Alan R. De Asha
University of Bradford
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Alan R. De Asha.
Clinical Biomechanics | 2013
Alan R. De Asha; Louise Johnson; Ramesh Munjal; Jai Kulkarni; John G. Buckley
BACKGROUND Disruptions to the progress of the centre-of-pressure trajectory beneath prosthetic feet have been reported previously. These disruptions reflect how body weight is transferred over the prosthetic limb and are governed by the compliance of the prosthetic foot device and its ability to simulate ankle function. This study investigated whether using an articulating hydraulic ankle attachment attenuates centre-of-pressure trajectory fluctuations under the prosthetic foot compared to a fixed attachment. METHODS Twenty active unilateral trans-tibial amputees completed walking trials at their freely-selected, comfortable walking speed using both their habitual foot with either a rigid or elastic articulating attachment and a foot with a hydraulic ankle attachment. Centre-of-pressure displacement and velocity fluctuations beneath the prosthetic foot, prosthetic shank angular velocity during stance, and walking speed were compared between foot conditions. FINDINGS Use of the hydraulic device eliminated or reduced the magnitude of posteriorly directed centre-of-pressure displacements, reduced centre-of-pressure velocity variability across single-support, increased mean forward angular velocity of the shank during early stance, and increased freely chosen comfortable walking speed (P ≤ 0.002). INTERPRETATION The attenuation of centre-of-pressure trajectory fluctuations when using the hydraulic device indicated bodyweight was transferred onto the prosthetic limb in a smoother, less faltering manner which allowed the centre of mass to translate more quickly over the foot.
Journal of Neuroengineering and Rehabilitation | 2013
Alan R. De Asha; Ramesh Munjal; Jai Kulkarni; John G. Buckley
BackgroundPassive prosthetic devices are set up to provide optimal function at customary walking speed and thus may function less effectively at other speeds. This partly explains why joint kinetic adaptations become more apparent in lower-limb amputees when walking at speeds other than customary. The present study determined whether a trans-tibial prosthesis incorporating a dynamic-response foot that was attached to the shank via an articulating hydraulic device (hy A-F) lessened speed-related adaptations in joint kinetics compared to when the foot was attached via a rigid, non-articulating attachment (rig F).MethodsEight active unilateral trans-tibial amputees completed walking trials at their customary walking speed, and at speeds they deemed to be slow-comfortable and fast-comfortable whilst using each type of foot attachment. Moments and powers at the distal end of the prosthetic shank and at the intact joints of both limbs were compared between attachment conditions.ResultsThere was no change in the amount of intact-limb ankle work across speed or attachment conditions. As speed level increased there was an increase on both limbs in the amount of hip and knee joint work done, and increases on the prosthetic side were greater when using the hy A-F. However, because all walking speed levels were higher when using the hy A-F, the intact-limb ankle and combined joints work per meter travelled were significantly lower; particularly so at the customary speed level. This was the case despite the hy A-F dissipating more energy during stance. In addition, the amount of eccentric work done per meter travelled became increased at the residual knee when using the hy A-F, with increases again greatest at customary speed.ConclusionsFindings indicate that a trans-tibial prosthesis incorporating a dynamic-response foot reduced speed-related changes in compensatory intact-limb joint kinetics when the foot was attached via an articulating hydraulic device compared to rigid attachment. As differences between attachment conditions were greatest at customary speed, findings indicate a hydraulic ankle-foot device is most effectual at the speed it is set-up for.
Prosthetics and Orthotics International | 2015
Alan R. De Asha; John G. Buckley
Background: Minimum toe clearance is a critical gait event because it coincides with peak forward velocity of the swing foot, and thus, there is an increased risk of tripping and falling. Trans-tibial amputees have increased risk of tripping compared to able-bodied individuals. Assessment of toe clearance during gait is thus clinically relevant. In able-bodied gait, minimum toe clearance increases with faster walking speeds, and it is widely reported that there is synchronicity between when peak swing-foot velocity and minimum toe clearance occur. There are no such studies involving lower-limb amputees. Objectives: To determine the effects of walking speed on minimum toe clearance and on the temporal relationship between clearance and peak swing-foot velocity in unilateral trans-tibial amputees. Study design: Cross-sectional. Methods: A total of 10 trans-tibial participants walked at slow, customary and fast speeds. Minimum toe clearance and the timings of minimum toe clearance and peak swing-foot velocity were determined and compared between intact and prosthetic sides. Results: Minimum toe clearance was reduced on the prosthetic side and, unlike on the intact side, did not increase with walking speed increase. Peak swing-foot velocity consistently occurred (~0.014 s) after point of minimum toe clearance on both limbs across all walking speeds, but there was no significant difference in the toe–ground clearance between the two events. Conclusion: The absence of speed related increases in minimum toe clearance on the prosthetic side suggests that speed related modulation of toe clearance for an intact limb typically occurs at the swing-limb ankle. The temporal consistency between peak foot velocity and minimum toe clearance on each limb suggests that swing-phase inter-segmental coordination is unaffected by trans-tibial amputation. Clinical relevance The lack of increase in minimum toe clearance on the prosthetic side at higher walking speeds may potentially increase risk of tripping. Findings indicate that determining the instant of peak swing-foot velocity will also consistently identify when/where minimum toe clearance occurs.
Journal of Neuroengineering and Rehabilitation | 2013
John G. Buckley; Alan R. De Asha; Louise Johnson; Clive B. Beggs
BackgroundIn this paper we use multivariate statistical techniques to gain insights into how adaptive gait involving obstacle crossing is regulated in lower-limb amputees compared to able-bodied controls, with the aim of identifying underlying characteristics that differ between the two groups and consequently highlighting gait deficits in the amputees.MethodsEight unilateral trans-tibial amputees and twelve able-bodied controls completed adaptive gait trials involving negotiating various height obstacles; with amputees leading with their prosthetic limb. Spatiotemporal variables that are regularly used to quantify how gait is adapted when crossing obstacles were determined and subsequently analysed using multivariate statistical techniques.Results and discussionThere were fundamental differences in the adaptive gait between the two groups. Compared to controls, amputees had a reduced approach velocity, reduced foot placement distance before and after the obstacle and reduced foot clearance over it, and reduced lead-limb knee flexion during the step following crossing. Logistic regression analysis highlighted the variables that best distinguished between the gait of the two groups and multiple regression analysis (with approach velocity as a controlling factor) helped identify what gait adaptations were driving the differences seen in these variables. Getting closer to the obstacle before crossing it appeared to be a strategy to ensure the heel of the lead-limb foot passed over the obstacle prior to the foot being lowered to the ground. Despite adopting such a heel clearance strategy, the lead-foot was positioned closer to the obstacle following crossing, which was likely a result of a desire to attain a limb/foot angle and orientation at instant of landing that minimised loads on the residuum (as evidenced by the reduced lead-limb knee flexion during the step following crossing). These changes in foot placement meant the foot was in a different part of swing at point of crossing and this explains why foot clearance was considerably reduced in amputees.ConclusionsThese results highlight that trans-tibial amputees use quite different gait adaptations to cross obstacles compared with controls (at least when leading with their prosthetic limb), indicating they are governed by different constraints; seemingly related to how they land on/load their prosthesis after crossing the obstacle.
Journal of Neuroengineering and Rehabilitation | 2014
Gabor Barton; Alan R. De Asha; Edwin Cp van Loon; Thomas Geijtenbeek; Mark A. Robinson
BackgroundA mirror placed in the mid-sagittal plane of the body has been used to reduce phantom limb pain and improve movement function in medical conditions characterised by asymmetrical movement control. The mirrored illusion of unimpaired limb movement during gait might enhance the effect, but a physical mirror is only capable of showing parallel movement of limbs in real time typically while sitting. We aimed to overcome the limitations of physical mirrors by developing and evaluating a Virtual Mirror Box which delays the mirrored image of limbs during gait to ensure temporal congruency with the impaired physical limb.MethodsAn application was developed in the CAREN system’s D-Flow software which mirrors selected limbs recorded by real-time motion capture to the contralateral side. To achieve phase shifted movement of limbs during gait, the mirrored virtual limbs are also delayed by a continuously calculated amount derived from past gait events. In order to accommodate non-normal proportions and offsets of pathological gait, the movements are morphed so that the physical and virtual contact events match on the mirrored side. Our method was tested with a trans-femoral amputee walking on a treadmill using his artificial limb. Joint angles of the elbow and knee were compared between the intact and mirrored side using cross correlation, root mean squared difference and correlation coefficients.ResultsThe time delayed adaptive virtual mirror box produced a symmetrical looking gait of the avatar coupled with a reduction of the difference between the intact and virtual knee and elbow angles (10.86° and 5.34° reduced to 4.99° and 2.54° respectively). Dynamic morphing of the delay caused a non-significant change of toe-off events when compared to delaying by 50% of the previous gait cycle, as opposed to the initial contact events which showed a practically negligible but statistically significant increase (p < 0.05).ConclusionsAdding an adaptive time delay to the Virtual Mirror Box has extended its use to treadmill gait, for the first time. Dynamic morphing resulted in a compromise between mirrored movement of the intact side and gait events of the virtual limbs matched with physical events of the impaired side. Asymmetrical but repeatable gait is expected to provide even more faithful mirroring.
Gait & Posture | 2014
Richard J Foster; Alan R. De Asha; Constantinos N. Maganaris; John G. Buckley
The present study introduces four event detection algorithms for defining touch-down and foot-off during stair descent and stair ascent using segmental kinematics. For stair descent, vertical velocity minima of the whole body center-of-mass was used to define touch-down, and foot-off was defined as the instant of trail limb peak knee flexion. For stair ascent, vertical velocity local minima of the lead-limb toe was used to define touch-down, and foot-off was defined as the local maxima in vertical displacement between the toe and pelvis. The performance of these algorithms was determined as the agreement in timings of kinematically derived events to those defined kinetically (ground reaction forces). Data were recorded while 17 young and 15 older adults completed stair descent and ascent trials over a four-step instrumented staircase. Trials were repeated for three stair riser height conditions (85 mm, 170 mm, and 255 mm). Kinematically derived touch-down and foot-off events showed good agreement (small 95% limits of agreement) with kinetically derived events for both young and older adults, across all riser heights, and for both ascent and descent. In addition, agreement metrics were better than those returned using existing kinematically derived event detection algorithms developed for overground gait. These results indicate that touch-down and foot-off during stair ascent and descent of non-instrumented staircases can be determined with acceptable precision using segmental kinematic data.
Prosthetics and Orthotics International | 2018
Gerda Strutzenberger; Nathalie Alexander; Alan R. De Asha; Hermann Schwameder; Cleveland T. Barnett
Background: An inverted pendulum model represents the mechanical function of able-bodied individuals walking accurately, with centre of mass height and forward velocity data plotting as sinusoidal curves, 180° out of phase. Objectives: This study investigated whether the inverted pendulum model represented level gait in individuals with a unilateral transfemoral amputation. Study Design: Controlled trial. Methods: Kinematic and kinetic data from 10 individuals with unilateral transfemoral amputation and 15 able-bodied participants were recorded during level walking. Results: During level walking, the inverted pendulum model described able-bodied gait well throughout the gait cycle, with median relative time shifts between centre of mass height and velocity maxima and minima between 1.2% and 1.8% of gait cycle. In the group with unilateral transfemoral amputation, the relative time shift was significantly increased during the prosthetic-limb initial double-limb support phase by 6.3%. Conclusion: The gait of individuals with unilateral transfemoral amputation shows deviation from a synchronous inverted pendulum model during prosthetic-limb stance. The reported divergence may help explain such individuals’ increased metabolic cost of gait. Temporal divergence of inverted pendulum behaviour could potentially be utilised as a tool to assess the efficacy of prosthetic device prescription. Clinical relevance The size of the relative time shifts between centre of mass height and velocity maxima and minima could potentially be used as a tool to quantify the efficacy of innovative prosthetic device design features aimed at reducing the metabolic cost of walking and improving gait efficiency in individuals with amputation.
Clinical Biomechanics | 2014
Alan R. De Asha; Ramesh Munjal; Jai Kulkarni; John G. Buckley
Journal of Rehabilitation Research and Development | 2014
Louise Johnson; Alan R. De Asha; Ramesh Munjal; Jai Kulkarni; John G. Buckley
Clinical Biomechanics | 2015
Alan R. De Asha; John G. Buckley
Collaboration
Dive into the Alan R. De Asha's collaboration.
University Hospital of South Manchester NHS Foundation Trust
View shared research outputs