Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Adaias O. Matos is active.

Publication


Featured researches published by Adaias O. Matos.


Biointerphases | 2016

Production of a biofunctional titanium surface using plasma electrolytic oxidation and glow-discharge plasma for biomedical applications

Thamara Beline; Isabella da Silva Vieira Marques; Adaias O. Matos; Erika S. Ogawa; Antônio Pedro Ricomini-Filho; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Cortino Sukotjo; Mathew T. Mathew; Richard Landers; Rafael Leonardo Xediek Consani; Marcelo Ferraz Mesquita; Valentim Adelino Ricardo Barão

In this study, the authors tested the hypotheses that plasma electrolytic oxidation (PEO) and glow-discharge plasma (GDP) would improve the electrochemical, physical, chemical, and mechanical properties of commercially pure titanium (cpTi), and that blood protein adsorption on plasma-treated surfaces would increase. Machined and sandblasted surfaces were used as controls. Standard electrochemical tests were conducted in artificial saliva (pHs of 3.0, 6.5, and 9.0) and simulated body fluid. Surfaces were characterized by scanning electron microscopy, energy-dispersive spectroscopy, x-ray photoelectron spectroscopy, atomic force microscopy, x-ray diffraction, profilometry, Vickers microhardness, and surface energy. For biological assay, the adsorption of blood serum proteins (i.e., albumin, fibrinogen, and fibronectin) was tested. Higher values of polarization resistance and lower values of capacitance were noted for the PEO and GDP groups (p < 0.05). Acidic artificial saliva reduced the corrosion resistance of cpTi (p < 0.05). PEO and GDP treatments improved the surface properties by enrichment of the surface chemistry with bioactive elements and increased surface energy. PEO produced a porous oxide layer (5-μm thickness), while GDP created a very thin oxide layer (0.76-μm thickness). For the PEO group, the authors noted rutile and anatase crystalline structures that may be responsible for the corrosion barrier improvement and increased microhardness values. Plasma treatments were able to enhance the surface properties and electrochemical stability of titanium, while increasing protein adsorption levels.


Materials Science and Engineering: C | 2016

Surface-treated commercially pure titanium for biomedical applications: Electrochemical, structural, mechanical and chemical characterizations.

Erika S. Ogawa; Adaias O. Matos; Thamara Beline; Isabella da Silva Vieira Marques; Cortino Sukotjo; Mathew T. Mathew; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

Modified surfaces have improved the biological performance and biomechanical fixation of dental implants compared to machined (polished) surfaces. However, there is a lack of knowledge about the surface properties of titanium (Ti) as a function of different surface treatment. This study investigated the role of surface treatments on the electrochemical, structural, mechanical and chemical properties of commercial pure titanium (cp-Ti) under different electrolytes. Cp-Ti discs were divided into 6 groups (n = 5): machined (M—control); etched with HCl + H2O2 (Cl), H2SO4 + H2O2 (S); sandblasted with Al2O3 (Sb), Al2O3 followed by HCl + H2O2 (SbCl), and Al2O3 followed by H2SO4 + H2O2 (SbS). Electrochemical tests were conducted in artificial saliva (pHs 3; 6.5 and 9) and simulated body fluid (SBF—pH 7.4). All surfaces were characterized before and after corrosion tests using atomic force microscopy, scanning electron microscopy, energy dispersive microscopy, X-ray diffraction, surface roughness, Vickers microhardness and surface free energy. The results indicated that Cl group exhibited the highest polarization resistance (Rp) and the lowest capacitance (Q) and corrosion current density (Icorr) values. Reduced corrosion stability was noted for the sandblasted groups. Acidic artificial saliva decreased the Rp values of cp-Ti surfaces and produced the highest Icorr values. Also, the surface treatment and corrosion process influenced the surface roughness, Vickers microhardness and surface free energy. Based on these results, it can be concluded that acid-etching treatment improved the electrochemical stability of cp-Ti and all treated surfaces behaved negatively in acidic artificial saliva.


international conference on robotics and automation | 1996

On the design and implementation of a control architecture for a mobile robotic system

João Borges de Sousa; Fernando Lobo Pereira; E.P. da Silva; Alfredo Martins; Adaias O. Matos; J. Almeida; Nuno Cruz; R. Tunes; Sílvia Cunha

In this article, we describe the analysis, design and implementation of a control architecture for a mobile platform to autonomously carry out transportation, surveillance and inspection tasks in semi-structured industrial environments. Based on a hierarchical structure composed by the organization, coordination and functional levels organized linguistically and structured according to the principle of increasing precision with decreasing intelligence, this control architecture permits the real-time parallel execution of tasks.


Colloids and Surfaces B: Biointerfaces | 2017

Three-species biofilm model onto plasma-treated titanium implant surface

Adaias O. Matos; Antônio Pedro Ricomini-Filho; Thamara Beline; Erika S. Ogawa; Bárbara E. Costa-Oliveira; Amanda Bandeira de Almeida; Francisco Humberto Nociti Júnior; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Cortino Sukotjo; Mathew T. Mathew; Valentim Adelino Ricardo Barão

In this study, titanium (Ti) was modified with biofunctional and novel surface by micro-arc oxidation (MAO) and glow discharge plasma (GDP) and we tested the development of a three-species periodontopatogenic biofilm onto the treated commercially-pure titanium (cpTi) surfaces. Machined and sandblasted surfaces were used as control group. Several techniques for surface characterizations and monoculture on bone tissue cells were performed. A multispecies biofilm composed of Streptococcus sanguinis, Actinomyces naeslundii and Fusobacterium nucleatum was developed onto cpTi discs for 16.5h (early biofilm) and 64.5h (mature biofilm). The number of viable microorganisms and the composition of the extracellular matrix (proteins and carbohydrates) were determined. The biofilm organization was analyzed by scanning electron microscopy (SEM) and Confocal laser scanning microscopy (CLSM). In addition, MC3T3-E1 cells were cultured on the Ti surfaces and cell proliferation (MTT) and morphology (SEM) were assessed. MAO treatment produced oxide films rich in calcium and phosphorus with a volcano appearance while GDP treatment produced silicon-based smooth thin-film. Plasma treatments were able to increase the wettability of cpTi (p<0.05). An increase of surface roughness (p<0.05) and formation of anatase and rutile structures was noted after MAO treatment. GDP had the greatest surface free energy (p<0.05) while maintaining the surface roughness compared to the machined control (p>0.05). Plasma treatment did not affect the viable microorganisms counts, but the counts of F. nucleatum was lower for MAO treatment at early biofilm phase. Biofilm extracellular matrix was similar among the groups, excepted for GDP that presented the lowest protein content. Moreover, cell proliferation was not significantly affected by the experimental, except for MAO at 6days that resulted in an increased cell proliferative. Together, these findings indicate that plasma treatments are a viable and promising technology to treat bone-integrated dental implants as the new surfaces displayed improved mechanical and biological properties with no increase in biofilm proliferation.


Materials Science and Engineering: C | 2016

Effect of nonthermal plasma treatment on surface chemistry of commercially-pure titanium and shear bond strength to autopolymerizing acrylic resin

Aljomar José Vechiato-Filho; Isabella da Silva Vieira Marques; Daniela Micheline dos Santos; Adaias O. Matos; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Valentim Adelino Ricardo Barão

The effect of nonthermal plasma on the surface characteristics of commercially pure titanium (cp-Ti), and on the shear bond strength between an autopolymerizing acrylic resin and cp-Ti was investigated. A total of 96 discs of cp-Ti were distributed into four groups (n=24): Po (no surface treatment), SB (sandblasting), Po+NTP and SB+NTP (methane plasma). Surface characterization was performed through surface energy, surface roughness, scanning microscopy, energy dispersive spectroscopy, and X-ray diffraction tests. Shear bond strength test was conducted immediately and after thermocycling. Surface treatment affected the surface energy and roughness of cp-Ti discs (P<.001). SEM-EDS showed the presence of the carbide thin film. XRD spectra revealed no crystalline phase changes. The SB+NTP group showed the highest bond strength values (6.76±0.70 MPa). Thermocycling reduced the bond strength of the acrylic resin/cp-Ti interface (P<.05), except for Po group. NTP is an effective treatment option for improving the shear bond strength between both materials.


Journal of Prosthetic Dentistry | 2018

Electrochemical behavior of titanium exposed to a biofilm supplemented with different sucrose concentrations

João Gabriel Silva Souza; Thamara Beline; Adaias O. Matos; Bárbara Emanoele Costa Oliveira; Antônio Pedro Ricomini-Filho; Valentim Adelino Ricardo Barão

Statement of problem. Biofilms can reduce the corrosion resistance of titanium because of the bacterial metabolism of fermentable carbohydrates, including sucrose. However, studies evaluating whether biofilms exposed to higher sucrose concentrations can affect the electrochemical behavior of titanium are lacking. Purpose. The purpose of this in vitro study was to test the electrochemical behavior of titanium previously exposed to biofilm supplemented with different sucrose concentrations. Material and methods. Streptococcus mutans UA159 biofilms were formed on commercially pure titanium (cpTi) surfaces and supplemented constantly with different sucrose concentrations (0%, 1%, 10%, and 40%) for 7 days (experimental groups) (n=12 per group). CpTi disks without biofilm were used as a control (n=12). The standard electrochemical tests open‐circuit potential, electrochemical impedance spectroscopy, and potentiodynamic curve were performed. Data were submitted to ANOVA and the Tukey honestly significant difference (HSD) tests (&agr;=.05). Results. The biofilm exposed to sucrose had an increased biofilm dry weight (P<.05). The polysaccharide amount and the pH drop were higher in the groups exposed to sucrose (P<.05). No difference was noted between the control and experimental groups for the electrochemical properties of cpTi (P>.05). Conclusions. Biofilms exposed to greater carbohydrate concentration did not alter the corrosive behavior of titanium.


Materials Science and Engineering: C | 2017

Surface analysis and shear bond strength of zirconia on resin cements after non-thermal plasma treatment and/or primer application for metallic alloys

Aljomar José Vechiato-Filho; Adaias O. Matos; Richard Landers; Marcelo Coelho Goiato; Elidiane Cipriano Rangel; Grace M. De Souza; Valentim Adelino Ricardo Barão; Daniela Micheline dos Santos

There is no established protocol for bonding zirconia (Y-TZP) with resin cements. Non-thermal plasma (NTP) may be an alternative for the clinical problems related to adhesion. The purpose of the present study was to characterize the surface of Y-TZP exposed to methane (CH4) NTP or coated with a layer of primer for metal alloys and the association between the two methods and to evaluate the effect of NTP treatment on bond strength between Y-TZP and two resin cements. A total of 235 Y-TZP discs (8×2mm) were distributed into five groups: Co (no surface treatment), Pr (primer), NTP (methane plasma), Pr+NTP and NTP+Pr. The effect of the treatment type on the surface free energy, morphology, topography and chemical composition of the Y-TZP discs was investigated. The discs were cemented to composite resin substrates using Panavia F2.0 or RelyX U200. Shear bond strength (n=10) analyses were performed (1mm/min) before and after thermocycling (5-55°C, 2000cycles) on the bonded specimens. The data were analyzed with one and three-way ANOVAs and Bonferroni tests (α=0.05). NTP reduced the surface energy and roughness of the Y-TZP discs. SEM-EDS and XPS analyses showed the presence of the organic thin film, which significantly improved the bond strength results when Rely X U200 was used, whereas the primer treatment was more effective with Panavia F2.0. Thermocycling significantly reduced the bond strength results of the NTP and Pr+NTP groups cemented with Rely X U200 and the Pr and NTP+Pr groups cemented with Panavia F2.0. Nonthermal plasma improves the bond strength between Rely X U200 and Y-TZP and also seems to have water-resistant behavior, whereas Panavia F2.0 showed better results when associated with primer.


Materials Science and Engineering: C | 2016

Surface Treatment Influences Electrochemical Stability Of Cpti Exposed To Mouthwashes

Thamara Beline; Camila S. Garcia; Erika S. Ogawa; Isabella da Silva Vieira Marques; Adaias O. Matos; Cortino Sukotjo; Mathew T. Mathew; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

The role of surface treatment on the electrochemical behavior of commercially pure titanium (cpTi) exposed to mouthwashes was tested. Seventy-five disks were divided into 15 groups according to surface treatment (machined, sand blasted with Al2O3, and acid etched) and electrolyte solution (artificial saliva — control, 0.12% chlorhexidine digluconate, 0.05% cetylpyridinium chloride, 0.2% sodium fluoride, and 1.5% hydrogen peroxide) (n = 5). Open-circuit-potential and electrochemical impedance spectroscopy were conducted at baseline and after 7 and 14 days of immersion in each solution. Potentiodynamic test and total weight loss of disks were performed after 14 days of immersion. Scanning electron microscopy, energy dispersive spectroscopy, white light interferometry and profilometry were conducted for surface characterization before and after the electrochemical tests. Sandblasting promoted the lowest polarization resistance (Rp) (P b .0001) and the highest capacitance (CPE) (P b .006), corrosion current density (Icorr) and corrosion rate (P b .0001). In contrast, acid etching increased Rp and reduced CPE, independent to the mouthwash; while hydrogen peroxide reduced Rp (P b .008) and increased Icorr and corrosion rate (P b .0001). The highest CPE values were found for hydrogen peroxide and 0.2% sodium fluoride. Immersion for longer period improved the electrochemical stability of cpTi (P b .05). In conclusion, acid etching enhanced the electrochemical stability of cpTi. Hydrogen peroxide and sodium fluoride reduced the resistance to corrosion of cpTi, independent to the surface treatment. Chlorhexidine gluconate and cetylpyridinium chloride did not alter the corrosive behavior of cpTi.


Journal of Prosthodontics | 2018

Effect of Disinfection on the Bond Strength between Denture Teeth and Microwave-Cured Acrylic Resin Denture Base.

Adaias O. Matos; Josiane O. Costa; Thamara Beline; Erika S. Ogawa; Wirley Gonçalves Assunção; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

PURPOSE Denture tooth debonding is a common complication for denture wearers; however, the effect of complete denture disinfection on bonding between denture teeth and acrylic resin remains unclear. The aim of this study was to evaluate the effect of disinfection methods on the bond strength between denture teeth and microwave-cured acrylic resin denture base. MATERIALS AND METHODS Three commercial brands of denture teeth (Trilux, Biolux, Vipi Dent Plus) and one microwave-cured acrylic resin denture base were tested. Each brand of denture teeth was divided into seven groups (n = 6; estimated by partial Eta squared). The specimenss of groups H and Cl were immersed in 1% sodium hypochlorite and 4% chlorhexidine digluconate for 7 days, respectively. In group Br, the specimens were subjected to toothbrush simulation under 200 g of force for 20,000 cycles. In groups Br-H and Br-Cl, the specimens were brushed and further disinfected with 1% sodium hypochlorite and 4% chlorhexidine digluconate, respectively. In control groups 1 (Co1) and 2 (Co2), the specimens were stored in distilled water for 50 ± 2 hours and 7 days, respectively. Shear bond strength testing was performed at the resin/tooth interface in a universal testing machine at a 1 mm/min crosshead speed. The failure pattern was quantified and classified into adhesive, cohesive, or mixed. Data were analyzed using two-way ANOVA and Tukey HSD test (α = 0.05). RESULTS Disinfection with 1% sodium hypochlorite (p = 0.031), brushing (p < 0.0001), and association of brushing with either 1% sodium hypochlorite (p < 0.0001) or 4% chlorhexidine digluconate (p = 0.01) reduced the bond strength between denture teeth and microwave-cured acrylic resin denture base. All commercial brands of denture teeth presented a similar bond strength (p > 0.05). The failure pattern was predominantly adhesive independent of the disinfection method and denture tooth brand. CONCLUSIONS Disinfection with sodium hypochlorite, brushing, and the association of mechanical and chemical methods reduced the bond strength between denture tooth and microwave-cured acrylic resin denture base.


Ceramics | 2018

Bacterial Adhesion on Lithium Disilicate Ceramic Surface Exposed to Different Hydrofluoric Solutions

Daniela Micheline dos Santos; Emily Vivianne Freitas da Silva; Adaias O. Matos; Beatriz Cristiane Zuin Monteiro; Rodrigo Antonio de Medeiros; Sandro Basso Bitencourt; Valentim Adelino Ricardo Barão; Elidiane Cipriano Rangel; Marcelo Coelho Goiato

Collaboration


Dive into the Adaias O. Matos's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Thamara Beline

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar

Erika S. Ogawa

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar

Cortino Sukotjo

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Mathew T. Mathew

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rafael X. Consani

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge