Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Alessandro Olivo is active.

Publication


Featured researches published by Alessandro Olivo.


Applied Physics Letters | 2007

A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources

Alessandro Olivo; Robert D. Speller

Phase contrast imaging (PCI) solves the basic limitation of x-ray imaging, i.e., poor image contrast resulting from small absorption differences. Up to now, it has been mostly limited to synchrotron radiation facilities, due to the stringent requirements on the x-ray source and detectors, and only one technique was shown to provide PCI images with conventional sources but with limits in practical implementation. The authors propose a different approach, based on coded apertures, which provides high PCI signals with conventional sources and detectors and imposes practically no applicability limits. They expect this method to cast the basis of a widespread diffusion of PCI.


Physics in Medicine and Biology | 1998

Low-dose phase contrast x-ray medical imaging

Fulvia Arfelli; M. Assante; V. Bonvicini; A Bravin; Giovanni Cantatore; E. Castelli; L. Dalla Palma; Renata Longo; Alessandro Olivo; S. Pani; Diego Pontoni; P. Poropat; M. Prest; A. Rashevsky; Giuliana Tromba; A. Vacchi; E. Vallazza; Fabrizio Zanconati

Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.


Medical Physics | 2001

An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field

Alessandro Olivo; Fulvia Arfelli; Giovanni Cantatore; Renata Longo; R. H. Menk; S. Pani; M. Prest; P. Poropat; Luigi Rigon; Giuliana Tromba; E. Vallazza; E. Castelli

Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the medical field. On the other hand, digital radiology is undergoing a wide diffusion, and its benefits are presently very well understood. Up to now, however, the strong pixel size constraints associated with phase contrast pattern detection limited the possibility of exploiting the advantages of phase contrast in digital radiology applications. In this paper, an innovative setup capable of removing the pixel size constraints, and thus opening the way to low dose digital phase contrast imaging, is described. Furthermore, we introduce an imaging technique based on the detection of radiation scattered at small angles: the information extracted from the sample is increased at no dose expense. We believe that several radiological fields, mammography being the first important example, may benefit from the herein described innovative imaging techniques.


Proceedings of the National Academy of Sciences of the United States of America | 2012

Phase and absorption retrieval using incoherent X-ray sources

P. Munro; Konstantin Ignatyev; Robert D. Speller; Alessandro Olivo

X-ray phase contrast imaging has overcome the limitations of X-ray absorption imaging in many fields. Particular effort has been directed towards developing phase retrieval methods: These reveal quantitative information about a sample, which is a requirement for performing X-ray phase tomography, allows material identification and better distinction between tissue types, etc. Phase retrieval seems impossible with conventional X-ray sources due to their low spatial coherence. In the only previous example where conventional sources have been used, collimators were employed to produce spatially coherent secondary sources. We present a truly incoherent phase retrieval method, which removes the spatial coherence constraints and employs a conventional source without aperturing, collimation, or filtering. This is possible because our technique, based on the pixel edge illumination principle, is neither interferometric nor crystal based. Beams created by an X-ray mask to image the sample are smeared due to the incoherence of the source, yet we show that their displacements can still be measured accurately, obtaining strong phase contrast. Quantitative information is extracted from only two images rather than a sequence as required by several coherent methods. Our technique makes quantitative phase imaging and phase tomography possible in applications where exposure time and radiation dose are critical. The technique employs masks which are currently commercially available with linear dimensions in the tens of centimeters thus allowing for a large field of view. The technique works at high photon energy and thus promises to deliver much safer quantitative phase imaging and phase tomography in the future.


Medical Physics | 2014

Low-dose phase contrast tomography with conventional x-ray sources

Charlotte K. Hagen; P. Munro; Marco Endrizzi; Paul C. Diemoz; Alessandro Olivo

PURPOSE The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. METHODS Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. RESULTS The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. CONCLUSIONS The results, together with the methods dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.


Applied Physics Letters | 2014

Hard X-ray dark-field imaging with incoherent sample illumination

Marco Endrizzi; Paul C. Diemoz; Thomas P. Millard; J. Louise Jones; Robert D. Speller; Ian K. Robinson; Alessandro Olivo

We report on a non-interferometric technique enabling dark-field imaging by using incoherent illumination and two achromatic optical elements. The simultaneous retrieval of absorption and differential phase images in the hard X-ray regime is also provided. We show that three projection images are sufficient to separate three signals: absorption, differential phase, and scattering. The method is highly efficient, also in terms of the dose delivered to the sample, flexible, robust against environmental vibrations, and scalable. It can be easily implemented in laboratories and translated into commercial systems, lending itself to a wide range of applications.


Physics in Medicine and Biology | 2007

Modelling of a novel x-ray phase contrast imaging technique based on coded apertures

Alessandro Olivo; Robert D. Speller

X-ray phase contrast imaging is probably the most relevant among emerging x-ray imaging techniques, and it has the proven potential of revolutionizing the field of diagnostic radiology. Impressive images of a wide range of samples have been obtained, mostly at synchrotron radiation facilities. The necessity of relying on synchrotron radiation has prevented to a large extent a widespread diffusion of phase contrast imaging, thus precluding its transfer to clinical practice. A new technique, based on the use of coded apertures, was recently developed at UCL. This technique was demonstrated to provide intense phase contrast signals with conventional x-ray sources and detectors. Unlike other attempts at making phase contrast imaging feasible with conventional sources, the coded-aperture approach does not impose substantial limitations and/or filtering of the radiation beam, and it therefore allows, for the first time, exposures compatible with clinical practice. The technique has been thoroughly modelled, and this paper describes the technique in detail by going through the different steps of the modelling. All the main factors influencing image quality are discussed, alongside the viability of realizing a prototype suitable for clinical use. The model has been experimentally validated and a section of the paper shows the comparison between simulated and experimental results.


Physics in Medicine and Biology | 2006

Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any x-ray imaging system

Alessandro Olivo; Robert D. Speller

Phase contrast (PC) imaging is one of the most exciting emerging x-ray imaging techniques, with the potential of removing some of the main limitations of conventional radiology. After extensive experimentation carried out particularly at synchrotron radiation (SR) facilities, the scientific community agrees that it is now time to translate these ideas towards the first clinical implementations. In this framework, a complete model, based on Fresnel/Kirchoff diffraction integrals, was devised. This model accounts for source dimensions, beam spectrum and divergence and detector point spread function (PSF), and can thus be applied to any x-ray imaging system. In particular, by accepting in input the above parameters along with the ones describing the sample, the model can be used to optimize the geometry of the set-up, i.e. to assess the source-to-sample and sample-to-detector distances which maximize feature detection. The model was evaluated by acquiring a range of images of different samples with a laboratory source, and a good agreement was found between simulated and experimental data in all cases. In order to maximize the generality of the results, all acquisitions were carried out using a polychromatic source and an energy-resolving detector; in this way, a range of monochromatic images could be obtained as well as polychromatic images, which can be created by integrating different parts of the acquired spectra. One of the most notable results obtained is that in many practical cases polychromatic PC imaging can provide the same image quality as its monochromatic counterpart. This is an important step in the wider application of PC using conventional sources.


Applied Optics | 2011

Noninterferometric phase-contrast images obtained with incoherent x-ray sources

Alessandro Olivo; Konstantin Ignatyev; P. Munro; Robert D. Speller

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the methods potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times-all important aspects with regards to real-world implementations.


Optics Express | 2010

The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems

P. Munro; Konstantin Ignatyev; Robert D. Speller; Alessandro Olivo

X-ray phase contrast imaging is a very promising technique which may lead to significant advancements in medical imaging. One of the impediments to the clinical implementation of the technique is the general requirement to have an x-ray source of high coherence. The radiation physics group at UCL is currently developing an x-ray phase contrast imaging technique which works with laboratory x-ray sources. Validation of the system requires extensive modelling of relatively large samples of tissue. To aid this, we have undertaken a study of when geometrical optics may be employed to model the system in order to avoid the need to perform a computationally expensive wave optics calculation. In this paper, we derive the relationship between the geometrical and wave optics model for our system imaging an infinite cylinder. From this model we are able to draw conclusions regarding the general applicability of the geometrical optics approximation.

Collaboration


Dive into the Alessandro Olivo's collaboration.

Top Co-Authors

Avatar

Marco Endrizzi

University College London

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Paul C. Diemoz

University College London

View shared research outputs
Top Co-Authors

Avatar

S. Pani

University of Surrey

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge