Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A.S. Howard is active.

Publication


Featured researches published by A.S. Howard.


Physical Review D | 2009

Results from the first science run of the ZEPLIN-III dark matter search experiment

V. N. Lebedenko; H.M. Araújo; E. J. Barnes; A. Bewick; R. Cashmore; V. Chepel; A. Currie; D. Davidge; J. Dawson; T. Durkin; B. Edwards; C. Ghag; M. Horn; A.S. Howard; A. J. Hughes; W.G. Jones; M. Joshi; G. Kalmus; A.G. Kovalenko; A. Lindote; I. Liubarsky; M.I. Lopes; R. Lüscher; P. Majewski; A. St. J. Murphy; F. Neves; J. Pinto da Cunha; R. Preece; J. J. Quenby; P.R. Scovell

The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12 kg two-phase xenon time-projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionization produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected from WIMPs and the electron-recoil background signals down to {approx}10 keV nuclear-recoil energy. An analysis of 847 kg{center_dot}days of data acquired between February 27, 2008, and May 20, 2008, has excluded a WIMP-nucleon elastic scattering spin-independent cross section above 8.1x10{sup -8} pb at 60 GeVc{sup -2} with a 90% confidence limit. It has also demonstrated that the two-phase xenon technique is capable of better discrimination between electron and nuclear recoils at low-energy than previously achieved by other xenon-based experiments.


Astroparticle Physics | 2007

The ZEPLIN-III dark matter detector: Instrument design, manufacture and commissioning

D. Yu. Akimov; G. J. Alner; H.M. Araújo; A. Bewick; C. Bungau; A. A. Burenkov; M.J. Carson; H. Chagani; V. Chepel; D. Cline; D. Davidge; E. Daw; J. Dawson; T. Durkin; B. Edwards; T. Gamble; C. Chag; R. Hollingworth; A.S. Howard; W.G. Jones; M. Joshi; K. Mavrokoridis; E.V. Korolkova; A. G. Kovalenko; V.A. Kudryavtsev; I. S. Kuznetsov; T.B. Lawson; V. N. Lebedenko; J.D. Lewin; P. K. Lightfoot

We present details of the technical design, manufacture and testing of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.


Physics Letters B | 2005

Limits on WIMP cross-sections from the NAIAD experiment at the Boulby Underground Laboratory

G. J. Alner; H.M. Araújo; G. Arnison; J. C. Barton; A. Bewick; C. Bungau; B. Camanzi; M.J. Carson; D. Davidge; Gavin Davies; J.C. Davies; E. Daw; J. Dawson; Christopher D. P. Duffy; T. Durkin; T. Gamble; S.P. Hart; R. Hollingworth; G.J. Homer; A.S. Howard; I. Ivaniouchenkov; W.G. Jones; M. Joshi; J. Kirkpatrick; V.A. Kudryavtsev; T.B. Lawson; V. N. Lebedenko; M J Lehner; J.D. Lewin; P. K. Lightfoot

The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at the Boulby Underground Laboratory (North Yorkshire, UK) ran from 2000 until 2003. A total of 44.9 kg x years of data collected with 2 encapsulated and 4 unencapsulated NaI(Tl) crystals with high light yield were included in the analysis. We present final results of this analysis carried out using pulse shape discrimination. No signal associated with nuclear recoils from WIMP interactions was observed in any run with any crystal. This allowed us to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. The NAIAD experiment has so far imposed the most stringent constraints on the spin-dependent WIMP-proton cross-section.


Physical Review Letters | 2009

Limits on the Spin-Dependent WIMP-Nucleon Cross Sections from the First Science Run of the ZEPLIN-III Experiment

V. N. Lebedenko; H.M. Araújo; E. J. Barnes; A. Bewick; R. Cashmore; V. Chepel; A. Currie; D. Davidge; J. Dawson; T. Durkin; B. Edwards; C. Ghag; M. Horn; A.S. Howard; A. J. Hughes; W.G. Jones; M. Joshi; G. Kalmus; A.G. Kovalenko; A. Lindote; I. Liubarsky; M.I. Lopes; R. Lüscher; K. Lyons; P. Majewski; A. St. J. Murphy; F. Neves; J. Pinto da Cunha; R. Preece; J. J. Quenby

We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter weakly interacting massive particles based at the Boulby mine. Analysis of approximately 450 kg x days fiducial exposure allow us to place a 90%-confidence upper limit on the pure WIMP-neutron cross section of sigma(n)=1.9x10(-2) pb at 55 GeV/c(2) WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn charge-dependent nucleon-nucleon potential were used for the odd-neutron isotopes 129Xe and 131Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction could be much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of approximately 2.


Applied Physics Letters | 2002

Table-top neutron source for characterization and calibration of dark matter detectors

F. N. Beg; K. Krushelnick; C. Gower; S. Torn; A. E. Dangor; A.S. Howard; T. J. Sumner; A. Bewick; V. N. Lebedenko; J. Dawson; D. Davidge; M. Joshi; J. R. Gillespie

A table-top plasma focus device is shown to be an ideal neutron source for the calibration and characterization of dark matter detectors and has been optimized to produce a maximum yield of 2.0310 7 neutrons per shot. The interaction of energetic neutrons is similar to that expected from weakly interacting massive particles ~WIMPs!—a favored candidate for the dominant component of dark matter in the universe. The weak interaction of a neutron with liquid xenon gas was measured in a prototype xenon two-phase detector. We have developed a detector system in which both the primary scintillation and ionization from the initial interaction can be detected. Both measurements are critical for identifying WIMP’s.


Physics Letters B | 2010

Limits on inelastic dark matter from ZEPLIN-III

D. Yu. Akimov; H.M. Araújo; E. J. Barnes; V. A. Belov; A. Bewick; A. Burenkov; R. Cashmore; V. Chepel; A. Currie; D. Davidge; J. Dawson; T. Durkin; B. Edwards; C. Ghag; A. Hollingsworth; M. Horn; A.S. Howard; A.J. Hughes; W.G. Jones; G. Kalmus; A. S. Kobyakin; A.G. Kovalenko; V. N. Lebedenko; A. Lindote; I. Liubarsky; M.I. Lopes; R. Lüscher; K. Lyons; P. Majewski; A. St. J. Murphy

Abstract We present limits on the WIMP–nucleon cross section for inelastic dark matter from a reanalysis of the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg day in the range 20– 80 keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17 ton yr DAMA modulation signal is allowed at 90% CL: it is in the mass range 45– 60 GeV c − 2 with a minimum CL of 87%, again derived from the maximum patch. This is the tightest constraint yet presented using xenon, a target nucleus whose similarity to iodine mitigiates systematic error from the assumed halo.


Astroparticle Physics | 2006

The ZEPLIN-III dark matter detector: Performance study using an end-to-end simulation tool

H.M. Araújo; D. Yu. Akimov; G. J. Alner; A. Bewick; C. Bungau; B. Camanzi; M.J. Carson; V. Chepel; H. Chagani; D. Davidge; J.C. Davies; E. Daw; J. Dawson; T. Durkin; B. Edwards; T. Gamble; C. Ghag; R. Hollingworth; A.S. Howard; W.G. Jones; M. Joshi; J. Kirkpatrick; A. G. Kovalenko; V.A. Kudryavtsev; V. N. Lebedenko; T.B. Lawson; J.D. Lewin; P. K. Lightfoot; A. Lindote; I. Liubarsky

We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times 10−8 pb to the WIMP-nucleon cross-section.


Physics Reports | 1998

Dark matter experiments at the UK Boulby Mine UK Dark Matter Collaboration

P.F. Smith; N.J.T. Smith; J.D. Lewin; G.J. Homer; G. J. Alner; G. Arnison; J. J. Quenby; T. J. Sumner; A. Bewick; Tarig Ali; B. Ahmed; A.S. Howard; D. Davidge; M. Joshi; W. G. Jones; G. Davies; I. Liubarsky; R.A.D Smith; N.J.C. Spooner; J.W. Roberts; D. R. Tovey; M J Lehner; J.E. McMillan; C.D. Peak; V.A Kudryatsev; Jerome C. Barton

Abstract The current status is summarised of dark matter searches at the UK Boulby Mine based on pulse shape discrimination in NaI, together with further plans for international collaboration on detectors based on nuclear recoil discrimination in liquid and gaseous xenon.


Physics Letters B | 2007

Limits on spin-dependent WIMP-nucleon cross-sections from the first ZEPLIN-II data

G. J. Alner; H.M. Araújo; A. Bewick; C. Bungau; B. Camanzi; M.J. Carson; R. Cashmore; H. Chagani; V. Chepel; D. Cline; D. Davidge; J.C. Davies; E. Daw; J. Dawson; T. Durkin; B. Edwards; T. Gamble; J. Gao; C. Ghag; A.S. Howard; W.G. Jones; M. Joshi; E.V. Korolkova; V.A. Kudryavtsev; T.B. Lawson; V. N. Lebedenko; J.D. Lewin; P. K. Lightfoot; A. Lindote; I. Liubarsky

The first underground data run of the ZEPLIN-II experiment has set a limit on the nuclear recoil rate in the two-phase xenon detector for direct dark matter searches. In this Letter the results from this run are converted into the limits on spin-dependent WIMP-proton and WIMP-neutron cross-sections. The minimum of the curve for WIMP-neutron cross-section corresponds to 7 × 10−2 pb at a WIMP mass of around 65 GeV.


Astroparticle Physics | 2002

Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches

V.A. Kudryavtsev; N.J.C. Spooner; P. K. Lightfoot; J.W. Roberts; M.J Lehner; T. Gamble; M.J. Carson; T.B Lawson; R. Lüscher; J.E. McMillan; B. Morgan; S. M. Paling; M. Robinson; D. R. Tovey; N.J.T. Smith; P.F. Smith; G. J. Alner; S.P. Hart; J.D. Lewin; R. Preece; T. J. Sumner; W. G. Jones; J. J. Quenby; B. Ahmed; A. Bewick; D. Davidge; J. Dawson; A.S. Howard; I. Ivaniouchenkov; M. Joshi

Abstract The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.

Collaboration


Dive into the A.S. Howard's collaboration.

Top Co-Authors

Avatar

A. Bewick

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

D. Davidge

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

J. Dawson

Imperial College London

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Joshi

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

I. Liubarsky

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

W.G. Jones

Imperial College London

View shared research outputs
Top Co-Authors

Avatar

G. J. Alner

Rutherford Appleton Laboratory

View shared research outputs
Top Co-Authors

Avatar

H.M. Araújo

Imperial College London

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge