Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A. Clairon is active.

Publication


Featured researches published by A. Clairon.


Physical Review Letters | 2004

New Limits on the Drift of Fundamental Constants from Laboratory Measurements

M. Fischer; Nikolai N. Kolachevsky; Marcus Zimmermann; Ronald Holzwarth; Thomas Udem; T. W. Hänsch; M. Abgrall; J. Grunert; I. Maksimovic; S. Bize; H. Marion; F. Pereira Dos Santos; P. Lemonde; G. Santarelli; P. Laurent; A. Clairon; Christophe Salomon; Martin Haas; Ulrich D. Jentschura; Christoph H. Keitel

We have remeasured the absolute 1S-2S transition frequency nu(H) in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of (-29+/-57) Hz for the drift of nu(H) with respect to the ground state hyperfine splitting nu(Cs) in 133Cs. Combining this result with the recently published optical transition frequency in 199Hg+ against nu(Cs) and a microwave 87Rb and 133Cs clock comparison, we deduce separate limits on alpha/alpha=(-0.9+/-2.9) x 10(-15) yr(-1) and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments mu(Rb)/mu(Cs) equal to (-0.5+/-1.7) x 10(-15) yr(-1). The latter provides information on the temporal behavior of the constant of strong interaction.


Physical Review Letters | 2003

Search for variations of fundamental constants using atomic fountain clocks.

H. Marion; F. Pereira Dos Santos; M. Abgrall; S. Zhang; Y. Sortais; S. Bize; I. Maksimovic; Davide Calonico; J. Grunert; C. Mandache; P. Lemonde; G. Santarelli; Ph. Laurent; A. Clairon; Christophe Salomon

Over five years, we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser-cooled 133Cs and 87Rb atomic fountains with an accuracy of approximately 10(-15). These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies: d/dt ln([(nu(Rb))/(nu(Cs))]=(0.2+/-7.0)x 10(-16) yr(-1) (1sigma uncertainty). The same limit applies to a possible variation of the quantity (mu(Rb)/mu(Cs))alpha(-0.44), which involves the ratio of nuclear magnetic moments and the fine structure constant.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 1998

Frequency stability degradation of an oscillator slaved to a periodically interrogated atomic resonator

G. Santarelli; Claude Audoin; A. Makdissi; P. Laurent; G.J. Dick; A. Clairon

Atomic frequency standards using trapped ions or cold atoms work intrinsically in a pulsed mode. Theoretically and experimentally, this mode of operation has been shown to lead to a degradation of the frequency stability due to the frequency noise of the interrogation oscillator. In this paper a physical analysis of this effect has been made by evaluating the response of a two-level atom to the interrogation oscillator phase noise in Ramsey and multi-Rabi interrogation schemes using a standard quantum mechanical approach. This response is then used to calculate the degradation of the frequency stability of a pulsed atomic frequency standard such as an atomic fountain or an ion trap standard. Comparison is made to an experimental evaluation of this effect in the LPTF Cs fountain frequency standard, showing excellent agreement.


EPL | 1991

Ramsey Resonance in a Zacharias Fountain

A. Clairon; C. Salomon; S Guellati; William D. Phillips

We report a realization of Zachariass 1953 proposal for observing a Ramsey resonance in an atomic fountain. Launched upward from a moving optical molasses where they have been cooled to ~ 5 ?K, cesium atoms pass once through a microwave cavity, continue to the summit of their trajectory, then fall again through the same cavity, completing the separated-fields interaction. The atoms spend 0.25 s in free flight above the cavity. Linewidth (2 Hz) and S/N imply a stability of 3?10-12 ?-1/2, at least as good as in existing Cs clocks, with eventual expected improvements of 102.


Journal of Physics B | 2005

Cold atom clocks and applications

S. Bize; P. Laurent; M. Abgrall; H. Marion; I. Maksimovic; L. Cacciapuoti; J. Grunert; C. Vian; F. Pereira Dos Santos; P. Rosenbusch; P. Lemonde; G. Santarelli; Peter Wolf; A. Clairon; Andre Luiten; Michael E. Tobar; C. Salomon

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the 133Cs and 87Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of 1.6 × 10−14 τ−1/2 where τ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2 × 10−16 at 50 000 s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7 × 10−16, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using 87Rb and 133Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.


Optics Communications | 2006

Interference-filter-stabilized external-cavity diode lasers

X. Baillard; A. Gauguet; S. Bize; P. Lemonde; Ph. Laurent; A. Clairon; P. Rosenbusch

We have developed external cavity diode lasers, where the wavelength selection is assured by a low loss interference filter instead of the common diffraction grating. The filter allows a linear cavity design reducing the sensitivity of the wavelength and the external cavity feedback against misalignment. By separating the feedback and wavelength selection functions, both can be optimized independently leading to an increased tunability of the laser. The design is employed for the generation of laser light at 698, 780 and 852 nm. Its characteristics make it a well suited candidate for space-born lasers.


Physical Review Letters | 2005

Long-distance frequency dissemination with a resolution of 10(-17).

Christophe Daussy; Olivier Lopez; Anne Amy-Klein; Andrei N. Goncharov; Mickael Guinet; Christian Chardonnet; F. Narbonneau; M. Lours; Damien Chambon; S. Bize; A. Clairon; Georgio Santarelli; Michael Edmund Tobar; Andre Luiten

We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10(-17) for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3 x 10(-14) at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1 x 10(-14) at 1 s.


Physical Review Letters | 2006

Six-axis inertial sensor using cold-atom interferometry.

B. Canuel; F. Leduc; David Holleville; A. Gauguet; J. Fils; A. Virdis; A. Clairon; N. Dimarcq; Ch. J. Bordé; Arnaud Landragin; Philippe Bouyer

We have developed an atom interferometer providing a full inertial base. This device uses two counterpropagating cold-atom clouds that are launched in strongly curved parabolic trajectories. Three single Raman beam pairs, pulsed in time, are successively applied in three orthogonal directions leading to the measurement of the three axis of rotation and acceleration. In this purpose, we introduce a new atom gyroscope using a butterfly geometry. We discuss the present sensitivity and the possible improvements.


Physical Review Letters | 2003

Tests of Lorentz invariance using a microwave resonator.

Peter Wolf; S. Bize; A. Clairon; Andre Luiten; G. Santarelli; Michael E. Tobar

The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to delta-beta + 1/2 = (1.5+/-4.2) x 10(-9) and beta-alpha - 1= (-3.1+/-6.9) x 10(-7) which is of the same order as the best previous result for the former and represents a 30-fold improvement for the latter.


conference on precision electromagnetic measurements | 1994

A cesium fountain frequency standard: preliminary results

A. Clairon; Ph. Laurent; G. Santarelli; S. Ghezali; S.N. Lea; M. Bahoura

Laser cooling of atoms has opened up new possibilities in the field of atomic frequency standards. A cesium atomic fountain, first proposed by Zacharias in 1953, is now feasible: the atoms, first cooled by six laser beams, are launched upward using laser light, pass once through a microwave cavity, continue their ballistic flight and then fall through the same cavity. The long time between the two microwave interactions leads to a Ramsey resonance much narrower than in conventional Cs clocks using thermal atomic beams. The stability and accuracy of such a cesium fountain are very attractive. The use of diode lasers to cool, launch and detect cesium atoms in a low cesium pressure cell allows the construction of a simple and reliable atomic fountain frequency standard. A fountain frequency standard is now in operation at LPTF. A Ramsey resonance as narrow as 0.8 Hz has been obtained. A few days of continuous operation are routinely obtained. In closed loop operation the fountain frequency standard is continuously monitored against a H maser allowing an evaluation of the accuracy of the device. The short-term frequency stability is about 5.10/sup -13/ /spl tau//sup - 1/2 / limited only by the frequency noise of the microwave source. We intend to present a preliminary evaluation of this new standard with a discussion of the major systematic effects which determine the accuracy. The expected accuracy is expected to be at 10/sup -14/ level. In addition, a description of the whole design of the cesium fountain is presented. >

Collaboration


Dive into the A. Clairon's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

S. Bize

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

P. Lemonde

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

C. Salomon

École Normale Supérieure

View shared research outputs
Top Co-Authors

Avatar

N. Dimarcq

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

Michael E. Tobar

University of Western Australia

View shared research outputs
Top Co-Authors

Avatar

P. Rosenbusch

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

Arnaud Landragin

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

M. Abgrall

PSL Research University

View shared research outputs
Top Co-Authors

Avatar

O. Acef

Centre national de la recherche scientifique

View shared research outputs
Researchain Logo
Decentralizing Knowledge