Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yoshio Onishi is active.

Publication


Featured researches published by Yoshio Onishi.


Journal of Bone and Joint Surgery-british Volume | 2013

Mid-flexion laxity is greater after posterior-stabilised total knee replacement than with cruciate-retaining procedures

Kazunori Hino; Masami Ishimaru; Yasutake Iseki; Seiji Watanabe; Yoshio Onishi; Hiromasa Miura

There are several methods for evaluating stability of the joint during total knee replacement (TKR). Activities of daily living demand mechanical loading to the knee joint, not only in full extension, but also in mid-flexion. The purpose of this study was to compare the varus-valgus stability throughout flexion in knees treated with either cruciate-retaining or posterior-stabilised TKR, using an intra-operative navigation technique. A total of 34 knees underwent TKR with computer navigation, during which the investigator applied a maximum varus-valgus stress to the knee while steadily moving the leg from full extension to flexion both before and after prosthetic implantation. The femorotibial angle was measured simultaneously by the navigation system at every 10° throughout the range of movement. It was found that posterior-stabilised knees had more varus-valgus laxity than cruciate-retaining knees at all angles examined, and the differences were statistically significant at 10° (p = 0.0093), 20° (p = 0.0098) and 30° of flexion (p = 0.0252).


Journal of Orthopaedic Research | 2014

Three‐dimensional motion analysis of the patellar component in total knee arthroplasty by the image matching method using image correlations

Masami Ishimaru; Yoshitaka Shiraishi; Satoru Ikebe; Hidehiko Higaki; Kazunori Hino; Yoshio Onishi; Hiromasa Miura

In total knee arthroplasty (TKA), the patella is significantly associated with range of motion and gait performance. Currently, no highly accurate methods are available that can measure the 3D in vivo behavior of the TKA patellar component, as the component is made of x‐ray‐permeable ultra‐high molecular weight polyethylene. Previously, we developed a computer simulation that matches CT scan and unidirectional radiographic images using image correlations, and applied it to kinematic studies of natural and TKA knees. The examination of the measurement accuracy for the patellar bone of a fresh‐frozen pig knee joint yielded a root mean square error of 0.2 mm in translation and 0.2° in rotation. In this study, we recruited four patients who had a TKA and investigated 3D movements of the patellar component during squatting. We could visualize the patellar component using the position of the holes drilled for the component peg, and estimated and visualized the contact points between the patellar and femoral components. The principles and the utility of the simulation method are reported. This analytical method is useful for evaluating the pathologies and post‐surgical conditions of the knee and other joints.


Knee | 2014

A three-dimensional computed tomography study of distal femoral morphology in Japanese patients: Gender differences and component fit

Masami Ishimaru; Kazunori Hino; Yoshio Onishi; Yasutake Iseki; Naohiko Mashima; Hiromasa Miura

BACKGROUND Previous anthropometric studies have reported gender differences in distal femoral morphology. However, to date, very few studies have investigated the knee morphology of Japanese adults and possible gender differences. The purpose of this study was to examine the distal femoral morphology of Japanese patients, to characterize anatomical differences between male and female, and to evaluate the need to create gender-specific knee prostheses. MATERIAL AND METHODS We evaluated 80 knees in 40 male and 40 female Japanese patients scheduled for total knee arthroplasty (TKA). The mediolateral (ML) and anteroposterior (AP) dimensions of the knees at different levels were measured preoperatively using three-dimensional computed tomography, and ML/AP aspect ratios were calculated. RESULTS On the distal femoral cut surface, the mean ML widths were 74.9 mm for male and 65.1mm for female, and the mean AP lengths were 63.4mm for male and 58.9 mm for female. Such values were generally smaller compared to data from European and North American studies. In this study, the mean ML/AP aspect ratios were 1.31 for male and 1.25 for female, higher than those from non-Asian regions. The ML/AP ratios of Japanese patients were negatively correlated with distal femoral AP length. CONCLUSIONS Japanese female had a relatively narrower femoral width for a given AP length than male. Our study suggests the utility of Japanese-specific implants and provides useful insights for manufacturers to design components of appropriate sizes and aspect ratios for Japanese TKA patients.


Journal of Orthopaedic Science | 2016

The influence of tibial resection on the PCL in PCL-retaining total knee arthroplasty: A clinical and cadaveric study

Yoshio Onishi; Kazunori Hino; Seiji Watanabe; Kunihiko Watamori; Tatsuhiko Kutsuna; Hiromasa Miura


Journal of Bone and Joint Surgery-british Volume | 2016

THE PRE-OPERATIVE VARUS–VALGUS KINEMATIC PATTERN THROUGHOUT FLEXION PERSISTED MORE STRONGLY AFTER CR-TKA COMPARED WITH PS-TKA

Kazunori Hino; Yoshio Onishi; Tatsuhiko Kutsuna; Kunihiko Watamori; Hiroshi Kiyomatsu; Hiromasa Miura


Journal of Bone and Joint Surgery-british Volume | 2016

SHORT-TERM RESULTS OF TOTAL KNEE ARTHROPLASTY WITH MERA QUEST KNEE SYSTEM

Yoshio Onishi; Masami Ishimaru; Kazunori Hino; Yoshitaka Shiraishi; Hiromasa Miura


Journal of Bone and Joint Surgery-british Volume | 2016

GENDER DIFFERENCES OF DISTAL FEMORAL MORPHOLOGY IN JAPANESE PATIENTS

Kunihiko Watamori; Masami Ishimaru; Yoshio Onishi; Kazunori Hino; Hiromasa Miura


Journal of Bone and Joint Surgery-british Volume | 2016

INFLUENCE OF PRE-OPERATIVE ALIGNMENT ON POST-OPERATIVE VARUS-VALGUS JOINT LAXITY IN TOTAL KNEE ARTHROPRASTY

Hiroshi Kiyomatsu; Kazunori Hino; Tatsuhiko Kutsuna; Kunihiko Watamori; Yoshio Onishi; Hiromasa Miura


Journal of Bone and Joint Surgery-british Volume | 2016

ROTATIONAL KINEMATIC ANALYSIS OF A CRUCIATE-RETAINING AND POSTERIOR-STABILISED TOTAL KNEE ARTHROPLASTY USING COMPUTER NAVIGATION SYSTEM

Tatsuhiko Kutsuna; Kazunori Hino; Yoshio Onishi; Kunihiko Watamori; Hiromasa Miura


The Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics 2015.8 | 2015

PS5-3 Length Patterns in the Posterior Cruciate Ligament of the Natural Knee Joints using Image Matching Method(PS5: Poster Short Presentation V,Poster Session)

Yoshitaka Shiraishi; Kazunori Hino; Kazuho Nishimatsu; Yoshio Onishi; Tatsuhiko Kutsuna; Kunihiko Watamori; Hiromasa Miura; Satoru Ikebe; Hidehiko Higaki; Yoshitaka Nakanishi

Collaboration


Dive into the Yoshio Onishi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Satoru Ikebe

Kyushu Sangyo University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge