Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Yuzo Yamasaki is active.

Publication


Featured researches published by Yuzo Yamasaki.


European Journal of Radiology | 2014

Differentiation between benign phyllodes tumors and fibroadenomas of the breast on MR imaging.

Takeshi Kamitani; Yoshio Matsuo; Hidetake Yabuuchi; Nobuhiro Fujita; Michinobu Nagao; Satoshi Kawanami; Masato Yonezawa; Yuzo Yamasaki; Eriko Tokunaga; Makoto Kubo; Hidetaka Yamamoto; Hiroshi Honda

PURPOSE The purpose of this study was to determine the factors that contribute to the differentiation between phyllodes tumors (PTs) and fibroadenomas (FAs) on MR imaging. MATERIALS AND METHODS This retrospective study included 19 PTs and 18 FAs with ≥ 2 cm diameter. The presence or absence of a capsule and internal septum, the extent of lobulation, and the apparent diffusion coefficient (ADC) values were determined. The presence or absence of a cystic component, the time-intensity curve, and the signal intensity on delayed-phase contrast-enhanced T1WI were also evaluated in 31 patients (16 PTs and 17 FAs) who underwent a contrast-enhanced study. RESULTS Cystic components were seen in 10 of the 16 PTs (63%) and in 4 of the 17 FAs (24%; P=0.03). The PTs showed strong lobulation more frequently compared to the FAs (14/19 [74%] vs. 7/18 [39%], respectively; P=0.04). Though there was no significant difference, PT tended to be heterogeneous more frequently on the delayed phase of the contrast-enhanced T1WI compared to the FA (11/16 [69%] vs. 7/17 [41%], respectively). No significant difference was found in the other findings. CONCLUSIONS Although PTs and FAs show similar MR findings, the presence of a cystic component, strong lobulation, and heterogeneity on delayed-phase contrast-enhanced T1WI suggests a PT.


Congenital Heart Disease | 2015

Interventricular Dyssynchrony Using Tagging Magnetic Resonance Imaging Predicts Right Ventricular Dysfunction in Adult Congenital Heart Disease

Michinobu Nagao; Yuzo Yamasaki; Masato Yonezawa; Yoshio Matsuo; Takeshi Kamitani; Kenichiro Yamamura; Ichiro Sakamoto; Kohtaro Abe; Satoshi Kawanami; Hiroshi Honda

PURPOSE Right ventricular (RV) failure and ventricular dyssynchrony are strong determinants of prognosis in patients with adult congenital heart disease (ACHD). The aim of this study was to investigate the relationship between interventricular dyssynchrony (IVD) using cine-tagged magnetic resonance imaging (MRI) and RV dysfunction in ACHD patients. MATERIALS AND METHODS Sixty-seven patients with ACHD (38 with repaired tetralogy of Fallot; 22 with atrial septal defect; seven with ventricular septal defect) underwent tagging MRI. Time curves of myocardial circumferential strains for RV and left ventricular (LV) free walls were delivered from short-axis cine-tagging images. Contraction delay between RV and LV free walls was computed by cross-correlation analysis of the two strain time curves and was defined as the IVD time (msec). RESULTS IVD was significantly greater for patients with RV ejection fraction (RVEF) <40% (116 ± 58 msec) than for patients with RVEF ≥ 40% (65 ± 54 msec) and was significantly greater for patients with RV systolic pressure ≥ 40 mm Hg (112 ± 59 msec) than for patients with RV systolic pressure <40 mm Hg (49 ± 28 msec). Receiver operating characteristic analysis revealed optimal IVD thresholds for detecting patients with RVEF <40% with C-statistics of 0.76 and patients with RV systolic pressure ≥ 40 mm Hg with C-statistics of 0.81. CONCLUSION Quantification of IVD was possible using RV and LV strains derived from tagging MRI. IVD, represented as the time difference between LV and RV contractions, correlates with RV dysfunction. IVD may thus offer an indicator for RV failure in ACHD.


Clinical Radiology | 2015

Anterior mediastinal solid tumours in adults: characterisation using dynamic contrast-enhanced MRI, diffusion-weighted MRI, and FDG-PET/CT.

Hidetake Yabuuchi; Yoshio Matsuo; Kohtaro Abe; Shingo Baba; Shunya Sunami; Takeshi Kamitani; Masato Yonezawa; Yuzo Yamasaki; Satoshi Kawanami; Michinobu Nagao; Tatsuro Okamoto; K. Nakamura; Hidetaka Yamamoto; Masayuki Sasaki; Hiroshi Honda

AIM To find significant parameters to characterise anterior mediastinal solid tumours in adults using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), diffusion-weighted MRI (DWI), and combined 2-[(18)F]-fluoro-2-deoxy-d-glucose positron-emission tomography/computed tomography (FDG-PET/CT). MATERIALS AND METHODS Forty-eight histologically confirmed anterior mediastinal solid tumours in 48 patients (24 men, 24 women; age range 21-83 years, mean 50.7 years) were examined. The parameters analysed were maximal diameter, presence of capsule/septa on T2-weighted images, time-signal intensity curves (TICs), apparent diffusion coefficient (ADC), and maximum standardised uptake value (SUVmax). Also examined was whether any differences between histological types could be seen in these parameters. In a validation study, 42 anterior mediastinal solid tumours in 42 patients were examined consecutively. RESULTS The washout pattern on TIC was seen only in thymic epithelial tumours (20/32). SUVmax of lymphoma (mean, 17.9), malignant germ cell tumours (14.2), and thymic carcinomas (15.6) were significantly higher than that of thymomas (6.1). The mean maximal diameter of thymic epithelial tumours was significantly smaller than that of lymphomas (p<0.01) and malignant germ cell tumours (p<0.05). The validation study also yielded high accuracy (38/42, 91%) in differentiation among the anterior mediastinal solid tumours. CONCLUSION The SUVmax, TIC pattern on DCE-MRI, and maximal diameter might be useful to differentiate anterior mediastinal solid tumours in adults.


European Radiology | 2017

One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography.

Yuzo Yamasaki; Michinobu Nagao; Satoshi Kawanami; Takeshi Kamitani; Koji Sagiyama; Torahiko Yamanouchi; Ichiro Sakamoto; Kenichiro Yamamura; Hidetake Yabuuchi; Hiroshi Honda

ObjectivesTo investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements.MethodsTwenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs–RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson’s coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test.ResultsQp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size.Conclusions256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively.Key Points• Quantification of left-to-right shunting can be performed reliably and accurately by CT.• The sizes of defects and rims can be measured accurately using 256-slice CT.• 256-slice CT permits pretreatment evaluation of ASD non-invasively and comprehensively.


Acta Radiologica | 2015

Detectability of T1a lung cancer on digital chest radiographs: an observer-performance comparison among 2-megapixel general-purpose, 2-megapixel medical-purpose, and 3-megapixel medical-purpose liquid-crystal display (LCD) monitors.

Hidetake Yabuuchi; Yoshio Matsuo; Takeshi Kamitani; Mikako Jinnnouchi; Masato Yonezawa; Yuzo Yamasaki; Michinobu Nagao; Satoshi Kawanami; Tatsuro Okamoto; Masayuki Sasaki; Hiroshi Honda

Background There has been no comparison of detectability of small lung cancer between general and medical LCD monitors or no comparison of detectability of small lung cancer between solid and part-solid nodules. Purpose To compare the detectabilities of T1a lung cancer on chest radiographs on three LCD monitor types: 2-megapixel (MP) for general purpose (General), 2-MP for medical purpose (Medical), and 3-MP-Medical. Material and Methods Radiographs from forty patients with T1aN0M0 primary lung cancer (27 solid nodules, 13 part-solid nodules) and 60 patients with no abnormalities on both chest X-ray and computed tomography (CT) were consecutively collected. Five readers assessed 100 cases for each monitor. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jackknife method was used for statistical analysis. A P value of <0.05 was considered significant. Results The average AUC for all T1a lung cancer nodule detection using the 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.86, 0.89, and 0.89, respectively; there were no significant differences among them. The average AUC for part-solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.77, 0.86, and 0.89, respectively. There were significant differences between the 2-MP-General and 2-MP-Medical LCD monitors (P = 0.043) and between the 2-MP-General and 3-MP-Medical LCD monitors (P = 0.027). There was no significant difference between the 2-MP-Medical and 3-MP-Medical LCD monitors. The average AUC for solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.90, 0.90, and 0.88, respectively; there were no significant differences among them. The mean AUC values for all and part-solid nodules of the low-experienced readers were significantly lower than those of the high-experienced readers with the 2 M-GP color LCD monitor (P < 0.05). Conclusion Detectability of part-solid nodules using a general-purpose LCD monitor was significantly lower than those using medical-purpose LCD monitors.


European Journal of Radiology | 2013

Detectability of simulated pulmonary nodules on chest radiographs: Comparison between irradiation side sampling indirect flat-panel detector and computed radiography

Yuki Yano; Hidetake Yabuuchi; Nobukazu Tanaka; Junji Morishita; Tsutomu Akasaka; Yoshio Matsuo; Shunya Sunami; Takeshi Kamitani; Mikako Jinnouchi; Yuzo Yamasaki; Michinobu Nagao; Masayuki Sasaki

OBJECTIVE To compare the detectability of simulated pulmonary nodules on chest radiographs between an irradiation side sampling indirect flat-panel detector (ISS-FPD) and computed radiography (CR). MATERIALS AND METHODS This study was an observer performance study. Simulated pulmonary nodules of 8 mm in diameter were superimposed on an anthropomorphic chest phantom. Chest radiographs were acquired under 2 exposure levels (4 and 3.2 mAs) with the ISS-FPD and the CR. Six thoracic radiologists evaluated all 40 images (10 patterns × 2 different exposure doses × 2 different systems) for the presence or absence of a lesion over each of 12 defined areas on a 3-megapixel monochrome liquid-crystal display. Receiver operating characteristic (ROC) curves were obtained for observation in predefined 480 areas. A jackknife method was used for statistical analysis. Differences with a P value of <0.05 were considered significant. RESULTS The analysis of the observer detection of simulated pulmonary nodules showed larger areas under the ROC curve (AUC) by the ISS-FPD than by the CR. There was a statistically significant difference between the two systems at 3.2 mAs (P=0.0330). CONCLUSION The ISS-FPD was superior to the CR for the detection of simulated pulmonary nodules at 3.2 mAs.


The Journal of Thoracic and Cardiovascular Surgery | 2018

Computed tomography features of resected lung adenocarcinomas with spread through air spaces

Gouji Toyokawa; Yuichi Yamada; Tetsuzo Tagawa; Takeshi Kamitani; Yuzo Yamasaki; Mototsugu Shimokawa; Yoshinao Oda; Yoshihiko Maehara

Background Spread through air spaces (STAS) is a recently recognized invasive pattern of lung cancer defined as “micropapillary clusters, solid nests, or single cells beyond the edge of the tumor into air spaces.” Since STAS has been shown to be a significant prognosticator for the postoperative survival, predicting STAS preoperatively by computed tomography (CT) might help determine the optimum surgical procedures. Methods Information on STAS and preoperative CT was available in 327 patients with resected lung adenocarcinomas. STAS was defined as tumor cells within air spaces in the lung parenchyma beyond the edge of the main tumor. The association of STAS with CT characteristics, such as vascular convergence, ground‐glass opacity (GGO), air bronchogram, notch, pleural indentation, spiculation, and cavitation, was analyzed. Results Among the 327 patients with resected adenocarcinoma, 191 (58.4%) were positive for STAS. A univariable analysis demonstrated that STAS‐positive adenocarcinomas were significantly associated with a larger radiologic tumor diameter (P = .02), the presence of vascular convergence (P < .01), notch (P < .01), pleural indentation (P = .03), spiculation (P < .01), and the absence of GGO (P < .01) compared with STAS‐negative ones. In a multivariable analysis, the presence of notch (P = .01) and the absence of GGO (P < .01) were shown to be significantly associated with the STAS phenomenon. The odds ratio for STAS of notch‐positive and GGO‐negative adenocarcinomas against notch‐negative and GGO‐positive ones was 5.01 (P < .01). Conclusions The presence of notch and the absence of GGO were independently associated with the STAS phenomenon. These results will prove helpful in identifying STAS‐positive adenocarcinoma by CT before surgical resection.


Acta Radiologica | 2017

Detectability of BI-RADS category 3 or higher breast lesions and reading time on mammography: comparison between 5-MP and 8-MP LCD monitors

Hidetake Yabuuchi; Satoshi Kawanami; Takeshi Kamitani; Tomomi Matsumura; Yuzo Yamasaki; Junji Morishita; Hiroshi Honda

Background Five-megapixel (MP) displays are recommended as soft copy devices for digital mammogram. An 8-MP liquid crystal display (LCD) (two 4-MP displays within one display) might offer the advantage of being able to view biplane mammography more easily than the dual planes of 5-MP LCDs. Purpose To compare detectability of Breast Imaging Reporting and Data System (BI-RADS) category 3 or higher lesions and reading time on mammography between 5- MP and 8-MP LCDs. Material and Methods The mammograms of 240 breasts of 120 patients including 60 breasts with BI-RADS category 3 or higher lesions and 180 breasts with normal or category 2 lesions were enrolled. All bilateral mammograms were displayed on bifacial 5-MP LCDs or an 8-MP LCD (two 4-MP displays within one display). Six radiologists assessed 240 breasts on each display. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jack-knife method was used for statistical analysis. We employed a paired t-test to determine whether any significant differences existed in the reading time between two different displays. A P value < 0.05 was considered significant. Results The mean areas under the ROC curve obtained using 5-MP and 8-MP LCDs were 0.925 and 0.915, respectively, and there was no significant difference (P = 0.46). There was also no significant difference in the reading time between two types of displays (57.8 min. vs. 51.5 min, P = 0.39). Conclusion The detectability of BI-RADS category 3 or higher lesions and reading time using an 8-MP LCD were comparable to those using a 5-MP LCD.


European Journal of Radiology | 2016

Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging

Kazuya Nagatomo; Hidetake Yabuuchi; Yuzo Yamasaki; Hiroshi Narita; Seiji Kumazawa; Tsukasa Kojima; Noriyuki Sakai; Masahumi Masaki; Hiroshi Kimura

OBJECTIVES To elucidate the utility of PROPELLER for motion artefact reduction on shoulder MRI and to examine the influence of streak artefacts on diagnosis of clinical images. METHODS 15 healthy volunteers and 48 patients underwent shoulder MRI with/without PROPELLER (coronal oblique proton density-fast spin echo [PD-FSE], sagittal oblique T2-FSE). In a volunteer study, all sequences were performed in both static and exercise-loaded conditions. Two radiologists graded artefacts and delineation of various anatomical structures in the volunteer study and motion and streak artefacts in the clinical study. Mean scores were compared between sequences with/without PROPELLER. In the clinical study, mean scores of motion artefacts were compared with mean scores of streak artefacts. Wilcoxon signed-rank test was used for all comparisons. RESULTS In both studies, PROPELLER significantly reduced motion artefacts (P<0.05). In the volunteer study, it significantly improved delineations in sagittal oblique images in the exercise-loaded condition (P<0.05). In the clinical study, streak artefacts appeared dominantly on images with PROPELLER (P<0.05), but influenced diagnosis to a lesser extent than motion artefacts. CONCLUSION PROPELLER can reduce motion artefacts in shoulder MRI. While it does cause streak artefacts, it affects diagnosis to a lesser extent.


Magnetic Resonance Imaging | 2017

Quantification of myocardial oxygenation in heart failure using blood-oxygen-level-dependent T2* magnetic resonance imaging: Comparison with cardiopulmonary exercise test

Michinobu Nagao; Yuzo Yamasaki; Satoshi Kawanami; Takeshi Kamitani; Koji Sagiyama; Taiki Higo; Tomomi Ide; Atsushi Takemura; Umiko Ishizaki; Kenji Fukushima; Yuji Watanabe; Hiroshi Honda

PURPOSE Quantification of myocardial oxygenation (MO) in heart failure (HF) has been less than satisfactory. This has necessitated the use of invasive techniques to measure MO directly or to determine the oxygen demand during exercise using the cardiopulmonary exercise (CPX) test. We propose a new quantification method for MO using blood-oxygen-level-dependent (BOLD) myocardial T2* magnetic resonance imaging (M-T2* MRI), and investigate its correlation with CPX results. METHODS Thirty patients with refractory HF who underwent cardiac MRI and CPX test for heart transplantation, and 24 healthy, age-matched volunteers as controls were enrolled. M-T2* imaging was performed using a 3-Tesla and multi-echo gradient-echo sequence. M-T2* was calculated by fitting the signal intensity data for the mid-left ventricular septum to a decay curve. M-T2* was measured under room-air (T2*-air) and after inhalation of oxygen for 10min at a flow rate of 10L/min (T2*-oxy). MO was defined as the difference between the two values (ΔT2*). Changes in M-T2* at the two conditions and ΔT2* between the two groups were compared. Correlation between ΔT2* and CPX results was analyzed using the Pearson coefficient. RESULTS T2*-oxy was significantly greater than T2*-air in patients with HF (29.9±7.3ms vs. 26.7±6.0ms, p<0.001), whereas no such difference was observed in controls (25.5±4.0ms vs. 25.4±4.4ms). ΔT2* was significantly greater for patients with HF than for controls (3.2±4.5ms vs. -0.1±1.3ms, p<0.001). A significant correlation between ΔT2* and CPX results (peak VO2, r=-0.46, p<0.05; O2 pulse, r=-0.54, p<0.005) was observed. CONCLUSION ΔT2* is increased T2*-oxy is greater in patients with HF, and is correlated with oxygen metabolism during exercise as measured by the CPX test. Hence, ΔT2* can be used as a surrogate marker of MO instead of CPX test.

Collaboration


Dive into the Yuzo Yamasaki's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge