Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Zach Nadler is active.

Publication


Featured researches published by Zach Nadler.


Investigative Ophthalmology & Visual Science | 2013

In vivo lamina cribrosa micro-architecture in healthy and glaucomatous eyes as assessed by optical coherence tomography.

Bo Wang; Jessica E. Nevins; Zach Nadler; Gadi Wollstein; Hiroshi Ishikawa; Richard A. Bilonick; Larry Kagemann; Ian A. Sigal; Ireneusz Grulkowski; Jonathan J. Liu; Martin F. Kraus; Chen D. Lu; Joachim Hornegger; James G. Fujimoto; Joel S. Schuman

PURPOSE The lamina cribrosa (LC) is a prime location of glaucomatous damage. The purpose of this study was to compare LC 3-dimensional micro-architecture between healthy and glaucomatous eyes in vivo by using optical coherence tomography (OCT). METHODS Sixty-eight eyes (19 healthy and 49 glaucomatous) from 47 subjects were scanned in a 3.5 × 3.5 × 3.64-mm volume (400 × 400 × 896 pixels) at the optic nerve head by using swept-source OCT. The LC micro-architecture parameters were measured on the visible LC by an automated segmentation algorithm. The LC parameters were compared to diagnosis and visual field mean deviation (VF MD) by using a linear mixed effects model accounting for age. RESULTS The average VF MD for the healthy and glaucomatous eyes was -0.50 ± 0.80 dB and -7.84 ± 8.75 dB, respectively. Beam thickness to pore diameter ratio (P = 0.04) and pore diameter standard deviation (P < 0.01) were increased in glaucomatous eyes. With worse MD, beam thickness to pore diameter ratio (P < 0.01), pore diameter standard deviation (P = 0.05), and beam thickness (P < 0.01) showed a statistically significant increase while pore diameter (P = 0.02) showed a significant decrease. There were no significant interactions between any of the parameters and age (all P > 0.05). CONCLUSIONS Glaucomatous micro-architecture changes in the LC, detected by OCT analysis, reflect beams remodeling and axonal loss leading to reduction in pore size and increased pore size variability.


Biomedical Optics Express | 2013

Automated lamina cribrosa microstructural segmentation in optical coherence tomography scans of healthy and glaucomatous eyes

Zach Nadler; Bo Wang; Gadi Wollstein; Jessica E. Nevins; Hiroshi Ishikawa; Larry Kagemann; Ian A. Sigal; R. Daniel Ferguson; Daniel X. Hammer; Ireneusz Grulkowski; Jonathan J. Liu; Martin F. Kraus; Chen D. Lu; Joachim Hornegger; James G. Fujimoto; Joel S. Schuman

We demonstrate an automated segmentation method for in-vivo 3D optical coherence tomography (OCT) imaging of the lamina cribrosa (LC). Manual segmentations of coronal slices of the LC were used as a gold standard in parameter selection and evaluation of the automated technique. The method was validated using two prototype OCT devices; each had a subject cohort including both healthy and glaucomatous eyes. Automated segmentation of in-vivo 3D LC OCT microstructure performed comparably to manual segmentation and is useful for investigative research and in clinical quantification of the LC.


Investigative Ophthalmology & Visual Science | 2014

IOP Elevation Reduces Schlemm's Canal Cross-Sectional Area

Larry Kagemann; Bo Wang; Gadi Wollstein; Hiroshi Ishikawa; Jessica E. Nevins; Zach Nadler; Ian A. Sigal; Richard A. Bilonick; Joel S. Schuman

PURPOSE Previously, we demonstrated reduced Schlemms canal cross-sectional area (SC-CSA) with increased perfusion pressure in a cadaveric flow model. The purpose of the present study was to determine the effect of acute IOP elevation on SC-CSA in living human eyes. METHODS The temporal limbus of 27 eyes of 14 healthy subjects (10 male, 4 female, age 36 ± 13 years) was imaged by spectral-domain optical coherence tomography at baseline and with IOP elevation (ophthalmodynamometer set at 30-g force). Intraocular pressure was measured at baseline and with IOP elevation by Goldmann applanation tonometry. Vascular landmarks were used to identify corresponding locations in baseline and IOP elevation scan volumes. Schlemms canal CSA at five locations within a 1-mm length of SC was measured in ImageJ as described previously. A linear mixed-effects model quantified the effect of IOP elevation on SC-CSA. RESULTS The mean IOP increase was 189%, and the mean SC-CSA decrease was 32% (P < 0.001). The estimate (95% confidence interval) for SC-CSA response to IOP change was -66.6 (-80.6 to -52.7) μm(2)/mm Hg. CONCLUSIONS Acute IOP elevation significantly reduces SC-CSA in healthy eyes. Acute dynamic response to IOP elevation may be a useful future characterization of ocular health in the management of glaucoma.


Investigative Ophthalmology & Visual Science | 2014

In vivo three-dimensional characterization of the healthy human lamina cribrosa with adaptive optics spectral-domain optical coherence tomography.

Zach Nadler; Bo Wang; Joel S. Schuman; R. Daniel Ferguson; Ankit H. Patel; Daniel X. Hammer; Richard A. Bilonick; Hiroshi Ishikawa; Larry Kagemann; Ian A. Sigal; Gadi Wollstein

PURPOSE To characterize the in vivo three-dimensional (3D) lamina cribrosa (LC) microarchitecture of healthy eyes using adaptive optics spectral-domain optical coherence tomography (AO-SDOCT). METHODS A multimodal retinal imaging system with a light source centered at 1050 nm and AO confocal scanning laser ophthalmoscopy was used in this study. One randomly selected eye from 18 healthy subjects was scanned in a 6° × 6° window centered on the LC. Subjects also underwent scanning with Cirrus HD-OCT. Lamina cribrosa microarchitecture was semiautomatically segmented and quantified for connective tissue volume fraction (CTVF), beam thickness, pore diameter, pore area, and pore aspect ratio. The LC was assessed in central and peripheral regions of equal areas and quadrants and with depth. A linear mixed effects model weighted by the fraction of visible LC was used to compare LC structure between regions. RESULTS The nasal quadrant was excluded due to poor visualization. The central sector showed greater CTVF and thicker beams as compared to the periphery (P < 0.01). Both superior and inferior quadrants showed greater CTVF, pore diameter, and pore mean area than the temporal quadrant (P < 0.05). Depth analysis showed that the anterior and posterior aspects of the LC contained smaller pores with greater density and thinner beams as compared to the middle third (P < 0.05). The anterior third also showed a greater CTVF than the middle third (P < 0.05). CONCLUSIONS In vivo analysis of healthy eyes using AO-SDOCT showed significant, albeit small, regional variation in LC microarchitecture by quadrant, radially, and with depth, which should be considered in further studies of the LC.


Biomedical Optics Express | 2014

Repeatability of in vivo 3D lamina cribrosa microarchitecture using adaptive optics spectral domain optical coherence tomography

Zach Nadler; Bo Wang; Gadi Wollstein; Jessica E. Nevins; Hiroshi Ishikawa; Richard A. Bilonick; Larry Kagemann; Ian A. Sigal; R. Daniel Ferguson; Ankit H. Patel; Daniel X. Hammer; Joel S. Schuman

We demonstrate the repeatability of lamina cribrosa (LC) microarchitecture for in vivo 3D optical coherence tomography (OCT) scans of healthy, glaucoma suspects, and glaucomatous eyes. Eyes underwent two scans using a prototype adaptive optics spectral domain OCT (AO-SDOCT) device from which LC microarchitecture was semi-automatically segmented. LC segmentations were used to quantify pore and beam structure through several global microarchitecture parameters. Repeatability of LC microarchitecture was assessed qualitatively and quantitatively by calculating parameter imprecision. For all but one parameters (pore volume) measurement imprecision was <4.7% of the mean value, indicating good measurement reproducibility. Imprecision ranged between 27.3% and 54.5% of the population standard deviation for each parameter, while there was not a significant effect on imprecision due to disease status, indicating utility in testing for LC structural trends.


British Journal of Ophthalmology | 2014

Characterisation of Schlemm's canal cross-sectional area

Larry Kagemann; Jessica E. Nevins; Ninj-Jiun Jan; Gadi Wollstein; Hiroshi Ishikawa; Janice Kagemann; Ian A. Sigal; Zach Nadler; Yun Ling; Joel S. Schuman

Purpose To compare three methods of Schlemms canal (SC) cross-sectional area (CSA) measurement. Methods Ten eyes (10 healthy volunteers) were imaged three times using spectral-domain optical coherence tomography (Cirrus HD-OCT, Zeiss, Dublin, California, USA). Aqueous outflow vascular structures and SC collector channel ostia were used as landmarks to identify a reference location within the limbus. SC CSA was assessed within a 1 mm segment (±15 frames of the reference, 31 frames in all) by three techniques. (1) Using a random number table, SC CSA in five random frames from the set of 31 surrounding the reference were measured and averaged. (2) The most easily visualised SC location (subjective) was measured, and (3) SC CSA was measured in all 31 consecutive B-scans, and averaged. (comprehensive average, gold standard). Subjective and random CSAs were compared with the comprehensive by general estimating equation modelling, and structural equation modelling quantified agreement. Results The average from five random locations (4175±1045 µm2) was not significantly different than that obtained from the gold standard comprehensive assessment (4064±1308 µm2, p=0.6537). Subjectively located SC CSA (7614±2162 µm2) was significantly larger than the comprehensive gold standard SC CSA (p<0.0001). The average of five random frames produced significantly less bias than did subjective location, yielding a calibration line crossing the ‘no-bias’ line. Discussion Subjectively located SC CSA measurements produce high estimates of SC CSA. SC assessed by measuring five random locations estimate CSA was similar to the gold standard estimate.


PLOS ONE | 2014

Gold Nanorods as a Contrast Agent for Doppler Optical Coherence Tomography

Bo Wang; Larry Kagemann; Joel S. Schuman; Hiroshi Ishikawa; Richard A. Bilonick; Yun Ling; Ian A. Sigal; Zach Nadler; Andrew Francis; Michelle Gabriele Sandrian; Gadi Wollstein

Purpose To investigate gold nanorods (GNRs) as a contrast agent to enhance Doppler optical coherence tomography (OCT) imaging of the intrascleral aqueous humor outflow. Methods A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC) to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×1012 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus. Results At the GNR concentration of 0.7×1012 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of −0.025 to 0.037 mm/s (p = 0.6435). Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system. Conclusions GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.


PLOS ONE | 2014

Reproducibility of In-Vivo OCT Measured Three-Dimensional Human Lamina Cribrosa Microarchitecture

Bo Wang; Jessica E. Nevins; Zach Nadler; Gadi Wollstein; Hiroshi Ishikawa; Richard A. Bilonick; Larry Kagemann; Ian A. Sigal; Ireneusz Grulkowski; Jonathan J. Liu; Martin F. Kraus; Chen David Lu; Joachim Hornegger; James G. Fujimoto; Joel S. Schuman

Purpose To determine the reproducibility of automated segmentation of the three-dimensional (3D) lamina cribrosa (LC) microarchitecture scanned in-vivo using optical coherence tomography (OCT). Methods Thirty-nine eyes (8 healthy, 19 glaucoma suspects and 12 glaucoma) from 49 subjects were scanned twice using swept-source (SS−) OCT in a 3.5×3.5×3.64 mm (400×400×896 pixels) volume centered on the optic nerve head, with the focus readjusted after each scan. The LC was automatically segmented and analyzed for microarchitectural parameters, including pore diameter, pore diameter standard deviation (SD), pore aspect ratio, pore area, beam thickness, beam thickness SD, and beam thickness to pore diameter ratio. Reproducibility of the parameters was assessed by computing the imprecision of the parameters between the scans. Results The automated segmentation demonstrated excellent reproducibility. All LC microarchitecture parameters had an imprecision of less or equal to 4.2%. There was little variability in imprecision with respect to diagnostic category, although the method tends to show higher imprecision amongst healthy subjects. Conclusion The proposed automated segmentation of the LC demonstrated high reproducibility for 3D LC parameters. This segmentation analysis tool will be useful for in-vivo studies of the LC.


PLOS ONE | 2013

Three-dimensional spectral-domain optical coherence tomography data analysis for glaucoma detection.

Juan Xu; Hiroshi Ishikawa; Gadi Wollstein; Richard A. Bilonick; Lindsey S. Folio; Zach Nadler; Larry Kagemann; Joel S. Schuman

Purpose To develop a new three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) data analysis method using a machine learning technique based on variable-size super pixel segmentation that efficiently utilizes full 3D dataset to improve the discrimination between early glaucomatous and healthy eyes. Methods 192 eyes of 96 subjects (44 healthy, 59 glaucoma suspect and 89 glaucomatous eyes) were scanned with SD-OCT. Each SD-OCT cube dataset was first converted into 2D feature map based on retinal nerve fiber layer (RNFL) segmentation and then divided into various number of super pixels. Unlike the conventional super pixel having a fixed number of points, this newly developed variable-size super pixel is defined as a cluster of homogeneous adjacent pixels with variable size, shape and number. Features of super pixel map were extracted and used as inputs to machine classifier (LogitBoost adaptive boosting) to automatically identify diseased eyes. For discriminating performance assessment, area under the curve (AUC) of the receiver operating characteristics of the machine classifier outputs were compared with the conventional circumpapillary RNFL (cpRNFL) thickness measurements. Results The super pixel analysis showed statistically significantly higher AUC than the cpRNFL (0.855 vs. 0.707, respectively, p = 0.031, Jackknife test) when glaucoma suspects were discriminated from healthy, while no significant difference was found when confirmed glaucoma eyes were discriminated from healthy eyes. Conclusions A novel 3D OCT analysis technique performed at least as well as the cpRNFL in glaucoma discrimination and even better at glaucoma suspect discrimination. This new method has the potential to improve early detection of glaucomatous damage.


Optometry and Vision Science | 2012

Clinical application of ocular imaging.

Zach Nadler; Gadi Wollstein; Hiroshi Ishikawa; Joel S. Schuman

ABSTRACT The broadening frontier of technology used in ocular imaging is continuously affecting the landscape of clinical eye care. With each wave of enhanced imaging modalities, the field faces the difficulties of optimally incorporating these devices into the clinic. Ocular imaging devices have been widely incorporated into clinical management after their diagnostic capabilities have been documented in a wide range of ocular disease. In this review, we are presenting the main commercially available devices for imaging of the posterior segment of the eye.

Collaboration


Dive into the Zach Nadler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Larry Kagemann

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bo Wang

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar

Ian A. Sigal

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Daniel X. Hammer

Center for Devices and Radiological Health

View shared research outputs
Top Co-Authors

Avatar

James G. Fujimoto

Massachusetts Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge