Andrea Protti
King's College London
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Andrea Protti.
Bioconjugate Chemistry | 2011
Rafael T. M. de Rosales; Richard Tavaré; Arnaud Pierre Alain Glaria; Gopal Varma; Andrea Protti; Philip J. Blower
The combination of radionuclide-based imaging modalities such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) with magnetic resonance imaging (MRI) is likely to become the next generation of clinical scanners. Hence, there is a growing interest in the development of SPECT- and PET-MRI agents. To this end, we report a new class of dual-modality imaging agents based on the conjugation of radiolabeled bisphosphonates (BP) directly to the surface of superparamagnetic iron oxide (SPIO) nanoparticles. We demonstrate the high potential of BP-iron oxide conjugation using (⁹⁹m)Tc-dipicolylamine(DPA)-alendronate, a BP-SPECT agent, and Endorem/Feridex, a liver MRI contrast agent based on SPIO. The labeling of SPIOs with (⁹⁹m)Tc-DPA-alendronate can be performed in one step at room temperature if the SPIO is not coated with an organic polymer. Heating is needed if the nanoparticles are coated, as long as the coating is weakly bound as in the case of dextran in Endorem. The size of the radiolabeled Endorem (⁹⁹m)Tc-DPA-ale-Endorem) was characterized by TEM (5 nm, Fe₃O₄ core) and DLS (106 ± 60 nm, Fe₃O₄ core + dextran). EDX, Dittmer-Lester, and radiolabeling studies demonstrate that the BP is bound to the nanoparticles and that it binds to the Fe₃O₄ cores of Endorem, and not its dextran coating. The bimodal imaging capabilities and excellent stability of these nanoparticles were confirmed using MRI and nanoSPECT-CT imaging, showing that (⁹⁹m)Tc and Endorem co-localize in the liver and spleen In Vivo, as expected for particles of the composition and size of (⁹⁹m)Tc-DPA-ale-Endorem. To the best of our knowledge, this is the first example of radiolabeling SPIOs with BP conjugates and the first example of radiolabeling SPIO nanoparticles directly onto the surface of the iron oxide core, and not its coating. This work lays down the basis for a new generation of SPECT/PET-MR imaging agents in which the BP group could be used to attach functionality to provide targeting, stealth/stability, and radionuclides to Fe₃O₄ nanoparticles using very simple methodology readily amenable to GMP.
ACS Nano | 2013
Lydia Sandiford; Alkystis Phinikaridou; Andrea Protti; Levente K. Meszaros; Xianjin Cui; Yong Yan; George Frodsham; Peter Williamson; Nicholas Gaddum; René M. Botnar; Philip J. Blower; Mark Green; Rafael T. M. de Rosales
The efficient delivery of nanomaterials to specific targets for in vivo biomedical imaging is hindered by rapid sequestration by the reticuloendothelial system (RES) and consequent short circulation times. To overcome these two problems, we have prepared a new stealth PEG polymer conjugate containing a terminal 1,1-bisphosphonate (BP) group for strong and stable binding to the surface of ultrasmall-superparamagnetic oxide nanomaterials (USPIOs). This polymer, PEG(5)-BP, can be used to exchange the hydrophobic surfactants commonly used in the synthesis of USPIOs very efficiently and at room temperature using a simple method in 1 h. The resulting nanoparticles, PEG(5)-BP-USPIOs are stable in water or saline for at least 7 months and display a near-zero ζ-potential at neutral pH. The longitudinal (r1) and transverse (r2) relaxivities were measured at a clinically relevant magnetic field (3 T), revealing a high r1 of 9.5 mM–1 s–1 and low r2/r1 ratio of 2.97, making these USPIOs attractive as T1-weighted MRI contrast agents at high magnetic fields. The strong T1-effect was demonstrated in vivo, revealing that PEG(5)-BP-USPIOs remain in the bloodstream and enhance its signal 6-fold, allowing the visualization of blood vessels and vascular organs with high spatial definition. Furthermore, the optimal relaxivity properties allow us to inject a dose 4 times lower than with other USPIOs. PEG(5)-BP-USPIOs can also be labeled using a radiolabeled-BP for visualization with single photon emission computed tomography (SPECT), and thus affording dual-modality contrast. The SPECT studies confirmed low RES uptake and long blood circulation times (t1/2 = 2.97 h). These results demonstrate the potential of PEG(5)-BP-USPIOs for the development of targeted multimodal imaging agents for molecular imaging.
Angewandte Chemie | 2011
Rafael T. M. de Rosales; Richard Tavaré; Rowena L. Paul; Maite Jauregui-Osoro; Andrea Protti; Arnaud Pierre Alain Glaria; Gopal Varma; Istvan Szanda; Philip J. Blower
The synergistic combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) is likely to become the next generation of dual-modality scanners in medical imaging. These instruments will provide us with accurate diagnoses thanks to the sensitive and quantifiable signal of PET and the high soft-tissue resolution of MRI. Furthermore, patients will receive less radiation dose and spend less time in the procedure relative to current dual-modality scanners (e.g. PET–computed tomography (CT)). As a consequence, there has been increasing interest recently in the development of dual-modality PET–MRI agents.[1]
Circulation | 2012
Alkystis Phinikaridou; Marcelo E. Andia; Andrea Protti; Andreas Indermuehle; Ajay M. Shah; Alberto Smith; Alice Warley; René M. Botnar
Background— Endothelial dysfunction promotes atherosclerosis and precedes acute cardiovascular events. We investigated whether in vivo magnetic resonance imaging with the use of an albumin-binding contrast agent, gadofosveset, could detect endothelial damage associated with atherosclerosis in apolipoprotein E–deficient (ApoE−/−) mice. Furthermore, we tested whether magnetic resonance imaging could noninvasively assess endothelial function by measuring the endothelial-dependent vasodilation in response to acetylcholine. Methods and Results— ApoE−/− mice were imaged at 4, 8, and 12 weeks after commencement of a high-fat diet. Statin-treated ApoE−/− mice were scanned after 12 weeks of a high-fat diet. Wild-type mice were imaged before and 48 hours after injection of Russells viper venom, an endothelial toxin. Delayed enhancement magnetic resonance imaging and T1 mapping of the brachiocephalic artery, 30 minutes after injection of gadofosveset, showed increased vessel wall enhancement and relaxation rate (R1) with progression of atherosclerosis in ApoE−/−(R1 [s−1]: R4 weeks 2.42±0.35, R8 weeks 3.45±0.54, R12 weeks 3.83±0.52) and Russells viper venom–injected wild-type mice (R1=4.57±0.86). Conversely, wild-type (R1=2.15±0.34) and statin-treated ApoE−/− (R1=3.0±0.65) mice showed less enhancement. Uptake of gadofosveset correlated with Evans blue staining, morphological changes of endothelial cells, and widening of the cell-cell junctions, suggesting that uptake occurs in regions of increased vascular permeability. Endothelial-dependent vasomotor responses showed vasoconstriction of the arteries of the ApoE−/− (−22.22±7.95%) and Russells viper venom–injected (−10.37±17.60%) mice compared with wild-type mice (32.45±12.35%). Statin treatment improved endothelium morphology and function (−8.12±8.22%). Conclusions— We demonstrate the noninvasive assessment of endothelial permeability and function with the use of an albumin-binding magnetic resonance contrast agent. Blood albumin leakage could be a surrogate marker for the in vivo evaluation of interventions that aim to restore the endothelium.
Circulation | 2012
Alkystis Phinikaridou; Marcelo E. Andia; Andrea Protti; Andreas Indermuehle; Ajay M. Shah; Alberto Smith; Alice Warley; René M. Botnar
Background— Endothelial dysfunction promotes atherosclerosis and precedes acute cardiovascular events. We investigated whether in vivo magnetic resonance imaging with the use of an albumin-binding contrast agent, gadofosveset, could detect endothelial damage associated with atherosclerosis in apolipoprotein E–deficient (ApoE−/−) mice. Furthermore, we tested whether magnetic resonance imaging could noninvasively assess endothelial function by measuring the endothelial-dependent vasodilation in response to acetylcholine. Methods and Results— ApoE−/− mice were imaged at 4, 8, and 12 weeks after commencement of a high-fat diet. Statin-treated ApoE−/− mice were scanned after 12 weeks of a high-fat diet. Wild-type mice were imaged before and 48 hours after injection of Russells viper venom, an endothelial toxin. Delayed enhancement magnetic resonance imaging and T1 mapping of the brachiocephalic artery, 30 minutes after injection of gadofosveset, showed increased vessel wall enhancement and relaxation rate (R1) with progression of atherosclerosis in ApoE−/−(R1 [s−1]: R4 weeks 2.42±0.35, R8 weeks 3.45±0.54, R12 weeks 3.83±0.52) and Russells viper venom–injected wild-type mice (R1=4.57±0.86). Conversely, wild-type (R1=2.15±0.34) and statin-treated ApoE−/− (R1=3.0±0.65) mice showed less enhancement. Uptake of gadofosveset correlated with Evans blue staining, morphological changes of endothelial cells, and widening of the cell-cell junctions, suggesting that uptake occurs in regions of increased vascular permeability. Endothelial-dependent vasomotor responses showed vasoconstriction of the arteries of the ApoE−/− (−22.22±7.95%) and Russells viper venom–injected (−10.37±17.60%) mice compared with wild-type mice (32.45±12.35%). Statin treatment improved endothelium morphology and function (−8.12±8.22%). Conclusions— We demonstrate the noninvasive assessment of endothelial permeability and function with the use of an albumin-binding magnetic resonance contrast agent. Blood albumin leakage could be a surrogate marker for the in vivo evaluation of interventions that aim to restore the endothelium.
PLOS Genetics | 2014
Michal Mielcarek; Linda Inuabasi; Marie K. Bondulich; Thomas Muller; Georgina F. Osborne; Sophie A. Franklin; Donna L. Smith; Andreas Neueder; Jim Rosinski; Ivan Rattray; Andrea Protti; Gillian P. Bates
Cardiac remodelling and contractile dysfunction occur during both acute and chronic disease processes including the accumulation of insoluble aggregates of misfolded amyloid proteins that are typical features of Alzheimers, Parkinsons and Huntingtons disease (HD). While HD has been described mainly as a neurological disease, multiple epidemiological studies have shown that HD patients exhibit a high incidence of cardiovascular events leading to heart failure, and that this is the second highest cause of death. Given that huntingtin is ubiquitously expressed, cardiomyocytes may be at risk of an HD-related dysfunction. In mice, the forced expression of an expanded polyQ repeat under the control of a cardiac specific promoter led to severe heart failure followed by reduced lifespan. However the mechanism leading to cardiac dysfunction in the clinical and pre-clinical HD settings remains unknown. To unravel this mechanism, we employed the R6/2 transgenic and HdhQ150 knock-in mouse models of HD. We found that pre-symptomatic animals developed connexin-43 relocation and a significant deregulation of hypertrophic markers and Bdnf transcripts. In the symptomatic animals, pronounced functional changes were visualised by cardiac MRI revealing a contractile dysfunction, which might be a part of dilatated cardiomyopathy (DCM). This was accompanied by the re-expression of foetal genes, apoptotic cardiomyocyte loss and a moderate degree of interstitial fibrosis. To our surprise, we could identify neither mutant HTT aggregates in cardiac tissue nor a HD-specific transcriptional dysregulation, even at the end stage of disease. We postulate that the HD-related cardiomyopathy is caused by altered central autonomic pathways although the pathogenic effects of mutant HTT acting intrinsically in the heart may also be a contributing factor.
Advanced Functional Materials | 2014
Julie Tzu-Wen Wang; Laura Cabana; Maxime Bourgognon; Houmam Kafa; Andrea Protti; Kerrie Venner; Ajay M. Shah; Jane K. Sosabowski; Stephen J. Mather; Anna Roig; Xiaoxing Ke; Gustaaf Van Tendeloo; Rafael T. M. de Rosales; Gerard Tobias; Khuloud T. Al-Jamal
Carbon nanotubes (CNTs) have been proposed as one of the most promising nanomaterials to be used in biomedicine for their applications in drug/gene delivery as well as biomedical imaging. The present study developed radio-labeled iron oxide decorated multi-walled CNTs (MWNT) as dual magnetic resonance (MR) and single photon emission computed tomography (SPECT) imaging agents. Hybrids containing different amounts of iron oxide were synthesized by in situ generation. Physicochemical characterisations revealed the presence of superparamagnetic iron oxide nanoparticles (SPION) granted the magnetic properties of the hybrids. Further comprehensive examinations including high resolution transmission electron microscopy (HRTEM), fast Fourier transform simulations (FFT), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) assured the conformation of prepared SPION as γ-Fe2O3. High r2 relaxivities were obtained in both phantom and in vivo MRI compared to the clinically approved SPION Endorem®. The hybrids were successfully radio-labeled with technetium-99m through a functionalized bisphosphonate and enabled SPECT/CT imaging and γ-scintigraphy to quantitatively analyze the biodistribution in mice. No abnormality was found by histological examination and the presence of SPION and MWNT were identified by Perls stain and Neutral Red stain, respectively. TEM images of liver and spleen tissues showed the co-localization of SPION and MWNT within the same intracellular vesicles, indicating the in vivo stability of the hybrids after intravenous injection. The results demonstrated the capability of the present SPION-MWNT hybrids as dual MRI and SPECT contrast agents for in vivo use.
Journal of Magnetic Resonance Imaging | 2010
Andrea Protti; Alexander Sirker; Ajay M. Shah; René M. Botnar
To investigate myocardial infarction (MI), late gadolinium (Gd) enhancement (LGE), cardiovascular magnetic resonance imaging (CMRI) is used as the current gold standard for the in vivo diagnosis in patients and preclinical studies. While inversion recovery (IR) fast gradient echo LGE imaging is the preferred technique at clinical field strengths it remains to be investigated which is the best sequence at higher field strength. We therefore compared the IR technique against cine fast low shot angle (cine‐FLASH) for the quantification of MI size in mice at 7T in vivo.
American Journal of Physiology-heart and Circulatory Physiology | 2014
Amit Bhan; Alexander Sirker; Juqian Zhang; Andrea Protti; Norman Catibog; William Driver; René M. Botnar; Mark Monaghan; Ajay M. Shah
The objectives of this study were to assess the feasibility and accuracy of high-frequency speckle tracking echocardiography (STE) in a murine model of myocardial infarction (MI). STE is used clinically to quantify global and regional cardiac function, but its application in mice is challenging because of the small cardiac size and rapid heart rates. A high-frequency micro-ultrasound system with STE (Visualsonics Vevo 2100) was compared against magnetic resonance imaging (MRI) for the assessment of global left ventricular (LV) size and function after murine MI. Animals subjected to coronary ligation (n = 46) or sham ligation (n = 27) were studied 4 wk postoperatively. Regional and global deformation were also assessed. STE-derived LV ejection fraction (EF) and mass correlated well with MRI indexes (r = 0.93, 0.77, respectively; P < 0.001), as did STE-derived mass with postmortem values (r = 0.80, P < 0.001). Higher STE-derived volumes correlated positively with MRI-derived infarct size (P < 0.01). Global strain parameters were significantly reduced after MI (all P < 0.001) and strongly correlated with LV mass and MRI-derived infarct size as promising surrogates for the extent of remodeling and infarction, respectively (both P < 0.05). Regional strain analyses showed that radial strain and strain rate were relatively preserved in anterior basal segments after MI compared with more apical segments (P < 0.001); however, longitudinal strain and strain rate were significantly impaired both basally and distally (P < 0.001). Strain-derived parameters of dyssynchrony were significantly increased in the MI group (P < 0.01). Analysis time for STE was 210 ± 45 s with acceptable inter- and intraobserver variability. In conclusion, high-frequency STE enables quantitative assessment of regional and global function in the remodeling murine LV after MI.
Bioconjugate Chemistry | 2016
Xianjin Cui; Domokos Máthé; Noémi Kovács; Ildiko Horvath; Maite Jauregui-Osoro; Rafael T. M. de Rosales; Gregory Mullen; Wilson Wong; Yong Yan; Dirk Krüger; Andrei N. Khlobystov; Maria del Carmen Gimenez-Lopez; Mariann Semjeni; Krisztián Szigeti; Dániel S. Veres; Haizhou Lu; Ignacio Hernández; W. P. Gillin; Andrea Protti; Katalin Kis Petik; Mark Green; Philip J. Blower
Multimodal nanoparticulate materials are described, offering magnetic, radionuclide, and fluorescent imaging capabilities to exploit the complementary advantages of magnetic resonance imaging (MRI), positron emission tomography/single-photon emission commuted tomography (PET/SPECT), and optical imaging. They comprise Fe3O4@NaYF4 core/shell nanoparticles (NPs) with different cation dopants in the shell or core, including Co0.16Fe2.84O4@NaYF4(Yb, Er) and Fe3O4@NaYF4(Yb, Tm). These NPs are stabilized by bisphosphonate polyethylene glycol conjugates (BP-PEG), and then show a high transverse relaxivity (r2) up to 326 mM(-1) s(-1) at 3T, a high affinity to [(18)F]-fluoride or radiometal-bisphosphonate conjugates (e.g., (64)Cu and (99m)Tc), and fluorescent emissions from 500 to 800 nm under excitation at 980 nm. The biodistribution of intravenously administered particles determined by PET/MR imaging suggests that negatively charged Co0.16Fe2.84O4@NaYF4(Yb, Er)-BP-PEG (10K) NPs cleared from the blood pool more slowly than positively charged NPs Fe3O4@NaYF4(Yb, Tm)-BP-PEG (2K). Preliminary results in sentinel lymph node imaging in mice indicate the advantages of multimodal imaging.