Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ziad Hassan is active.

Publication


Featured researches published by Ziad Hassan.


Journal of Refractive Surgery | 2013

Repeatability of ocular biomechanical data measurements with a scheimpflug-based noncontact device on normal corneas

Gabor Nemeth; Ziad Hassan; Adrienne Csutak; Eszter Szalai; András Berta; László Módis

PURPOSE To analyze the repeatability of a new device measuring ocular biomechanical properties, central corneal thickness (CCT), and intraocular pressure (IOP) and to investigate these parameters and their correlations in healthy eyes. METHODS Three consecutive measurements were performed on each eye using the CorVis ST device (Oculus Optikgeräte, Inc., Wetzler, Germany). Ten specific parameters, CCT, and IOP were measured. Biometric data were recorded with IOLMaster (Carl Zeiss Meditec, Jena, Germany). RESULTS This study comprised 75 eyes of 75 healthy volunteers (mean age: 61.24 ± 15.72 years). Mean IOP was 15.02 ± 2.90 mm Hg and mean CCT was 556.33 ± 33.13 μm. Intraclass correlation coefficient (ICC) was 0.865 for IOP and 0.970 for CCT, and coefficient of variation was 0.069 for IOP and 0.008 for CCT. ICC was 0.758 for maximum amplitude at highest concavity and 0.784 for first applanation time, and less than 0.6 for all other parameters. The device-specific data showed no significant relationship with age and axial length. Flattest and steepest keratometric values and IOP showed a significant correlation with the 10 device-specific parameters. CONCLUSIONS The CorVis ST showed high repeatability for only IOP and pachymetric values. Single measurements are not reliable for the 10 device-specific parameters. The device allows for conducting clinical examinations and screening for surgeries altering ocular biomechanical properties with some form of averaging of multiple measurements.


Journal of Cataract and Refractive Surgery | 2012

Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus

Eszter Szalai; András Berta; Ziad Hassan; László Módis

PURPOSE: To evaluate the repeatability and reliability of a recently introduced swept‐source Fourier‐domain anterior segment optical coherence tomography (AS‐OCT) system and a high‐resolution Scheimpflug camera and to assess the agreement between the 2 instruments when measuring healthy eyes and eyes with keratoconus. SETTING: Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary. DESIGN: Evaluation of diagnostic test or technology. METHODS: Three consecutive series of anterior segment images were taken with AS‐OCT (Casia SS‐1000) followed by rotating Scheimpflug imaging (Pentacam high resolution). Axial keratometry in the steep and flat meridians and astigmatism values were recorded. Pachymetry in the apex, center, and the thinnest position and anterior chamber depth (ACD) measurements were also taken. RESULTS: This study enrolled 57 healthy volunteers (57 eyes) and 56 patients (84 eyes) with keratoconus. Significant difference was found in all measured anterior segment parameters between normal eyes and keratoconic eyes (P<.05). In keratoconic eyes, the difference between repeated measurements was less with AS‐OCT than with Scheimpflug imaging in every keratometry and astigmatism value, in apical thickness, and in ACD. For keratometry, the thinnest and central pachymetry measurement repeatability was better in healthy eyes than in keratoconic eyes with both instruments. In general, the mean difference between AS‐OCT and Scheimpflug imaging was higher in cases of keratoconus. CONCLUSIONS: Significant differences in keratometry, pachymetry, and ACD results were found between AS‐OCT and Scheimpflug imaging. However, the repeatability of the measurements was comparable. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.


Contact Lens and Anterior Eye | 2014

Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery

Ziad Hassan; László Módis; Eszter Szalai; András Berta; Gabor Nemeth

PURPOSE To analyze the early results of a new device measuring ocular biomechanics after corneal refractive surgery. PATIENTS AND METHODS Thirty nine refractive surgery patients were enrolled in the study (age: 32.6±9.9 years). Laser in situ keratomileusis (LASIK) was performed on 52 eyes of 26 patients and photorefractive keratectomy (PRK) was done on 26 eyes of 13 patients. Ten device-specific biomechanical parameters, intraocular pressure (IOP) and pachymetry were measured preoperatively and at day 1, week 1 and month 1 after the surgeries with a new technology based on Scheimpflug imaging (CorVis ST, Oculus). RESULTS In case of LASIK, the day after the procedure, radius values showed significant differences compared to preoperative data. One month after surgery, radius values, velocity of the second applanation and pachymetry showed significant differences compared to preoperative data. In case of PRK, the day after the procedure, significant differences in IOP, maximum amplitude at the apex, A1 time, A2 velocity and highest concavity time were measured. After 1 month of PRK, there were no differences in the parameters compared to preoperative data except pachymetry. CONCLUSIONS We observed that some specific biomechanical parameters changed measured with CorVis ST after LASIK and PRK, in the early postoperative time. However, most of these parameters remain unchanged after one month of LASIK and PRK compared to preoperative data.


Cornea | 2013

Assessment of Tear Osmolarity and Other Dry Eye Parameters in Post-LASIK Eyes

Ziad Hassan; Eszter Szalai; András Berta; László Módis; Gabor Nemeth

Purposes: To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Methods: Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. Results: The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). Conclusions: During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.


Journal of Refractive Surgery | 2014

Analysis of surgically induced astigmatism on the posterior surface of the cornea.

Gabor Nemeth; András Berta; Eszter Szalai; Ziad Hassan; László Módis

PURPOSE To measure surgically induced astigmatism (SIA) on the posterior surface of the cornea using Scheimpflug-based keratometry on eyes with with-the-rule astigmatism. METHODS Repeated Scheimpflug-based keratometry was obtained preoperatively and a mean of 8.65 weeks postoperatively following superior clear corneal incisions. Differences in the keratometric values and SIA were determined on the anterior and posterior surfaces separately and the data were analyzed. RESULTS The study included 88 eyes of 88 patients (age range: 46.4 to 87.5 years), with the steepest total corneal meridian between 75° and 105°. Preoperatively, the magnitude of the anterior and posterior corneal astigmatism was 0.74 ± 0.44 and 0.29 ± 0.14 diopters (D), respectively, which was greater than 0.5 D in 10 eyes (11.36%). The difference between preoperative and postoperative keratometric data on the posterior surface was significant, as was the difference between the preoperative and postoperative posterior astigmatism. The mean magnitude of posterior corneal SIA was 0.32 ± 0.29 D, which was 0.5 D or greater in 22 eyes (25.00%). A statistically significant correlation was observed between the diopter of the preoperatively measured posterior corneal astigmatism and the postoperative SIA on the posterior surface (r = 0.34, P = .001). The correlation was not significant between SIA on the anterior and posterior surfaces (r = 0.10, P = .36). CONCLUSIONS SIA on the posterior surface of the cornea may have a significant role, especially in cases of toric intraocular lens implantation. Posterior corneal astigmatism and SIA may have a significant clinical impact on more precise planning of cataract surgeries.


Cornea | 2014

Evaluation of Posterior Astigmatism Measured With Scheimpflug Imaging

Gabor Nemeth; András Berta; Agnes Lipecz; Ziad Hassan; Eszter Szalai; László Módis

Purpose: Our aim was to assess the corneal power, axis, and age dependence of the anterior and posterior corneal surfaces with Scheimpflug imaging. Methods: Patients older than 10 years without a history of ocular surgery, corneal diseases, contact lens wearing, or severe dry eye were enrolled. Data regarding the anterior and posterior cornea were analyzed by means of Scheimpflug imaging (Pentacam HR). Results: The median age was 46.8 years (range: 10.0–90.3), and involved 827 eyes of 827 patients. Posterior corneal astigmatism was a median of −0.30 diopters (D) and exceeded 0.50 D in 12.56%. The ratio of the anterior-to-posterior corneal radius was a median of 1.217 (range: 1.021–1.402). The correlation between this ratio and age was significant (r = −0.219; P < 0.001). The correlation between anterior and posterior corneal astigmatism and age was significant. At the anterior surface, the ratio of with-the-rule astigmatism was 80.0% for the age range 10 to 20, decreasing to 36.0% for those aged over 81 years, whereas the ratio of against-the-rule astigmatism increased from 7.1% to 44.0%. At the posterior surface, the ratio of with-the-rule astigmatism was 94.3% for the age range 10 to 20 years, decreasing to 84.0% for those aged over 81 years, whereas the ratio of against-the-rule astigmatism increased from 1.4% to 8.0%. Conclusions: The posterior cornea significantly influences corneal astigmatism. Its power value and orientation are much more stable with advancing age compared with anterior surface values.


PLOS ONE | 2013

Alterations of Tear Mediators in Patients with Keratoconus after Corneal Crosslinking Associate with Corneal Changes

Bence Lajos Kolozsvári; András Berta; Goran Petrovski; Kata Miháltz; Péter Gogolák; Éva Rajnavölgyi; Ziad Hassan; Péter Széles; Mariann Fodor

Keratoconus (KC) is the most common primary corneal ectatic disease which has considerable importance in public health. Corneal collagen crosslinking (CXL) is a procedure to mitigate progression of KC and reduce demand for corneal transplantation. Although studies have proven the efficacy of CXL regarding corneal shape, none have investigated the effects of CXL on tear biomarkers which are useful tools to understand molecular mechanisms behind CXL. Our purpose was to determine the effect of CXL on tear mediators in patients with KC and analyze associations with corneal changes. Tear samples were collected pre-CXL from 26 eyes of 23 patients and during a 12-month follow-up. The mediators’ concentration was measured by Cytometric Bead Array technology. Corneal topography parameters measured by Scheimpflug Camera included: Thinnest-corneal-thickness (ThCT), keratometry values (K1, K2), Radii-Minimum (Rmin), Keratoconus-Index (KI), Center-KI (CKI), Index-of-Height Asymmetry (IHA) and Index-of-Surface Variance (ISV). At baseline, KI was correlated negatively with chemokine (C-C motif) ligand 5 (CCL5) (p=0.015) and matrix metalloproteinase (MMP)-13 (p=0.007). At day 4, interleukin (IL)-6 and IL-8 increased, while IL-13, IL-17A, interferon (IFN)-γ, CCL5, MMP-13, epidermal growth factor (EGF), nerve growth factor (NGF) and plasminogen activator inhibitor (PAI-1) decreased significantly compared to pre-CXL concentrations (p≤0.02). At 6 months tissue plasminogen activator (t-PA) increased (p=0.02), while at 12 months Rmin increased (p≤0.004), and IL-6 and CXCL8 (p=0.005 and p=0.047) as well as K1, ISV and KI decreased. After 6 months CKI and ISV showed significant associations with IL-17A; CKI with IL-13 and ThCT with IL-13 (p≤0.02), while at 12 months there were reverse associations between ThCT and IL-6, IL-13, INFγ, CCL5 and PAI-1 (p≤0.02). Alterations of mediators in tear fluid after CXL associate with topographic changes highlight the fact that many mediators are involved in the complex mechanisms after CXL. Further studies on biomarkers to investigate the efficacy of CXL are needed.


European Journal of Ophthalmology | 2013

Assessment of corneal topography indices after collagen crosslinking for keratoconus

Ziad Hassan; Eszter Szalai; László Módis; András Berta; Gabor Nemeth

Purpose Riboflavin UVA (collagen crosslinking [CXL]) treatment for keratoconus is a method for stabilizing or improving corneal properties. Our aim was to evaluate changes in corneal topography indices after CXL. Methods A total of 38 eyes of 25 patients (mean age 29.36 ± 9.7 years) were treated with CXL technique. The follow-up period was 36 months. Slit-lamp examination, visual acuity tests, and pachymetry measurements were performed; in order to obtain the following numerical data, corneal topography (TMS-4; Tomey) was used: simulated keratometry (K1, K2), CYL (cylinder value), SAI (surface asymmetry index), IAI (irregular astigmatism index), SRI (surface regulatory index), ACP (average corneal power), and CEI (corneal eccentricity index). Treatments were performed with In-Pro CCL-Lix (Germany) equipment. Results The values of mean K1 (p = 0.82), cylinder (p = 0.73), SAI (p = 0.99), IAI (p = 0.82), SRI (p = 0.73), ACP (p = 0.73), K2 (p = 0.8), and CEI (p = 0.99) showed no significant changes at the end of the examination period. Uncorrected visual acuity remained unchanged (p = 0.32). However, best-corrected visual acuity changed from 0.21 ± 0.17 to 0.12 ± 0.11 in logMAR scale, but this deviation was not considered significant (p = 0.08). No change was observed in intraocular pressure (p = 0.79). Cornea remained clear and during follow-up period no corneal thinning was observed (p = 0.78). Conclusions Our results suggest that corneal collagen CXL can be a successful treatment at certain stages of keratoconus, offering a way to stop progression in keratometric indices.


Journal of Refractive Surgery | 2015

Repeatability Data and Agreement of Keratometry With the VERION System Compared to the IOLMaster

Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; András Berta; László Módis

PURPOSE To analyze the repeatability of keratometric and white-to-white (WTW) distance measurements with the VERION Measurement Module (Alcon Laboratories, Inc., Fort Worth, TX) and to compare the measured data to the results of the IOLMaster (Carl Zeiss Meditec, Jena, Germany). METHODS Three images were captured with the VERION and the flattest and steepest keratometric data, the astigmatism axis, and the WTW distance were recorded. Subsequently, the axial length, the keratometric data with axis, and the WTW distance were measured with an IOLMaster. The repeatability data of the keratometric value of the VERION System, converted to cross cylinder J0 and J45 vector components, were analyzed. The agreement data for keratometry obtained by the VERION System and the differences regarding keratometric data and WTW distance compared to IOLMaster were calculated. RESULTS The measurements were conducted in 50 eyes of 50 healthy volunteers (median age: 50.32 years, range: 19.34 to 85.3 years). The flattest and the steepest keratometric data, the diopter of astigmatism, the J0 and J45 vector components, and WTW distance did not differ significantly between devices (P > .05). Intraclass correlation coefficients (range: 0.863 to 0.994) and Cronbachs alpha values (range: 0.950 to 0.998) were high for all parameters measured by the VERION System. CONCLUSIONS The VERION System has high repeatability and agreement with the IOLMaster, making it suitable as an alternative tool in clinical practice.


Indian Journal of Ophthalmology | 2014

Collagen cross-linking in the treatment of pellucid marginal degeneration

Ziad Hassan; Gabor Nemeth; László Módis; Eszter Szalai; András Berta

Pellucid marginal degeneration (PMD) is an uncommon cause of inferior peripheral corneal thinning disorder, characterized by irregular astigmatism. We analyzed a case of bilateral PMD patient and treated one eye with corneal collagen cross-linking (CXL) therapy. Corneal topography was characteristic for PMD. Visual acuity, slitlamp examinations, tonometry, and corneal thickness were observed. Simulated keratometric and topographic index values were detected with corneal topography. Uncorrected, LogMAR visual acuity has improved from +0.8 to +0.55 during the 6 months and +0.3 during the 8 months follow-up after CXL. Pachymetry values and intraocular pressure showed no changes. Keratometric values and topografic indexes disclosed no progression of the disease. CXL may postpone or eliminate the need of corneal transplantation in cases with PMD.

Collaboration


Dive into the Ziad Hassan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge