Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Alexia Rossi is active.

Publication


Featured researches published by Alexia Rossi.


Radiology | 2014

Stress Myocardial Perfusion: Imaging with Multidetector CT

Alexia Rossi; Daphne Merkus; Ernst Klotz; Nico R. Mollet; Pim J. de Feyter; Gabriel P. Krestin

Computed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required because both anatomic and functional information is needed for guiding patient care. Recent developments in CT technology allow CT evaluation of myocardial perfusion during vasodilator stress, thereby providing information about myocardial ischemia. Investigators in several single-center studies have established the feasibility of performing stress myocardial perfusion CT imaging in small groups of patients and have shown that stress myocardial perfusion CT in combination with CT coronary angiography improved the diagnostic accuracy in comparison with CT coronary angiography alone. However, CT perfusion acquisition protocols must be optimized in terms of acquisition and reconstruction parameters, contrast material protocol injections, and radiation dose. Further research is needed to establish the clinical usefulness of this novel technique. The purpose of this review is to (a) provide an overview of the physiology of coronary circulation and myocardial perfusion; (b) describe the technical prerequisites, challenges, and mathematic modeling related to CT perfusion imaging; (c) note recent advances in CT scanners and CT perfusion protocols; and (d) discuss the interpretation of CT perfusion images. Finally, a review and summary of the current literature are provided, and future directions for research are discussed.


European Journal of Echocardiography | 2014

Diagnostic performance of hyperaemic myocardial blood flow index obtained by dynamic computed tomography: does it predict functionally significant coronary lesions?

Alexia Rossi; Anoeshka S. Dharampal; Andrew Wragg; L. Ceri Davies; Robert-Jan van Geuns; Costantinos Anagnostopoulos; Ernst Klotz; Pieter H. Kitslaar; Alexander Broersen; Anthony Mathur; Koen Nieman; M. G. Myriam Hunink; Pim J. de Feyter; Steffen E. Petersen; Francesca Pugliese

AIMSnThe severity of coronary artery narrowing is a poor predictor of functional significance, in particular in intermediate coronary lesions (30-70% diameter narrowing). The aim of this work was to compare the performance of a quantitative hyperaemic myocardial blood flow (MBF) index derived from adenosine dynamic computed tomography perfusion (CTP) imaging with that of visual CT coronary angiography (CTCA) and semi-automatic quantitative CT (QCT) in the detection of functionally significant coronary lesions in patients with stable chest pain.nnnMETHODS AND RESULTSnCTCA and CTP were performed in 80 patients (210 analysable coronary vessels) referred to invasive coronary angiography (ICA). The MBF index (mL/100 mL/min) was computed using a model-based parametric deconvolution method. The diagnostic performance of the MBF index in detecting functionally significant coronary lesions was compared with visual CTCA and QCT. Coronary lesions with invasive fractional flow reserve of ≤0.75 were defined as functionally significant. The optimal cut-off value of the MBF index to detect functionally significant coronary lesions was 78 mL/100 mL/min. On a vessel-territory level, the MBF index had a larger area under the curve (0.95; 95% confidence interval [95% CI]: 0.92-0.98) compared with visual CTCA (0.85; 95% CI: 0.79-0.91) and QCT (0.89; 95% CI: 0.84-0.93) (both P-values <0.001). In the analysis restricted to intermediate coronary lesions, the specificity of visual CTCA (69%) and QCT (77%) could be improved by the subsequent use of the MBF index (89%).nnnCONCLUSIONnIn this proof-of-principle study, the MBF index performed better than visual CTCA and QCT in the identification of functionally significant coronary lesions. The MBF index had additional value beyond CTCA anatomy in intermediate coronary lesions. This may have a potential to support patient management.


Eurointervention | 2011

Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis

Carl Schultz; Alexia Rossi; Nicolas M. Van Mieghem; Robert M.A. van der Boon; Stella-Lida Papadopoulou; Ron T. van Domburg; Adriaan Moelker; Nico R. Mollet; Gabriel P. Krestin; Robert-Jan van Geuns; Koen Nieman; Pim J. de Feyter; Patrick W. Serruys; Peter de Jaegere

AIMSnWe compared the measurement of aortic leaflet calcification on contrast and non-contrast MSCT and investigated predictors of the need for balloon post-dilatation after TAVI.nnnMETHODS AND RESULTSnIn 110 patients, who had TAVI with a Medtronic CoreValve prosthesis (MCS) for symptomatic aortic stenosis, calcification of the aortic root was measured on non-contrast MSCT (conventionally) and on contrast MSCT (signal attenuation >450 Houndsfield units). Calcium volume was underestimated on contrast- when compared to non-contrast MSCT: median (IQ-range)=759 (466 to 1295) vs. 2016 (1376 to 3262) and the difference between the two methods increased with higher calcium volumes (correlation coefficient r=0.90). Calcium mass was only slightly underestimated on contrast vs. non-contrast MSCT: median (IQ-range)=441 (268 to 809) vs. 555 (341 to 950) and there was no association between the differences and increasing calcium mass (r=0.17). Balloon post-dilatation was performed for significant aortic regurgitation after TAVI in 11 of 110 patients. When compared to controls, the patients who required balloon post-dilatation had higher aortic leaflet calcium on contrast CT (p<0.01), higher aortic annulus diameters (p<0.01) and higher annulus to prosthesis area ratio (p=0.01). ROC curves demonstrated that aortic root or aortic leaflet calcium measured on either contrast- or non-contrast MSCT showed excellent discrimination for the requirement of balloon post-dilatation (area under ROC >0.80 for all), whereas the discriminatory value of aortic annulus dimensions was moderate (area under ROC=0.69) and that of prosthesis to annulus ratio was poor (area under ROC=0.36).nnnCONCLUSIONSnDense aortic leaflet calcification measured on contrast MSCT discerned well the need for balloon post-dilatation after TAVI with an MCS for significant PAR. Non-contrast MSCT may no longer be needed to quantify aortic root calcium before TAVI.


Jacc-cardiovascular Imaging | 2012

Natural history of coronary atherosclerosis by multislice computed tomography.

Stella-Lida Papadopoulou; Lisan A. Neefjes; Hector M. Garcia-Garcia; Willem-Jan Flu; Alexia Rossi; Anoeshka S. Dharampal; Pieter H. Kitslaar; Nico R. Mollet; Susan Veldhof; Koen Nieman; Gregg W. Stone; Patrick W. Serruys; Gabriel P. Krestin; Pim J. de Feyter

OBJECTIVESnThis study sought to analyze the natural history of coronary atherosclerosis by multislice computed tomography (MSCT) and assess the serial changes in coronary plaque burden, lumen dimensions, and arterial remodeling.nnnBACKGROUNDnMSCT can comprehensively assess coronary atherosclerosis by combining lumen and plaque size parameters.nnnMETHODSnThirty-two patients with acute coronary syndromes underwent 64-slice computed tomography angiography after percutaneous coronary intervention at baseline and after a median of 39 months. All patients received contemporary medical treatment. All available coronary segments in every subject were analyzed. The progression of atherosclerosis per segment and per patient was assessed by means of change in percent atheroma volume (PAV), change in normalized total atheroma volume (TAVnorm), and percent change in TAV (% change in TAV). Serial coronary remodeling was also assessed. Measures of lumen stenosis included percent diameter stenosis (%DS), minimum lumen diameter (MLD), percent area stenosis (%AS), and minimum lumen area (MLA). For each patient, the mean of all matched segments was calculated at the 2 time points. Clinical events at follow-up were documented.nnnRESULTSnThe PAV did not change significantly (-0.15 ± 3.64%, p = 0.72). The mean change in TAVnorm was 47.36 ± 143.24 mm(3) (p = 0.071), and the % change in TAV was 6.7% (p = 0.029). The MLD and MLA increased by 0.15 mm (-0.09 to 0.24, p = 0.039) and 0.52 mm(2) (-0.38 to 1.04, p = 0.034) respectively, which was accompanied by vessel enlargement, with 53% of the patients showing expansive positive remodeling. Patients with clinical events had a larger TAVnorm at baseline (969.72 mm(3) vs. 810.77 mm(3), p = 0.010).nnnCONCLUSIONSnMSCT can assess the progression of coronary atherosclerosis and may be used for noninvasive monitoring of pharmacological interventions in coronary artery disease. (nnnPROSPECTnAn Imaging Study in Patients With Unstable Atherosclerotic Lesions; NCT00180466).


Radiology | 2011

Image Quality and Radiation Exposure Using Different Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography: Randomized Study

Lisan A. Neefjes; Anoeshka S. Dharampal; Alexia Rossi; Koen Nieman; Annick C. Weustink; Marcel L. Dijkshoorn; Gert-Jan R. ten Kate; Admir Dedic; Stella L. Papadopoulou; Marcel van Straten; Filippo Cademartiri; Gabriel P. Krestin; Pim J. de Feyter; Nico R. Mollet

PURPOSEnTo compare image quality, radiation dose, and their relationship with heart rate of computed tomographic (CT) coronary angiographic scan protocols by using a 128-section dual-source CT scanner.nnnMATERIALS AND METHODSnInstitutional review board approved the study; all patients gave informed consent. Two hundred seventy-two patients (175 men, 97 women; mean ages, 58 and 59 years, respectively) referred for CT coronary angiography were categorized according to heart rate: less than 65 beats per minute (group A) and 65 beats per minute or greater (group B). Patients were randomized to undergo prospective high-pitch spiral scanning and narrow-window prospective sequential scanning in group A (n = 160) or wide-window prospective sequential scanning and retrospective spiral scanning in group B (n = 112). Image quality was graded (1 = nondiagnostic; 2 = artifacts present, diagnostic; 3 = no artifacts) and compared (Mann-Whitney and Student t tests).nnnRESULTSnIn group A, mean image quality grade was significantly lower with high-pitch spiral versus sequential scanning (2.67 ± 0.38 [standard deviation] vs 2.86 ± 0.21; P < .001). In a subpopulation (heart rate, <55 beats per minute), mean image quality grade was similar (2.81 ± 0.30 vs 2.94 ± 0.08; P = .35). In group B, image quality grade was comparable between sequential and retrospective spiral scanning (2.81 ± 0.28 vs 2.80 ± 0.38; P = .54). Mean estimated radiation dose was significantly lower (high-pitch spiral vs sequential scanning) in group A (for 100 kV, 0.81 mSv ± 0.30 vs 2.74 mSv ± 1.14 [P < .001]; for 120 kV, 1.65 mSv ± 0.69 vs 4.21 mSv ± 1.20 [P < .001]) and in group B (sequential vs retrospective spiral scanning) (for 100 kV, 4.07 mSv ± 1.07 vs 5.54 mSv ± 1.76 [P = .02]; for 120 kV, 7.50 mSv ± 1.79 vs 9.83 mSv ± 3.49 [P = .1]).nnnCONCLUSIONnA high-pitch spiral CT coronary angiographic protocol should be applied in patients with regular and low (<55 beats per minute) heart rates; a sequential protocol is preferred in all others.


European Journal of Echocardiography | 2013

Quantification of myocardial blood flow by adenosine-stress CT perfusion imaging in pigs during various degrees of stenosis correlates well with coronary artery blood flow and fractional flow reserve

Alexia Rossi; André Uitterdijk; Marcel L. Dijkshoorn; Ernst Klotz; Anoeshka S. Dharampal; Marcel van Straten; Wim J. van der Giessen; Nico R. Mollet; Robert-Jan van Geuns; Gabriel P. Krestin; Dirk J. Duncker; Pim J. de Feyter; Daphne Merkus

AIMSnOnly few preliminary experimental studies demonstrated the feasibility of adenosine stress CT myocardial perfusion imaging to calculate the absolute myocardial blood flow (MBF), thereby providing information whether a coronary stenosis is flow limiting. Therefore, the aim of our study was to determine whether adenosine stress myocardial perfusion imaging by Dual Source CT (DSCT) enables non-invasive quantification of regional MBF in an animal model with various degrees of coronary flow reduction.nnnMETHODS AND RESULTSnIn seven pigs, a coronary flow probe and an adjustable hydraulic occluder were placed around the left anterior descending coronary artery to monitor the distal coronary artery blood flow (CBF) while several degrees of coronary flow reduction were induced. CT perfusion (CT-MBF) was acquired during adenosine stress with no CBF reduction, an intermediate (15-39%) and a severe (40-95%) CBF reduction. Reference standards were CBF and fractional flow reserve measurements (FFR). FFR was simultaneously derived from distal coronary artery pressure and aortic pressure measurements. CT-MBF decreased progressively with increasing CBF reduction severity from 2.68 (2.31-2.81)mL/g/min (normal CBF) to 1.96 (1.83-2.33) mL/g/min (intermediate CBF-reduction) and to 1.55 (1.14-2.06)mL/g/min (severe CBF-reduction) (both P < 0.001). We observed very good correlations between CT-MBF and CBF (r = 0.85, P < 0.001) and CT-MBF and FFR (r = 0.85, P < 0.001).nnnCONCLUSIONnAdenosine stress DSCT myocardial perfusion imaging allows quantification of regional MBF under various degrees of CBF reduction.


Journal of Cardiovascular Magnetic Resonance | 2011

Quantitative cardiovascular magnetic resonance in pregnant women: cross-sectional analysis of physiological parameters throughout pregnancy and the impact of the supine position.

Alexia Rossi; Jérôme Cornette; Mark R. Johnson; Yusuf Karamermer; Tirza Springeling; Petra Opic; Adriaan Moelker; Gabriel P. Krestin; Eric A.P. Steegers; Jolien W. Roos-Hesselink; Robert-Jan van Geuns

BackgroundThere are physiological reasons for the effects of positioning on hemodynamic variables and cardiac dimensions related to altered intra-abdominal and intra-thoracic pressures. This problem is especially evident in pregnant women due to the additional aorto-caval compression by the enlarged uterus. The purpose of this study was to investigate the effect of postural changes on cardiac dimensions and function during mid and late pregnancy using cardiovascular magnetic resonance (CMR).MethodsHealthy non-pregnant women, pregnant women at 20th week of gestation and at 32nd week of gestation without history of cardiac disease were recruited to the study and underwent CMR in supine and left lateral positions. Cardiac hemodynamic parameters and dimensions were measured and compared between both positions.ResultsFive non-pregnant women, 6 healthy pregnant women at mid pregnancy and 8 healthy pregnant women at late pregnancy were enrolled in the study. In the group of non-pregnant women left ventricular (LV) cardiac output (CO) significantly decreased by 9% (p = 0.043) and right ventricular (RV) end-diastolic volume (EDV) significantly increased by 5% (p = 0.043) from the supine to the left lateral position. During mid pregnancy LV ejection fraction (EF), stroke volume (SV), left atrium lateral diameter and left atrial supero-inferior diameter increased significantly from the supine position to the left lateral position: 8%, 27%, 5% and 11%, respectively (p < 0.05). RV EDV, SV and right atrium supero-inferior diameter significantly increased from the supine to the left lateral position: 25%, 31% and 13% (p < 0.05), respectively. During late pregnancy a significant increment of LV EF, EDV, SV and CO was observed in the left lateral position: 11%, 21%, 35% and 24% (p < 0.05), respectively. Left atrial diameters were significantly larger in the left lateral position compared to the supine position (p < 0.05). RV CO was significantly increased in the left lateral position compared to the supine position (p < 0.05).ConclusionsDuring pregnancy positional changes affect significantly cardiac hemodynamic parameters and dimensions. Pregnant women who need serial studies by CMR should be imaged in a consistent position. From as early as 20 weeks the left lateral position should be preferred on the supine position because it positively affects venous return, SV and CO.


International Journal of Cardiology | 2012

Combining magnetic resonance viability variables better predicts improvement of myocardial function prior to percutaneous coronary intervention

Sharon W. Kirschbaum; Alexia Rossi; Eric Boersma; Tirza Springeling; Martin van de Ent; Gabriel P. Krestin; Patrick W. Serruys; Dirk J. Duncker; Pim J. de Feyter; Robert-Jan van Geuns

OBJECTIVEnTo optimize the predictive value of cardiac magnetic resonance imaging (MRI) for improvement of myocardial dysfunction prior to percutaneous coronary intervention (PCI).nnnMETHODSnWe performed cardiac MRI in 72 patients (male 87%, age 60 years) before and 6 months after successful PCI (43/72) or unsuccessful PCI (29/72) of a chronic total coronary occlusion (CTO). Before PCI, 5 viability parameters were evaluated: transmural extent of infarction (TEI), contractile reserve during dobutamine, end diastolic wall thickness, unenhanced rim thickness and segmental wall thickening of the unenhanced rim (SWTur). Multivariate analysis was performed and based on the regression coefficient (RC) a predictive score was constructed. Diagnostic performance to predict improvement in myocardial function for each parameter and for the viability score was determined.nnnRESULTSnThe predictive value of a combination of contractile reserve, SWTur and TEI was incremental to TEI alone (AUROC 0.91 vs. 0.77; p<0.001). A viability score of ≥ 5 based on contractile reserve (RC=4), SWTur (RC=1) and TEI (RC=2) was 91% sensitive and 84% specific in predicting improvement of myocardial function.nnnCONCLUSIONnCombining viability parameters results in a better prediction of improvement of dysfunctional myocardial segments after a successful PCI.


Jacc-cardiovascular Imaging | 2013

CT-SYNTAX score: A feasibility and reproducibility study

Stella-Lida Papadopoulou; Chrysafios Girasis; Anoeshka S. Dharampal; Vasim Farooq; Yoshinobu Onuma; Alexia Rossi; Marie-Angèle Morel; Gabriel P. Krestin; Patrick W. Serruys; Pim J. de Feyter; Hector Garcia Garcia

The SYNTAX score (SXscore) ([1][1]) is an important tool to grade angiographic complexity and to risk-stratify patients being considered for revascularization; moreover, it has been reported as an independent predictor of major adverse cardiac events in all-comers–type populations with a varying


International Journal of Cardiovascular Imaging | 2013

Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies

Stella-Lida Papadopoulou; Hector M. Garcia-Garcia; Alexia Rossi; Chrysafios Girasis; Anoeshka S. Dharampal; Pieter H. Kitslaar; Gabriel P. Krestin; Pim J. de Feyter

Reproducibility of the quantitative assessment of atherosclerosis by computed tomography coronary angiography (CTCA) is paramount for the design of longitudinal studies. The purpose of this study was to assess the inter- and intra-observer reproducibility using semiautomated CT plaque analysis software in symptomatic individuals. CTCA was performed in 10 symptomatic patients after percutaneous treatment of the culprit lesions and was repeated after 3xa0years. The plaque quantitative analysis was performed in untreated vessels with mild-to-moderate atherosclerosis and included geometrical and compositional characteristics using semiautomated CT plaque analysis software. A total of 945 matched cross-sections from 21 segments were analyzed independently by a second reviewer to assess inter-observer variability; the first observer repeated all the analyses after 3xa0months to assess intra-observer variability. The observer variability was also compared to the absolute plaque changes detected over time. Agreement was evaluated by Bland–Altman analysis and concordance correlation coefficient. Inter-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.2, 0.6, 2.2, 1.6xa0% respectively. Intra-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.0, 0.4, 0.2, 0.4xa0% respectively. For the average plaque attenuation values the inter- and intra-observer variability was 5 and 2xa0% respectively. For the % low-attenuation-plaque the inter- and intra-observer variability was 16 and 6xa0% respectively. The absolute intra-observer variability for the plaque burden was 1.30xa0±xa01.09xa0%, while the temporal plaque burden difference was 3.55xa0±xa03.02xa0% (pxa0=xa00.001). The present study shows that the geometrical assessment of coronary atherosclerosis by CTCA is highly reproducible within and between observers using semiautomated quantification software and that serial plaque changes can be detected beyond observer variability. The compositional measurements are more variable between observers than geometrical measurements.

Collaboration


Dive into the Alexia Rossi's collaboration.

Top Co-Authors

Avatar

Pim J. de Feyter

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Gabriel P. Krestin

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Koen Nieman

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Robert-Jan van Geuns

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Francesca Pugliese

Queen Mary University of London

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nico R. Mollet

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marcel L. Dijkshoorn

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge