Yonatan Chatzinoff
University of Texas Southwestern Medical Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Yonatan Chatzinoff.
International Journal of Hyperthermia | 2015
Chenchen Bing; Joris Nofiele; Robert Staruch; Michelle Ladouceur-Wodzak; Yonatan Chatzinoff; Ashish Ranjan; Rajiv Chopra
Abstract Purpose: Localised hyperthermia in rodent studies is challenging due to the small target size. This study describes the development and characterisation of an MRI-compatible high-intensity focused ultrasound (HIFU) system to perform localised mild hyperthermia treatments in rodent models. Material and methods: The hyperthermia platform consisted of an MRI-compatible small animal HIFU system, focused transducers with sector-vortex lenses, a custom-made receive coil, and means to maintain systemic temperatures of rodents. The system was integrated into a 3T MR imager. Control software was developed to acquire images, process temperature maps, and adjust output power using a proportional-integral-derivative feedback control algorithm. Hyperthermia exposures were performed in tissue-mimicking phantoms and in a rodent model (n = 9). During heating, an ROI was assigned in the heated region for temperature control and the target temperature was 42 °C; 30 min mild hyperthermia treatment followed by a 10-min cooling procedure was performed on each animal. Results: 3D-printed sector-vortex lenses were successful at creating annular focal regions which enables customisation of the heating volume. Localised mild hyperthermia performed in rats produced a mean ROI temperature of 42.1 ± 0.3 °C. The T10 and T90 percentiles were 43.2 ± 0.4 °C and 41.0 ± 0.3 °C, respectively. For a 30-min treatment, the mean time duration between 41–45 °C was 31.1 min within the ROI. Conclusions: The MRI-compatible HIFU system was successfully adapted to perform localised mild hyperthermia treatment in rodent models. A target temperature of 42 °C was well-maintained in a rat thigh model for 30 min.
Investigative Radiology | 2017
Daniel N. Costa; Yonatan Chatzinoff; Niccolò Passoni; Payal Kapur; Claus G. Roehrborn; Yin Xi; Neil M. Rofsky; Jose Torrealba; Franto Francis; Cecil Futch; Phyllis Hagens; Hollis Notgrass; Susana Otero-Muinelo; Ivan Pedrosa; Rajiv Chopra
Objectives The aim of this study was to compare the anatomical registration of preoperative magnetic resonance imaging (MRI) and prostate whole-mount obtained with 3D-printed, patient-specific, MRI-derived molds (PSM) versus conventional whole-mount sectioning (WMS). Materials and Methods Based on an a priori power analysis, this institutional review board–approved study prospectively included 50 consecutive men who underwent 3 T multiparametric prostate MRI followed by radical prostatectomy. Two blinded and independent readers (R1 and R2) outlined the contours of the prostate, tumor, peripheral, and transition zones in the MRI scans using regions of interest. These were compared with the corresponding regions of interest from the whole-mounted histopathology, the reference standard, using PSM whole-mount results obtained in the study group (n = 25) or conventional WMS in the control group (n = 25). The spatial overlap across the MRI and histology data sets was calculated using the Dice similarity coefficient (DSC) for the prostate overall (DSCprostate), tumor (DSCtumor), peripheral (DSCPZ), and transition (DSCTZ) zone. Results in the study and control groups were compared using Wilcoxon rank sum test. Results The MRI histopathology anatomical registration for the prostate gland overall, tumor, peripheral, and transition zones were significantly superior with the use of PSMs (DSCs for R1: 0.95, 0.86, 0.84, and 0.89; for R2: 0.93, 0.75, 0.78, and 0.85, respectively) than with the use of standard WMS (R1: 0.85, 0.46, 0.66, and 0.69; R2: 0.85, 0.46, 0.66, and 0.69) (P < 0.0001). Conclusions The use of PSMs for prostate specimen whole-mount sectioning provides significantly superior anatomical registration of in vivo multiparametric MRI and ex vivo prostate whole-mounts than conventional WMS.
Skeletal Radiology | 2016
Joseph Zerr; Yonatan Chatzinoff; Rajiv Chopra; Kenneth Estrera; Avneesh Chhabra
Three dimensional (3D) printing can be used to create material models to aid preoperative planning of complex orthopedic procedures as exemplified by this case of total hip arthroplasty failure due to infection with resulting severe acetabular bone stock deficiency. The 3D model allowed for trialing of the acetabular component to determine cup size, position, and screw placement. Most importantly, the model confirmed that there was not a pelvic discontinuity and the revision shell would be sufficient for the reconstruction. Previously, the cost and complexity of utilization of 3D printers were prohibitive. Recent improvements in commercially available 3D printers have made rapid prototype model creation a realistic option, which can facilitate difficult surgery.
Scientific Reports | 2017
Rajiv Chopra; Sumbul Shaikh; Yonatan Chatzinoff; Imalka Munaweera; Bingbing Cheng; Seth M. Daly; Yin Xi; Chenchen Bing; Dennis K. Burns; David Greenberg
Treatment of prosthetic joint infection (PJI) usually requires surgical replacement of the infected joint and weeks of antibiotic therapy, due to the formation of biofilm. We introduce a non-invasive method for thermal destruction of biofilm on metallic implants using high-frequency (>100 kHz) alternating magnetic fields (AMF). In vitro investigations demonstrate a >5-log reduction in bacterial counts after 5 minutes of AMF exposure. Confocal and scanning electron microscopy confirm removal of biofilm matrix components within 1 minute of AMF exposure, and combination studies of antibiotics and AMF demonstrate a 5-log increase in the sensitivity of Pseudomonas aeruginosa to ciprofloxacin. Finite element analysis (FEA) simulations demonstrate that intermittent AMF exposures can achieve uniform surface heating of a prosthetic knee joint. In vivo studies confirm thermal damage is confined to a localized region (<2 mm) around the implant, and safety can be achieved using acoustic monitoring for the presence of surface boiling. These initial studies support the hypothesis that AMF exposures can eradicate biofilm on metal implants, and may enhance the effectiveness of conventional antibiotics.
Urology | 2017
Durgesh Kumar Dwivedi; Yonatan Chatzinoff; Yue Zhang; Qing Yuan; Michael Fulkerson; Rajiv Chopra; James Brugarolas; Jeffrey A. Cadeddu; Payal Kapur; Ivan Pedrosa
OBJECTIVE To implement a platform for colocalization of in vivo quantitative multiparametric magnetic resonance imaging features with ex vivo surgical specimens of patients with renal masses using patient-specific 3-dimensional (3D)-printed tumor molds, which may aid in targeted tissue procurement and radiomics and radiogenomic analyses. MATERIALS AND METHODS Volumetric segmentation of 6 renal masses was performed with 3D Slicer (http://www.slicer.org) to create a 3D tumor model. A slicing guide template was created with specialized software, which included notches corresponding to the anatomic locations of the magnetic resonance images. The tumor model was subtracted from the slicing guide to create a depression in the slicing guide corresponding to the exact size and shape of the tumor. A customized, tumor-specific, slicing guide was then printed using a 3D printer. After partial nephrectomy, the surgical specimen was bivalved through the preselected magnetic resonance imaging (MRI) plane. A thick slab of the tumor was obtained, fixed, and processed as a whole-mount slide and was correlated to multiparametric MRI findings. RESULTS All patients successfully underwent partial nephrectomy and adequate fitting of the tumor specimens within the 3D mold was achieved in all tumors. Distinct in vivo MRI features corresponded to unique pathologic characteristics in the same tumor. The average cost of printing each mold was US
Scientific Reports | 2018
Zhiyue J. Wang; Yong Jong Park; Michael C. Morriss; Youngseob Seo; Trung Nguyen; Rami R. Hallac; Ana Nava; Rajiv Chopra; Yonatan Chatzinoff; Khyana Price; Nancy Rollins
160.7 ± 111.1 (range: US
PLOS ONE | 2018
Bingbing Cheng; Yonatan Chatzinoff; Debby Szczepanski; Chenchen Bing; Sumbul Shaikh; Omar Wyman; Cameron E. Perry; James A. Richardson; Dennis K. Burns; Bret M. Evers; David Greenberg; Rajiv Chopra
20.9-
Archive | 2018
Rajiv Chopra; David Greenberg; Yonatan Chatzinoff
350.7). CONCLUSION MRI-based preoperative 3D printing of tumor-specific molds allow for accurate sectioning of the tumor after surgical resection and colocalization of in vivo imaging features with tissue-based analysis in radiomics and radiogenomic studies.
Bulletin of the American Physical Society | 2018
Sebastian Fonseca; Rajiv Chopra; Yonatan Chatzinoff
Susceptibility artifacts caused by stainless steel orthodontic appliances (braces) pose significant challenges in clinical brain MRI examinations. We introduced field correction device (FCD) utilizing permanent magnets to cancel the induced B0 inhomogeneity and mitigate geometric distortions in MRI. We evaluated a prototype FCD using a 3D-printed head phantom in this proof of concept study. The phantom was compartmented into anterior frontal lobe, temporal lobe, fronto-parieto-occipital lobe, basal ganglia and thalami, brain stem, and cerebellum and had built-in orthogonal gridlines to facilitate the quantification of geometric distortions and volume obliterations. Stainless steel braces were mounted on dental models of three different sizes with total induced magnetic moment 0.15 to 0.17 A·m2. With braces B0 standard deviation (SD) ranged from 2.8 to 3.7 ppm in the temporal and anterior frontal lobes vs. 0.2 to 0.3 ppm without braces. The volume of brain regions in diffusion weighted imaging was obliterated by 32–38% with braces vs. 0% without braces in the cerebellum. With the FCD the SD of B0 ranged from 0.3 to 1.2 ppm, and obliterated volume ranged from 0 to 6% in the corresponding brain areas. These results showed that FCD can effectively decrease susceptibility artifacts from orthodontic appliances.
British Journal of Radiology | 2018
Lihua Zhang; Joel E Wells; Riham Dessouky; Adam Gleason; Rajiv Chopra; Yonatan Chatzinoff; Nicholas P. Fey; Yin Xi; Avneesh Chhabra
Treatment of prosthetic joint infections often involves multiple surgeries and prolonged antibiotic administration, resulting in a significant burden to patients and the healthcare system. We are exploring a non-invasive method to eradicate biofilm on metal implants utilizing high-frequency alternating magnetic fields (AMF) which can achieve surface induction heating. Although proof-of-concept studies demonstrate the ability of AMF to eradicate biofilm in vitro, there is a legitimate safety concern related to the potential for thermal damage to surrounding tissues when considering heating implanted metal objects. The goal of this study was to explore the feasibility of detecting acoustic emissions associated with boiling at the interface between a metal implant and surrounding soft tissue as a wireless safety sensing mechanism. Acoustic emissions generated during in vitro and in vivo AMF exposures were captured with a hydrophone, and the relationship with surface temperature analyzed. The effect of AMF exposure power, surrounding media composition, implant location within the AMF transmitter, and implant geometry on acoustic detection during AMF therapy was also evaluated. Acoustic emissions were reliably identified in both tissue-mimicking phantom and mouse studies, and their onset coincided with the implant temperature reaching the boiling threshold. The viscosity of the surrounding medium did not impact the production of acoustic emissions; however, emissions were not present when the medium was oil due to the higher boiling point. Results of simulations and in vivo studies suggest that short-duration, high-power AMF exposures combined with acoustic sensing can be used to minimize the amount of thermal damage in surrounding tissues. These studies support the hypothesis that detection of boiling associated acoustic emissions at a metal/tissue interface could serve as a real-time, wireless safety indicator during AMF treatment of biofilm on metallic implants.