Yoshinori Mizuguchi
Hamamatsu Photonics
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Yoshinori Mizuguchi.
Journal of Biomolecular Screening | 2002
Emmanuel Le Poul; Sunao Hisada; Yoshinori Mizuguchi; Vincent Dupriez; Emmanuel Burgeon; Michel Detheux
AequoScreen™, a cellular aequorin-based functional assay, has been optimized for luminescent high-throughput screening (HTS) of G protein-coupled receptor (GPCRs). AequoScreen is a homogeneous assay in which the cells are loaded with the apoaequorin cofactor coelenterazine, diluted in assay buffer, and injected into plates containing the samples to be tested. A flash of light is emitted following the calcium increase resulting from the activation of the GPCR by the sample. Here we have validated a new plate reader, the Hamamatsu Photonics FDSS6000, for HTS in 96- and 384-well plates with CHO-K1 cells stably coexpressing mitochondrial apoaequorin and different GPCRs (AequoScreen cell lines). The acquisition time, plate type, and cell number per well have been optimized to obtain concentration-response curves with 4000 cells/well in 384-well plates and a high signal: background ratio. The FDSS6000 and AequoScreen cell lines allow reading of twenty 96- or 384-well plates in 1 h with Z’ values of 0.71 and 0.78, respectively. These results bring new insights to functional assays, and therefore reinforce the interest in aequorin-based assays in a HTS environment.
Biomedical Optics Express | 2012
Norikazu Sugiyama; Yasuyuki Asai; Toyohiko Yamauchi; Takuji Kataoka; Takahiro Ikeda; Hidenao Iwai; Takashi Sakurai; Yoshinori Mizuguchi
There is a need for a noninvasive technique to monitor living pluripotent stem cell condition without any labeling. We present an optical imaging technique that is able to capture information about optical path difference through the cell and cell adhesion properties simultaneously using a combination of quantitative phase microscopy (QPM) and interference reflection microscopy (IRM) techniques. As a novel application of QPM and IRM, this multimodal imaging technique demonstrated its ability to distinguish the undifferentiated status of human induced pluripotent stem (hiPS) cells quantitatively based on the variation of optical path difference between the nucleus and cytoplasm as well as hiPS cell-specific cell adhesion properties.
Proceedings of SPIE | 2014
Toyohiko Yamauchi; Yumi Kakuno; Kentaro Goto; Tadashi Fukami; Norikazu Sugiyama; Hidenao Iwai; Yoshinori Mizuguchi; Yutaka Yamashita
There is an increasing need for non-invasive imaging techniques in the field of stem cell research. Label-free techniques are the best choice for assessment of stem cells because the cells remain intact after imaging and can be used for further studies such as differentiation induction. To develop a high-resolution label-free imaging system, we have been working on a low-coherence quantitative phase microscope (LC-QPM). LC-QPM is a Linnik-type interference microscope equipped with nanometer-resolution optical-path-length control and capable of obtaining three-dimensional volumetric images. The lateral and vertical resolutions of our system are respectively 0.5 and 0.93 μm and this performance allows capturing sub-cellular morphological features of live cells without labeling. Utilizing LC-QPM, we reported on three-dimensional imaging of membrane fluctuations, dynamics of filopodia, and motions of intracellular organelles. In this presentation, we report three-dimensional morphological imaging of human induced pluripotent stem cells (hiPS cells). Two groups of monolayer hiPS cell cultures were prepared so that one group was cultured in a suitable culture medium that kept the cells undifferentiated, and the other group was cultured in a medium supplemented with retinoic acid, which forces the stem cells to differentiate. The volumetric images of the 2 groups show distinctive differences, especially in surface roughness. We believe that our LC-QPM system will prove useful in assessing many other stem cell conditions.
Archive | 1992
Kiyoshi Kamiya; Shigeru Uchiyama; Hideshi Ohishi; Norikazu Sugiyama; Yoshinori Mizuguchi; Masahiko Hirano
Archive | 1999
Yoshinori Mizuguchi; 義則 水口
Archive | 1998
Yoshinori Mizuguchi; Yoshitaka Ohashi; 祥高 大橋; 義則 水口
Archive | 1990
Shigeru Uchiyama; Hideji Fujiwake; Iwayo Nakagawa; Masahiko Hirano; Yoshinori Mizuguchi; Hideshi Oishi; Norikazu Sugiyama
Archive | 1998
Takuji Kataoka; Masanori Matsubara; Yoshinori Mizuguchi; 正典 松原; 義則 水口; 卓治 片岡
Archive | 2000
Norifumi Tomita; Yoshio Isobe; Hirotoshi Terada; Yoshinori Mizuguchi
Archive | 2001
Takuji Kataoka; Yoshinori Mizuguchi; 義則 水口; 卓治 片岡