Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Alexander Schaudinn is active.

Publication


Featured researches published by Alexander Schaudinn.


PLOS ONE | 2014

Non-Invasive Assessment of Hepatic Steatosis in Patients with NAFLD Using Controlled Attenuation Parameter and 1H-MR Spectroscopy

Thomas Karlas; David Petroff; Nikita Garnov; Stephan H. Bohm; Hannelore Tenckhoff; Christian Wittekind; Manfred Wiese; Ingolf Schiefke; Nicolas Linder; Alexander Schaudinn; Harald Busse; Thomas Kahn; Joachim Mössner; T. Berg; Michael Tröltzsch; Volker Keim; Johannes Wiegand

Introduction Non-invasive assessment of steatosis and fibrosis is of growing relevance in non-alcoholic fatty liver disease (NAFLD). 1H-Magnetic resonance spectroscopy (1H-MRS) and the ultrasound-based controlled attenuation parameter (CAP) correlate with biopsy proven steatosis, but have not been correlated with each other so far. We therefore performed a head-to-head comparison between both methods. Methods Fifty patients with biopsy-proven NAFLD and 15 healthy volunteers were evaluated with 1H-MRS and transient elastography (TE) including CAP. Steatosis was defined according to the percentage of affected hepatocytes: S1 5-33%, S2 34–66%, S3 ≥67%. Results Steatosis grade in patients with NAFLD was S1 36%, S2 40% and S3 24%. CAP and 1H-MRS significantly correlated with histopathology and showed comparable accuracy for the detection of hepatic steatosis: areas under the receiver-operating characteristics curves were 0.93 vs. 0.88 for steatosis ≥S1 and 0.94 vs. 0.88 for ≥S2, respectively. Boot-strapping analysis revealed a CAP cut-off of 300 dB/m for detection of S2-3 steatosis, while retaining the lower cut-off of 215 dB/m for the definition of healthy individuals. Direct comparison between CAP and 1H-MRS revealed only modest correlation (total cohort: r = 0.63 [0.44, 0.76]; NAFLD cases: r = 0.56 [0.32, 0.74]). For detection of F2–4 fibrosis TE had sensitivity and specificity of 100% and 98.1% at a cut-off value of 8.85 kPa. Conclusion Our data suggest a comparable diagnostic value of CAP and 1H-MRS for hepatic steatosis quantification. Combined with the simultaneous TE fibrosis assessment, CAP represents an efficient method for non-invasive characterization of NAFLD. Limited correlation between CAP and 1H-MRS may be explained by different technical aspects, anthropometry, and presence of advanced liver fibrosis.


NMR in Biomedicine | 2015

Predictive accuracy of single‐ and multi‐slice MRI for the estimation of total visceral adipose tissue in overweight to severely obese patients

Alexander Schaudinn; Nicolas Linder; Nikita Garnov; Felix Kerlikowsky; Matthias Blüher; Arne Dietrich; Tatjana Schütz; Thomas Karlas; Thomas Kahn; Harald Busse

The quantification of visceral adipose tissue (VAT) is increasingly being considered for risk assessment and treatment monitoring in obese patients, but is generally time‐consuming. The goals of this work were to semi‐automatically segment and quantify VAT areas of MRI slices at previously proposed anatomical landmarks and to evaluate their predictive power for whole‐abdominal VAT volumes on a relatively large number of patients. One‐hundred and ninety‐seven overweight to severely obese patients (65 males; body mass index, 33.3 ± 3.5 kg/m2; 132 females; body mass index, 34.3 ± 3.2 kg/m2) underwent MRI examination. Total VAT volumes (VVAT‐T) of the abdominopelvic cavity were quantified by retrospective analysis of two‐point Dixon MRI data (active‐contour segmentation, visual correction and histogram analysis). VVAT‐T was then compared with VAT areas determined on one or five slices defined at seven anatomical landmarks (lumbar intervertebral spaces, umbilicus and femoral heads) and corresponding conversion factors were determined. Statistical measures were the coefficients of variation and standard deviations σ1 and σ5 of the difference between predicted and measured VAT volumes (Bland–Altman analysis). VVAT‐T was 6.0 ± 2.0 L (2.5–11.2 L) for males and 3.2 ± 1.4 L (0.9–7.7 L) for females. The analysis of five slices yielded a better agreement than the analysis of single slices, required only a little extra time (4 min versus 2 min) and was substantially faster than whole‐abdominal assessment (24 min). Best agreements were found at intervertebral spaces L3–L4 for females (σ5/1 = 523/608 mL) and L2–L3 for males (σ5/1 = 613/706 mL). Five‐slice VAT volume estimates at the level of lumbar disc L3–L4 for females and L2–L3 for males can be obtained within 4 min and were a reliable predictor for abdominopelvic VAT volume in overweight to severely adipose patients. One‐slice estimates took only 2 min and were slightly less accurate. These findings may contribute to the implementation of analytical methods for fast and reliable (routine) estimation of VAT volumes in obese patients. Copyright


World Journal of Gastroenterology | 2015

Estimating steatosis and fibrosis: Comparison of acoustic structure quantification with established techniques.

Thomas Karlas; Joachim Berger; Nikita Garnov; Franziska Lindner; Harald Busse; Nicolas Linder; Alexander Schaudinn; Bettina Relke; Rima Chakaroun; Michael Tröltzsch; Johannes Wiegand; Volker Keim

AIM To compare ultrasound-based acoustic structure quantification (ASQ) with established non-invasive techniques for grading and staging fatty liver disease. METHODS Type 2 diabetic patients at risk of non-alcoholic fatty liver disease (n = 50) and healthy volunteers (n = 20) were evaluated using laboratory analysis and anthropometric measurements, transient elastography (TE), controlled attenuation parameter (CAP), proton magnetic resonance spectroscopy ((1)H-MRS; only available for the diabetic cohort), and ASQ. ASQ parameters mode, average and focal disturbance (FD) ratio were compared with: (1) the extent of liver fibrosis estimated from TE and non-alcoholic fatty liver disease (NAFLD) fibrosis scores; and (2) the amount of steatosis, which was classified according to CAP values. RESULTS Forty-seven diabetic patients (age 67.0 ± 8.6 years; body mass index 29.4 ± 4.5 kg/m²) with reliable CAP measurements and all controls (age 26.5 ± 3.2 years; body mass index 22.0 ± 2.7 kg/m²) were included in the analysis. All ASQ parameters showed differences between healthy controls and diabetic patients (P < 0.001, respectively). The ASQ FD ratio (logarithmic) correlated with the CAP (r = -0.81, P < 0.001) and (1)H-MRS (r = -0.43, P = 0.004) results. The FD ratio [CAP < 250 dB/m: 107 (102-109), CAP between 250 and 300 dB/m: 106 (102-114); CAP between 300 and 350 dB/m: 105 (100-112), CAP ≥ 350 dB/m: 102 (99-108)] as well as mode and average parameters, were reduced in cases with advanced steatosis (ANOVA P < 0.05). However, none of the ASQ parameters showed a significant difference in patients with advanced fibrosis, as determined by TE and the NAFLD fibrosis score (P > 0.08, respectively). CONCLUSION ASQ parameters correlate with steatosis, but not with fibrosis in fatty liver disease. Steatosis estimation with ASQ should be further evaluated in biopsy-controlled studies.


PLOS ONE | 2015

Evaluation of Transient Elastography, Acoustic Radiation Force Impulse Imaging (ARFI), and Enhanced Liver Function (ELF) Score for Detection of Fibrosis in Morbidly Obese Patients.

Thomas Karlas; Arne Dietrich; Veronica Peter; Christian Wittekind; Ralf Lichtinghagen; Nikita Garnov; Nicolas Linder; Alexander Schaudinn; Harald Busse; Christiane Prettin; Volker Keim; Michael Tröltzsch; Tatjana Schütz; Johannes Wiegand

Background Liver fibrosis induced by non-alcoholic fatty liver disease causes peri-interventional complications in morbidly obese patients. We determined the performance of transient elastography (TE), acoustic radiation force impulse (ARFI) imaging, and enhanced liver fibrosis (ELF) score for fibrosis detection in bariatric patients. Patients and Methods 41 patients (median BMI 47 kg/m2) underwent 14-day low-energy diets to improve conditions prior to bariatric surgery (day 0). TE (M and XL probe), ARFI, and ELF score were performed on days -15 and -1 and compared with intraoperative liver biopsies (NAS staging). Results Valid TE and ARFI results at day -15 and -1 were obtained in 49%/88% and 51%/90% of cases, respectively. High skin-to-liver-capsule distances correlated with invalid TE measurements. Fibrosis of liver biopsies was staged as F1 and F3 in n = 40 and n = 1 individuals. However, variations (median/range at d-15/-1) of TE (4.6/2.6–75 and 6.7/2.9–21.3 kPa) and ARFI (2.1/0.7–3.7 and 2.0/0.7–3.8 m/s) were high and associated with overestimation of fibrosis. The ELF score correctly classified 87.5% of patients. Conclusion In bariatric patients, performance of TE and ARFI was poor and did not improve after weight loss. The ELF score correctly classified the majority of cases and should be further evaluated.


Scientific Reports | 2017

Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate

Josephin Gawlitza; Martin Reiss-Zimmermann; G Thörmer; Alexander Schaudinn; Nicolas Linder; Nikita Garnov; Lars-Christian Horn; Do Minh; Roman Ganzer; Jens-Uwe Stolzenburg; Thomas Kahn; Michael Moche; Harald Busse

This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.


NMR in Biomedicine | 2014

Comparison of T1 relaxation times in adipose tissue of severely obese patients and healthy lean subjects measured by 1.5 T MRI

Nikita Garnov; Nicolas Linder; Alexander Schaudinn; Matthias Blüher; Thomas Karlas; Tatjana Schütz; Arne Dietrich; Thomas Kahn; Harald Busse

Subcutaneous (SAT) and visceral adipose tissue (VAT) differ in composition, endocrine function and localization in the body. VAT is considered to play a role in the pathogenesis of insulin resistance, type 2 diabetes, fatty liver disease, and other obesity‐related disorders. It has been shown that the amount, distribution, and (cellular) composition of adipose tissue (AT) correlate well with metabolic conditions. In this study, T1 relaxation times of AT were measured in severely obese subjects and compared with those of healthy lean controls. Here, we tested the hypothesis that T1 relaxation times of AT differ between lean and obese individuals, but also between VAT and SAT as well as superficial (sSAT) and deep SAT (dSAT) in the same individual.


Scientific Reports | 2016

Age and gender specific estimation of visceral adipose tissue amounts from radiological images in morbidly obese patients.

Nicolas Linder; Alexander Schaudinn; Nikita Garnov; Matthias Blüher; Arne Dietrich; Tatjana Schütz; Stefanie Lehmann; Ulf Retschlag; Thomas Karlas; Thomas Kahn; Harald Busse

Image-based quantifications of visceral adipose tissue (VAT) volumes from segmented VAT areas are increasingly considered for risk assessment in obese patients. The goal of this study was to determine the power of partial VAT areas to predict total VAT volume in morbidly obese patients (BMI > 40 kg/m2) as a function of gender, age and anatomical landmarks. 130 morbidly obese patients (mean BMI 46.5 kg/m2; 94 females) underwent IRB-approved MRI. Total VAT volumes were predicted from segmented VAT areas (of single or five adjacent slices) at common axial landmark levels and compared with the measured ones (VVAT-T, about 40 slices between diaphragm and pelvic floor). Standard deviations σ1 and σ5 of the respective VAT volume differences served as measures of agreement. Mean VVAT-T was 4.9 L for females and 8.1 L for males. Best predictions were found at intervertebral spaces L3-L4 for females (σ5 = 688 ml, σ1 = 832 ml) and L1-L2 for males (σ5 = 846 ml, σ1 = 992 ml), irrespective of age. In conclusion, VAT volumes in morbidly obese patients can be reliably predicted by multiplying the segmented VAT area at a gender-specific lumbar reference level with a fixed scaling factor and effective slice thickness.


Endocrine | 2017

Association of fetuin B with markers of liver fibrosis in nonalcoholic fatty liver disease

Thomas Ebert; Nicolas Linder; Alexander Schaudinn; Harald Busse; Joachim Berger; Ralf Lichtinghagen; Volker Keim; Johannes Wiegand; Thomas Karlas

ObjectiveThe liver-derived plasma protein fetuin B is associated with nonalcoholic fatty liver disease (NAFLD) and impaired glucose homeostasis in mice. However, its association with non-invasive ultrasound- and magnetic resonance (MR)-based markers of liver fibrosis and steatosis, the enhanced liver fibrosis (ELF) score, liver biopsy, as well as rs738409 in PNPLA3, has not been elucidated in NAFLD, so far.Design and methodsThe association of circulating fetuin B and transient elastography (TE), controlled attenuation parameter (CAP), 1H-MR-spectroscopy, the ELF score, liver biopsy, as well as risk alleles in rs738409 in PNPLA3, was studied in 101 NAFLD patients as compared to 15 healthy controls.ResultsSerum fetuin B levels did not differ between NAFLD patients and controls (p = 0.863). Fetuin B was independently and negatively associated with transient elastography liver stiffness measurement (LSM) (p = 0.002), but not with the steatosis markers CAP or 1H-MR-spectroscopy. Fetuin B serum concentrations were significantly lower in individuals with LSM > 7.0 kPa as compared to patients with LSM < 7.0 kPa (p = 0.024). Furthermore, the ELF score and histologically proven fibrosis were independent and negative predictors of circulating fetuin B. Moreover, serum fetuin B significantly depended on number of rs738409 risk alleles (p = 0.026).ConclusionsFetuin B is independently and negatively associated with non-invasive markers of liver fibrosis and PNPLA3 status in NAFLD patients but does not show a correlation with the hepatic lipid content. Future studies need to elucidate the pathophysiological significance of fetuin B in NAFLD and its potential value as predictor for disease severity.


BMC Infectious Diseases | 2017

Acute focal bacterial nephritis is associated with invasive diagnostic procedures - a cohort of 138 cases extracted through a systematic review

Nadine Sieger; Iason Kyriazis; Alexander Schaudinn; Panagiotis Kallidonis; Jochen Neuhaus; Evangelos Liatsikos; Roman Ganzer; Jens-Uwe Stolzenburg

BackgroundAcute focal bacterial nephritis (AFBN) is a rare disease currently described only in case reports and small case series. In this study we summarize the clinical features of AFBN as has been documented in the literature and draw recommendations on the proper diagnosis and therapy.MethodsA systematic literature review was undertaken in PUBMED, Web of Science and The Cochrane Library online databases for relevant literature on AFBN in adults.ResultsLiterature review revealed a total of 38 articles according to our inclusion criteria, of which we could extract data from 138 cases of AFBN. Fever (98%) and flank pain (80%) were most commonly reported symptoms. E. coli was the most frequent pathogen. Diagnosis was set by CT and/or MRI (52%) with or without sonography or by sonography alone (20%) as well as by sonography combined with IVU. In total, sonography was applied in 83% of cases. All but one patient received antibiotic treatment. Kidney lesions were occasionally mistaken for neoplasms or renal abscesses and as a result, cases were subjected to percutaneous puncture (12.3%), surgical exploration (5.1%) and partial or radical nephrectomy (4.4%). Four cases (2.9%) developed a renal abscess.ConclusionsThe diagnosis of AFBN is set by characteristic clinico-radiological findings. Differential diagnoses of this interstitial bacterial infection include renal abscess and tumor. Correct diagnosis is occasionally impeded by atypical symptoms. Invasive diagnostic and therapeutic procedures should be limited as the majority of cases respond well to conservative treatment.


PLOS ONE | 2018

Dicomflex: A novel framework for efficient deployment of image analysis tools in radiological research

Roland Stange; Nicolas Linder; Alexander Schaudinn; Thomas Kahn; Harald Busse

Objective Medical image processing tools in research are often developed from scratch without the use of predefined software structures, which potentially makes them less reliable and difficult to maintain. The objective here was to present and evaluate a novel framework (Dicomflex) for the deployment of tools with a uniform workflow, commonly encountered in medical image analysis. Materials and methods The object-oriented code was developed using Matlab. Dicomflex applications follow the common workflow of image-slice selection, user interaction, image processing, result visualization and progression to next slice. The framework consists of three important classes that host functionality, two configuration files and a front end that displays images, graphs and resulting data. Results So far, three different research tools have been created under the new framework. In comparison with previous Matlab analysis tools used at our institution, users of Dicomflex tools subjectively considered the learning phase to be shorter and handling to be simpler and more intuitive. They also highlighted the benefit and comfort of the standardized interface and predefined workflow. The framework-inherent handling of software versions was considered highly beneficial for maintenance as well as data and software management at different project stages. The clear separation of framework-related and unrelated code allows for a fast and more direct design of new tools in well-defined steps. The flexibility of the framework translates to a wide range of image processing tasks, such as segmentation, region-of-interest (ROI) analyses or computation of functional parameter maps, but is limited to 2D datasets. Conclusion Potential medical applications include the assessment of cardiac performance, detection of cerebrovascular disease or characterization of cancerous lesions. Dicomflex tools share a similar workflow and host the pertinent functions only. This may be relevant for many image processing needs in radiological research, where quick software deployment and reliability of results is essential.

Collaboration


Dive into the Alexander Schaudinn's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge