Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Anders Snis is active.

Publication


Featured researches published by Anders Snis.


Journal of Biomedical Materials Research Part B | 2008

Electron Beam-Melted, Free-Form-Fabricated Titanium Alloy Implants: Material Surface Characterization and Early Bone Response in Rabbits

Peter Thomsen; Johan Malmström; Lena Emanuelsson; Magnus René; Anders Snis

Titanium-6aluminum-4vanadium implants (Ti6Al4V) were prepared by free-form-fabrication (FFF) and were used either as produced or after machining and compared with wrought machined Ti6Al4V. Auger electron spectroscopy (AES), depth profiles, and interferometry were used to analyze the surface properties. The tissue response after 6-weeks in rabbit femur and tibia was evaluated using light microscopy and histomorphometry. The results revealed that the bulk chemical and mechanical properties of the reference material and the electron beam-melted (EBM) material were within the ASTM F136 specifications. The as-produced EBM Ti6Al4V implants had increased surface roughness, thicker surface oxide and, with the exception of a higher content of Fe, a similar surface chemical composition compared with machined EBM Ti6Al4V and machined, wrought Ti6Al4V implants. The two latter implants did not differ with respect to surface properties. The general tissue response was similar for all three implant types. Histomorphometry revealed a high degree of bone-to-implant contact (no statistically significant differences) for all the three implant types. The present results show that the surface properties of EBM Ti6Al4V display biological short-term behavior in bone equal to that of conventional wrought titanium alloy. The opportunity to engineer geometric properties provides new and additional benefits which justify further studies.


Journal of Biomaterials Applications | 2013

Long-term biocompatibility and osseointegration of electron beam melted, free-form–fabricated solid and porous titanium alloy: Experimental studies in sheep

Anders Palmquist; Anders Snis; Lena Emanuelsson; M Browne; Peter Thomsen

The purpose of the present study was to evaluate the long-term osseointegration and biocompatibility of electron beam melted (EBM) free-form–fabricated (FFF titanium grade 5 (Ti6Al4V) implants. Porous and solid machined cylindrical and disk-shaped implants were prepared by EBM and implanted bilaterally in the femur and subcutaneously in the dorsum of the sheep. After 26 weeks, the implants and surrounding tissue were retrieved. The tissue response was examined qualitatively and quantitatively using histology and light microscopic (LM) morphometry. Selected bone implants specimens were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and micro-computed tomography (mCT). The results showed that both porous and solid implants were osseointegrated and high bone–implant contact was observed throughout the porous implant. In the soft tissue, the porous implants showed thinner fibrous encapsulation while no signs of intolerance were observed for either implant type. Taken together, the present experimental results show that FFF Ti6Al4V with and without porous structures demonstrate excellent long-term soft tissue biocompatibility and a high degree of osseointegration. The present findings extend earlier, short-term experimental observations in bone and suggest that EBM, FFF Ti6Al4V implants possess valuable properties in bone and soft tissue applications.


Rapid Prototyping Journal | 2012

Effect of process parameters settings and thickness on surface roughness of EBM produced Ti-6Al-4V

Adnan Safdar; H.Z. He; Liu-Ying Wei; Anders Snis; Luis Eduardo Chávez de Paz

Purpose – Ti‐6Al‐4V is one of the most attractive materials being used in aerospace, automotive and medical implant industries. Electron beam melting (EBM) is one of the direct digital manufacturing methods to produce complex geometries of fully dense and near net shape parts. The EBM system provides an opportunity to built metallic objects with different processing parameter settings like beam current, scan speed, probe size on powder, etc. The purpose of this paper is to determine and understand the effect of parts thickness and variation in process parameter settings of the EBM system on surface roughness/topography of EBM fabricated Ti‐6Al‐4V metallic parts.Design/methodology/approach – A mathematical model based upon response surface methodology (RSM) is developed to study the variation of surface roughness with changing process parameter settings. Surface roughness of the test slabs produced with different parameter settings and thickness has been studied under confocal microscope. Response surface...


Acta Biomaterialia | 2016

Long-term osseointegration of 3D printed CoCr constructs with an interconnected open-pore architecture prepared by electron beam melting

Furqan A. Shah; Omar Omar; Felicia Suska; Anders Snis; Aleksandar Matic; Lena Emanuelsson; Birgitta Norlindh; Jukka Lausmaa; Peter Thomsen; Anders Palmquist

UNLABELLED In orthopaedic surgery, cobalt chromium (CoCr) based alloys are used extensively for their high strength and wear properties, but with concerns over stress shielding and bone resorption due to the high stiffness of CoCr. The structural stiffness, principally related to the bulk and the elastic modulus of the material, may be lowered by appropriate design modifications, to reduce the stiffness mismatch between metal/alloy implants and the adjacent bone. Here, 3D printed CoCr and Ti6Al4V implants of similar macro-geometry and interconnected open-pore architecture prepared by electron beam melting (EBM) were evaluated following 26week implantation in adult sheep femora. Despite higher total bone-implant contact for Ti6Al4V (39±4%) than CoCr (27±4%), bone formation patterns were similar, e.g., densification around the implant, and gradual ingrowth into the porous network, with more bone in the outer half (periphery) than the inner half (centre). Raman spectroscopy revealed no major differences in mineral crystallinity, the apatite-to-collagen ratio, or the carbonate-to-phosphate ratio. Energy dispersive X-ray spectroscopy showed similar Ca/P ratio of the interfacial tissue adjacent to both materials. Osteocytes made direct contact with CoCr and Ti6Al4V. While osteocyte density and distribution in the new-formed bone were largely similar for the two alloys, higher osteocyte density was observed at the periphery of the porous network for CoCr, attributable to slower remodelling and a different biomechanical environment. The results demonstrate the possibility to achieve bone ingrowth into open-pore CoCr constructs, and attest to the potential for fabricating customised osseointegrated CoCr implants for load-bearing applications. STATEMENT OF SIGNIFICANCE Although cobalt chromium (CoCr) based alloys are used extensively in orthopaedic surgery, stress shielding due to the high stiffness of CoCr is of concern. To reduce the stiffness mismatch between CoCr and bone, CoCr and Ti6Al4V implants having an interconnected open-pore architecture were prepared by electron beam melting (EBM). After six months of submerged healing in sheep, both alloys showed similar patterns of bone formation, with densification around the implant and gradual ingrowth into the porous network. The molecular and elemental composition of the interfacial tissue was similar for both alloys. Osteocytes made direct contact with both alloys, with similar overall osteocyte density and distribution. The work attests to the potential for achieving osseointegration of EBM manufactured porous CoCr implants.


Journal of Oral and Maxillofacial Surgery | 2016

Electron Beam Melting Manufacturing Technology for Individually Manufactured Jaw Prosthesis: A Case Report

Felicia Suska; Göran Kjeller; P. Tarnow; Eduard Hryha; Lars Nyborg; Anders Snis; Anders Palmquist

In the field of maxillofacial reconstruction, additive manufacturing technologies, specifically electron beam melting (EBM), offer clinicians the potential for patient-customized design of jaw prostheses, which match both load-bearing and esthetic demands. The technique allows an innovative, functional design, combining integrated porous regions for bone ingrowth and secondary biological fixation with solid load-bearing regions ensuring the biomechanical performance. A patient-specific mandibular prosthesis manufactured using EBM was successfully used to reconstruct a patients mandibular defect after en bloc resection. Over a 9-month follow-up period, the patient had no complications. A short operating time, good esthetic outcome, and high level of patient satisfaction as measured by quality-of-life questionnaires-the European Organisation for Research and Treatment of Cancer QLQ-C30 (30-item quality-of-life core questionnaire) and H&N35 (head and neck cancer module)-were reported for this case. Individually planned and designed EBM-produced prostheses may be suggested as a possible future alternative to fibular grafts or other reconstructive methods. However, the role of porosity, the role of geometry, and the optimal combination of solid and porous parts, as well as surface properties in relation to soft tissues, should be carefully evaluated in long-term clinical trials.


Journal of Materials Processing Technology | 2013

Characterization and comparison of materials produced by Electron Beam Melting (EBM) of two different Ti-6Al-4V powder fractions

Joakim Karlsson; Anders Snis; Håkan Engqvist; Jukka Lausmaa


Materials Characterization | 2012

Evaluation of microstructural development in electron beam melted Ti-6Al-4V

Adnan Safdar; Liu-Ying Wei; Anders Snis; Zhonge Lai


Archive | 2006

Method and device for producing three-dimensional objects

Morgan Larsson; Anders Snis


Archive | 2011

METHOD FOR PRODUCTION OF A THREE-DIMENSIONAL BODY

Anders Snis


Acta Biomaterialia | 2016

3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface

Furqan A. Shah; Anders Snis; Aleksandar Matic; Peter Thomsen; Anders Palmquist

Collaboration


Dive into the Anders Snis's collaboration.

Top Co-Authors

Avatar

Jukka Lausmaa

SP Technical Research Institute of Sweden

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Thomsen

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Aleksandar Matic

Chalmers University of Technology

View shared research outputs
Top Co-Authors

Avatar

Felicia Suska

University of Gothenburg

View shared research outputs
Researchain Logo
Decentralizing Knowledge