- 1.23) in refraction (6-mm diameter, root mean square, micro m) were significantly higher in the keratoconic eyes than in normal controls (0.26 +/- 0.10, 0.19 +/- 0.10, 0.34 +/- 0.11, respectively; Mann-Whitney U test, P = 0.001). Coma-like aberrations were 2.32 times larger than spherical-like aberrations in keratoconic eyes. CONCLUSIONS The increase of ocular higher-order aberrations in keratoconic eyes results from an increase of corneal higher-order aberrations. Coma-like aberrations were dominant compared with spherical-like aberrations in keratoconic eyes. Wavefront sensing will enable us not only to evaluate the quality of vision but also to differentiate keratoconic eyes from normal eyes by analyzing the characteristics of the higher-order aberrations.


Ophthalmology | 2002

Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis

Tetsuro Oshika; Kazunori Miyata; Tadatoshi Tokunaga; Tomokazu Samejima; Shiro Amano; Sumiyoshi Tanaka; Yoko Hirohara; Toshifumi Mihashi; Naoyuki Maeda; Takashi Fujikado

OBJECTIVE To assess the relation between magnitude of refractive correction and changes in higher order wavefront aberrations of the cornea after laser in situ keratomileusis. DESIGN Prospective, consecutive, nonrandomized comparative trial (self-controlled). PARTICIPANTS One hundred eyes of 53 patients with myopia (-2.0 to -13.0 diopters) were included. INTERVENTION Laser in situ keratomileusis was performed. Videokeratography measurements were conducted before and 1 month after surgery. MAIN OUTCOME MEASURES The videokeratography data were used to calculate the higher order wavefront aberrations of the cornea for both small (3 mm) and large (6 mm) pupils. RESULTS For a 3-mm pupil, the surgery significantly increased coma-like (2.4 +/- 1.3-fold, P < 0.001, paired t test) and spherical-like (1.8 +/- 0.9-fold, P < 0.001) aberrations. For a 6-mm pupil, both coma-like (4.4 +/- 3.3-fold, P < 0.001) and spherical-like (9.4 +/- 5.2-fold, P < 0.001) aberrations were significantly increased by surgery. The amount of achieved correction showed significant correlations with the changes in coma-like (Pearson correlation coefficient r = 0.446, P < 0.001) and spherical-like (r = 0.348, P < 0.001) aberrations for a 3-mm pupil, and coma-like (r = 0.566, P < 0.001) and spherical-like (r = 0.693, P < 0.001) aberrations for a 6-mm pupil. The eyes that lost 2 or more lines of baseline spectacle-corrected visual acuity showed significantly larger induced increases in coma-like (P = 0.003, Mann-Whitney U test) and spherical-like (P = 0.009) aberrations for a 3-mm pupil than those that either improved or remained within 1 line of spectacle-corrected visual acuity CONCLUSIONS Laser in situ keratomileusis, performed using the current algorithms, increases higher order wavefront aberrations of the cornea, dependent on the amount of refractive correction.


American Journal of Ophthalmology | 2002

Effect of tear film break-up on higher-order aberrations measured with wavefront sensor.

Shizuka Koh; Naoyuki Maeda; Teruhito Kuroda; Yuichi Hori; Hitoshi Watanabe; Takashi Fujikado; Yasuo Tano; Yoko Hirohara; Toshifumi Mihashi

PURPOSE To investigate whether optical wavefront aberrations vary with tear film break-up. DESIGN Observational case series. METHODS Higher-order aberrations were examined for 20 eyes of 20 normal subjects with a Hartmann-Shack wavefront sensor before and after tear film break-up. RESULTS Higher-order aberrations for photopic vision (central 4 mm diameter) after tear film break-up increased 1.44 fold compared to higher-order aberrations before tear film break-up (P =.001, paired t-test). Higher-order aberrations after tear film break-up for scotopic vision (central 6 mm diameter) were also 1.23 times higher than those before break-up (P =.005, paired t-test). CONCLUSION Wavefront sensing enabled us to evaluate the induced irregular astigmatism caused by tear film break-up quantitatively. Wavefront aberrations should be measured carefully to avoid the effects of tear film break-up, especially in wavefront-guided refractive surgery.


Journal of Cataract and Refractive Surgery | 2002

Wavefront analysis of higher-order aberrations in patients with cataract ☆

Teruhito Kuroda; Takashi Fujikado; Naoyuki Maeda; Tetsuro Oshika; Yoko Hirohara; Toshifumi Mihashi

Purpose: To determine local refractive changes and higher‐order aberrations in patients with nuclear or cortical cataract. Setting: Osaka University Medical School, Osaka, Japan. Methods: Wavefront analysis of both ocular and corneal aberrations was performed with the Hartmann‐Shack aberrometer in 2 patients, a 22‐year‐old woman with bilateral developmental nuclear cataract and a 68‐year‐old woman with mild bilateral cortical cataract. Results: Case 1 showed a delay in the wavefront that caused a myopic shift in the central pupillary area in both eyes, associated with the nuclear cataract. The spherical‐like aberration (right eye, 36%; left eye, 21%) was greater than the coma‐like aberration in both eyes. Case 2 showed an advancement of the wavefront that caused a hyperopic shift, especially in the lower temporal pupillary area, that was associated with the cortical cataract. The coma‐like aberration (right eye, 63%; left eye, 52%) was greater than the spherical‐like aberration in both eyes. The polarity of the third‐order spherical aberration was negative in Case 1 and positive in Case 2. Corneal higher‐order aberrations were small and had a different distribution than ocular higher‐order aberrations in both patients. Conclusions: The Hartmann‐Shack aberrometer was useful in detecting local refractive changes and higher‐order aberrations in patients with mild cataract. The polarity and the absolute value of ocular higher‐order aberrations may be useful parameters to characterize eyes with cataract.


Investigative Ophthalmology & Visual Science | 2008

Serial Measurements of Higher-Order Aberrations after Blinking in Patients with Dry Eye

Shizuka Koh; Naoyuki Maeda; Yoko Hirohara; Toshifumi Mihashi; Kenichiro Bessho; Yuichi Hori; Tomoyuki Inoue; Hitoshi Watanabe; Takashi Fujikado; Yasuo Tano

PURPOSE To study the sequential postblink changes in ocular higher-order aberrations (HOAs) in patients with dry eye. METHODS A wavefront sensor was used to measure HOAs sequentially for 30 seconds in 20 eyes of 20 patients with dry eye. The 20 eyes were classified into two groups, with or without superficial punctate keratopathy (SPK) in the central cornea. During the measurement, subjects were required to blink every 10 seconds. The aberration data were analyzed in the central 4-mm diameter for coma-like, spherical-like, and total HOAs up to sixth-order Zernike polynomials. Total HOAs, as well as fluctuation index (FI) and stability index (SI) of the total HOAs over time were compared between the two groups. The sequential changes in coma-like aberration, spherical-like aberration, and total HOAs were also investigated. RESULTS The total ocular HOAs were significantly (P = 0.001) greater in dry eyes with central SPK than in dry eyes without central SPK. The sequential pattern of the total ocular HOAs had higher initial and consistently higher values in dry eyes with central SPK, whereas that of dry eyes without central SPK showed consistently lower total HOAs that were similar to the pattern of normal eyes. CONCLUSIONS Increased HOAs in dry eye at least partially result from SPK above the optical zone. The low tear volume in dry eye may not cause sequential increases in HOAs after blinking. Sequential measurement of HOAs may be useful for evaluating the sequential changes in optical quality in patients with dry eye.


Journal of Cataract and Refractive Surgery | 2004

Light scattering and optical aberrations as objective parameters to predict visual deterioration in eyes with cataracts

Takashi Fujikado; Teruhito Kuroda; Naoyuki Maeda; Sayuri Ninomiya; Hiroya Goto; Yasuo Tano; Tetsuro Oshika; Yoko Hirohara; Toshifumi Mihashi

Purpose: To predict the visual deterioration of eyes with cortical (CC) or nuclear (NC) cataract from objective data on ocular higher‐order aberration (HOA) and forward (FLS) and backward light scattering (BLS). Setting: Osaka University Medical School, Osaka, Japan. Methods: Twenty‐two eyes with mild NC, 41 eyes with mild CC, and 11 normal eyes were examined. Higher‐order aberrations were calculated with the Zernike polynomials up to the fourth order from the values obtained by wavefront analysis using the Hartmann‐Shack aberrometer. Forward light scattering was calculated from the size of the aberrometer spot images for the central 4 mm, and backward light scattering (BLS) was calculated from the optical density of the Scheimpflug images. The relationship between the area under the log contrast sensitivity function (AULCSF) curve and HOAs, FLS, and BLS was examined. Results: Area under the log contrast sensitivity function was moderately correlated with the HOAs, FLS, and BLS. Multiple linear regression analysis revealed that the AULCSF was predicted by the linear combination of these variables (R2=.484, P<.001). Area under the log contrast sensitivity was predicted by BLS and HOA (R2=.555) in the NC group and by FLS and HOAs (R2=.540) in the CC group. Conclusions: Loss of contrast sensitivity was predominantly due to BLS and HOA in eyes with NC and FLS and HOA in eyes with CC. Higher‐order aberrations, FLS, and BLS, variables that are obtained objectively, can be used to predict quantitatively the visual deterioration in cataractous eyes.


Journal of Refractive Surgery | 2002

Effect of Aging on Ocular Light Scatter and Higher Order Aberrations

Teruhito Kuroda; Takashi Fujikado; Sayuri Ninomiya; Naoyuki Maeda; Yoko Hirohara; Toshifumi Mihashi

PURPOSE To study the effect of aging on ocular light scatter and higher order aberrations in humans. METHODS Seventy-six eyes of 76 normal subjects who had refractive errors but no ocular disease were studied. Their age ranged from 4 to 69 years (mean 34.8 +/- 5.8 yr). Both light scatter and total higher order aberrations were simultaneously and quantitatively measured by a Hartmann-Shack sensor for the central 4-mm-diameter pupil. Higher order aberrations were calculated from the Zernike polynomials up to the 4th order. The amount of light scatter was estimated by using the diameter of the point spread functions (PSFs) of the Hartmann images. A correction was made for the effect of the aberrations on the width of the images. Linear regression analysis was performed to investigate the effect of aging on light scatter and total higher order aberrations. RESULTS A significant correlation was found between scatter and age (Spearman rank correlation coefficient, r = 0.501, P = .001). Also, the total higher order aberrations increased significantly with age (r = 0.323, P = .005). The total higher order aberration and scatter index were not statistically significantly correlated (r = 0.184, P = .112). CONCLUSIONS These results indicate that scatter was better correlated with age than higher order aberrations.


Cornea | 2008

Effects of suppression of blinking on quality of vision in borderline cases of evaporative dry eye.

Shizuka Koh; Naoyuki Maeda; Yuichi Hori; Tomoyuki Inoue; Hitoshi Watanabe; Yoko Hirohara; Toshifumi Mihashi; Takashi Fujikado; Yasuo Tano

Purpose: To study the effects of suppression of blinking on quality of vision in borderline cases of evaporative dry eye. Methods: Ocular higher-order aberrations (HOAs) were measured sequentially for 30 seconds in 10 eyes with a short tear film breakup time (TBUT; 3.0 ± 0.6 seconds) without ocular surface staining or tear deficiency. During measurements, the subjects suppressed blinking to every 10 seconds, which is more than double the TBUT. The aberration data were analyzed for comalike and spherical-like aberrations and total HOAs to the sixth-order Zernike polynomials. Results: Sequential changes in total HOAs in subjects with a short TBUT showed a sawtooth pattern with a marked upward curve that increased after blinking. From 5 to 9 seconds after blinking, the total HOAs were significantly higher than immediately after blinking (P < 0.001). Conclusions: Serial HOA measurements showed that optical quality might deteriorate in subjects with a short TBUT by suppressed blinking, such as when gazing at a video display terminal, even with sufficient tear volume.


Journal of Cataract and Refractive Surgery | 2008

Characteristics of ocular higher-order aberrations in patients with pellucid marginal corneal degeneration.

Yoshinori Oie; Naoyuki Maeda; Ryo Kosaki; Asaki Suzaki; Yoko Hirohara; Toshifumi Mihashi; Yuichi Hori; Tomoyuki Inoue; Kohji Nishida; Takashi Fujikado; Yasuo Tano

PURPOSE: To evaluate the characteristics of higher‐order aberrations (HOAs) in eyes with pellucid marginal corneal degeneration (PMCD). SETTING: Department of Ophthalmology, Osaka University Medical School, Osaka, Japan. METHODS: Ocular HOAs were measured by aberrometry in 20 eyes with PMCD (PMCD group), 76 eyes with keratoconus (KC group), and 105 normal eyes (control group) with a 4.0 mm pupil. The magnitudes and axes of trefoil, coma, tetrafoil, and secondary astigmatism and the magnitude of spherical aberration were compared between the 3 groups using vector analysis of Zernike terms. RESULTS: The mean axes of coma in the PMCD group (85.5 degrees) and KC group (82.5 degrees) were opposite the axis in the control group (253.7 degrees). The magnitude of coma was significantly lower in the PMCD group (0.27 μm ± 0.19 [SD]) than in the KC group (0.70 ± 0.37 μm) (P<.05). The mean axes of trefoil in the PMCD group (27.1 degrees) and control group (35.4 degrees) were opposite the axis in the KC group (93.8 degrees). The magnitude of spherical aberration was significantly higher in the PMCD group (0.086 ± 0.10 μm) than in the KC group (−0.030 ± 0.13 μm) (P<.05); the spherical aberration signs were opposite in the groups. CONCLUSIONS: Although PMCD and KC are categorized as noninflammatory corneal thinning disorders, the HOA patterns in the 2 groups differed, possibly due to differences in the positions of the corneal apex. PMCD and KC may cause distinctively different deterioration in the quality of vision.


Japanese Journal of Ophthalmology | 2006

Tear Film Break-up Time Evaluated by Real-Time Hartmann-Shack Wavefront Sensing

Toshifumi Mihashi; Yoko Hirohara; Shizuka Koh; Sayuri Ninomiya; Naoyuki Maeda; Takashi Fujikado

PurposeTo develop a novel method for measuring tear break-up time (BUT) by continuously measuring higher order wavefront aberrations using a Hartmann-Shack (H-S) aberrometer.MethodsWavefront aberrations up to the sixth order for a 4-mm pupil were measured in six eyes of six normal subjects using an H-S aberrometer. The aberrometry was performed once every second for up to 50 s under topical anesthesia. The sequence of the points was divided into two stages, and the BUT was defined as the wavefront border of the stages (WFBUT). The WFBUT was compared with the BUT by the conventional fluorescein method (FLBUT) or by the disruption of placid-ring images (PLBUT).ResultsIn three eyes, the WFBUT (average, 10.9 ± 1.1 s) was shorter than the PLBUT (average, 17.5 ± 2.5 s), while in the other three eyes the WFBUT (average, 21.5 ± 2.2 s) was longer than PLBUT (average, 8.1 ± 2.2 s). The FLBUT was shorter than WFBUT or PLBUT in most cases.ConclusionsThe tear break-up time measured by H-S aberrometer may be used as a practical measure of tear break-up. Jpn J Ophthalmol 2006;50:85–89

Collaboration


Dive into the Yoko Hirohara's collaboration.

Top Co-Authors

Avatar

Toshifumi Mihashi

Tokyo Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge