Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Thamara Beline is active.

Publication


Featured researches published by Thamara Beline.


Biointerphases | 2016

Production of a biofunctional titanium surface using plasma electrolytic oxidation and glow-discharge plasma for biomedical applications

Thamara Beline; Isabella da Silva Vieira Marques; Adaias O. Matos; Erika S. Ogawa; Antônio Pedro Ricomini-Filho; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Cortino Sukotjo; Mathew T. Mathew; Richard Landers; Rafael Leonardo Xediek Consani; Marcelo Ferraz Mesquita; Valentim Adelino Ricardo Barão

In this study, the authors tested the hypotheses that plasma electrolytic oxidation (PEO) and glow-discharge plasma (GDP) would improve the electrochemical, physical, chemical, and mechanical properties of commercially pure titanium (cpTi), and that blood protein adsorption on plasma-treated surfaces would increase. Machined and sandblasted surfaces were used as controls. Standard electrochemical tests were conducted in artificial saliva (pHs of 3.0, 6.5, and 9.0) and simulated body fluid. Surfaces were characterized by scanning electron microscopy, energy-dispersive spectroscopy, x-ray photoelectron spectroscopy, atomic force microscopy, x-ray diffraction, profilometry, Vickers microhardness, and surface energy. For biological assay, the adsorption of blood serum proteins (i.e., albumin, fibrinogen, and fibronectin) was tested. Higher values of polarization resistance and lower values of capacitance were noted for the PEO and GDP groups (p < 0.05). Acidic artificial saliva reduced the corrosion resistance of cpTi (p < 0.05). PEO and GDP treatments improved the surface properties by enrichment of the surface chemistry with bioactive elements and increased surface energy. PEO produced a porous oxide layer (5-μm thickness), while GDP created a very thin oxide layer (0.76-μm thickness). For the PEO group, the authors noted rutile and anatase crystalline structures that may be responsible for the corrosion barrier improvement and increased microhardness values. Plasma treatments were able to enhance the surface properties and electrochemical stability of titanium, while increasing protein adsorption levels.


Dental Materials | 2017

Development of binary and ternary titanium alloys for dental implants

Jairo M. Cordeiro; Thamara Beline; Ana Lúcia Roselino Ribeiro; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Richard Landers; Leonardo Perez Faverani; Luis Geraldo Vaz; Laiza Maria Grassi Fais; Fábio Bossoi Vicente; Carlos Roberto Grandini; Mathew T. Mathew; Cortino Sukotjo; Valentim Adelino Ricardo Barão

OBJECTIVE The aim of this study was to develop binary and ternary titanium (Ti) alloys containing zirconium (Zr) and niobium (Nb) and to characterize them in terms of microstructural, mechanical, chemical, electrochemical, and biological properties. METHODS The experimental alloys - (in wt%) Ti-5Zr, Ti-10Zr, Ti-35Nb-5Zr, and Ti-35Nb-10Zr - were fabricated from pure metals. Commercially pure titanium (cpTi) and Ti-6Al-4V were used as controls. Microstructural analysis was performed by means of X-ray diffraction and scanning electron microscopy. Vickers microhardness, elastic modulus, dispersive energy spectroscopy, X-ray excited photoelectron spectroscopy, atomic force microscopy, surface roughness, and surface free energy were evaluated. The electrochemical behavior analysis was conducted in a body fluid solution (pH 7.4). The albumin adsorption was measured by the bicinchoninic acid method. Data were evaluated through one-way ANOVA and the Tukey test (α=0.05). RESULTS The alloying elements proved to modify the alloy microstructure and to enhance the mechanical properties, improving the hardness and decreasing the elastic modulus of the binary and ternary alloys, respectively. Ti-Zr alloys displayed greater electrochemical stability relative to that of controls, presenting higher polarization resistance and lower capacitance. The experimental alloys were not detrimental to albumin adsorption. SIGNIFICANCE The experimental alloys are suitable options for dental implant manufacturing, particularly the binary system, which showed a better combination of mechanical and electrochemical properties without the presence of toxic elements.


Materials Science and Engineering: C | 2016

Surface-treated commercially pure titanium for biomedical applications: Electrochemical, structural, mechanical and chemical characterizations.

Erika S. Ogawa; Adaias O. Matos; Thamara Beline; Isabella da Silva Vieira Marques; Cortino Sukotjo; Mathew T. Mathew; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

Modified surfaces have improved the biological performance and biomechanical fixation of dental implants compared to machined (polished) surfaces. However, there is a lack of knowledge about the surface properties of titanium (Ti) as a function of different surface treatment. This study investigated the role of surface treatments on the electrochemical, structural, mechanical and chemical properties of commercial pure titanium (cp-Ti) under different electrolytes. Cp-Ti discs were divided into 6 groups (n = 5): machined (M—control); etched with HCl + H2O2 (Cl), H2SO4 + H2O2 (S); sandblasted with Al2O3 (Sb), Al2O3 followed by HCl + H2O2 (SbCl), and Al2O3 followed by H2SO4 + H2O2 (SbS). Electrochemical tests were conducted in artificial saliva (pHs 3; 6.5 and 9) and simulated body fluid (SBF—pH 7.4). All surfaces were characterized before and after corrosion tests using atomic force microscopy, scanning electron microscopy, energy dispersive microscopy, X-ray diffraction, surface roughness, Vickers microhardness and surface free energy. The results indicated that Cl group exhibited the highest polarization resistance (Rp) and the lowest capacitance (Q) and corrosion current density (Icorr) values. Reduced corrosion stability was noted for the sandblasted groups. Acidic artificial saliva decreased the Rp values of cp-Ti surfaces and produced the highest Icorr values. Also, the surface treatment and corrosion process influenced the surface roughness, Vickers microhardness and surface free energy. Based on these results, it can be concluded that acid-etching treatment improved the electrochemical stability of cp-Ti and all treated surfaces behaved negatively in acidic artificial saliva.


Colloids and Surfaces B: Biointerfaces | 2017

Three-species biofilm model onto plasma-treated titanium implant surface

Adaias O. Matos; Antônio Pedro Ricomini-Filho; Thamara Beline; Erika S. Ogawa; Bárbara E. Costa-Oliveira; Amanda Bandeira de Almeida; Francisco Humberto Nociti Júnior; Elidiane Cipriano Rangel; Nilson Cristino da Cruz; Cortino Sukotjo; Mathew T. Mathew; Valentim Adelino Ricardo Barão

In this study, titanium (Ti) was modified with biofunctional and novel surface by micro-arc oxidation (MAO) and glow discharge plasma (GDP) and we tested the development of a three-species periodontopatogenic biofilm onto the treated commercially-pure titanium (cpTi) surfaces. Machined and sandblasted surfaces were used as control group. Several techniques for surface characterizations and monoculture on bone tissue cells were performed. A multispecies biofilm composed of Streptococcus sanguinis, Actinomyces naeslundii and Fusobacterium nucleatum was developed onto cpTi discs for 16.5h (early biofilm) and 64.5h (mature biofilm). The number of viable microorganisms and the composition of the extracellular matrix (proteins and carbohydrates) were determined. The biofilm organization was analyzed by scanning electron microscopy (SEM) and Confocal laser scanning microscopy (CLSM). In addition, MC3T3-E1 cells were cultured on the Ti surfaces and cell proliferation (MTT) and morphology (SEM) were assessed. MAO treatment produced oxide films rich in calcium and phosphorus with a volcano appearance while GDP treatment produced silicon-based smooth thin-film. Plasma treatments were able to increase the wettability of cpTi (p<0.05). An increase of surface roughness (p<0.05) and formation of anatase and rutile structures was noted after MAO treatment. GDP had the greatest surface free energy (p<0.05) while maintaining the surface roughness compared to the machined control (p>0.05). Plasma treatment did not affect the viable microorganisms counts, but the counts of F. nucleatum was lower for MAO treatment at early biofilm phase. Biofilm extracellular matrix was similar among the groups, excepted for GDP that presented the lowest protein content. Moreover, cell proliferation was not significantly affected by the experimental, except for MAO at 6days that resulted in an increased cell proliferative. Together, these findings indicate that plasma treatments are a viable and promising technology to treat bone-integrated dental implants as the new surfaces displayed improved mechanical and biological properties with no increase in biofilm proliferation.


Ciencia & Saude Coletiva | 2016

Prevalence of suggestive images of carotid artery calcifications on panoramic radiographs and its relationship with predisposing factors

Ana Caroline Ramos de Brito; Helena Aguiar Ribeiro Nascimento; Rafaela Argento; Thamara Beline; Gláucia Maria Bovi Ambrosano; Deborah Queiroz Freitas

Panoramic radiographs (PR) can display radiopaque images suggestive of calcified atheroma in the carotid artery in asymptomatic patients. The aim of this study was to evaluate the prevalence of these images on PR and their linkage with hypertension, obesity, age, gender and smoking habits. PR of 505 patients were evaluated. They were older than 30 years old and their PR had been taken for different clinical reasons. Their body mass index was calculated; their waist circumference was also taken into consideration. Information about smoking habits and hypertension was obtained. The observers analyzed the presence of radiopaque mass in the region of the cervical vertebrae C3-C4 through the PR, confirmed by an antero-posterior (AP) radiograph. The results showed a 7.92% prevalence of suggestive images of calcifications on PR and on AP radiograph. The adjusted Odds Ratio showed association with age and smoking habits. The calcification process is almost nine times higher for the elderly when compared to the young. As far as smokers are concerned, this process is twice worse when compared to no smokers. In conclusion, 7.92% of the group studied presented suggestive images of carotid atherosclerosis on PR, which is directly associated with the age and smoking habits.


Journal of Prosthetic Dentistry | 2018

Electrochemical behavior of titanium exposed to a biofilm supplemented with different sucrose concentrations

João Gabriel Silva Souza; Thamara Beline; Adaias O. Matos; Bárbara Emanoele Costa Oliveira; Antônio Pedro Ricomini-Filho; Valentim Adelino Ricardo Barão

Statement of problem. Biofilms can reduce the corrosion resistance of titanium because of the bacterial metabolism of fermentable carbohydrates, including sucrose. However, studies evaluating whether biofilms exposed to higher sucrose concentrations can affect the electrochemical behavior of titanium are lacking. Purpose. The purpose of this in vitro study was to test the electrochemical behavior of titanium previously exposed to biofilm supplemented with different sucrose concentrations. Material and methods. Streptococcus mutans UA159 biofilms were formed on commercially pure titanium (cpTi) surfaces and supplemented constantly with different sucrose concentrations (0%, 1%, 10%, and 40%) for 7 days (experimental groups) (n=12 per group). CpTi disks without biofilm were used as a control (n=12). The standard electrochemical tests open‐circuit potential, electrochemical impedance spectroscopy, and potentiodynamic curve were performed. Data were submitted to ANOVA and the Tukey honestly significant difference (HSD) tests (&agr;=.05). Results. The biofilm exposed to sucrose had an increased biofilm dry weight (P<.05). The polysaccharide amount and the pH drop were higher in the groups exposed to sucrose (P<.05). No difference was noted between the control and experimental groups for the electrochemical properties of cpTi (P>.05). Conclusions. Biofilms exposed to greater carbohydrate concentration did not alter the corrosive behavior of titanium.


Materials Science and Engineering: C | 2016

Surface Treatment Influences Electrochemical Stability Of Cpti Exposed To Mouthwashes

Thamara Beline; Camila S. Garcia; Erika S. Ogawa; Isabella da Silva Vieira Marques; Adaias O. Matos; Cortino Sukotjo; Mathew T. Mathew; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

The role of surface treatment on the electrochemical behavior of commercially pure titanium (cpTi) exposed to mouthwashes was tested. Seventy-five disks were divided into 15 groups according to surface treatment (machined, sand blasted with Al2O3, and acid etched) and electrolyte solution (artificial saliva — control, 0.12% chlorhexidine digluconate, 0.05% cetylpyridinium chloride, 0.2% sodium fluoride, and 1.5% hydrogen peroxide) (n = 5). Open-circuit-potential and electrochemical impedance spectroscopy were conducted at baseline and after 7 and 14 days of immersion in each solution. Potentiodynamic test and total weight loss of disks were performed after 14 days of immersion. Scanning electron microscopy, energy dispersive spectroscopy, white light interferometry and profilometry were conducted for surface characterization before and after the electrochemical tests. Sandblasting promoted the lowest polarization resistance (Rp) (P b .0001) and the highest capacitance (CPE) (P b .006), corrosion current density (Icorr) and corrosion rate (P b .0001). In contrast, acid etching increased Rp and reduced CPE, independent to the mouthwash; while hydrogen peroxide reduced Rp (P b .008) and increased Icorr and corrosion rate (P b .0001). The highest CPE values were found for hydrogen peroxide and 0.2% sodium fluoride. Immersion for longer period improved the electrochemical stability of cpTi (P b .05). In conclusion, acid etching enhanced the electrochemical stability of cpTi. Hydrogen peroxide and sodium fluoride reduced the resistance to corrosion of cpTi, independent to the surface treatment. Chlorhexidine gluconate and cetylpyridinium chloride did not alter the corrosive behavior of cpTi.


Archive | 2018

Degradation of titanium-based implants

Sofia Afonso Alves; Thamara Beline; Valentim Adelino Ricardo Barão; Cortino Sukotjo; Mathew T. Mathew; L.A. Rocha; J.-P. Celis; J.C.M. Souza

Abstract During mastication, cyclic micromovements can be generated at dental implant connections leading to complex wear in the presence of the corrosive biological environment, such as acidic substances, bacteria metabolites, fluorides, and hydrogen peroxide. That can result in simultaneous degradation of dental implant materials by wear and corrosion processes, known as tribocorrosion. This chapter gathers knowledge from diverse fields contributing to a better understanding of the degradation mechanisms of titanium-based implants by wear-corrosion interactions in the oral environment.


Journal of Prosthodontics | 2018

Effect of Disinfection on the Bond Strength between Denture Teeth and Microwave-Cured Acrylic Resin Denture Base.

Adaias O. Matos; Josiane O. Costa; Thamara Beline; Erika S. Ogawa; Wirley Gonçalves Assunção; Marcelo Ferraz Mesquita; Rafael X. Consani; Valentim Adelino Ricardo Barão

PURPOSE Denture tooth debonding is a common complication for denture wearers; however, the effect of complete denture disinfection on bonding between denture teeth and acrylic resin remains unclear. The aim of this study was to evaluate the effect of disinfection methods on the bond strength between denture teeth and microwave-cured acrylic resin denture base. MATERIALS AND METHODS Three commercial brands of denture teeth (Trilux, Biolux, Vipi Dent Plus) and one microwave-cured acrylic resin denture base were tested. Each brand of denture teeth was divided into seven groups (n = 6; estimated by partial Eta squared). The specimenss of groups H and Cl were immersed in 1% sodium hypochlorite and 4% chlorhexidine digluconate for 7 days, respectively. In group Br, the specimens were subjected to toothbrush simulation under 200 g of force for 20,000 cycles. In groups Br-H and Br-Cl, the specimens were brushed and further disinfected with 1% sodium hypochlorite and 4% chlorhexidine digluconate, respectively. In control groups 1 (Co1) and 2 (Co2), the specimens were stored in distilled water for 50 ± 2 hours and 7 days, respectively. Shear bond strength testing was performed at the resin/tooth interface in a universal testing machine at a 1 mm/min crosshead speed. The failure pattern was quantified and classified into adhesive, cohesive, or mixed. Data were analyzed using two-way ANOVA and Tukey HSD test (α = 0.05). RESULTS Disinfection with 1% sodium hypochlorite (p = 0.031), brushing (p < 0.0001), and association of brushing with either 1% sodium hypochlorite (p < 0.0001) or 4% chlorhexidine digluconate (p = 0.01) reduced the bond strength between denture teeth and microwave-cured acrylic resin denture base. All commercial brands of denture teeth presented a similar bond strength (p > 0.05). The failure pattern was predominantly adhesive independent of the disinfection method and denture tooth brand. CONCLUSIONS Disinfection with sodium hypochlorite, brushing, and the association of mechanical and chemical methods reduced the bond strength between denture tooth and microwave-cured acrylic resin denture base.


Journal of Prosthetic Dentistry | 2018

Initial investigation of the corrosion stability of craniofacial implants

Thamara Beline; Aljomar José Vechiato Filho; Alvin G. Wee; Cortino Sukotjo; Daniela Micheline dos Santos; Thais Bianca Brandão; Valentim Adelino Ricardo Barão

Statement of problem. Although craniofacial implants have been used for retention of facial prostheses, failures are common. Titanium undergoes corrosion in the oral cavity, but the corrosion of craniofacial implants requires evaluation. Purpose. The purpose of this in vitro study was to investigate the corrosion stability of commercially pure titanium (CP Ti) exposed to simulated human perspiration at 2 different pH levels (5.5 and 8). Material and methods. Fifteen titanium disks were divided into 3 groups (n=5 per group). The control group was subjected to simulated body fluid (SBF) (control). Disks from the 2 experimental groups were immersed in simulated alkaline perspiration (SAKP) and simulated acidic perspiration (SACP). Electrochemical tests, including open circuit potential (3600 seconds), electrochemical impedance spectroscopy, and potentiodynamic tests were performed according to the standardized method of 3‐cell electrodes. Data were analyzed by 1‐way ANOVA and the Tukey honestly significant difference tests (&agr;=.05). Results. Simulated human perspiration reduced the corrosion stability of CP Ti (P<.05). The SBF group presented the lowest capacitance values (P<.05). SAKP and SACP groups showed increased values of capacitance and showed no statistically significant differences (P>.05) from each other. The increase in capacitance suggests that the acceleration of the ionic exchanges between the CP Ti and the electrolyte leads to a lower corrosion resistance. SAKP reduced the oxide layer resistance of CP Ti (P<.05), and an increased corrosion rate was noted in both simulated human perspiration groups. Conclusions. Craniofacial implants can corrode when in contact with simulated human perspiration, whereas alkaline perspiration shows a more deleterious effect. Perspiration induces a more corrosive effect than simulated body fluid.

Collaboration


Dive into the Thamara Beline's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Adaias O. Matos

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar

Cortino Sukotjo

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Mathew T. Mathew

University of Illinois at Chicago

View shared research outputs
Top Co-Authors

Avatar

Erika S. Ogawa

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rafael X. Consani

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge