Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yukinobu Takimoto is active.

Publication


Featured researches published by Yukinobu Takimoto.


Brain Research | 1996

NERVE REGENERATION ACROSS A 25-MM GAP BRIDGED BY A POLYGLYCOLIC ACID-COLLAGEN TUBE: A HISTOLOGICAL AND ELECTROPHYSIOLOGICAL EVALUATION OF REGENERATED NERVES

Tetsuya Kiyotani; Masayoshi Teramachi; Yukinobu Takimoto; Tatsuo Nakamura; Yasuhiko Shimizu; Katsuaki Endo

In the study reported here we have examined the nerve regeneration that occurs over a 25-mm gap using a novel biodegradable nerve guide tube. The tube was a composite of polyglycolic acid (PGA) mesh coated with collagen which was filled with neurotrophic factors. The left sciatic nerve of ten adult cats was dissected. The stumps were connected by the tube, and fixed gap. Histological examinations carried out 4-16 months after implantation of the tube revealed regeneration of well vascularized nerve tissue. Regeneration of both myelinated, unmyelinated axons and Schwann cells was confirmed by electron microscopy 5 months after surgery. Following injection of horseradish peroxidase (HRP) into a site peripheral to the regenerated segment of the sciatic nerves, motoneurons in the ventral horn of the spinal cord, afferent terminals in the medial portion of the dorsal column of the medulla oblongata, and sensory afferent nerve terminals in the dorsal horn of the spinal cord were labelled. Electrophysiological examinations revealed restoration of evoked electromyograms and sensory evoked potentials (SEPs) recorded from the cerebral cortex as well as the spinal cord. We also found that some of the regenerated motor axons exhibited branching in the regenerated segments. In two cases, a single motoneuronal axon from the regenerated side projected to both flexors and extensors, simultaneously. Our results indicate that the PGA-collagen composite tube is a promising tool for use as a nerve guide tube in peripheral nerve regeneration.


The Journal of Thoracic and Cardiovascular Surgery | 1998

The experimental replacement of a cervical esophageal segment with an artificial prosthesis with the use of collagen matrix and a silicone stent

Yukinobu Takimoto; Tatsuo Nakamura; Yasumichi Yamamoto; Tetsuya Kiyotani; Masayoshi Teramachi; Yasuhiko Shimizu

OBJECTIVE Attempts have been made to replace esophageal defects with a variety of artificial materials. However, because of the artificial nature of the materials, problems such as infection, leakage, stricture, or dislocation could not be avoided. Therefore we have designed a new type of artificial esophagus that is gradually replaced by host tissue. METHODS Our artificial esophagus was a two-layered tube consisting of a collagen sponge matrix and an inner silicone stent. We used it to replace 5 cm esophageal segmental defects in 43 dogs, and the inner silicone stent was removed endoscopically at weekly intervals from 2 to 4 weeks. RESULTS In the 27 dogs from which the silicone stent was removed at 2 or 3 weeks, constriction of the regenerated esophagus progressed and the dogs became unable to swallow within 6 months. In the 16 dogs from which the silicone stent was removed at 4 weeks, highly regenerated esophageal tissue successfully replaced the defect, leaving no foreign body in the host. Moreover, the regenerated esophagi had stratified flattened epithelia, striated muscle tissue composed of an inner circular and an outer longitudinal muscle layer, and esophageal glands. CONCLUSIONS Even in mature adult higher mammals, esophageal high-order structures can be regenerated provided that an adequate three-dimensional extracellular structure is put in place for a sufficient period.


The Journal of Thoracic and Cardiovascular Surgery | 1999

Intrathoracic esophageal replacement in the dog with the use of an artificial esophagus composed of a collagen sponge with a double-layered silicone tube

Yasumichi Yamamoto; Tatsuo Nakamura; Yasuhiko Shimizu; Kazuya Matsumoto; Yukinobu Takimoto; Tetsuya Kiyotani; Takashi Sekine; Hiroki Ueda; Yu Liu; Nobushige Tamura

OBJECTIVES Intrathoracic esophageal replacement with an artificial esophagus is considered difficult. We attempted to replace the intrathoracic esophagus with an artificial esophagus composed of a collagen sponge with a double-layered silicone tube and examined the state of host tissue regeneration. METHODS A 5-cm long gap was created in the intrathoracic esophagus in 9 dogs and repaired by interposition of our prosthesis. The dogs were fed only by intravenous hyperalimentation for 28 days. The silicone tube was removed at 29 days after the operation, and oral feeding was reintroduced. RESULTS One dog was put to death at each of the following times: 1, 2, 3, 3, 6, 12, and 24 months after the operation. One dog is still surviving without problems after more than 26 months. One dog died of malnutrition at 10 months. In all dogs, the host regenerated tissue had replaced the resulting gap at the time of silicone tube removal. The mucosa had fully regenerated within 3 months and the glands within 12 months. The process of stenosis and shrinkage was complete within 3 months and did not advance thereafter. The lamina muscularis mucosae were observed as islets of smooth muscle within 12 months. Although the skeletal muscle regenerated close to the anastomoses, it did not extend to the middle of the regenerated esophagus even after 24 months. CONCLUSIONS Use of a collagen sponge with a double-layered silicone tube was shown to be feasible even in the thorax and to allow the regenerated host tissue, consisting of the mucosa, glands, and lamina muscularis mucosae, to replace the esophageal gap.


The Annals of Thoracic Surgery | 1997

Porous-Type Tracheal Prosthesis Sealed With Collagen Sponge

Masayoshi Teramachi; Tatsuo Nakamura; Yasumichi Yamamoto; Tetsuya Kiyotani; Yukinobu Takimoto; Yasuhiko Shimizu

BACKGROUND Reconstruction of a long section of the trachea is clinically problematic. Tracheal reconstructions using prostheses have met with limited success due to local infection, hemorrhage, luminal stenosis and prosthesis dislocation. METHODS We have designed a porous type of tracheal prosthesis in which the mesh is sealed with collagen sponge. We used this prosthesis (50 mm in length) to reconstruct the cervical trachea in 10 mongrel dogs and evaluated its efficacy. RESULTS One dog died due to an accident with anesthesia at 6 weeks and 1 of suffocation at 10 weeks. The other 8 dogs had an uneventful postoperative course until they were killed between 6 and 24 months after implantation. At sacrifice, all the prostheses had become completely incorporated into the host. Microscopic examination revealed advanced formation of a new epithelial lining in 1 dog at 6 months, and a confluent epithelial lining was observed in another dog at 12 months. Central stenosis was not significant in any of the animals. CONCLUSIONS This tracheal prosthesis gives good results in canine tracheal reconstruction, and appears very promising for the clinical repair of tracheal defects.


The Journal of Thoracic and Cardiovascular Surgery | 1997

Intrathoracic tracheal reconstruction with a collagen-conjugated prosthesis: Evaluation of the efficacy of omental wrapping

Masayoshi Teramachi; Norihito Okumura; Tatsuo Nakamura; Yasumichi Yamamoto; Tetsuya Kiyotani; Yukinobu Takimoto; Shojiro Matsuda; Yoshito Ikada; Yasuhiko Shimizu

Reconstructions of the intrathoracic trachea in 24 dogs were done with the use of 50 mm long collagen-conjugated tracheal prostheses. Omental wrapping was also done in 14 of the dogs (omentopexy group) to evaluate the efficacy of this option in comparison with results in the other 10 dogs (control group). All 24 dogs had uneventful postoperative courses and were killed at 4 weeks or 3, 6, or 12 months after the operation. Better epithelialization and fewer complications, such as mesh exposure and luminal stenosis, were observed in the omentopexy group than in the control group. Angiography and analysis of regenerated blood vessels revealed that vessel ingrowth had started within 4 weeks and that vessel formation reached its maximal point within 6 to 12 months in the omentopexy group. In contrast, revascularization of the subepithelial region in the control group was poor even after 3 months, and vessel formation continued for as long as 12 months. The differences between the two groups were considered to be mainly a result of the speed of blood vessel ingrowth into the regenerated mucosa. We conclude that our prosthesis can be used safely for intrathoracic tracheal reconstruction and that omental wrapping is a useful supplementary method that reduces the occurrence of complications.


Journal of Biomedical Materials Research | 2001

A new type of surgical adhesive made from porcine collagen and polyglutamic acid

Takashi Sekine; Tatsuo Nakamura; Yasuhiko Shimizu; Hiroki Ueda; Kazuya Matsumoto; Yukinobu Takimoto; Tetsuya Kiyotani

We have developed a new adhesive for surgical use. The new adhesive is made of three components: porcine collagen, poly(L-glutamic acid) and water-soluble carbodiimides (WSC). The optimum concentration of each component was determined by measuring the time required for gel formation in experiments in vitro. Using these optimum concentrations, we applied the adhesive to wounds made on rats. A conventional fibrin glue was used as a control. Measurement of tensile strength and histological examination were performed 5, 7, 10, and 14 days after the operation. The tensile strength of wounds treated with 2.5 mg/mL collagen glue was not significantly different from that of wounds treated with fibrin glue except at 7 days after the operation (p < 0.05 by Students t-test). Histological examination revealed that the speed of cell infiltration into, and absorption of 2.5 mg/mL collagen glue was slower than for fibrin glue, but faster than for 5.0 mg/mL collagen glue. One of the important advantages of our collagen glue is that the absorption rate of it can be controlled by the collagen concentration. Therefore, it seems to be adequate for sealing air leakage from the lung, which takes a relatively long period for recovery. Moreover it does not contain human serum, and, hence, it requires no blood donation and can be obtained with low cost.


Asaio Journal | 2000

Intrathoracic esophageal replacement with a collagen sponge-silicone double layer tube : Evaluation of omental-pedicle wrapping and prolonged placement of an inner stent

Yasumichi Yamamoto; Tatsuo Nakamura; Yasuhiko Shimizu; Kazuya Matsumoto; Yukinobu Takimoto; Yu Liu; Hiroki Ueda; Takashi Sekine; Nobushige Tamura

In a previous study, we replaced a 5 cm gap created in the canine intrathoracic esophagus with an artificial esophagus. However, although newly formed esophageal tissue subsequently bridged the gap, mild stenosis occurred, and this seemed to be caused by inadequate regeneration of the skeletal muscle. In the present study, we evaluated whether omental pedicle wrapping (OMPx) of the prosthesis could promote tissue regeneration and whether prolonged retention of the silicone tube within the prosthesis could prevent stenosis. A gap was created in 14 dogs, and the defect was repaired by our prosthesis. OMPx was performed in 5 of the 14 dogs (OMPx group) but not in the rest (control group). The silicone tube was retained for 4 weeks in the control group and for 8 weeks in the OMPx group. All of the dogs in the control group survived for more than 3 months, except for those that were killed. Four dogs in the OMPx group died within 3 months, one caused by perforation at 7 months. Only the thin epithelial and submucosal layer regenerated in the OMPx group. OMPx is not effective for promoting tissue regeneration, and prolonged retention of the silicone tube interrupts epithelial regeneration.


Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery | 1999

FACIAL NERVE REPAIR USING A COLLAGEN CONDUIT IN CATS

Américo Kiyoshi Kitahara; Yoshihisa Suzuki; Peng Qi; Yoshihiko Nishimura; Kyoko Suzuki; Tetsuya Kiyotani; Yukinobu Takimoto; Tatsuo Nakamura; Yasuhiko Shimizu; Katsuaki Endo

We evaluated facial nerve regeneration using a collagen tube as a nerve conduit in five cats. In three 5 mm of the facial nerve were resected, a collagen tube was implanted, and a 5 mm segment of the opposite facial nerve was resected, reversed 180 degrees, and sutured back as an autologous nerve graft. In one a collagen tube was implanted on one side, and in the remaining one a 5 mm nerve segment was reversed. Histological, electrophysiological, and horseradish peroxidase labelling examinations were carried out 4-24 weeks postoperatively. Histological study showed that the nerve was well vascularised and regenerated. Electrophysiological examination confirmed the recovery of evoked electromyograms through to the regenerated axons. Horseradish peroxidase examination also confirmed restoration of the whole facial nerve. The collagen tube is an efficient nerve conduit.


Asaio Journal | 1993

Long-term follow-up of the experimental replacement of the esophagus with a collagen-silicone composite tube

Yukinobu Takimoto; Norihito Okumura; Tatsuo Nakamura; Tohru Natsume; Yasuhiko Shimizu

This study investigated ways of preventing late stenosis after replacing the esophagus with a prosthetic device and increasing survival time in an animal model. In a previous study, the authors induced neoesophageal formation and re-epithelialization at an early stage, although stenosis in the chronic stage remained a problem, and long-term survival was prevented. The authors developed an artificial esophagus made from a collagen-silicone composite tube. The silicone tube (25 mm in diameter, 50 mm long, and 1 mm thick) was covered with collagen sponge (5 mm thick). The collagen sponge was intended to be replaced by host tissue, leading to neoesophageal regeneration. The authors thought stenosis was caused primarily by poor regeneration of submucosal tissue, rather than reepithelialization. Thus, they examined the grade of stenosis relative to the time the stent became dislodged. They concluded that the occurrence of stenosis after anastomosis depends upon the duration of stenting and that stenosis did not develop when the portion replaced by the artificial esophagus was stented for at least 4 weeks.


Asaio Journal | 1995

Replacement of Long Segments of the Esophagus With a Collagen–Silicone Composite Tube

Yukinobu Takimoto; Tatsuo Nakamura; Masayoshi Teramachi; Tetsuya Kiyotani; Yasuhiko Shimizu

Artificial esophagi designed thus far can be classified into three types in terms of the materials used: natural, artificial, and composite. In conventional models, even when artificial esophagi were made of ideal materials with high tissue affinity, they remained in the tissue as a foreign body, and therefore were not free of the complications caused by implanted material. The authors have designed a new type of artificial esophagus composed of a Silicone tube covered with nonantigenic collagen. The novel feature of this artificial esophagus is that the prosthesis does not remain in the implanted site, but is replaced by regenerated host tissue. Using this artificial esophagus, the authors have already succeeded in replacing a 5 cm gap in the esophagus. In this study, replacement of longer portions of the esophagus was assessed in seven dogs using a 10 cm long artificial esophagus. Stenosis did not occur in five of the seven dogs and, consequently, these dogs survived by oral feeding alone for more than 6 months without dry weight loss. The other two animals died of anesthetic accidents at the time of stent removal 6 weeks after surgery. In both cases, the internal surface of the neoesophagus was covered with a polylayer of squamous epithelium. Regenerated esophagi had normal esophageal glands and immature muscle tissue. It is therefore concluded that this new artificial esophagus is also applicable for replacement of long segments of esophagus.

Collaboration


Dive into the Yukinobu Takimoto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge