Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Allen Jordan is active.

Publication


Featured researches published by Allen Jordan.


Journal of Geophysical Research | 2014

Evaluation of UT/LS hygrometer accuracy by intercomparison during the NASA MACPEX mission

Andrew W. Rollins; Troy Thornberry; R. S. Gao; Jessica Smith; David Stuart Sayres; M. R. Sargent; C. Schiller; Martina Krämer; N. Spelten; D. F. Hurst; Allen Jordan; Emrys G. Hall; H. Vömel; Glenn S. Diskin; J. R. Podolske; Lance E. Christensen; Karen H. Rosenlof; Eric J. Jensen; D. W. Fahey

Acquiring accurate measurements of water vapor at the low mixing ratios (< 10 ppm) encountered in the upper troposphere and lower stratosphere (UT/LS) has proven to be a significant analytical challenge evidenced by persistent disagreements between high-precision hygrometers. These disagreements have caused uncertainties in the description of the physical processes controlling dehydration of air in the tropical tropopause layer and entry of water into the stratosphere and have hindered validation of satellite water vapor retrievals. A 2011 airborne intercomparison of a large group of in situ hygrometers onboard the NASA WB-57F high-altitude research aircraft and balloons has provided an excellent opportunity to evaluate progress in the scientific community toward improved measurement agreement. In this work we intercompare the measurements from the Midlatitude Airborne Cirrus Properties Experiment (MACPEX) and discuss the quality of agreement. Differences between values reported by the instruments were reduced in comparison to some prior campaigns but were nonnegligible and on the order of 20% (0.8 ppm). Our analysis suggests that unrecognized errors in the quantification of instrumental background for some or all of the hygrometers are a likely cause. Until these errors are understood, differences at this level will continue to somewhat limit our understanding of cirrus microphysical processes and dehydration in the tropical tropopause layer.


Journal of Geophysical Research | 2014

Validation of Aura Microwave Limb Sounder stratospheric water vapor measurements by the NOAA frost point hygrometer

D. F. Hurst; Alyn Lambert; William G. Read; Sean M. Davis; Karen H. Rosenlof; Emrys G. Hall; Allen Jordan; Samuel J. Oltmans

Differences between stratospheric water vapor measurements by NOAA frost point hygrometers (FPHs) and the Aura Microwave Limb Sounder (MLS) are evaluated for the period August 2004 through December 2012 at Boulder, Colorado, Hilo, Hawaii, and Lauder, New Zealand. Two groups of MLS profiles coincident with the FPH soundings at each site are identified using unique sets of spatiotemporal criteria. Before evaluating the differences between coincident FPH and MLS profiles, each FPH profile is convolved with the MLS averaging kernels for eight pressure levels from 100 to 26 hPa (~16 to 25 km) to reduce its vertical resolution to that of the MLS water vapor retrievals. The mean FPH - MLS differences at every pressure level (100 to 26 hPa) are well within the combined measurement uncertainties of the two instruments. However, the mean differences at 100 and 83 hPa are statistically significant and negative, ranging from -0.46 ± 0.22 ppmv (-10.3 ± 4.8%) to -0.10 ± 0.05 ppmv (-2.2 ± 1.2%). Mean differences at the six pressure levels from 68 to 26 hPa are on average 0.8% (0.04 ppmv), and only a few are statistically significant. The FPH - MLS differences at each site are examined for temporal trends using weighted linear regression analyses. The vast majority of trends determined here are not statistically significant, and most are smaller than the minimum trends detectable in this analysis. Except at 100 and 83 hPa, the average agreement between MLS retrievals and FPH measurements of stratospheric water vapor is better than 1%.


Atmospheric Measurement Techniques | 2016

Recent divergences in stratospheric water vapor measurements by frost pointhygrometers and the Aura Microwave Limb Sounder

D. F. Hurst; William G. Read; Holger Vömel; Henry B. Selkirk; Karen H. Rosenlof; Sean M. Davis; Emrys G. Hall; Allen Jordan; Samuel J. Oltmans

Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1% between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10% at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year−1 (0.6 to 1.5% year−1) from ~2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980–2010) average growth rate of stratospheric water vapor (~ 1% year−1) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP–MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.


Journal of Geophysical Research | 2017

First Reprocessing of Southern Hemisphere Additional Ozonesondes (SHADOZ) Ozone Profiles (1998–2016): 2. Comparisons With Satellites and Ground‐Based Instruments

Anne M. Thompson; Jacquelyn C. Witte; Chance W. Sterling; Allen Jordan; Bryan J. Johnson; Samuel J. Oltmans; Masatomo Fujiwara; Holger Vömel; M. Allaart; Ankie Piters; Gert J. R. Coetzee; Françoise Posny; Ernesto Corrales; Jorge Andres Diaz; Christian Félix; Ninong Komala; Nga Lai; H. T. Ahn Nguyen; Matakite Maata; Francis S. Mani; Zamuna Zainal; Shin-Ya Ogino; Francisco Paredes; Tercio Luiz Bezerra Penha; Francisco R. da Silva; Sukarni Sallons‐Mitro; Henry B. Selkirk; Francis J. Schmidlin; R. Stübi; Kennedy Thiongo

Abstract The Southern Hemisphere ADditional OZonesonde (SHADOZ) network was assembled to validate a new generation of ozone-monitoring satellites and to better characterize the vertical structure of tropical ozone in the troposphere and stratosphere. Beginning with nine stations in 1998, more than 7,000 ozone and P-T-U profiles are available from 14 SHADOZ sites that have operated continuously for at least a decade. We analyze ozone profiles from the recently reprocessed SHADOZ data set that is based on adjustments for inconsistencies caused by varying ozonesonde instruments and operating techniques. First, sonde-derived total ozone column amounts are compared to the overpasses from the Earth Probe/Total Ozone Mapping Spectrometer, Ozone Monitoring Instrument, and Ozone Mapping and Profiler Suite satellites that cover 1998-2016. Second, characteristics of the stratospheric and tropospheric columns are examined along with ozone structure in the tropical tropopause layer (TTL). We find that (1) relative to our earlier evaluations of SHADOZ data, in 2003, 2007, and 2012, sonde-satellite total ozone column offsets at 12 stations are 2% or less, a significant improvement; (2) as in prior studies, the 10 tropical SHADOZ stations, defined as within ±19° latitude, display statistically uniform stratospheric column ozone, 229 ± 3.9 DU (Dobson units), and a tropospheric zonal wave-one pattern with a 14 DU mean amplitude; (3) the TTL ozone column, which is also zonally uniform, masks complex vertical structure, and this argues against using satellites for lower stratospheric ozone trends; and (4) reprocessing has led to more uniform stratospheric column amounts across sites and reduced bias in stratospheric profiles. As a consequence, the uncertainty in total column ozone now averages 5%.


Atmospheric Measurement Techniques | 2016

Advancements, measurement uncertainties, and recent comparisons of the NOAAfrost point hygrometer

Emrys G. Hall; Allen Jordan; D. F. Hurst; Samuel J. Oltmans; Holger Vömel; Benjamin Kühnreich; Volker Ebert

The NOAA frost point hygrometer (FPH) is a balloon-borne instrument flown monthly at three sites to measure water vapor profiles up to 28 km. The FPH record from Boulder, Colorado, is the longest continuous stratospheric water vapor record. The instrument has an uncertainty in the stratosphere that is < 6 % and up to 12 % in the troposphere. A digital microcontroller version of the instrument improved upon the older versions in 2008 with sunlight filtering, better frost control, and resistance to radio frequency interference (RFI). A new thermistor calibration technique was implemented in 2014, decreasing the uncertainty in the thermistor calibration fit to less than 0.01 °C over the full range of frost – or dew point temperatures (−93 to +20 °C) measured during a profile. Results from multiple water vapor intercomparisons are presented, including the excellent agreement between the NOAA FPH and the direct tunable diode laser absorption spectrometer (dTDLAS) MC-PicT-1.4 during AquaVIT-2 chamber experiments over 6 days that provides confidence in the accuracy of the FPH measurements. Dual instrument flights with two FPHs or an FPH and a cryogenic frost point hygrometer (CFH) also show good agreement when launched on the same balloon. The results from these comparisons demonstrate the high level of accuracy of the NOAA FPH.


Atmospheric Measurement Techniques Discussions | 2017

Homogenizing and Estimating the Uncertainty in NOAA’s Long Term Vertical Ozone Profile Records Measured with the Electrochemical Concentration Cell Ozonesonde

Chance W. Sterling; Bryan J. Johnson; Samuel J. Oltmans; H. G. J. Smit; Allen Jordan; Patrick D. Cullis; Emrys G. Hall; Anne M. Thompson; Jacquelyn C. Witte

NOAA’s program of long-term monitoring of the vertical distribution of ozone with electrochemical concentration cell (ECC) ozonesondes has undergone a number of changes over the 50-year record. In order to produce a homogenous data set, these changes must be documented and, where necessary, appropriate corrections applied. This is the first comprehensive and consistent reprocessing of NOAA’s ozonesonde data records that corrects for these changes using the rawest form of the data (cell current and pump temperature) in native resolution as well as a point-by-point uncertainty calculation that is unique to each sounding. The reprocessing is carried out uniformly at all eight ozonesonde sites in NOAA’s network with differences in sensing solution and ozonesonde types accounted for in the same way at all sites. The corrections used to homogenize the NOAA ozonesonde data records greatly improve the ozonesonde measurements with an average one sigma uncertainty of ±4–6 % in the stratosphere and ±5–20 % in the troposphere. A comparison of the integrated column ozone from the ozonesonde profile with co-located Dobson spectrophotometers total column ozone measurements shows agreement within ±5 % for > 70 % of the profiles. Very good agreement is also found in the stratosphere between ozonesonde profiles and profiles retrieved from the Solar Backscatter Ultraviolet (SBUV) instruments.


Atmospheric Measurement Techniques | 2016

Controlled weather balloon ascents and descents for atmospheric research and climate monitoring

Andreas Kräuchi; Rolf Philipona; Gonzague Romanens; D. F. Hurst; Emrys G. Hall; Allen Jordan

In situ upper-air measurements are often made with instruments attached to weather balloons launched at the surface and lifted into the stratosphere. Present-day balloon-borne sensors allow near-continuous measurements from the Earths surface to about 35 km (3-5 hPa), where the balloons burst and their instrument payloads descend with parachutes. It has been demonstrated that ascending weather balloons can perturb the air measured by very sensitive humidity and temperature sensors trailing behind them, particularly in the upper troposphere and lower stratosphere (UTLS). The use of controlled balloon descent for such measurements has therefore been investigated and is described here. We distinguish between the single balloon technique that uses a simple automatic valve system to release helium from the balloon at a preset ambient pressure, and the double balloon technique that uses a carrier balloon to lift the payload and a parachute balloon to control the descent of instruments after the carrier balloon is released at preset altitude. The automatic valve technique has been used for several decades for water vapor soundings with frost point hygrometers, whereas the double balloon technique has recently been re-established and deployed to measure radiation and temperature profiles through the atmosphere. Double balloon soundings also strongly reduce pendulum motion of the payload, stabilizing radiation instruments during ascent. We present the flight characteristics of these two ballooning techniques and compare the quality of temperature and humidity measurements made during ascent and descent.


Journal of Geophysical Research | 2011

Stratospheric water vapor trends over Boulder, Colorado: Analysis of the 30 year Boulder record

D. F. Hurst; Samuel J. Oltmans; H. Vömel; Karen H. Rosenlof; Sean M. Davis; Eric A. Ray; Emrys G. Hall; Allen Jordan


Atmospheric Measurement Techniques | 2011

Measurements of Humidity in the Atmosphere and Validation Experiments (MOHAVE)-2009: overview of campaign operations and results

Thierry Leblanc; T. D. Walsh; I. S. McDermid; G. C. Toon; J.-F. Blavier; B. Haines; William G. Read; B. Herman; Eric J. Fetzer; Stanley P. Sander; T. Pongetti; David N. Whiteman; T. G. Mcgee; Laurence Twigg; Grant Sumnicht; Demetrius Venable; M. Calhoun; Afusat Dirisu; D. F. Hurst; Allen Jordan; Emrys G. Hall; L. Miloshevich; H. Vömel; Corinne Straub; Niklaus Kämpfer; Gerald E. Nedoluha; R.M. Gomez; K. Holub; S. Gutman; John J. Braun


Atmospheric Measurement Techniques | 2011

Comparisons of temperature, pressure and humidity measurements by balloon-borne radiosondes and frost point hygrometers during MOHAVE-2009

D. F. Hurst; Emrys G. Hall; Allen Jordan; Larry M. Miloshevich; David N. Whiteman; Thierry Leblanc; D. Walsh; H. Vömel; Samuel J. Oltmans

Collaboration


Dive into the Allen Jordan's collaboration.

Top Co-Authors

Avatar

Emrys G. Hall

Cooperative Institute for Research in Environmental Sciences

View shared research outputs
Top Co-Authors

Avatar

Samuel J. Oltmans

Cooperative Institute for Research in Environmental Sciences

View shared research outputs
Top Co-Authors

Avatar

Karen H. Rosenlof

National Oceanic and Atmospheric Administration

View shared research outputs
Top Co-Authors

Avatar

Anne M. Thompson

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

Chance W. Sterling

National Oceanic and Atmospheric Administration

View shared research outputs
Top Co-Authors

Avatar

Jacquelyn C. Witte

Goddard Space Flight Center

View shared research outputs
Top Co-Authors

Avatar

H. Vömel

Deutscher Wetterdienst

View shared research outputs
Top Co-Authors

Avatar

Holger Vömel

National Center for Atmospheric Research

View shared research outputs
Top Co-Authors

Avatar

Sean M. Davis

Cooperative Institute for Research in Environmental Sciences

View shared research outputs
Top Co-Authors

Avatar

William G. Read

California Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge