Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ana M. Afonso is active.

Publication


Featured researches published by Ana M. Afonso.


Talanta | 2010

Dispersive liquid-liquid microextraction versus single-drop microextraction for the determination of several endocrine-disrupting phenols from seawaters.

Jessica López-Darias; Mónica Germán-Hernández; Verónica Pino; Ana M. Afonso

Two liquid-phase microextraction procedures: single-drop microextraction (SDME) and dispersive liquid-liquid microextraction (DLLME), have been developed for the determination of several endocrine-disrupting phenols (EDPs) in seawaters, in combination with high-performance liquid chromatography (HPLC) with UV detection. The EDPs studied were bisphenol-A, 4-cumylphenol, 4-tertbutylphenol, 4-octylphenol and 4-n-nonylphenol. The optimized SDME method used 2.5 microL of decanol suspended at the tip of a micro-syringe immersed in 5 mL of seawater sample, and 60 min for the extraction time. The performance of the SDME is characterized for average relative recoveries of 102+/-11%, precision values (RSD)<9.4% (spiked level of 50 ng mL(-1)), and detection limits between 4 and 9 ng mL(-1). The optimized DLLME method used 150 microL of a mixture acetonitrile:decanol (ratio 15.7, v/v), which is quickly added to 5 mL of seawater sample, then subjected to vortex during 4 min and centrifuged at 2000 rpm for another 5 min. The performance of the DLLME is characterized for average relative recoveries of 98.7+/-3.7%, precision values (RSD)<7.2% (spiked level of 20 ng mL(-1)), and detection limits between 0.2 and 1.6 ng mL(-1). The efficiencies of both methods have also been compared with spiked real seawater samples. The DLLME method has shown to be a more efficient approach for the determination of EDPs in seawater matrices, presenting enrichment factors ranging from 123 to 275, average relative recoveries of 110+/-11%, and precision values (RSD)<14%, when using a real seawaters (spiked level of 3.5 ng mL(-1)).


Journal of Chromatography A | 2010

Utilization of a benzyl functionalized polymeric ionic liquid for the sensitive determination of polycyclic aromatic hydrocarbons; parabens and alkylphenols in waters using solid-phase microextraction coupled to gas chromatography-flame ionization detection.

Jessica López-Darias; Verónica Pino; Yunjing Meng; Jared L. Anderson; Ana M. Afonso

The functionalized polymeric ionic liquid poly(1-(4-vinylbenzyl)-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (poly(VBHDIm(+)NTf(2)(-))) has been used as successful coating in solid-phase microextraction (SPME) to determine a group of fourteen endocrine disrupting chemicals (ECDs), including polycyclic aromatic hydrocarbons (PAHs), alkylphenols, and parabens, in several water samples. The performance of the PIL fiber in direct immersion mode SPME followed by gas chromatography (GC) with flame-ionization detection (FID) is characterized with average relative recoveries higher than 96.1% from deionized waters and higher than 76.7% from drinking bottled waters, with precision values (RSD) lower than 13% for deionized waters and lower than 14% for drinking bottled waters (spiked level of 1 ng mL(-1)), when using an extraction time of 60 min with 20 mL of aqueous sample. Detection limits varied between 9 ng L(-1) and 7 ng mL(-1). A group of real water samples, including drinking waters, well waters, and swimming pool waters, have been analyzed under the optimized conditions. A comparison has also been carried out with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 μm, and polyacrylate (PA) 85 μm. The functionalized PIL fiber (∼12 μm) demonstrated to be superior to both commercial fibers for the overall group of analytes studied, in spite of its lower coating thickness. A normalized sensitivity parameter is proposed as a qualitative tool to compare among fiber materials, being higher for the poly(VBHDIm(+)NTf(2)(-)) coating. Furthermore, the partition coefficients of the studied analytes to the coating materials have been determined. A quantitative comparison among the partition coefficients also demonstrates the superior extraction capability of the functionalized PIL sorbent coating.


Journal of Chromatography A | 2010

Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings

Jessica López-Darias; Verónica Pino; Jared L. Anderson; Christa M. Graham; Ana M. Afonso

The determination of a group of eighteen pollutants in waters, including polycyclic aromatic hydrocarbons and substituted phenols, is conducted in direct-immersion solid-phase microextraction (SPME) using the polymeric ionic liquid (PIL) poly(1-vinyl-3-hexadecylimidazolium) bis[(trifluoromethyl)sulfonyl]imide as a novel coating material. The performance of the PIL fiber coating in the developed IL-SPME-gas chromatography (GC)-mass spectrometry (MS) method is characterized by average relative recoveries of 92.5% for deionized waters and 90.8% for well waters, average precision values (as relative standard deviations, RSD%) of 11% for deionized waters and 12% for well waters, using a spiked level of 5 ng mL(-1). The detection limits oscillate from 0.005 ng mL(-1) for fluoranthene to 4.4 ng mL(-1) for 4-chloro-3-methylphenol, when using an extraction time of 60 min with 20 mL of aqueous sample. The extraction capabilities of the PIL fiber have been compared with the commercial SPME coatings: polydimethylsyloxane (PDMS) 30 microm, PDMS 100 microm and polyacrylate (PA) 85 microm. The PIL fiber is superior to the PDMS 30 microm for all analytes studied. A qualitative study was also carried out to compare among the nature of the coating materials by normalizing the coating thickness. The PIL material was shown to be more efficient than the PDMS material for all analytes studied. The PIL coating was also adequate for nonpolar analytes whereas the PA material was more sensitive for polar compounds.


Journal of Chromatography A | 2000

Determination of polycyclic aromatic hydrocarbons in marine sediments by high-performance liquid chromatography after microwave-assisted extraction with micellar media

Verónica Pino; Juan H. Ayala; Ana M. Afonso; Venerando González

A simple and rapid method is developed for extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in marine sediments. The procedure was based on the microwave-assisted extraction of PAHs in marine sediment samples using a micellar medium of Polyoxyethylene 10 lauryl ether as extractant. Two-level factorial designs have been used to optimize the microwave extraction process. The analysis of extracts has been carried out by HPLC with UV detection. Fortified sediments gave an average recovery between 85.70 and 100.73%, with a relative standard deviation of 1.77-7.0% for PAHs with a ring number higher than three.


Journal of Chromatography A | 2008

The ionic liquid 1-hexadecyl-3-methylimidazolium bromide as novel extracting system for polycyclic aromatic hydrocarbons contained in sediments using focused microwave-assisted extraction.

Verónica Pino; Jared L. Anderson; Juan H. Ayala; Venerando González; Ana M. Afonso

A method to extract PAHs from sediments is carried out using aqueous solutions containing aggregates of the ionic liquid (IL) 1-hexadecyl-3-methylimidazolium bromide (HDMIm-Br) as the extracting medium. Focused microwave-assisted extraction has been used to accelerate the extraction step, followed by HPLC with fluorescence detection without clean-up steps to remove the IL prior to injection. The method has been applied to certified reference sediment BCR-535 and marine sediments from Tenerife (Canary Islands) with successful results. The optimized method gave average absolute recoveries of 91.1% for six of the seven PAHs studied, with relative standard deviations lower than 10.4%. The overall method is characterized for presenting low extraction times (6min), low amounts of the sediment (0.1g), low amounts of IL (45mM), and low volumes of aqueous extractant solution (9mL). The use of small amounts of both IL and aqueous extractant solution allows the method to be considered environmental-friendly.


Analytica Chimica Acta | 2012

Surface-bonded ionic liquid stationary phases in high-performance liquid chromatography--a review.

Verónica Pino; Ana M. Afonso

Ionic liquids (ILs) are a class of ionic, nonmolecular solvents which remain in liquid state at temperatures below 100°C. ILs possess a variety of properties including low to negligible vapor pressure, high thermal stability, miscibility with water or a variety of organic solvents, and variable viscosity. IL-modified silica as novel high-performance liquid chromatography (HPLC) stationary phases have attracted considerable attention for their differential behavior and low free-silanol activity. Indeed, around 21 surface-confined ionic liquids (SCIL) stationary phases have been developed in the last six years. Their chromatographic behavior has been studied, and, despite the presence of a positive charge on the stationary phase, they showed considerable promise for the separation of neutral solutes (not only basic analytes), when operated in reversed phase mode. This aspect points to the potential for truly multimodal stationary phases. This review attempts to summarize the state-of-the-art about SCIL phases including their preparation, chromatographic behavior, and analytical performance.


Journal of Chromatography A | 2002

Determination of polycyclic aromatic hydrocarbons in seawater by high-performance liquid chromatography with fluorescence detection following micelle-mediated preconcentration.

Verónica Pino; Juan H. Ayala; Ana M. Afonso; Venerando González

In this work, the nonionic surfactant polyoxyethylene-10-lauryl ether has been used for the extraction and preconcentration of 14 polycyclic aromatic hydrocarbons, classified as priority pollutants by the US Environmental Protection Agency, from seawater samples. The cloud-point preconcentration previous separation by HPLC and quantification using fluorimetric detection and wavelength programming allow to determine these pollutants with detection limits ranging from 1.0 to 1.5 x 10(2) ng/l with RSDs better than 10.4%. The methodology is evaluated using well-established extraction and preconcentration methods and GC-MS.


Food Additives and Contaminants Part A-chemistry Analysis Control Exposure & Risk Assessment | 2008

Exposure to heterocyclic aromatic amines from the consumption of cooked red meat and its effect on human cancer risk: A review

Mayte Sanz Alaejos; Venerando González; Ana M. Afonso

This review covers the bibliographic data from the last 10 years on the possible carcinogenicity of heterocyclic aromatic amines (HAAs) in humans. Aspects such as red meat intake, cooking methods applied to red meat, and doneness of cooking are discussed from an epidemiological point of view. The role in the carcinogenicity of the HAAs has been assigned to two main factors: first, the very high frequency of consumption of red meat; and, second, very darkly browned meats from cooking. However, there are some uncertainties associated with epidemiological results such as the presence of other carcinogens, co-carcinogens and anti-carcinogens in the diet, analytical results on the content of HAAs in foods, food frequency questionnaires, and mainly genetic susceptibility to HAAs. It is concluded that there is not sufficient scientific evidence to support the hypothesis that human cancer risk is due specifically to the intake of HAAs in the diet.


Talanta | 2015

The metal-organic framework HKUST-1 as efficient sorbent in a vortex-assisted dispersive micro solid-phase extraction of parabens from environmental waters, cosmetic creams, and human urine.

Priscilla Rocío-Bautista; Carla Martínez-Benito; Verónica Pino; Jorge Pasán; Juan H. Ayala; Catalina Ruiz-Pérez; Ana M. Afonso

Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(Al), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-µ-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 μgL(-1) for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R(2)) higher than 0.9966 for a range of 0.5-147 μgL(-1) (depending on the paraben), average relative recoveries (RR, in %) of 80.3% at the low spiked level (7 μgL(-1)), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 ± 0.01 μgg(-1) for EPB in the healing cream analyzed to 1.12 ± 0.07 mgg(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-µ-SPE procedures despite sample complexity.


Talanta | 2009

Ionic liquids as mobile phase additives in high-performance liquid chromatography with electrochemical detection: application to the determination of heterocyclic aromatic amines in meat-based infant foods.

Aurora Martín-Calero; Verónica Pino; Juan H. Ayala; Venerando González; Ana M. Afonso

The beneficial effects of several ionic liquids (ILs) as mobile phase additives in high-performance liquid chromatography with electrochemical detection for the determination of six heterocyclic aromatic amines (HAs) have been evaluated for first-time. The studied ionic liquids were 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF(4)), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF(4)) and 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF(4)). Several chromatographic parameters have been evaluated in the presence or absence of ILs, or using ammonium acetate as the most common mobile phase additive, with three different C18 stationary phases. The effect of the acetonitrile content was also addressed. In general, best resolution, lower peak-widths (up to 72.1% lower) and lower retention factors are obtained when using ILs rather than ammonium acetate as mobile phase additives. The main improvement was obtained in the baseline noise, being 360% less noisy for BMIm-BF(4), 310% for HMIm-BF(4), and 227% for MOIm-BF(4), when compared to ammonium acetate at +1000 mV. Different chromatographic methods using the best conditions for each IL were also evaluated and compared. Finally, the best chromatographic conditions using 1mM of BMIm-BF(4) as mobile phase additive, the Nova-Pak C18 column, 19% (v/v) of acetonitrile content in the mobile phase, and +1000 mV in the ECD, have been applied for the chromatographic analysis of six HAs contained in meat-based infant foods. The whole extraction method of meat-based infant foods using focused microwave-assisted extraction and solid-phase extraction has also been optimized. Extraction efficiencies up to 89% and detection limits ranged between 9.30 and 0.165 ng g(-1) have been obtained under optimized conditions.

Collaboration


Dive into the Ana M. Afonso's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge