A. Rodrigues
CERN
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by A. Rodrigues.
nuclear science symposium and medical imaging conference | 2012
D. Abbaneo; M. Abbrescia; C. Armagnaud; P. Aspell; Y. Assran; Y. Ban; S. Bally; L. Benussi; U. Berzano; S. Bianco; Jelte E. Bos; K. Bunkowski; J. Cai; J. P. Chatelain; J. Christiansen; S. Colafranceschi; A. Colaleo; A. Conde Garcia; E. David; G. De Robertis; R. De Oliveira; S. Duarte Pinto; S. Ferry; F. Formenti; L. Franconi; T. Fruboes; A. Gutierrez; M. Hohlmann; Ali Ellithi Kamel; P. E. Karchin
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5 <; |η| <; 2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-η region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance results from the beam test. We also tested smaller Triple-GEM prototypes with zigzag readout strips with 2 mm pitch in these beams and measured a spatial resolution of 73 μm. This readout offers a potential reduction of channel count and consequently electronics cost for this system while maintaining high spatial resolution.
Journal of Instrumentation | 2013
D. Abbaneo; M. Abbrescia; M. Abi Akl; C Armaingaud; P. Aspell; Y. Assran; S. Bally; Y. Ban; P. Barria; L. Benussi; V. Bhopatkar; S. Bianco; Jelte E. Bos; O. Bouhali; J. Cai; Cesare Calabria; A. Castaneda; S. Cauwenbergh; Ali Celik; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; G. De Lentdecker; R. De Oliveira; G. De Robertis; S. Dildick; S. Ferry; W. Flanagan; J. Gilmore
The CMS GEM collaboration is performing a feasibility study to install triple-GEM detectors in the forward region of the muon system (1.6 < vertical bar eta vertical bar < 2.4) of the CMS detector at the LHC. Such micro-pattern gas detectors are able to cope with the extreme particle rates that are expected in that region during the High Luminosity phase of the LHC. With their spatial resolution of order 100 micron GEMs would not only provide additional benefits in the CMS muon High Level Trigger, but also in the muon identification and track reconstruction, effectively combining tracking and triggering capabilities in one single device. The present status of the full project will be reviewed, highlighting all importants steps and achievements since the start of the R& D in 2009. Several small and full-size prototypes were constructed with different geometries and techniques. The baseline design of the triple-GEM detector for CMS will be described, along with the results from extensive test measurements of all prototypes both in the lab and in test beams at the CERN SPS. The proposed on-and off-detector electronics for the final system will be presented.
Journal of Instrumentation | 2014
D. Abbaneo; M. Abbrescia; M. Abi Akl; W. Ahmed; C Armaingaud; P. Aspell; Y. Assran; S. Bally; Y. Ban; S. Banerjee; P. Barria; L. Benussi; V. Bhopatkar; S. Bianco; Jelte E. Bos; O. Bouhali; J. Cai; Cesare Calabria; A. Castaneda; S. Cauwenbergh; Ali Celik; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; M. M. Dabrowski; G. De Lentdecker; R. De Oliveira; G. De Robertis; S. Dildick
In this contribution we will report on the progress of the design of the readout and data acquisition system being developed for triple-GEM detectors which will be installed in the forward region (1.5 < |?| < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, expected in the period 2017?2018. The system will be designed to take full advantage of current generic developments introduced for the LHC upgrades. The current design is based on the use of CERN GLIB boards hosted in micro-TCA crates for the off-detector electronics and the Versatile Link with the GBT chipset to link the front-end electronics to the GLIB boards. In this contribution we will describe the physics goals, the hardware architectures and report on the expected performance of the CMS GEM readout system, including preliminary timing resolution simulations.
Journal of Instrumentation | 2014
D. Abbaneo; M. Abbrescia; M. Abi Akl; C Armaingaud; P. Aspell; Y. Assran; S. Bally; Y. Ban; S. Banerjee; P. Barria; L. Benussi; V. Bhopatkar; S. Bianco; Jelte E. Bos; O. Bouhali; J. Cai; Cesare Calabria; M. Caponero; A. Castaneda; S. Cauwenbergh; Ali Celik; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; G. De Lentdecker; R. De Oliveira; G. De Robertis; S. Dildick; M. Ferrini
During the next shutdown of the LHC at CERN, the CMS experiment plans to start installing GEM detectors in the endcap (high pseudorapidity) region. These muon detectors have excellent spatial and temporal resolution as well as a high chemical stability and radiation hardness. A report is given on preliminary results of materials studies that aimed to fully characterize the GEM detector components before and after the exposure to a high-radiation environment.
Journal of Instrumentation | 2014
D. Abbaneo; M. Abbrescia; M. Abi Akl; C Armaingaud; P. Aspell; Y. Assran; S. Bally; Y. Ban; S. Banerjee; P. Barria; L. Benussi; V. Bhopatkar; S. Bianco; Jelte E. Bos; O. Bouhali; J. Cai; Cesare Calabria; A. Castaneda; S. Cauwenbergh; Ali Celik; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; G. De Lentdecker; R. De Oliveira; G. De Robertis; S. Dildick; S. Ferry; W. Flanagan
The LHC data-taking will resume in 2015 with energy of 13-14 TeV and luminosity of 2 divided by 5 x 10(34) cm(-2) s(-1). At those energies, a considerable fraction of the particles produced propagate in the high pseudo-rapidity regions. The proposal for the upgrade of the CMS muon forward system involves Gas Electron Multiplier (GEM) chambers to be installed during the second LHC Long Shutdown (LS2) covering the pseudorapidity range 1 : 5 < vertical bar h vertical bar < 2.2. This detector is able to handle the extreme particle rates expected in this region when the LHC will be running at higher luminosity. The GEM is an excellent choice, as its high spatial resolution (order of 100 m m) allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs, discussing also the trigger performance.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2013
D. Abbaneo; C. Armagnaud; M. Abbrescia; P. Aspell; S. Bally; Y. Ban; L. Benussi; U. Berzano; S. Bianco; Jelte E. Bos; K. Bunkowski; J. Cai; J. P. Chatelain; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; E. David; R. De Oliveira; G. De Robertis; G. De Lentdecker; S. Duarte Pinto; S. Ferry; F. Formenti; L. Franconi; T. Fruboes; Kondo Gnanvo; A. Gutierrez; Y. Yang; M. Hohlmann
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2013
D. Abbaneo; M. Abbrescia; C. Armagnaud; P. Aspell; Y. Assran; Y. Ban; S. Bally; P. Barria; L. Benussi; U. Berzano; S. Bianco; Jelte E. Bos; K. Bunkowski; J. Cai; J. P. Chatelain; J. Christiansen; S. Colafranceschi; Anna Colaleo; A. Conde Garcia; E. David; G. De Robertis; G. De Lentdecker; R. De Oliveira; S. Duarte Pinto; S. Ferry; F. Formenti; L. Franconi; T. Fruboes; A. Gutierrez; M. Hohlmann
13th International Conference on Advanced Technology and Particle Physics, ICATPP 2011 | 2012
M. Abbrescia; Anna Colaleo; G. De Robertis; F. Loddo; Marcello Maggi; S. Nuzzo; S. A. Thpputi; Y. Ban; J. Cai; H. Teng; A. Mohapatra; T. Moulik; Aitor Gutierrez; P. E. Karchin; L. Benussi; S. Bianco; S. Colafranceschi; D. Piccolo; G. Raffone; G. Saviano; D. Abbaneo; P. Aspell; S. Bally; Jelte E. Bos; J. P. Chatelain; J. Christiansen; A. Conde Garcia; E. David; R. De Oliveira; S. Duarte Pinto
International Conference on Advanced Technology and Particle Physics | 2014
D. Abbaneo; M. Abbrescia; M. Abi Akl; C Armaingaud; P. Aspell; Y. Assran; S. Bally; Y. Ban; S. Banerjee; P. Barria; L. Benussi; V. Bhopatkar; S. Bianco; Jelte E. Bos; O. Bouhali; J. Cai; C. Calabria; A. Castaneda; S. Cauwenbergh; Ali Celik; J. Christiansen; S. Colafranceschi; A. Colaleo; A. Conde Garcia; G. De Lentdecker; R. De Oliveira; G De Robertis; S. Dildick; S. Ferry; W. Flanagan
arXiv: Instrumentation and Detectors | 2013
A. Castaneda; M. Abi Akl; G. De Lentdecker; R. Radogna; C Armaingaud; S. Ferry; G. Saviano; S. Dildick; E. Verhagen; D. Piccolo; Jelte E. Bos; A. Tatarinov; J. Twigger; F. Zenoni; A. Marchioro; T. Kamon; M. Van Stenis; M. Tytgat; P. Aspell; Jeremie Alexandre Merlin; P. E. Karchin; E. Oliveri; A. Gutierrez; M. Hohlmann; J. Gilmore; K. Hoepfner; V. Bhopatkar; H. Postema; G. Raffone; O. Bouhali