Zafer Ari
Istanbul University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Zafer Ari.
Spine | 2004
Mustafa Bozbuga; Adnan Ozturk; Zafer Ari; Kayihan Sahinoglu; Bulent Bayraktar; Aycicek Cecen
Study Design. A morphometric evaluation of pedicle projections in 29 cervical spinal columns (C3–C7) for three-dimensional surgical anatomy for safe surgery was proposed. Objective. In this study, pedicles and intimate structures of the subaxial vertebrae from C3 to C7 were evaluated to provide some morphometric data for cervical transpedicular screw fixation. Summary of Background Data. Detailed knowledge of surgical anatomy and variation of the subaxial vertebrae is a must for safe and effective surgery of the region. Although there are several clinical studies of transpedicular fixation, few studies have been performed on cervical pedicle measurements and their projection. Methods. In 29 dried bone cervical spinal columns (C3–C7), pedicle dimensions (pedicle height, width, length), measurements of lateral mass and pedicle length distance and pedicle axis length, investigation of distances of superior facet-midpedicle axis and inferior facet-midpedicle axis, and transverse and sagittal angles of the pedicles were performed in linear and angular measurements. Results. The obtained data from the series revealed that the mean values were approximately ranging from 6.7 to 7.2 mm for pedicle height, 4.4 to 4.9 mm for pedicle width, 5.3 to 6.2 mm for pedicle length, 15.3 to 16.0 mm for lateral mass and pedicle length, 22.2 to 27.7 mm for pedicle axis length, 3.8 to 5.3 mm for superior facet-midpedicle axis distance, 9.9 to 12.0 mm for inferior facet-midpedicle axis distance, 42.3° to 51.5° for transverse angle, and 5.2° to 14.1° for sagittal angle. Conclusions. Linear measurements of pedicle dimensions and also axial angles from horizontal and vertical planes may provide some anatomic limitations for subaxial cervical transpedicular screw fixation, and also contribute to the safety of the surgical procedure. One should also rely on tomographic data and computer-assisted guidance systems.
Okajimas Folia Anatomica Japonica | 1999
Mustafa Bozbuga; Adnan Ozturk; Bulent Bayraktar; Zafer Ari; Kayihan Sahinoglu; Gürsel Polat; Isik Güurel
Archive | 2009
Ilke Ali Gurses; Aysin Kale; Ozcan Gayretli; Bulent Bayraktar; Ahmet Usta; Mahmut Enes Kayaalp; Zafer Ari
Saudi Medical Journal | 2009
Aysin Kale; Funda Aksu; Adnan Ozturk; Ilke Ali Gurses; Ozcan Gayretli; Zeybek Fg; Bulent Bayraktar; Zafer Ari; Neslihan Onder
Okajimas Folia Anatomica Japonica | 1998
Mustafa Bozbuga; Adnan Ozturk; Zafer Ari; Kayihan Sahinoglu; Bulent Bayraktar; Gürsel Polat; Isik Gürel
Okajimas Folia Anatomica Japonica | 1999
Mustafa Bozbuga; Adnan Ozturk; Zafer Ari; Bulent Bayraktar; Kayihan Sahinoglu; Isik Gürel
Neurosciences (Riyadh, Saudi Arabia) | 2009
Aysin Kale; Adnan Ozturk; Funda Aksu; Ilke Ali Gurses; Ozcan Gayretli; Bulent Bayraktar; Zeybek Fg; Taskara N; Zafer Ari; Kayihan Sahinoglu
Okajimas Folia Anatomica Japonica | 1999
Adnan Ozturk; Mustafa Bozbuga; Bulent Bayraktar; Zafer Ari; Kayihan Sahinoglu; Gürsel Polat; Isik Gürel
Okajimas Folia Anatomica Japonica | 1999
Nilgun Bozbuga; Kayihan Sahinoglu; Zafer Ari; Adnan Ozturk; Bulent Bayraktar; Omer Isik; Cevat Yakut
Acta Orthopaedica et Traumatologica Turcica | 1998
Ercan Olcay; Adnan Ozturk; Bulent Aksoy; Zafer Ari; Murat Bülbül; Kayihan Sahinoglu