Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yoshiharu Azuma is active.

Publication


Featured researches published by Yoshiharu Azuma.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 1996

Effects of sustained unilateral molar clenching on the temporomandibular joint space

Takuo Kuboki; Yoshiharu Azuma; Maria G. Orsini; Yasushi Takenami; Atsushi Yamashita

OBJECTIVEnTo measure the effect of unilateral sustained clenching on the temporomandibular joints, changes in the minimum joint space dimension were assessed.nnnSTUDY DESIGNnTen healthy subjects performed a sustained clench on a bite force transducer in the first molar region for 5 minutes with a constant force of 170 N. Three separate sagittal tomograms were bilaterally obtained with the transducer in place before clenching and during the beginning and at the end of the contraction. Changes were quantified with a computerized image analysis system.nnnRESULTSnThe minimum joint space of the contralateral temporomandibular joint was significantly reduced both at the beginning and at the end of the contraction task. Further the minimum joint space was also significantly less at the end than at the beginning of the contraction even though bite force level was identical. The ipsilateral condyle images showed no significant shift in the minimum joint space.nnnCONCLUSIONSnThese data suggest that unilateral molar clenching induces a significant reduction of the minimum joint space in the contralateral temporomandibular joint and a sustained condition remarkably increases this change.


international conference on industrial technology | 2002

Detection of defects at BGA solder joints by using X-ray imaging

Tetsuhiro Sumimoto; T. Maruyamay; Yoshiharu Azuma; Sachiko Goto; M. Mondo; N. Furukawa; Saburo Okada

In the surface mount technology, a ball grid array (BGA) has been used in the production of PC boards. This paper deals with the detection of defects at BGA solder joints in PC boards by using X-ray imaging. Types of defects at BGA solder joints are solder bridge, missing connection, solder voids, open connection and misregistration of parts. The problems of image analysis for the detection of defects at BGA solder joints are the detection accuracy and image processing time according to the speed of the production line. To get the design data for the development of the inspection system used in the surface mount process, it is important to develop image analysis techniques based on X-ray image data. At the first step of our study, we attempt to detect the characteristics of the solder bridges based on the image analysis technique.


instrumentation and measurement technology conference | 2003

Development of image analysis for detection of defects of BGA by using X-ray images

Tetsuhiro Sumimoto; Toshinori Maruyama; Yoshiharu Azuma; Sachiko Goto; Munehiro Mondou; Noboru Furukawa; Saburo Okada

In the surface mount technology, Ball Grid Array (BGA) has been used in a production of PC boards, because of their excellent characters such as high density of the lead pin pitch, better lead rigidity and self-alignment during re-flow processing. This paper deals with the development of image analysis for the detection of defects at BGA solder joints in PC boards by using X-ray images. In the conventional IC boards, it is possible to detect defects of solder joints by visual inspection, because the lead of IC package is set on its outside. However, we cant detect visually defects at BGA solder joints, because they are hidden under the IC package. In a production line, the inspection of BGA in PC boards depends on the function test of electric circuits in the final process. To improve a cost performance and the reliability of PC boards, an inspection of BGA is required in the surface mount process. Types of defects at BGA solder joints are solder bridge, missing connection, solder voids, open connection and miss-registration of parts. As we can find mostly solder bridge in these defects, we pick up this to detect solder bridge in a production line. The problems of image analysis for the detection of defects at BGA solder joints are the detection accuracy and image processing time according to a line speed of production. To get design data for the development of the inspection system, which can be used easily in the surface mount process, it is important to develop image analysis techniques based on X-ray image data. At the first step of our study, we attempt to detect the characteristic of the solder bridges based on an image analysis.


Sixth International Symposium on Instrumentation and Control Technology: Signal Analysis, Measurement Theory, Photo-Electronic technology, and Artificial Intelligence | 2006

Analysis of BGA defects by tomographic images

Tetsuhiro Sumimoto; Toshinori Maruyama; Yoshiharu Azuma; Sachiko Goto; Munehiro Mondou; Noboru Furukawa; Saburo Okada

To improve the cost of performance in manufacturing IC packages, it is required to inspect BGA defects in the online process. The problems of image analysis for the detection of defects are the detection accuracy and image processing time according to a line speed of production. Using the X-ray penetration equipment, we have captured images of an IC package to search an abnormal BGA. To get design data for the development of the inspection system, which can be used easily in the surface mount process, we tried to capture the tomographic images utilizing the latest imaging techniques.


Fifth International Symposium on Instrumentation and Control Technology | 2003

Shape measurement of BGA for analysis of defects by X-ray imaging

Tetsuhiro Sumimoto; Toshinori Maruyama; Yoshiharu Azuma; Sachiko Goto; Munehiro Mondou; Noboru Furukawa; Saburo Okada

This paper deals with the development of image analysis for the detection of defects at BGA solder joints in PC boards by using X-ray imaging. We cant detect visually defects at BGA solder joints, because they are hidden under the IC package. To improve a cost performance and the reliability of PC boards, an inspection of BGA is required in the surface mount process. Types of defects at BGA solder joints are solder bridge, missing connection, solder voids, open connection and miss-registration of parts. As we can find mostly solder bridge in these defects, we pick up this to detect solder bridge in a production line. The problems of image analysis for the detection of defects at BGA solder joints are the detection accuracy and image processing time according to a line speed of production. To get design data for the development of the inspection system, which can be used easily in the surface mount process, it is important to develop image analysis techniques based on X-ray image data. At the first step of our study, we attempt to measure the shape of BGA based on X-ray imaging.


nuclear science symposium and medical imaging conference | 2012

Observation of activation brain areas in response to the stimulation by the right hand movement of Kawahira method using fMRI

Takahiko Yokote; Katsuhiro Kida; Satoshi Kuwahara; Takushi Kawashima; Tomoka Doi; Sachiko Goto; Yoshiharu Azuma

The purpose of this paper is to investigate the contribution of 3.0 T (tesla) functional magnetic resonance imaging (3T-fMRI) to analysis of effecti veness of various approaches to stroke rehabilitation. Using fMRI, we observed the activation of brain structures in response to stimulation to the right hand by Kwahira method that is intensive exercise therapy.


World Congress on Medical Physics and Biomedical Engineering: Diagnostic Imaging | 2009

The phantom for quality evaluations of the nonlinear noise reduction filter in multidetector row computed tomography

R. Matsuura; K. Fuji; Sachiko Goto; Yoshiharu Azuma; Keiji Inamura

In this paper we propose the phantom for quality evaluations of the nonlinear noise reduction filter in multidetector row computed tomography (MDCT). A nonlinear filter is a filter whose output is not proportional to its input (CT number or contrast value). Generally, a standard phantom for CT cannot be used for the quality evaluation of such a filter. The maximum feature of our phantom is being able to obtain edge spread functions of a maximum of six edge intensities under the influence of a certain maximum contrast by choosing a slice position...The edge-preserving adaptive filter for selectively eliminating noise in low-dose scanning known as the Quantum Denoising System (QDS) developed by Toshiba Medical Systems was chosen as a nonlinear noise reduction filter for this study. For evaluation of the filter characteristics, three types of evaluation, the noise statistical values (mean and standard deviation of CT numbers), noise characteristics (noise Wiener spectrum, WS) and resolution characteristics (modulation transfer function, MTF) were measured using the phantom. As a result, the statistics value of obtained noise, and WS and MTF were able to demonstrate the performance of the filter clearly. Further, our phantom was able to investigate the capability of edge-preserving adaptive filters such as QDS using MTFs with different edge intensities. As compared with a digital phantom, our actual phantom is considered to be a useful tool in order to know the overall processing results containing the feature of each CT scanner and reconstruction filter of manufacturing companies and the performance of a nonlinear noise reduction filter.


the World Congress on Medical Physics and Biomedical Engineering 2006(WC2006) | 2007

Increasing the sensitivity of the dosimetry system for high energy x-rays, using Gafchromic EBT film and a flat-bed scanner with sharp cut filters

Hirofumi Hato; Hideki Aoyama; Yoshiharu Azuma; Sachiko Goto; Tetsuhiro Sumimoto

To increase the sensitivity of the dosimetry system for high energy x-rays, using Gafchromic EBT film (International Specialty Products) and a flat-bed scanner with transparency unit (ES-2200 or Expression 1680, Epson, Inc.), the optimal sharp cut (SC) filters like optical filters to be added to the scanner were investigated. Gafchromic EBT film (EBT) has the absorption spectrum with a maximum absorption band centered at 636 nm. Consequently the response of EBT will be enhanced by measurement with red light and can be very significantly increased by using a red filter while making scanner measurements. In our research, employed SC filters were SC filter 54, 56, 58, 60 and 62 (product made from Fuji film). SC filters are defined as filters that cut off as much as possible of the wavelength light shorter than a specific wavelength, while transmitting as much of longer wavelength light as possible, within a wavelength range of 350 nm to 800 nm. Generally, it is ideal to use a narrow band pass filter. However we didn’t employ the filter because the transmissivity of the filter of film type is low or the thickness of glass type filter is large, so it is unsuitable for a flat-bed scanner. Film pieces of EBT were exposed to the following doses: 0.3 – 10.0 Gy with the 6 MV x-rays from a linear accelerator. The irradiated film pieces to which the SC filter was added were scanned and the scan data of red channel was converted into optical density. Furthermore the optical density was divided by the absorbed dose and the value was estimated as sensitivity. EBT with SC filter 62 with 50% of transmissivity at 620 nm was about 1.48 times more sensitive on the average than without a SC filter.


instrumentation and measurement technology conference | 2006

Measurement of Breast Density on Digital Mammograms

Sachiko Goto; Yoshiharu Azuma; Tetsuhiro Sumimoto; Yoshihiro Takeda; Naoko Tsujita; Shigefumi Kadohisa

We built a estimating system of individual breast density from digital mammograms by using breast tissue equivalent phantoms that are able to change the mixture ratio of adipose and glandular tissue and the thickness. The method was compared with a visual assessment of breast density by the radiologists as a gold standard. The clinical image data set that consisted of 49 mammograms of 21 patients were analyzed. The average of the estimated glandular rate was 35.0%, while varying from 12.0% to 67.0%. This system can apply in clinical practice such as the visual estimation of breast density


nuclear science symposium and medical imaging conference | 2012

Exploration of brain activations by passive hand movements and subject's intention based on Kawahira method using 3T-fMRI

Takushi Kawashima; Katsuhiro Kida; Satoshi Kuwahara; Takahiko Yokote; Tomoka Doi; Sachiko Goto; Yoshiharu Azuma

To investigate the contribution of 3.0 T functional magnetic resonance imaging (fMRI) to analysis of effectiveness of various approaches to stroke rehabilitation, we explored brain activations by passive hand movements and subjects intention based on the repetitive facilitation exercises (RFEs) shown by KKawahira.

Collaboration


Dive into the Yoshiharu Azuma's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Saburo Okada

National Institute of Advanced Industrial Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Noboru Furukawa

National Institute of Advanced Industrial Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge