Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A. Salarian is active.

Publication


Featured researches published by A. Salarian.


IEEE Transactions on Biomedical Engineering | 2004

Gait assessment in Parkinson's disease: toward an ambulatory system for long-term monitoring

A. Salarian; H. Russmann; François Vingerhoets; Catherine Dehollain; Y. Blanc; Pierre Burkhard; Kamiar Aminian

An ambulatory gait analysis method using body-attached gyroscopes to estimate spatio-temporal parameters of gait has been proposed and validated against a reference system for normal and pathologic gait. Later, ten Parkinsons disease (PD) patients with subthalamic nucleus deep brain stimulation (STN-DBS) implantation participated in gait measurements using our device. They walked one to three times on a 20-m walkway. Patients did the test twice: once STN-DBS was ON and once 180 min after turning it OFF. A group of ten age-matched normal subjects were also measured as controls. For each gait cycle, spatio-temporal parameters such as stride length (SL), stride velocity (SV), stance (ST), double support (DS), and gait cycle time (GC) were calculated. We found that PD patients had significantly different gait parameters comparing to controls. They had 52% less SV, 60% less SL, and 40% longer GC. Also they had significantly longer ST and DS (11% and 59% more, respectively) than controls. STN-DBS significantly improved gait parameters. During the stim ON period, PD patients had 31% faster SV, 26% longer SL, 6% shorter ST, and 26% shorter DS. GC, however, was not significantly different. Some of the gait parameters had high correlation with Unified Parkinsons Disease Rating Scale (UPDRS) subscores including SL with a significant correlation (r=-0.90) with UPDRS gait subscore. We concluded that our method provides a simple yet effective way of ambulatory gait analysis in PD patients with results confirming those obtained from much more complex and expensive methods used in gait labs.


IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2010

iTUG, a Sensitive and Reliable Measure of Mobility

A. Salarian; Fay B. Horak; Cris Zampieri; Patricia Carlson-Kuhta; John G. Nutt; Kamiar Aminian

Timed Up and Go (TUG) test is a widely used clinical paradigm to evaluate balance and mobility. Although TUG includes several complex subcomponents, namely: sit-to-stand, gait, 180° turn, and turn-to-sit; the only outcome is the total time to perform the task. We have proposed an instrumented TUG, called iTUG, using portable inertial sensors to improve TUG in several ways: automatic detection and separation of subcomponents, detailed analysis of each one of them and a higher sensitivity than TUG. Twelve subjects in early stages of Parkinsons disease (PD) and 12 age matched control subjects were enrolled. Stopwatch measurements did not show a significant difference between the two groups. The iTUG, however, showed a significant difference in cadence between early PD and control subjects (111.1 ± 6.2 versus 120.4 ± 7.6 step/min, p <; 0.006) as well as in angular velocity of arm-swing (123 ± 32.0 versus 174.0 ± 50.4°/s, p <; 0.005), turning duration (2.18 ± 0.43 versus 1.79 ± 0.27 s, p <; 0.023), and time to perform turn-to-sits (2.96 ± 0.68 versus 2.40 ± 0.33 s, p <; 0.023). By repeating the tests for a second time, the test-retest reliability of iTUG was also evaluated. Among the subcomponents of iTUG, gait, turning, and turn-to-sit were the most reliable and sit-to-stand was the least reliable.


IEEE Transactions on Biomedical Engineering | 2007

Quantification of Tremor and Bradykinesia in Parkinson's Disease Using a Novel Ambulatory Monitoring System

A. Salarian; H. Russmann; Christian Wider; Pierre Burkhard; François Vingerhoets; Kamiar Aminian

An ambulatory system for quantification of tremor and bradykinesia in patients with Parkinsons disease (PD) is presented. To record movements of the upper extremities, a sensing units which included miniature gyroscopes, has been fixed to each of the forearms. An algorithm to detect and quantify tremor and another algorithm to quantify bradykinesia have been proposed and validated. Two clinical studies have been performed. In the first study, 10 PD patients and 10 control subjects participated in a 45-min protocol of 17 typical daily activities. The algorithm for tremor detection showed an overall sensitivity of 99.5% and a specificity of 94.2% in comparison to a video reference. The estimated tremor amplitude showed a high correlation to the Unified Parkinsons Disease Rating Scale (UPDRS) tremor subscore (e.g., r=0.87, p<0.001 for the roll axis). There was a high and significant correlation between the estimated bradykinesia related parameters estimated for the whole period of measurement and respective UPDRS subscore (e.g., r=-0.83, p<0.001 for the roll axis). In the second study, movements of upper extremities of 11 PD patients were recorded for periods of 3-5 hr. The patients were moving freely during the measurements. The effects of selection of window size used to calculate tremor and bradykinesia related parameters on the correlation between UPDRS and these parameters were studied. By selecting a window similar to the period of the first study, similar correlations were obtained. Moreover, one of the bradykinesia related parameters showed significant correlation (r=-0.74, p<0.01) to UPDRS with window sizes as short as 5 min. Our study provides evidence that objective, accurate and simultaneous assessment of tremor and bradykinesia can be achieved in free moving PD patients during their daily activities


Journal of Neurology, Neurosurgery, and Psychiatry | 2010

The instrumented timed up and go test: potential outcome measure for disease modifying therapies in Parkinson's disease

Cris Zampieri; A. Salarian; Patricia Carlson-Kuhta; Kamiar Aminian; John G. Nutt; Fay B. Horak

The Timed Up and Go (TUG) test has been used to assess balance and mobility in Parkinsons Disease (PD). However, it is not known if this test is sensitive to subtle abnormalities present in early stages of the disease, when balance and gait problems are not clinically evident but may be detected with instrumented analysis of movement. We hypothesise that postural transitions and arm swing during gait will be the most sensitive characteristics of the TUG for early PD. In the present study, we instrumented the TUG test (iTUG) using portable inertial sensors, and extended the walking distance from 3 m (traditional TUG) to 7 m. Twelve subjects with early-to-moderate, untreated PD and 12 healthy individuals participated. Our findings show that although the stopwatch measure of TUG duration did not detect any abnormalities in early-to-mid-stage PD, the peak arm swing velocity on the more affected side, average turning velocity, cadence and peak trunk rotation velocity were significantly slower. These iTUG parameters were also correlated with the Unified Parkinsons Disease Rating Motor Scale. Thus, the iTUG test is sensitive to untreated PD and could potentially detect progression of PD and response to symptomatic and disease-modifying treatments.


Journal of Neuroengineering and Rehabilitation | 2012

ISway: a sensitive, valid and reliable measure of postural control

M. Mancini; A. Salarian; Patricia Carlson-Kuhta; Cris Zampieri; Laurie A. King; Lorenzo Chiari; Fay B. Horak

BackgroundClinicians need a practical, objective test of postural control that is sensitive to mild neurological disease, shows experimental and clinical validity, and has good test-retest reliability. We developed an instrumented test of postural sway (ISway) using a body-worn accelerometer to offer an objective and practical measure of postural control.MethodsWe conducted two separate studies with two groups of subjects. Study I: sensitivity and experimental concurrent validity. Thirteen subjects with early, untreated Parkinson’s disease (PD) and 12 age-matched control subjects (CTR) were tested in the laboratory, to compare sway from force-plate COP and inertial sensors. Study II: test-retest reliability and clinical concurrent validity. A different set of 17 early-to-moderate, treated PD (tested ON medication), and 17 age-matched CTR subjects were tested in the clinic to compare clinical balance tests with sway from inertial sensors. For reliability, the sensor was removed, subjects rested for 30 min, and the protocol was repeated. Thirteen sway measures (7 time-domain, 5 frequency-domain measures, and JERK) were computed from the 2D time series acceleration (ACC) data to determine the best metrics for a clinical balance test.ResultsBoth center of pressure (COP) and ACC measures differentiated sway between CTR and untreated PD. JERK and time-domain measures showed the best test-retest reliability (JERK ICC was 0.86 in PD and 0.87 in CTR; time-domain measures ICC ranged from 0.55 to 0.84 in PD and from 0.60 to 0.89 in CTR). JERK, all but one time-domain measure, and one frequency measure were significantly correlated with the clinical postural stability score (r ranged from 0.50 to 0.63, 0.01 < p < 0.05).ConclusionsBased on these results, we recommend a subset of the most sensitive, reliable, and valid ISway measures to characterize posture control in PD: 1) JERK, 2) RMS amplitude and mean velocity from the time-domain measures, and 3) centroidal frequency as the best frequency measure, as valid and reliable measures of balance control from ISway.


IEEE Transactions on Biomedical Engineering | 2007

Ambulatory Monitoring of Physical Activities in Patients With Parkinson's Disease

A. Salarian; H. Russmann; François Vingerhoets; Pierre Burkhard; Kamiar Aminian

A new ambulatory method of monitoring physical activities in Parkinsons disease (PD) patients is proposed based on a portable data-logger with three body-fixed inertial sensors. A group of ten PD patients treated with subthalamic nucleus deep brain stimulation (STN-DBS) and ten normal control subjects followed a protocol of typical daily activities and the whole period of the measurement was recorded by video. Walking periods were recognized using two sensors on shanks and lying periods were detected using a sensor on trunk. By calculating kinematics features of the trunk movements during the transitions between sitting and standing postures and using a statistical classifier, sit-to-stand (SiSt) and stand-to-sit (StSi) transitions were detected and separated from other body movements. Finally, a fuzzy classifier used this information to detect periods of sitting and standing. The proposed method showed a high sensitivity and specificity for the detection of basic body postures allocations: sitting, standing, lying, and walking periods, both in PD patients and healthy subjects. We found significant differences in parameters related to SiSt and StSi transitions between PD patients and controls and also between PD patients with and without STN-DBS turned on. We concluded that our method provides a simple, accurate, and effective means to objectively quantify physical activities in both normal and PD patients and may prove useful to assess the level of motor functions in the latter.


Gait & Posture | 2012

Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed.

Rebecca Spain; R.J. St. George; A. Salarian; Martina Mancini; J.M. Wagner; Fay B. Horak; Dennis Bourdette

While balance and gait limitations are hallmarks of multiple sclerosis (MS), standard stopwatch-timed measures practical for use in the clinic are insensitive in minimally affected patients. This prevents early detection and intervention for mobility problems. The study sought to determine if body-worn sensors could detect differences in balance and gait between people with MS with normal walking speeds and healthy controls. Thirty-one MS and twenty-eight age- and sex-matched control subjects were tested using body-worn sensors both during quiet stance and gait (Timed Up and Go test, TUG). Results were compared to stopwatch-timed measures. Stopwatch durations of the TUG and Timed 25 Foot Walk tests were not significantly different between groups. However, during quiet stance with eyes closed, people with MS had significantly greater sway acceleration amplitude than controls (p=0.02). During gait, people with MS had greater trunk angular range of motion in roll (medio-lateral flexion, p=0.017) and yaw (axial rotation, p=0.026) planes. Turning duration through 180° was also longer in MS (p=0.031). Thus, body-worn motion sensors detected mobility differences between MS and healthy controls when traditional timed tests could not. This portable technology provides objective and quantitative mobility data previously not obtainable in the clinic, and may prove a useful outcome measure for early mobility changes in MS.


Parkinson's Disease | 2012

Comparing the Mini-BESTest with the Berg Balance Scale to Evaluate Balance Disorders in Parkinson's Disease

Laurie A. King; Kelsey C. Priest; A. Salarian; Don Pierce; Fay B. Horak

Objective. The purpose of this study was to explore the usefulness of the Mini-BESTest compared to the Berg Balance Scale in evaluating balance in people with PD of varying severity. We evaluated (1) the distribution of patients scores to look for ceiling effects, (2) concurrent validity with severity of disease, and (3) the sensitivity/specificity of separating people with or without postural response deficits. Subjects. Ninety-seven people with PD were tested for balance deficits using the Berg, Mini-BESTest, Unified Parkinsons Disease Rating Scale (UPDRS) III and the Hoehn & Yahr (H&Y) disease severity classification. Setting. Clinical research facility at Oregon Health & Science University. Results. The Mini-BESTest is highly correlated with the Berg (r = 0.79, P < 0.001), but avoids the ceiling compression effect of the Berg for mild PD (skewness −2.30 Berg, −0.93 Mini-BESTest). Consequently, the Mini-BESTest is more effective than the Berg for predicting UPDRS Motor score (P < 0.001 Mini-BESTest versus P = 0.86 Berg), and for discriminating between those with and without postural response deficits as measured by the H&Y (ROC differential P = 0.06). Conclusion. The Mini-BESTest is a promising tool for discerning balance deficits in patients with PD, most importantly those with more subtle deficits.


Parkinsonism & Related Disorders | 2011

Assessing mobility at home in people with early Parkinson’s disease using an instrumented Timed Up and Go test

Cris Zampieri; A. Salarian; Patricia Carlson-Kuhta; John G. Nutt; Fay B. Horak

Gait and mobility problems are prominent features of Parkinsons Disease (PD), and are difficult to observe clinically in early stages of PD. We previously reported that gait changes were measurable in early to mid-stage PD subjects, when we used inertial sensors during an instrumented Timed Up and Go test (iTUG). With the advent of wearable inertial sensors, home assessment of mobility has become possible. We tested six people with early PD and eight control subjects using the iTUG in the home and laboratory. Our objectives were to 1) investigate the feasibility of testing subjects at home, and 2) compare performance at home versus laboratory. We found that home iTUG testing is feasible and the patients with PD were more affected than the healthy control subjects when tested at home.


Journal of Bioengineering and Biomedical Science | 2013

Mobility Lab to Assess Balance and Gait with Synchronized Body-worn Sensors.

Martina Mancini; Laurie A. King; A. Salarian; Lars Holmstrom; James McNames; Fay B. Horak

This paper is a commentary to introduce how rehabilitation professionals can use a new, body-worn sensor system to obtain objective measures of balance and gait. Current assessments of balance and gait in clinical rehabilitation are largely limited to subjective scales, simple stop-watch measures, or complex, expensive machines not practical or largely available. Although accelerometers and gyroscopes have been shown to accurately quantify many aspects of gait and balance kinematics, only recently a comprehensive, portable system has become available for clinicians. By measuring body motion during tests that clinicians are already performing, such as the Timed Up and Go test (TUG) and the Clinical Test of Sensory Integration for Balance (CITSIB), the additional time for assessment is minimal. By providing instant analysis of balance and gait and comparing a patients performance to age-matched control values, therapists receive an objective, sensitive screening profile of balance and gait strategies. This motion screening profile can be used to identify mild abnormalities not obvious with traditional clinical testing, measure small changes due to rehabilitation, and design customized rehabilitation programs for each individuals specific balance and gait deficits.

Collaboration


Dive into the A. Salarian's collaboration.

Top Co-Authors

Avatar

Kamiar Aminian

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

H. Russmann

University Hospital of Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Y. Blanc

University of Geneva

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge