Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yon Mi Sung is active.

Publication


Featured researches published by Yon Mi Sung.


American Journal of Roentgenology | 2007

Efficacy of Helical Dynamic CT Versus Integrated PET/CT for Detection of Mediastinal Nodal Metastasis in Non-Small Cell Lung Cancer

Chin A Yi; Kyung Soo Lee; Byung-Tae Kim; Sung Shine Shim; Myung Jin Chung; Yon Mi Sung; Sun Young Jeong

OBJECTIVE The purpose of our study was to compare the diagnostic efficacies of helical dynamic CT and integrated PET/CT for the prediction of mediastinal nodal metastasis in stage T1 non-small cell lung cancer (NSCLC). MATERIALS AND METHODS One hundred forty-three patients with stage T1 NSCLC underwent both helical dynamic CT and integrated PET/CT followed by surgical nodal staging. In helical dynamic CT, patients were regarded to have stage N2 disease when a nodule showed a peak enhancement > or = 110 H or a net enhancement > or = 60 H. In integrated PET/CT, nodes were regarded as positive for malignancy when they showed > or = 3.5 in maximum standardized uptake value with a discrete margin and more 18F-FDG uptake than mediastinal structures. Sensitivities, specificities, and accuracies for mediastinal nodal metastasis detection were compared for helical dynamic CT and integrated PET/CT using the McNemar test. RESULTS Of the 143 patients, 34 (24%) had positive mediastinal nodes. The sensitivity, specificity, and accuracy for mediastinal nodal metastasis prediction on helical dynamic CT were 65% (22 of 34 patients), 89% (97 of 109), and 83% (119 of 143), respectively, whereas those on integrated PET/CT were 56% (19 of 34), 100% (109 of 109), and 90% (128 of 143). The p values were 0.664, < 0.001, and 0.015. CONCLUSION In stage T1 NSCLC, contrast-enhanced helical dynamic CT better predicts, but not significantly so, mediastinal nodal metastasis than PET/CT, whereas PET/CT shows perfect specificity and higher accuracy than helical dynamic CT.


Korean Journal of Radiology | 2004

Radiofrequency ablation of rabbit liver in vivo: effect of the pringle maneuver on pathologic changes in liver surrounding the ablation zone.

Seung Kwon Kim; Hyo Keun Lim; Jeong-Ah Ryu; Dongil Choi; Won Jae Lee; Ji-Yeon Lee; Ju-Hyun Lee; Yon Mi Sung; Eun Yoon Cho; Seung-Mo Hong; Jong-Sung Kim

Objective We wished to evaluate the effect of the Pringle maneuver (occlusion of both the hepatic artery and portal vein) on the pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone in rabbit livers. Materials and Methods Radiofrequency (RF) ablation zones were created in the livers of 24 rabbits in vivo by using a 50-W, 480-kHz monopolar RF generator and a 15-gauge expandable electrode with four sharp prongs for 7 mins. The tips of the electrodes were placed in the liver parenchyma near the porta hepatis with the distal 1 cm of their prongs deployed. Radiofrequency ablation was performed in the groups with (n=12 rabbits) and without (n=12 rabbits) the Pringle maneuver. Three animals of each group were sacrificed immediately, three days (the acute phase), seven days (the early subacute phase) and two weeks (the late subacute phase) after RF ablation. The ablation zones were excised and serial pathologic changes in the hepatic vessels, bile ducts and liver parenchyma surrounding the ablation zone were evaluated. Results With the Pringle maneuver, portal vein thrombosis was found in three cases (in the immediate [n=2] and acute phase [n=1]), bile duct dilatation adjacent to the ablation zone was found in one case (in the late subacute phase [n=1]), infarction adjacent to the ablation zone was found in three cases (in the early subacute [n=2] and late subacute [n=1] phases). None of the above changes was found in the livers ablated without the Pringle maneuver. On the microscopic findings, centrilobular congestion, sinusoidal congestion, sinusoidal platelet and neutrophilic adhesion, and hepatocyte vacuolar and ballooning changes in liver ablated with Pringle maneuver showed more significant changes than in those livers ablated without the Pringle maneuver (p < 0.05) Conclusion Radiofrequency ablation with the Pringle maneuver created more severe pathologic changes in the portal vein, bile ducts and liver parenchyma surrounding the ablation zone compared with RF ablation without the Pringle maneuver. Therefore, we suggest that RF ablation with the Pringle maneuver should be performed with great caution in order to avoid unwanted thermal injury.


American Journal of Roentgenology | 2006

Pulmonary Sclerosing Hemangioma Presenting as Solitary Pulmonary Nodule: Dynamic CT Findings and Histopathologic Comparisons

Myung Jin Chung; Kyung Soo Lee; Joungho Han; Yon Mi Sung; Semin Chong; O Jung Kwon

OBJECTIVE The purpose of this study was to describe the dynamic CT findings of pulmonary sclerosing hemangioma presenting as a solitary pulmonary nodule and to compare these findings with histopathologic findings. CONCLUSION On dynamic CT, sclerosing hemangioma has strong and rapid enhancement attributed histopathologically to the presence of hemangiomatous or papillary components in the tumor.


Korean Journal of Radiology | 2008

18F-FDG PET versus 18F-FDG PET/CT for Adrenal Gland Lesion Characterization: a Comparison of Diagnostic Efficacy in Lung Cancer Patients

Yon Mi Sung; Kyung Soo Lee; Byung-Tae Kim; Joon Young Choi; Myung Jin Chung; Young Mog Shim; Chin A Yi; Tae Sung Kim

Objective The aim of this study was to assess the diagnostic efficacy of integrated PET/CT using fluorodeoxyglucose (FDG) for the differentiation of benign and metastatic adrenal gland lesions in patients with lung cancer and to compare the diagnostic efficacy with the use of PET alone. Materials and Methods Sixty-one adrenal lesions (size range, 5-104 mm; mean size, 16 mm) were evaluated retrospectively in 42 lung cancer patients. Both PET images alone and integrated PET/CT images were assessed, respectively, at two-month intervals. PET findings were interpreted as positive if the FDG uptake of adrenal lesions was greater than or equal to that of the liver, and the PET/CT findings were interpreted as positive if an adrenal lesion show attenuation > 10 HU and showed increased FDG uptake. Final diagnoses of adrenal gland lesions were made at clinical follow-up (n = 52) or by a biopsy (n = 9) when available. The diagnostic accuracies of PET and PET/CT for the characterization of adrenal lesions were compared using the McNemar test. Results Thirty-five (57%) of the 61 adrenal lesions were metastatic and the remaining 26 lesions were benign. For the depiction of adrenal gland metastasis, the sensitivity, specificity, and accuracy of PET were 74%, 73%, and 74%, respectively, whereas those of integrated PET/CT were 80%, 89%, and 84%, respectively (p values; 0.5, 0.125, and 0.031, respectively). Conclusion The use of integrated PET/CT is more accurate than the use of PET alone for differentiating benign and metastatic adrenal gland lesions in lung cancer patients.


Korean Journal of Radiology | 2006

Long-term Results of Percutaneous Ethanol Injection for the Treatment of Hepatocellular Carcinoma in Korea

Yon Mi Sung; Dongil Choi; Hyo Keun Lim; Won Jae Lee; Seung Hoon Kim; Min Ju Kim; Seung Woon Paik; Byung Chul Yoo; Kwang Cheol Koh; Joon Hyoek Lee; Moon Seok Choi

Objective To evaluate the long-term follow-up results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in Korea. Materials and Methods Sixty-eight nodular HCCs initially detected in 64 patients, were subjected to US-guided PEI as a first-line treatment. Long-term survival rates, local tumor progression rates, and complications were evaluated, as were the influences of tumor size and Child-Pugh class on these variables. Results No major complications occurred. The overall survival rates of the 64 patients at three and five years were 71% and 39%, and their cancer-free survival rates were 22% and 15%, respectively. The overall survival rate of patients with a small HCC (≤ 2 cm) was significantly higher (p = 0.014) than that of patients with a medium-sized HCC (≤ 2 cm). The overall survival rate of patients with Child-Pugh class A was significantly higher (p = 0.049) than that of patients with Child-Pugh class B. Of 59 cases with no residual tumor, local tumor progression was observed in ablation zones in 18, and this was not found to be significantly influenced by tumor size or Child-Pugh class. Conclusion The results of our investigation of the long-term survival rates of PEI in HCC patients in Korea (a hepatitis B virus-endemic area) were consistent with those reported previously in hepatitis C endemic areas. Patients with a smaller tumor or a better liver function exhibited superior survival rates.


Korean Journal of Radiology | 2006

The Balloon Dilatation and Large Profile Catheter Maintenance Method for the Management of the Bile Duct Stricture Following Liver Transplantation

Sung Wook Choo; Sung Wook Shin; Young Soo Do; Wei Chiang Liu; Kwang Bo Park; Yon Mi Sung; In Wook Choo

Objective We wanted to evaluate the therapeutic efficacy of the percutaneous balloon dilatation and large profile catheter maintenance method for the management of patients with anastomotic biliary strictures following liver transplant. Materials and Methods From May 1999 to June 2003, 12 patients with symptomatic benign biliary stricture complicated by liver transplantation were treated with the percutaneous balloon dilatation and large profile catheter maintenance method (1-6 months). The patients were eight males and four females, and their ages ranged from 20 to 62 years (mean age: 44 years). Ten patients underwent living donor liver transplantation and two underwent cadaveric liver transplantation. Postoperative biliary strictures occurred from two to 21 months (mean age: 18 months) after liver transplantation. Results The initial technical success rate was 92%. Patency of the bile duct was preserved for eight to 40 months (mean period: 19 months) in 10 of 12 (84%) patients. When reviewing two patients (17%), secondary balloon dilatations were needed for treating the delayed recurrence of biliary stricture. In one patient, no recurrent stenosis was seen during the further 10 months follow-up after secondary balloon dilatation. Another patient did not response to secondary balloon dilatation, and he was treated by surgery. Eleven of 12 patients (92%) showed good biliary patency for 8-40 months (mean period: 19 months) of follow-up. Conclusion The percutaneous balloon dilatation and large profile catheter maintenance method is an effective therapeutic alternative for the treatment of most biliary strictures that complicate liver transplantation. It has a high success rate and it should be considered before surgery.


Korean Journal of Radiology | 2003

Selective Intra-Arterial Calcium Stimulation with Hepatic Venous Sampling for Preoperative Localization of Insulinomas

Yon Mi Sung; Young Soo Do; Moon-Kyu Lee; Sung Wook Shin; Wei Chiang Liu; Sung Wook Choo; In-Wook Choo

Objective To determine the value of selective intra-arterial calcium stimulation with hepatic venous sampling using serum insulin and C-peptide gradients for the preoperative localization of insulinomas. Materials and Methods Seven consecutive patients [three men and four women aged 15-77 (mean, 42.7) years] with hypoglycemia underwent selective intra-arterial calcium stimulation in conjunction with hepatic venous sampling. Insulin gradients were calculated by an individual blinded to all other preoperative imaging studies and operative findings. In all patients except one, C-peptide gradients were also analyzed. The results were compared with the preoperative findings of ultrasonography, computed tomography, arteriography and endoscopic ultrasonography, as well as with the intraoperative findings of ultrasonography and palpation at surgery. Results Eight insulinomas (mean diameter, 12.5 mm) were diagnosed after surgery. In six patients, the calcium stimulation test with insulin gradients allowed accurate localization of the pathologic source of insulin secretion. Both C-peptide and insulin gradients substantially increased diagnostic accuracy. In one patient, C-peptide gradients were more helpful than insulin gradients for tumor localization. Conclusion Selective intra-arterial calcium stimulation with hepatic venous sampling is a highly accurate and safe method for the preoperative localization of insulinomas. Additional C-peptide gradients seem to be helpful in assessing tumor location, but further study is needed.


Journal of Computer Assisted Tomography | 2003

Additional coronal images using low-milliamperage multidetector-row computed tomography: effectiveness in the diagnosis of bronchiectasis.

Yon Mi Sung; Kyung Soo Lee; Chin A Yi; Young Cheol Yoon; Tae Sung Kim; Seonwoo Kim

Purpose The aim of our study was to evaluate the effectiveness of additional coronal images using low-milliamperage multidetector-row computed tomography (CT) in the diagnosis of bronchiectasis. Methods Helical volumetric CT scans (120 kVp, 70 mA, 2.5-mm collimation, table speed of 15 mm/s, table rotation time of 1 second) using low-milliamperage multidetector-row CT were obtained through the thorax in 110 patients who were suspected of bronchiectasis. Both axial (2.5-mm section thickness) and coronal (1.3–2.0-mm section thickness) reformatted images were made and sent to picture archiving and communication system (PACS) monitors. Two independent observers assessed CT scans twice; with axial images only and with both axial and coronal images. The detection rates of bronchiectasis were compared between readings with axial images only and with both axial and coronal images by using a nonparametric method of clustered data. Confidence grades were given to the distribution and type of bronchiectasis. Results With axial images only, the detection rates of bronchiectasis on a per-patient basis were 97% (213/220 patients, &kgr; = 0.888) whereas with both axial and coronal images, the detection rates were 100% (220/220 patients, &kgr; = 1.000) (P = 0.0001). Confidence to the distribution of bronchiectasis was greater with both axial and coronal images than with axial images only (P = 0.008). Conclusions Additional coronal images using low-milliamperage multidetector-row CT are effective in the diagnosis of bronchiectasis by providing enhanced detection rates and confidence to the distribution of lesions.


European Journal of Radiology | 2010

The influence of liquid crystal display monitors on observer performance for the detection of interstitial lung markings on both storage phosphor and flat-panel-detector chest radiography

Yon Mi Sung; Myung Jin Chung; Kyung Soo Lee; Bong-Keun Choe

PURPOSE To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode ray tube (CRT) monitor in the detection of interstitial lung markings using a silicon flat-panel-detector direct radiography (DR) and storage phosphor computed radiography (CR) in a clinical setting. MATERIALS AND METHODS We displayed 39 sets of posteroanterior chest radiographs from the patients who were suspected of interstitial lung disease. Each sets consisted of DR, CR and thin-section CT as the reference standard. Image identities were masked, randomly sorted, and displayed on both five mega pixel (2048x2560x8 bits) LCD and CRT monitors. Ten radiologists independently rated their confidence in detection for the presence of linear opacities in the four fields of the lungs; right upper, left upper, right lower, and left lower quadrant. Performance of a total 6240 (39 setsx2 detector systemsx2 monitor systemx4 fieldsx10 observers) observations was analyzed by multi-reader multi-case receiver operating characteristic (ROC) analysis. Differences between monitor systems in combinations of detector systems were compared using ANOVA and paired-samples t-test. RESULTS Area under curves (AUC) for the presence of linear opacities measured by ROC analysis was higher on the LCDs than CRTs without statistical significance (p=0.082). AUC was significantly higher on the DR systems than CR systems (p=0.006). AUC was significantly higher on the LCDs than CRTs for DR systems (p=0.039) but not different for CR systems (p=0.301). CONCLUSION In clinical conditions, performance of the LCD monitor appears to be better for detecting interstitial lung markings when interfaced with DR systems.


Journal of Computer Assisted Tomography | 2015

Ghost in the left ventricle on electrocardiogram-gated cardiac computed tomography by turbulent flow.

Sung Su Byun; Yon Mi Sung; Kyounghoon Lee; Yoon Kyung Kim; Jae Hyung Park

We report on an extremely rare case of a fake lesion in the left ventricle on electrocardiogram-gated cardiac computed tomography simulating thrombus or tumor by turbulent flow in a 14-year-old boy. Cardiac magnetic resonance imaging with contrast-enhanced myocardial perfusion and delayed enhancement images were helpful in excluding true thrombus or tumor. Awareness of this potential pitfall is critical in order to avoid unnecessary anticoagulation or surgery.

Collaboration


Dive into the Yon Mi Sung's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Chin A Yi

Samsung Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tae Sung Kim

Sungkyunkwan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dongil Choi

Samsung Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge