Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yuxue Liang is active.

Publication


Featured researches published by Yuxue Liang.


Rapid Communications in Mass Spectrometry | 2010

Electrospray tandem quadrupole fragmentation of quinolone drugs and related ions. On the reversibility of water loss from protonated molecules.

P. Neta; Bhaskar Godugu; Yuxue Liang; Yamil Simón-Manso; Xiaoyu Yang; Stephen E. Stein

Selected reaction monitoring (SRM) of quinolone drugs showed different sensitivities in aqueous solution vs. biological extract. The authors suggested formation of two singly protonated molecules with different behavior, one undergoing loss of H(2)O and the other loss of CO(2), so that SRM transitions might depend on the ratios of these forms generated by the electrospray. These surprising results prompted us to re-examine several quinolone drugs and some simpler compounds to further elucidate the mechanisms. We find that the relative contributions of loss of H(2)O vs. loss of CO(2) in tandem mass spectrometric (MS/MS) experiments depend not only on molecular structure and collision energy, but also, in certain cases, on the cone voltage. We further find that many product ions formed by loss of H(2)O can reattach a water molecule in the collision cell, whereas ions formed by loss of CO(2) do not. Since reattachment of H(2)O can occur after water loss in the cone region and prior to selection of the precursor ion, this effect leads to the dependence of MS/MS spectra on the cone voltage used in creating the precursor ion, which explains the formerly observed effect on SRM ratios. Our results support the earlier conclusion that varying amounts of two ions of the same m/z value are responsible for problems in the analysis of these drugs, but the origin is in dehydration/rehydration reactions. Thus, SRM transitions for certain complex compounds may be comparable only when monitored under equivalent ion-forming conditions, including the voltage used in the production of the protonated molecules in the electrospray ionization (ESI) source.


Rapid Communications in Mass Spectrometry | 2014

Unexpected peaks in tandem mass spectra due to reaction of product ions with residual water in mass spectrometer collision cells

P. Neta; Mahnaz Farahani; Yamil Simón-Manso; Yuxue Liang; Xiaoyu Yang; Stephen E. Stein

RATIONALE Certain product ions in electrospray ionization tandem mass spectrometry are found to react with residual water in the collision cell. This reaction often leads to the formation of ions that cannot be formed directly from the precursor ions, and this complicates the mass spectra and may distort MRM (multiple reaction monitoring) results. METHODS Various drugs, pesticides, metabolites, and other compounds were dissolved in acetonitrile/water/formic acid and studied by electrospray ionization mass spectrometry to record their MS(2) and MS(n) spectra in several mass spectrometers (QqQ, QTOF, IT, and Orbitrap HCD). Certain product ions were found to react with residual water in collision cells. The reaction was confirmed by MS(n) studies and the rate of reaction was determined in the IT instrument using zero collision energy and variable activation times. RESULTS Examples of product ions reacting with water include phenyl and certain substituted phenyl cations, benzoyl-type cations formed from protonated folic acid and similar compounds by loss of the glutamate moiety, product ions formed from protonated cyclic siloxanes by loss of methane, product ions formed from organic phosphates, and certain negative ions. The reactions of product ions with residual water varied greatly in their rate constant and in the extent of reaction (due to isomerization). CONCLUSIONS Various types of product ions react with residual water in mass spectrometer collision cells. As a result, tandem mass spectra may contain unexplained peaks and MRM results may be distorted by the occurrence of such reactions. These often unavoidable reactions must be taken into account when annotating peaks in tandem mass spectra and when interpreting MRM results. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.


Rapid Communications in Mass Spectrometry | 2014

Loss of H2 and CO from protonated aldehydes in electrospray ionization mass spectrometry

P. Neta; Yamil Simón-Manso; Yuxue Liang; Stephen E. Stein

RATIONALE Electrospray ionization mass spectrometry (ESI-MS) of many protonated aldehydes shows loss of CO as a major fragmentation pathway. However, we find that certain aldehydes undergo loss of H2 followed by reaction with water in the collision cell. This complicates interpretation of tandem mass (MS/MS) spectra and affects multiple reaction monitoring (MRM) results. METHODS 3-Formylchromone and other aldehydes were dissolved in acetonitrile/water/formic acid and studied by ESI-MS to record their MS(2) and MS(n) spectra in several mass spectrometers (QqQ, QTOF, ion trap (IT), and Orbitrap HCD). Certain product ions were found to react with water and the rate of reaction was determined in the IT instrument using zero collision energy and variable activation times. Theoretical calculations were performed to help with the interpretation of the fragmentation mechanism. RESULTS Protonated 3-formylchromones and 3-formylcoumarins undergo loss of H2 as a major fragmentation route to yield a ketene cation, which reacts with water to form a protonated carboxylic acid. In general, protonated aldehydes which contain a vicinal group that forms a hydrogen bridge with the formyl group undergo significant loss of H2. Subsequent losses of CO and C3O are also observed. Theoretical calculations suggest mechanistic details for these losses. CONCLUSIONS Loss of H2 is a major fragmentation channel for protonated 3-formychromones and certain other aldehydes and it is followed by reaction with water to produce a protonated carboxylic acid, which undergoes subsequent fragmentation. This presents a problem for reference libraries and raises concerns about MRM results.


Molecular & Cellular Proteomics | 2014

Tandem Mass Spectral Libraries of Peptides in Digests of Individual Proteins: Human Serum Albumin (HSA)

Qian Dong; Xinjian Yan; Lisa E. Kilpatrick; Yuxue Liang; Yuri A. Mirokhin; Jeri Roth; Paul A. Rudnick; Stephen E. Stein

This work presents a method for creating a mass spectral library containing tandem spectra of identifiable peptide ions in the tryptic digestion of a single protein. Human serum albumin (HSA1) was selected for this purpose owing to its ubiquity, high level of characterization and availability of digest data. The underlying experimental data consisted of ∼3000 one-dimensional LC-ESI-MS/MS runs with ion-trap fragmentation. In order to generate a wide range of peptides, studies covered a broad set of instrument and digestion conditions using multiple sources of HSA and trypsin. Computer methods were developed to enable the reliable identification and reference spectrum extraction of all peptide ions identifiable by current sequence search methods. This process made use of both MS2 (tandem) spectra and MS1 (electrospray) data. Identified spectra were generated for 2918 different peptide ions, using a variety of manually-validated filters to ensure spectrum quality and identification reliability. The resulting library was composed of 10% conventional tryptic and 29% semitryptic peptide ions, along with 42% tryptic peptide ions with known or unknown modifications, which included both analytical artifacts and post-translational modifications (PTMs) present in the original HSA. The remaining 19% contained unexpected missed-cleavages or were under/over alkylated. The methods described can be extended to create equivalent spectral libraries for any target protein. Such libraries have a number of applications in addition to their known advantages of speed and sensitivity, including the ready re-identification of known PTMs, rejection of artifact spectra and a means of assessing sample and digestion quality.


Rapid Communications in Mass Spectrometry | 2015

Reaction of arylium ions with the collision gas N2 in electrospray ionization mass spectrometry

Yuxue Liang; P. Neta; Yamil Simón-Manso; Stephen E. Stein

RATIONALE The tandem mass spectra of many compounds contained peaks which could not have arisen from the precursor ion. Such peaks were found to be due to reaction of arylium ions with N2 in the collision cell. Therefore, this reaction was studied in detail with representative compounds. METHODS Various classes of compounds were dissolved in acetonitrile/water/formic acid and studied by electrospray ionization mass spectrometry to record their MS(2) and pseudo-MS(3) spectra in a QqQ mass spectrometer and their accurate m/z values in an Orbitrap Elite instrument. Arylium ions were found to react with N2 in the collision cell. The reaction was confirmed by pseudo-MS(3) studies, by comparison with authentic diazonium ions, and by the pressure dependence of the product ion survival yield. RESULTS Reactions of arylium ions with N2 were observed with p-toluenesulfonic acid, o-toluenesulfonamide, phenylphosphonic acid, phenol, aniline, aminonaphthalenes, benzoic acid, benzophenone, and other compounds. By using a QqQ mass spectrometer, we observed that the protonated compounds produce arylium ions, which then react with N2 to form diazonium ions. The diazonium ion was produced with N2 but not with Ar in the collision cell, and its abundance increased with increasing N2 pressure. CONCLUSIONS Arylium ions generated from a wide variety of compounds in electrospray ionization tandem mass spectrometry may react with N2 to form diazonium ions. The abundance of the diazonium ions is affected by collision energy and N2 pressure. This reaction should be considered when annotating peaks in MS/MS libraries. Published in 2015. This article is a U.S. Government work and is in the public domain in the USA.


mAbs | 2018

The NISTmAb tryptic peptide spectral library for monoclonal antibody characterization

Qian Dong; Yuxue Liang; Xinjian Yan; Sanford P. Markey; Yuri A. Mirokhin; Dmitrii V. Tchekhovskoi; Tallat H. Bukhari; Stephen E. Stein

ABSTRACT We describe the creation of a mass spectral library composed of all identifiable spectra derived from the tryptic digest of the NISTmAb IgG1κ. The library is a unique reference spectral collection developed from over six million peptide-spectrum matches acquired by liquid chromatography-mass spectrometry (LC-MS) over a wide range of collision energy. Conventional one-dimensional (1D) LC-MS was used for various digestion conditions and 20- and 24-fraction two-dimensional (2D) LC-MS studies permitted in-depth analyses of single digests. Computer methods were developed for automated analysis of LC-MS isotopic clusters to determine the attributes for all ions detected in the 1D and 2D studies. The library contains a selection of over 12,600 high-quality tandem spectra of more than 3,300 peptide ions identified and validated by accurate mass, differential elution pattern, and expected peptide classes in peptide map experiments. These include a variety of biologically modified peptide spectra involving glycosylated, oxidized, deamidated, glycated, and N/C-terminal modified peptides, as well as artifacts. A complete glycation profile was obtained for the NISTmAb with spectra for 58% and 100% of all possible glycation sites in the heavy and light chains, respectively. The site-specific quantification of methionine oxidation in the protein is described. The utility of this reference library is demonstrated by the analysis of a commercial monoclonal antibody (adalimumab, Humira®), where 691 peptide ion spectra are identifiable in the constant regions, accounting for 60% coverage for both heavy and light chains. The NIST reference library platform may be used as a tool for facile identification of the primary sequence and post-translational modifications, as well as the recognition of LC-MS method-induced artifacts for human and recombinant IgG antibodies. Its development also provides a general method for creating comprehensive peptide libraries of individual proteins.


Journal of the American Society for Mass Spectrometry | 2018

Collision-Induced Dissociation of Deprotonated Peptides. Relative Abundance of Side-Chain Neutral Losses, Residue-Specific Product Ions, and Comparison with Protonated Peptides

Yuxue Liang; P. Neta; Xiaoyu Yang; Stephen E. Stein

AbstractHigh-accuracy MS/MS spectra of deprotonated ions of 390 dipeptides and 137 peptides with three to six residues are studied. Many amino acid residues undergo neutral losses from their side chains. The most abundant is the loss of acetaldehyde from threonine. The abundance of losses from the side chains of other amino acids is estimated relative to that of threonine. While some amino acids lose the whole side chain, others lose only part of it, and some exhibit two or more different losses. Side-chain neutral losses are less abundant in the spectra of protonated peptides, being significant mainly for methionine and arginine. In addition to the neutral losses, many amino acid residues in deprotonated peptides produce specific negative ions after peptide bond cleavage. An expanded list of fragment ions from protonated peptides is also presented and compared with those of deprotonated peptides. Fragment ions are mostly different for these two cases. These lists of fragments are used to annotate peptide mass spectral libraries and to aid in the confirmation of specific amino acids in peptides. Graphical Abstractᅟ


Analytical Chemistry | 2013

Metabolite Profiling of a NIST Standard Reference Material for Human Plasma (SRM 1950) GC/MS, LC/MS, NMR and Clinical Laboratory Analyses, Libraries and Web-based resources

Yamil Simón-Manso; Mark S. Lowenthal; Lisa E. Kilpatrick; Maureen Sampson; Kelly H. Telu; Paul A. Rudnick; W. Gary Mallard; Daniel W. Bearden; Tracey B. Schock; Dmitrii V. Tchekhovskoi; Nikša Blonder; Xinjian Yan; Yuxue Liang; Yufang Zheng; William E. Wallace; P. Neta; Karen W. Phinney; Alan T. Remaley; Stephen E. Stein


Analytical Chemistry | 2014

Quantitative Bottom-Up Proteomics Depends on Digestion Conditions

Mark S. Lowenthal; Yuxue Liang; Karen W. Phinney; Stephen E. Stein


Journal of Proteome Research | 2013

Comprehensive analysis of protein digestion using six trypsins reveals the origin of trypsin as a significant source of variability in proteomics

Scott Walmsley; Paul A. Rudnick; Yuxue Liang; Qian Dong; Stephen E. Stein; Alexey I. Nesvizhskii

Collaboration


Dive into the Yuxue Liang's collaboration.

Top Co-Authors

Avatar

Stephen E. Stein

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

P. Neta

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Yamil Simón-Manso

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Qian Dong

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Xiaoyu Yang

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Xinjian Yan

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Lisa E. Kilpatrick

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Paul A. Rudnick

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Dmitrii V. Tchekhovskoi

National Institute of Standards and Technology

View shared research outputs
Top Co-Authors

Avatar

Karen W. Phinney

National Institute of Standards and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge