A. S. Chernenko
Kurchatov Institute
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by A. S. Chernenko.
Surface Review and Letters | 2002
L. Juha; J. Krása; A. Präg; Andrea Cejnarova; Dagmar Chvostova; K. Rohlena; K. Jungwirth; J. Kravarik; P. Kubes; Yu. L. Bakshaev; A. S. Chernenko; V. D. Korolev; V. I. Tumanov; M. I. Tumanov; A. Bernardinello; J. Ullschmied; F. P. Boody
The efficiency of ablation induced in poly(methyl methacrylate) (PMMA) by single soft X-ray pulses emitted from Z-pinch and laser-produced plasmas was determined. X-ray ablation of PMMA was found to be less efficient than that of teflon (PTFE). Nonthermal effects of the radiation on the polymer structure play a key role in the mechanisms of the ablation, i.e. the ablation can be explained by the formation of radiation-chemical scissions of the polymer chain followed by blowoff of low-molecular fragment fluid into the vacuum. The most promising application of this phenomenon seems to be micropatterning/micromachining.
Plasma Physics Reports | 2007
Yu. L. Bakshaev; A. Bartov; P. I. Blinov; A. S. Chernenko; S. A. Dan’ko; Yu. G. Kalinin; A. S. Kingsep; V. D. Korolev; V. I. Mizhiritskiĭ; V. P. Smirnov; A. Yu. Shashkov; P. V. Sasorov; S. I. Tkachenko
A series of experiments was carried out in the S-300 facility (3 MA, 0.15 Θ, 100 ns) to study the behavior of a section of a magnetically insulated transmission line (MITL) at current densities of up to 500 MA/cm2 and linear current densities of up to 6 MA/cm (i.e., at parameters close to those expected in a fast Z-pinch fusion reactor projected in Sandia National Laboratories). The surface explosion of the ohmically heated MITL electrode is accompanied by the formation of a plasma layer on its surface. This can deteriorate of the transmission properties of the line because the vacuum gap is short-circuited by the plasma produced. The parameters of the electrode plasma and its effect on the MITL transmission properties were investigated experimentally. Possible consequences of the above effects are evaluated, and MHD simulations of the electrode explosion and the subsequent spread of the plasma layer are performed. It is shown that the time during which an MITL segment preserves its transmission properties conforms to the requirements of the conceptual fusion reactor.
IEEE Transactions on Plasma Science | 2009
D. Klir; Jozef Kravarik; P. Kubes; K. Rezac; Sergey S. Ananev; Yuriy L. Bakshaev; Peter I. Blinov; A. S. Chernenko; Evgeny D. Kazakov; V. D. Korolev; Gennadiy I. Ustroev; L. Juha; J. Krása; A. Velyhan
The implosion of a solid deuterium gas-puff Z-pinch was studied on the S-300 pulsed power generator [A. S. Chernenko, , Proceedings of 11th Int. Conf. on High Power Particle Beams, 154 (1996)]. The peak neutron yield above 1010 was achieved on the current level of 2 MA. The fusion neutrons were generated at about 150 ns after the current onset, i.e., during the stagnation and at the beginning of the expansion of a plasma column. The neutron emission lasted on average 25 ns. The neutron energy distribution function was reconstructed from 12 neutron time-of-flight signals by the Monte Carlo simulation. The side-on neutron energy spectra peaked at 2.42 plusmn 0.04 MeV with about 450-keV FWHM. In the downstream direction (i.e., the direction of the current flow from the anode toward the cathode), the peak neutron energy and the width of a neutron spectrum were 2.6 plusmn 0.1 MeV and 400 keV, respectively. The average kinetic energy of fast deuterons, which produced fusion neutrons, was about 100 keV. The generalized beam-target model probably fits best to the obtained experimental data.
Plasma Physics Reports | 2006
Yu. G. Kalinin; A. S. Kingsep; V. P. Smirnov; Yu. L. Bakshaev; A. Bartov; P. I. Blinov; S. A. Dan’ko; Leonid G. Dubas; A. V. Korel’skiĭ; V. D. Korolev; V. I. Mizhiritskiĭ; G. I. Ustroev; A. S. Chernenko; R.V. Chikin; A. Yu. Shashkov; Li Zheng-Hong; Hua Xinsheng; Peng Xianjue; Feng Shupin; Guo Cun; Jiang Shi-Lun; Ning Cheng; Song Feng-Jun; Xu Rong-Kun; Xu Ze-Ping; Yan Chengli; Yang Jian-Lun
Results are presented from experiments on the implosion of simple and nested wire arrays of different mass and material composition (W and/or Al). The experiments were performed on the S-300 facility (a high-current pulsed power generator with a voltage pulse amplitude of 700 kV, current amplitude of 2.5–3.5 MA, and pulse duration of 100 ns) at the Kurchatov Institute (Moscow). The imploding arrays were recorded using five-frame laser shadowgraphy, three-frame image-tube photography, an optical streak camera, X-ray pinhole cameras with different filters, X-ray polychromator, and X-ray spectrometer on the basis of a convex mica crystal. Laser probing measurements indicate that the current-carrying structure undergoes a fast (over a time shorter than 10 ns) global rearrangement, which manifests itself as the emergence of transparent regions. This effect is presumably related to the grouping of the wires, which carry currents of a few tens of kiloamperes, or to the current filamentation in their common plasma corona. The radiation of liners of different chemical composition in the final compressed state has been investigated. Electric measurements performed in experiments with nested arrays (e.g., with an aluminum outer liner and a tungsten inner liner) indicate that the inner array, which is still at rest, intercepts the electric current from the outer array when the latter penetrates through it. The effect of the “fall” of the outer liner through the inner one in the course of magnetic implosion has been revealed for the first time by analyzing X-ray emission spectra.
Plasma Physics and Controlled Fusion | 2010
D. Klir; J. Kravarik; P. Kubes; K. Rezac; J. Cikhardt; E Litseva; T Hyhlik; S. Anan'ev; Yu. L. Bakshaev; V. A. Bryzgunov; A. S. Chernenko; Yu. G. Kalinin; E. D. Kazakov; V. D. Korolev; G. I. Ustroev; A. A. Zelenin; L. Juha; J. Krása; A. Velyhan; L Vysin; J Sonsky; I. V. Volobuev
Deuterium gas puff experiments were carried out on the S-300 Z-pinch at the Kurchatov Institute in Moscow. Gas puffs imploded onto the axis before a current peak at about 100 ns. Fusion neutrons were generated after the gas puff implosion during global expansion of a plasma column. Neutron emission lasted on average 35 ± 5 ns (full width half maximum, FWHM). In the downstream direction (on the Z-pinch axis behind the cathode), a mean neutron energy was 2.6 ± 0.1 MeV. Side-on neutron energy spectra peaked at 2.40 ± 0.05 MeV with about 600 ± 150 keV FWHM. A broad width of side-on neutron spectra implied a high radial component of deuteron velocities. An average kinetic energy of fast deuterons, which produced fusion neutrons, was 150 keV. A peak neutron yield reached a value of 6 × 1010 on a current level of 1.5 MA. It was by one order higher in comparison with other deuterated loads used on the same current generator. On the basis of experimental observations, we concluded that a total energy of deuterons accelerated to fusion energies was above 1.5 kJ. It is more than 15% of the energy input into a plasma. Therefore gas puff Z-pinches seem to be not only powerful sources of x-ray radiation but also efficient sources of 100 keV deuterons. Such a result is consistent with high neutron yields observed on the Angara Z-pinch and plasma foci with similar currents.
Physics of Plasmas | 2008
D. Klir; J. Kravarik; P. Kubes; K. Rezac; S. S. Anan’ev; Yu. L. Bakshaev; P. I. Blinov; A. S. Chernenko; E. D. Kazakov; V. D. Korolev; B. R. Meshcherov; G. I. Ustroev; L. Juha; J. Krása; A. Velyhan
The implosion of both cylindrical and conical wire arrays onto a deuterated polyethylene fiber was studied on the S-300 pulsed power generator [A. S. Chernenko et al., Proceedings of the 11th International Conference on High Power Particle Beams (Academy of Science of Czech Republic, Prague, 1996), p. 154]. Neutron measurements were used to obtain information about acceleration of fast deuterons. An average neutron yield approached 109 on the current level of 2MA. In the case of conical wire arrays, side-on neutron energy spectra peaked at 2.48±0.05MeV with 450±100keV full width at half-maximum. In the downstream direction, the peak neutron energy and the width of a neutron spectrum were 2.65±0.10MeV and 350±100keV, respectively. The total number of fast deuterons was 1015 and their average kinetic energy was about 150keV. Most of the deuterons were directed toward the cathode. The broad width of neutron spectra in the side-on direction implied a high radial component of deuteron velocity. With regard to ...
Plasma Physics Reports | 2001
Yu. L. Bakshaev; P. I. Blinov; V. V. Vikhrev; E. M. Gordeev; S. A. Dan’ko; V. D. Korolev; S. F. Medovshchikov; S. L. Nedoseev; E. A. Smirnova; V. I. Tumanov; A. S. Chernenko; A. Yu. Shashkov
The development of a preformed constriction in cylindrical agar-agar loads at currents of up to 3 MA is studied experimentally. The loads 3–5 mm in diameter have a mass density of 0.1 g/cm3 and are filled with different materials. Due to the implosion of the constriction to a minimum size of 40–70 µm, a hot dense plasma (with the electron density ne=1022 cm−3, electron temperature Te=0.8–1.5 keV, and ion temperature Ti=3–12 keV) is produced. It is found that the ion temperature substantially exceeds the electron temperature. The lifetime of the high-temperature plasma determined from the FWHM of a soft X radiation (SXR) pulse is shorter than 5 ns, the radiation power of photons with energies of ≥1 keV is higher than 0.5×1010 W, and their total energy attains 50 J. High-speed photography in the VUV, SXR, and optical spectral regions indicates the protracted generation of the high-temperature plasma. Calculations by the two-dimensional ideal MHD model of the Z-pinch show that the most important consequence of the protracted plasma generation in the constriction region is that the current is intercepted by a freshly produced plasma. In the course of plasma generation, the current near the axis inside the region of radius 50 µm is at most one-half of the total current. After the plasma generation comes to an end, almost the entire current is concentrated in this region for several nanoseconds; this process is accompanied by a sharp increase in the plasma temperature.
Jetp Letters | 2008
S. S. Anan’ev; Yu. L. Bakshaev; P. I. Blinov; V. A. Bryzgunov; S. A. Dan’ko; A. I. Zhuzhunashvili; A. A. Zelenin; E. D. Kazakov; Yu. G. Kalinin; A. S. Kingsep; V. D. Korolev; V. I. Mizhiritskiĭ; Sergey A. Pikuz; Vera M. Romanova; V. P. Smirnov; S. I. Tkachenko; G. I. Ustroev; A. S. Chernenko; T. A. Shelkovenko; V. A. Shchagin
The results of experimental investigations into the dynamics of a plasma produced in the multiwire X pinch at currents up to 2.3 MA are presented. The materials, diameters, and the number of wires are varied. At such currents, the power of the soft x-ray radiation with the photon energy from 1 to 2 keV increases to 120 GW, and, since the size of a hot spot is less than 20 μm, it corresponds to a source brightness of ∼1015 W/(cm2 sr). The energy recorded in lines of neon-like molybdenum (in the range of 2.5–3 keV) is higher than 10 J. Hard x-ray radiation detected in experiments with tungsten and molybdenum X pinches has the photon energy ≥800 keV.
Plasma Physics Reports | 2008
S. S. Anan’ev; Yu. L. Bakshaev; A. Bartov; P. I. Blinov; S. A. Dan’ko; A. I. Zhuzhunashvili; E. D. Kazakov; Yu. G. Kalinin; A. S. Kingsep; V. D. Korolev; V. I. Mizhiritskii; V. P. Smirnov; S. I. Tkachenko; A. S. Chernenko
Results are presented from experimental studies of a section of a magnetically insulated transmission line (MITL) with a current density of up to 500 MA/cm2 and linear current density of up to 7 MA/cm (the parameters close to those in a fast-Z-pinch-driven fusion reactor projected at Sandia Laboratories). The experiments were performed in the S-300 facility (3 MA, 0.15 Ω, 100 ns). At high linear current densities, the surface of the ohmically heated MITL electrode can explode and a plasma layer can form near the electrode surface. As a result, the MITL can lose its transmission properties due to the shunting of the vacuum gap by the plasma produced. In this series of experiments, the dynamics of the electrode plasma and the dependence of the transmission properties of the MITL on the material and cleanness of the electrode surface were studied. It is shown experimentally that, when the current with a linear density of up to 7 MA/cm begins to flow along a model MITL, the input and output currents differ by less than 10% over a time interval of up to 230 ns for nickel electrodes and up to 350 ns for a line with a gold central electrode. No effect of the oil film present on the electrode surface on the loss of the transmission properties of the line was observed. It is also shown that electron losses insignificantly contribute to the total current balance. The experimental results are compared with calculations of the electrode explosion and the subsequent expansion of the plasma layer. A conclusion is made that the life-time of the model MITL satisfies the requirements imposed on the transmission lines intended for use in the projected thermonuclear reactor.
Review of Scientific Instruments | 2001
Yu. L. Bakshaev; P. I. Blinov; A. S. Chernenko; S. A. Dan’ko; Yu. G. Kalinin; V. D. Korolev; V. I. Tumanov; A. Yu. Shashkov; A. V. Chesnokov; M. I. Ivanov
A set of experiments on neutron and x-ray generation was performed on the S-300 facility for the last few months. The S-300 facility is a pulse generator with electric current achieving 3.5 MA, voltage 400–500 kV, and rise time ∼100 ns. (Chernenko et al., Proc. of the 11th International Conference of Power Particle Beams, Prague, 1966, p. 154). It is designed as van eight-module machine transmitting electromagnetic power to the low-inductive load through the vacuum line with self-magnetic isolation. Diagnostic techniques and methods on S-300 used are described in this article. Ten-channel polychromator is used for the soft x-ray and vacuum ultraviolet bands (50–500 eV) measurements with spectral resolution of 5%–20% and time resolution less than 2.5 ns. Radiated power measurements in the region of 0.1–10 keV are performed by vacuum x-ray diodes and semiconductor detectors equipped with different filters. Curved crystal x-ray spectrography is intended for plasma density, electron, and ion temperature evalu...